About brandNingbo Deye Technology Co., Ltd. of Beilun, Ningbo, China makes hybrid inverters and lithium iron phosphate energy storage, from wall-mounted residential packs to rack and cabinet systems for small commercial sites.
SKU detail
locator: Brochure page 2, Rack-Mounted Battery table, Model row
conditions: Printed as "BOS-GH40" in the Model row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0). Deye publishes no separate stock keeping number; the model designation is recorded, as on the catalog's other Deye records.
Printed as "LiFePO4" in the Cell Chemistry row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns.
Printed as "53+45 × 8+20=433kg" in the Weight Approximate ( kg ) row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), read from the BOS-GH40 column of the rendered page 2 table; an approximate figure, the brochure's own sum of cabinet, eight modules and control box.
Printed as "25±2°C, 0.5C / 0.5C, EOL70%≥6000" in the Cycle Life row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns: at least 6,000 cycles at 25±2°C, 0.5C charge and discharge, to 70% end-of-life capacity.
Where: Brochure page 2, Rack-Mounted Battery table, Cycle Life row
Printed as "Module Capacity ( Ah ) 100" in Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), read from the rendered page 2 table, in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns; this is the capacity of one 5.12 kWh module.
W 530 × H 1,629 × D 667 mm / W 20.9 × H 64.13 × D 26.3 in converted
Printed as "530 × 667 × 1629" in the Dimension ( W × D × H, mm ) row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), read from the BOS-GH40 column of the rendered page 2 table; width 530 mm, depth 667 mm, height 1629 mm, as the row heading orders them.
Where: Brochure page 2, Rack-Mounted Battery table, Dimension ( W × D × H, mm ) row
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "Rack-Mounted Battery" and "Standard 19inch rack can install 12 / 8 pcs batteries". Classified as Server rack from the maker's own words for this model.
Location: Deye BOS-GL60 & BOS-GH60 series brochure, North America, 2026-07-07 v1.0
Communications
CAN2.0; RS485
Printed as "CAN2.0 / RS485" in the Communication Port row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns.
Where: Brochure page 2, Rack-Mounted Battery table, Communication Port row
Printed as "IP20" in the IP Rating of Enclosure row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns.
Where: Brochure page 2, Rack-Mounted Battery table, IP Rating of Enclosure row
Printed as "125" in the "Peak Discharge ( 5S, 25℃ )" row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns: a five-second peak at 25°C.
Printed as "409.6" in the System Nominal Voltage ( V ) row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), read from the BOS-GH40 column of the rendered page 2 table.
Where: Brochure page 2, Rack-Mounted Battery table, System Nominal Voltage ( V ) row
Printed as "Module Energy ( kWh ) 5.12" in Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), read from the rendered page 2 table, in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns.
Printed as "409.6" in the System Nominal Voltage ( V ) row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), read from the BOS-GH40 column of the rendered page 2 table. This is the cabinet/rack system rating used for the headline. The former 51.2 V headline was the module row and is retained separately.
Where: Brochure page 2, Rack-Mounted Battery table, System Nominal Voltage ( V ) row
Printed as "40.96" in the System Energy ( kWh ) row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), read from the BOS-GH40 column of the rendered page 2 table.
Where: Brochure page 2, Rack-Mounted Battery table, System Energy ( kWh ) row
Printed as "36.86" in the System Usable Energy ( kWh ) row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), read from the BOS-GH40 column of the rendered page 2 table; footnote 1 reads "DC Usable Energy, test conditions : 90% DOD, 0.3C charge & discharge at 25°C. System usable energy may vary due to system configuration parameters.".
Where: Brochure page 2, Rack-Mounted Battery table, System Usable Energy ( kWh ) row
Printed as "25±2°C, 0.5C / 0.5C, EOL70%≥6000" in the same maker document as the recorded cycle life; the cycle life ends at 70% of capacity as printed.
Where: Brochure page 2, Rack-Mounted Battery table, Cycle Life row
Printed as "40.96" in the System Energy ( kWh ) row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), read from the BOS-GH40 column of the rendered page 2 table.
