Charged ReviewsSaved 0Compare 0Login
AIMS Power PIHY4600 4.6kW Hybrid Inverter Charger
AIMS Power
Hybrid inverter

AIMS Power PIHY4600 4.6kW Hybrid Inverter Charger

Key specs

Weight24.04 kg / 53 lb converted
Continuous output4.6 kW
Max PV voltage660 V
Efficiency97.6 %
Max charge50 A
PV start voltage100 V

All specifications

Identity

BrandAIMS Power · Website
ModelPIHY4600
MarketUS
Manufacturer SKUPIHY4600
About brandDesigns and sells off-grid and renewable energy equipment: DC to AC inverters, solar panels, deep-cycle batteries, solar charge controllers, cables, fuse kits and portable generators. AIMS Power says it was founded by Bruce de Jong, who built its first inverter in 2001.
SKU detail
locator: Store page Quick Comparison, SKU row; manual cover
conditions: AIMS Power's store page prints SKU PIHY4600 (first column of its Quick Comparison table, the page's own product) and heads its Specifications tab with PIHY4600; the manual cover prints "PART #: PIHY4600 & PIHY9600".
Sources: [1] [2]
FieldValueConditionsSource
Weight24.04 kg / 53 lb converted
The PIHY4600 store page's Additional information table prints "Weight" as "53 lbs"; converted to kilograms. The page does not say whether it is the unit or the shipping weight.
Where: Store page Additional information table, Weight
Sources
Converted: 53 lb x 0.45359237 = 24.04 kg
[1]
Peak output6.9 | 6.9 kVA (10 min)
The manual prints "Max Peak Power(kVA)(10 min)" as "6.9 | 6.9" and "Max Peak Currenty (A)(10 min)" as "28.8 | 33.2" in the PIHY4600 column; the store page prints the same rows. The two figures are kept as printed.
Where: Manual PDF page 57, Specifications, AC BACK-UP & GENERATOR, Max Peak Power(kVA)(10 min), PIHY4600 column
[2] [1]
Voltage thd<3%
The manual and the store page print "Voltage THD(%)" as <3.
Where: Manual PDF page 57, Specifications, Voltage THD(%)
[2] [1]
AC voltage240 | 208 V L-L (not 3 phase); 120 V L-N
The manual prints the back-up output as "240 | 208 (not 3 phase)" line to line and "120 | 120" line to neutral, once across both columns; the store page prints "Nominal AC Voltage L-L(V) 240 | 208 (not 3 phase) Nominal AC Voltage L-N(V) 120 | 120".
Where: Manual PDF page 57, Specifications, AC BACK-UP & GENERATOR, Nominal AC Voltage L-L(V) and L-N(V)
[2] [1]
Max charge50 A
The manual prints "Max Charge/Discharge Current(A)" as 50, once across both columns; the store page prints "Max Charge/Discharge Current(A) 50". The battery port is the high-voltage DC port (230 V nominal).
Where: Manual PDF page 57, Specifications, Max Charge/Discharge Current(A)
[2] [1]
CommunicationsRS485; CAN; Wi-Fi
The manual prints "Ful Color LED, RS485, CAN, Wi-Fi" (sic) and the store page "Display & Communication Interfaces Full Color LED, RS485, CAN, Wi-Fi". The page's features also list 4G, and the manual names a Wi-Fi/GPRS/LAN module; only the table row is recorded.
Where: Manual PDF page 57, Specifications, Display & Communication Interfaces
[2] [1]
Cooling methodNatural Convection
The manual prints "Natural Convection" in the PIHY4600 column ("Thermal Fan" for the PIHY9600); the store page prints "Cooling Natural Convection".
Where: Manual PDF page 57, Specifications, Cooling, PIHY4600 column
[2] [1]
Efficiency97.6 %
The store page prints "Max Efficiency(%) 97.6"; the manual's table prints the same figure (read from the page image). PV to battery efficiency is printed as 98.1%.
Where: Store page Specifications tab, Max Efficiency(%); manual PDF page 57
[1] [2]
MPPT voltage80 to 550 V
The manual prints "MPPT Range (V)" as 80-550, once across both columns; the store page prints "MPPT Range (V) 80-550". The nominal PV voltage is printed as 360 V.
Where: Manual PDF page 57, Specifications, MPPT Range (V)
[2] [1]
Solar input6.9 kW
The manual prints "Max Input Power (kW)" as 6.9 in the PIHY4600 column; the store page prints "Max Input Power (kW) 6.9".
Where: Manual PDF page 57, Specifications, Max Input Power (kW), PIHY4600 column
[2] [1]
AC frequency60 Hz
The manual prints 60 Hz for the grid and the back-up output, once across both columns; the store page prints "Nominal Grid Frequency (Hz) 60".
Where: Manual PDF page 57, Specifications, Nominal Grid Frequency (Hz); Nominal AC Frequency(Hz)
[2] [1]
Max discharge50 A
One figure printed for charge and discharge: "Max Charge/Discharge Current(A) 50".
Where: Manual PDF page 57, Specifications, Max Charge/Discharge Current(A)
[2] [1]
AC configuration211 to 264 @ 240 | 183 to 229 @ 208 (not 3 phase, split phase)
The manual prints "Nominal Grid Voltage (V)" as "211 to 264 @ 240 | 183 to 229 @ 208 (not 3 phase, split phase)", once across both columns; the store page prints the same row.
Where: Manual PDF page 57, Specifications, AC GRID, Nominal Grid Voltage (V)
