5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 5 Years Limited" in the power module table.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Anker SOLIX E10 power module (A17E1): the image Anker SOLIX's own US store ties to SKU A17E1141, the power module sold on its own. The module alone, no battery, no overlay.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Grounding | Ground Terminal | Printed as "Ground Terminal" in Anker SOLIX's 1. About This Guide 1.1 Purpose and Scope 1.2 Related Guide 1.3 Model Reference 2. Unboxing 2.1 Check Before Installatio (PDF page 7). The manual applies to this model: E10 User Guide (US) 1.3 Model Reference: A17E1 = Anker SOLIX E10 Power Module; A17E1141-85 = Anker SOLIX B6000 Battery Module. Where: PDF page 7 | [2] |
| Weight | 27.5 kg / 60.6 lb converted | Printed as "Weight 60.6 lbs (27.5 kg)". Where: 9.1 (PDF page 40), Others, Weight | [3] |
| MPPT count | 2 | Printed as "MPPTs 2". Where: 9.1 (PDF page 40), DC Solar Input | [3] |
| Peak output | 41.6A / 10kW (90 minutes, ambient temperature < 86°F / 30°C), with two battery modules or more | Printed as "Peak Backup Output Current / Power (With Two Battery Modules or More) 41.6A / 10kW (90 minutes, ambient temperature < 86°F / 30°C)". Where: 9.1 (PDF page 39), Peak Backup Output Current / Power | [3] |
| Clearances | at least 11.8 in (30 cm) clearance from the ceiling | Printed as "Keep at least 11.8 in (30 cm) clearance from the ceiling for heat dissipation." in Anker SOLIX's 1. About This Guide 1.1 Purpose and Scope 1.2 Related Guide 1.3 Model Reference 2. Unboxing 2.1 Check Before Installatio (PDF page 14). The manual applies to this model: E10 User Guide (US) 1.3 Model Reference: A17E1 = Anker SOLIX E10 Power Module; A17E1141-85 = Anker SOLIX B6000 Battery Module. Where: PDF page 14 | [2] |
| Dimensions | W 670 × H 300 × D 260 mm / W 26.4 × H 11.8 × D 10.2 in converted | Printed as "Dimensions (W × H × D) 26.4 × 11.8 × 10.2 in (670 × 300 × 260 mm)". Where: 9.1 (PDF page 40), Others, Dimensions (W × H × D) | [3] |
| PV disconnect | PV switch on the power module | Printed as "Ensure the PV switch on the power module is turned off." in Anker SOLIX's 1. About This Guide 1.1 Purpose and Scope 1.2 Related Guide 1.3 Model Reference 2. Unboxing 2.1 Check Before Installatio (PDF page 33). The manual applies to this model: E10 User Guide (US) 1.3 Model Reference: A17E1 = Anker SOLIX E10 Power Module; A17E1141-85 = Anker SOLIX B6000 Battery Module. Where: PDF page 33 | [2] |
| Communications | Wi-Fi, Bluetooth | Printed as "Connectivity Wi‑Fi, Bluetooth". Where: 9.1 (PDF page 40), Others, Connectivity | [3] |
| AC configuration | 120/240 VAC split phase, 60 Hz | Printed as "Rated Voltage 120 / 240 VAC (Split Phase) Rated Frequency 60Hz". Where: 9.1 (PDF page 39), Backup AC Port | [3] |
| Enclosure rating | NEMA 4 | Printed as "Enclosure Type NEMA 4". Where: 9.1 (PDF page 40), Others, Enclosure Type | [3] |
| Max PV current | 15 A | Printed as "Maximum Current per MPPT (Imp) 15 ADC"; the PV DC input voltage range is printed as "30 to 450 VDC" and each MPPT's maximum input power as "4.5kW". Where: 9.1 (PDF page 40), DC Solar Input | [3] |
| Continuous output | 7.68 kW | Printed as "Maximum Continuous Output Power (With Battery Module) 7.68kW" for the backup AC port; the on-grid AC port prints the same 7.68kW for continuous input and output. Where: 9.1 Anker SOLIX E10 Power Module (PDF page 39), Backup AC Port | [3] |
| Mounting orientation | Floor Mount / Wall Mount | Printed as "Mounting Option Floor Mount / Wall Mount" in Anker SOLIX's 1. About This Guide 1.1 Purpose and Scope 1.2 Related Guide 1.3 Model Reference 2. Unboxing 2.1 Check Before Installatio (PDF page 40). The manual applies to this model: E10 User Guide (US) 1.3 Model Reference: A17E1 = Anker SOLIX E10 Power Module; A17E1141-85 = Anker SOLIX B6000 Battery Module. Where: PDF page 40 | [2] |
| Max PV short circuit | 20 A | Printed as "Maximum Short Circuit Current per MPPT (Isc) 20 ADC". Where: 9.1 (PDF page 40), DC Solar Input | [3] |
| Battery voltage range | 380 to 450 V | Printed as "Charge / Discharge Voltage Range 380 to 450 VDC". Where: 9.1 (PDF page 40), Battery Input / Output | [3] |
| Operating temperature | -20 to 55 °C / -4 to 131 °F converted | Printed as "‑4 to 131 °F (‑20 to 55°C)". Where: 9.1 (PDF page 40), Others, Operating Temperature | [3] |
No listed sellers in this data.
No seller price history.
Each price below is for the whole bundle, not for this product on its own.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 5 Years Limited" in the power module table.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 5 years | Printed as "Warranty 5 Years Limited" in the power module table. Where: 9.1 (PDF page 40), Others, Warranty | [3] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-16.
Location: Installation instructions
Retrieved Oct 16, 2026
Anker SOLIX's own manual, captured October 16, 2026 with the paced research fetcher (robots.txt read first). Manufacturer instructions, not independent tests.
Archived copy of a document published by Anker SOLIX. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Anker SOLIX published. Original address: https://cdn.shopify.com/s/files/1/0854/3820/2186/files/Anker_SOLIX_E10_A17E1_User_Guide.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 36c8b81dab9d7463ef4e395102061d695d8365b4b4080c23a5226c234d2f34f2
Archived copy captured on 2026-10-01.
Location: Page heading; structured product data in the markup
Retrieved Oct 1, 2026
Anker SOLIX's US store page for the E10 Power Module sold on its own (prices in US dollars). Its structured product data names SKU A17E1141. Cited for the listing name and SKU. Captured October 1, 2026. Manufacturer claims, not independently verified.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Anker SOLIX. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Anker SOLIX published. Original address: https://cdn.shopify.com/s/files/1/0854/3820/2186/files/Anker_SOLIX_E10_A17E1_User_Guide.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 36c8b81dab9d7463ef4e395102061d695d8365b4b4080c23a5226c234d2f34f2
No sourced accessories or replacement parts listed yet.
Manufacturer SKU A17E1141 · US market
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 30 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 5 unit: Unknown shown: 5 years shown detail: Unknown state: documented points: 6 ceiling: 30 weight: 30 share: 20 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [3] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details