Where: Brochure page 2, Rack-Mounted Battery table, System Energy ( kWh ) row
Printed as "320 ~ 467.2" in the System Operating Voltage ( V ) row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), read from the BOS-GH40 column of the rendered page 2 table.
Where: Brochure page 2, Rack-Mounted Battery table, System Operating Voltage ( V ) row
Printed as "UL1973 / UL9540A / UN38.3 / UL9540" in the Certification row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns. Manufacturer claims; no issuer record was checked.
Printed as "Charge : 0 ~ 55 / Discharge : -20 ~ 55" in the Working Temperature ( °C ) row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns.
Where: Brochure page 2, Rack-Mounted Battery table, Working Temperature ( °C ) row
Printed as "50" in the Recommend row of the Charge / Discharge Current ( A ) block of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell the table shares across the BOS-GH40 and BOS-GH60 columns (the BOS-GL60 column prints 100); the row covers both charge and discharge. Footnote 2 reads "The current is affected by temperature and SOC."
Where: Brochure page 2, Rack-Mounted Battery table, Charge / Discharge Current ( A ), Recommend row
Printed as "0 ~ 35" in the Storage Temperature ( °C ) row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns.
Where: Brochure page 2, Rack-Mounted Battery table, Storage Temperature ( °C ) row
Printed as "Charge : 0 ~ 55 / Discharge : -20 ~ 55" in the Working Temperature ( °C ) row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns.
Where: Brochure page 2, Rack-Mounted Battery table, Working Temperature ( °C ) row
Printed as "50" in the Recommend row of the Charge / Discharge Current ( A ) block of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell the table shares across the BOS-GH40 and BOS-GH60 columns (the BOS-GL60 column prints 100); the row covers both charge and discharge. Footnote 2 reads "The current is affected by temperature and SOC."
Where: Brochure page 2, Rack-Mounted Battery table, Charge / Discharge Current ( A ), Recommend row
Printed as "Module Nominal Voltage ( V ) 51.2" in Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), read from the rendered page 2 table, in a cell the table shares across the BOS-GL60, BOS-GH40 and BOS-GH60 columns; this is the voltage of one module, not of the system.
Where: Brochure page 2, Rack-Mounted Battery table, Module Nominal Voltage ( V ) row
575.87 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 530 × H: 1,629 × D: 667 mm / W: 20.9 × H: 64.13 × D: 26.3 in433 kg / 955 lb0.07 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
62/100Missing details85% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
High voltage · Server rack · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
CertificatesCEC · UL 1973 +3CEC listed45 / 45
100 evidence points · 45% weight
CEC listing: full credit for the certificate criterion. Exact model found in the dated CEC equipment list. This is not a safety certification or system approval. Applies: CEC; UL 9540; UL 1973.
Printed as "10 years" in the Warranty row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell shared by all three columns; footnote 3 reads "The warranty is due whichever reached first of warranty period or life cycle power." The warranty terms document was not read.
Research pending, 0 points: Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1973manufacturer claimpresent at observation[1]
Scope
battery pack scope unverified
Covered models
BOS-GH40
Limitations
Listed as "UL1973" in the Certification row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0) ("UL1973 / UL9540A / UN38.3 / UL9540"), in a cell shared by the BOS-GL60, BOS-GH40 and BOS-GH60 columns. A manufacturer claim: the brochure names no certificate number, and no issuer record was checked; it does not say whether it covers the cell, the module or the system.
UL 9540manufacturer claimpresent at observation[1]
Scope
battery pack scope unverified
Covered models
BOS-GH40
Limitations
Listed as "UL9540" in the Certification row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0) ("UL1973 / UL9540A / UN38.3 / UL9540"), in a cell shared by the BOS-GL60, BOS-GH40 and BOS-GH60 columns. A manufacturer claim: the brochure names no certificate number, and no issuer record was checked; it does not say whether it covers the cell, the module or the system.
UL 9540Amanufacturer claimpresent at observation[1]
Scope
battery pack scope unverified
Covered models
BOS-GH40
Limitations
Listed as "UL9540A" in the Certification row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0) ("UL1973 / UL9540A / UN38.3 / UL9540"), in a cell shared by the BOS-GL60, BOS-GH40 and BOS-GH60 columns. A manufacturer claim: the brochure names no certificate number, and no issuer record was checked; it does not say whether it covers the cell, the module or the system.
UN 38.3manufacturer claimpresent at observation[1]
Scope
battery pack scope unverified
Covered models
BOS-GH40
Limitations
Listed as "UN38.3" in the Certification row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0) ("UL1973 / UL9540A / UN38.3 / UL9540"), in a cell shared by the BOS-GL60, BOS-GH40 and BOS-GH60 columns. A manufacturer claim: the brochure names no certificate number, and no issuer record was checked; it does not say whether it covers the cell, the module or the system.
UL 1973authority listing reportedlisted as of snapshot[2]
Scope
equipment listing
Covered models
BOS-GH40
Limitations
Listed on the California Energy Commission Battery List (data unchanged since October 1, 2026; downloaded October 11, 2026) as NINGBO DEYE ESS TECHNOLOGY CO., LTD "BOS-GH40": UL 1973, certifying entity SGS, certificate date 2024-04-19, Ed. 2 : 2018, CEC listing date 2024-07-22. A state equipment list entry, not the certification body's own record.
CECauthority listing reportedlisted as of snapshot[2]
Scope
equipment listing
Covered models
BOS-GH40
Limitations
Model BOS-GH40 listed on the California Energy Commission Battery List (data unchanged since October 1, 2026; downloaded October 11, 2026) under NINGBO DEYE ESS TECHNOLOGY CO., LTD, as "BOS-GH40", CEC listing date 2024-07-22. This is an equipment listing, not UL certification or complete-system approval.
Printed as "10 years" in the Warranty row of Deye's BOS-GL60 & BOS-GH60 series brochure for North America (20260707 v1.0), in a cell shared by all three columns; footnote 3 reads "The warranty is due whichever reached first of warranty period or life cycle power." The warranty terms document was not read.
Numeric columns did not yield extractable text; no fact cites this file.
Location: Rack-mounted battery model table: BOS-GL60 / BOS-GH40 / BOS-GH60
Retrieved Sep 19, 2026
North American brochure PDF for the BOS-GL60 and BOS-GH60, archived 20 September 2026. Row labels extract but the numeric columns are set in embedded fonts that did not extract reliably, so no numeric value here is read from it; it establishes only that the North American names of this family are BOS-GL60, BOS-GH40 and BOS-GH60.
Archived copies
Archived copy of a document published by Ningbo Deye Technology. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Deye BOS-GL60 & BOS-GH60 series brochure, North America, 2026-07-07 v1.0
Archived copy of a document published by Ningbo Deye Technology. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
BOS-GH40
Manufacturer SKU BOS-GH40 · US market
Observed Oct 11, 2026
UL 1973: claimed
Product / system scope unresolved. Listed on the California Energy Commission Battery List (data unchanged since October 1, 2026; downloaded October 11, 2026) as NINGBO DEYE ESS TECHNOLOGY CO., LTD "BOS-GH40": UL 1973, certifying entity SGS, certificate date 2024-04-19, Ed. 2 : 2018, CEC listing date 2024-07-22. A state equipment list entry, not the certification body's own record.
Product / system scope unresolved. Model BOS-GH40 listed on the California Energy Commission Battery List (data unchanged since October 1, 2026; downloaded October 11, 2026) under NINGBO DEYE ESS TECHNOLOGY CO., LTD, as "BOS-GH40", CEC listing date 2024-07-22. This is an equipment listing, not UL certification or complete-system approval.
note: CEC listing: full credit for the certificate criterion. Exact model found in the dated CEC equipment list. This is not a safety certification or system approval. Applies: CEC; UL 9540; UL 1973.