[2] [1]
AC input breaker25A/240V/208V AC breaker
The manual's AC breaker table prints "Inverter Model PIHY4600 PIHY9600 25A/240V/208V AC breaker 50A/240V/208V AC breaker"; 25 A is the PIHY4600 figure.
Where: Manual AC Connection (PDF page 28), AC breaker specification, PIHY4600
[2]
Enclosure ratingIP65 | NEMA4X
The manual prints "IP 65 | NEMA4X"; the store page prints "Enclosure Protect Level IP65 | NEMA4X".
Where: Manual PDF page 57, Specifications, Enclosure Protect Level
[2] [1]
Max PV current15.5 A x 2
The manual prints "Max Input Current (A)" as "15.5 x 2" in the PIHY4600 column; the store page prints the same. The number of MPPT trackers is not printed for this model (the manual says the series allows up to three PV MPPT inputs), so no MPPT count is recorded.
Where: Manual PDF page 57, Specifications, Max Input Current (A), PIHY4600 column
[2] [1]
Max PV voltage660 V
The manual's table prints "Max PV Voltage (V)" as 660, once across both columns; the store page's Specifications tab prints "Max PV Voltage (V) 660".
Where: Manual PDF page 57, Specifications, Max PV Voltage (V)
[2] [1]
Transfer time<10 ms
The manual prints "Switching Time(ms)" as <10, once across both columns; the store page prints "Switching Time(ms) <10".
Where: Manual PDF page 57, Specifications, Switching Time(ms)
[2] [1]
Apparent power4,600 VA
Printed as 4.6 kVA ("Max Continuous Power(kVA) 4.6" on the store page); expressed in VA.
Where: Manual PDF page 57, Specifications, AC GRID, Max Continuous Power(kVA), PIHY4600 column
Sources
Converted: 4.6 kVA x 1000 = 4600 VA
[2] [1]
Nominal voltage230 V
The manual prints "Battery Voltage (V)" as 230, once across both columns; the store page prints "Battery Voltage (V) 230". This is the high-voltage battery port.
Where: Manual PDF page 57, Specifications, Battery Voltage (V)
[2] [1]
Idle consumption<10 W
The manual prints "Stanby Consumption (W)" as <10, once across both columns; the store page prints "Stanby Consumption (W) <10".
Where: Manual PDF page 57, Specifications, Stanby Consumption (W)
[2] [1]
Max parallel units6
The store page's features print "Stackable (Max 6)"; the manual's table does not print a parallel limit.
Where: Store page Features
[1]
PV start voltage100 V
The manual prints "Startup Voltage" as 100, once across both columns; the store page prints "Startup Voltage 100".
Where: Manual PDF page 57, Specifications, Startup Voltage
[2] [1]
Operating noise<25 dB
The manual prints "Noise Emission (dB)" as <25 in the PIHY4600 column; the store page prints "Noise Emission (dB) <25".
Where: Manual PDF page 57, Specifications, Noise Emission (dB), PIHY4600 column
[2] [1]
Certification claimsUL 1741 SA; CSA 2202 No. 107-01; UL 1998; Rules21; HECO Rule 14; CEC; FCC Part 15 Class B
AIMS Power's claims as printed in the manual and on the store page: "UL 1741 SA | CSA 2202 No. 107-01 |UL 1998 | Rules21 | HECO Rule 14 | IP65 | CEC" (the manual's row runs off the table edge) and EMC "FCC Part 15 Class B". The page's features print "Listed to UL 1741-SA I CSA 22.2 No.107-01 I UL1998 I UL1699B". No certificate or listing record was read.
Where: Manual PDF page 57, Specifications, Certification & Approvals; EMC; store page Features
[2] [1]
Continuous output4.6 kW
The manual heads its first column "PIHY4600 4600 WATT (4.6 kW)" and prints "Max Continuous Power(kVA)" as 4.6 for the grid and the back-up output; the store page prints "PIHY4600 – 4600 WATT (4.6kW)" and "Max Continuous Power(kVA) 4.6".
Where: Manual PDF page 57, Specifications, PIHY4600 column heading; AC GRID and AC BACK-UP, Max Continuous Power(kVA)
[2] [1]
Mounting orientationWall bracket, upright position
The manual's table prints "Wall Bracket"; its installation section says "Install the inverter on a wall or stable structure, in a upright position."
Where: Manual PDF page 57, Specifications, Mounting; Installation (PDF page 17)
[2] [1]
Battery compatibilityLithium | Lead (if using non AIMS lithium batteries requires custom programming)
The manual's table prints "Lithium | Lead (if using non AIMS lithium batteries requires custom programming)"; its battery section says "The PIHY inverters are compatible with AIMS Power lithium batteries only (Part #s: LFP230V96A-M & LFP230V96A-S)", that they are also compatible with all lead acid battery types (gel, AGM, open), and that another lithium battery requires contacting AIMS Power tech support first.
Where: Manual PDF page 57, Specifications, Battery Type; Battery Connection (PDF page 27)
[2] [1]
Battery efficiency96.8 %
Printed as "Battery to AC Efficiency(%)" 96.8, once across both columns.
Where: Manual PDF page 57, Specifications, Battery to AC Efficiency(%)
[2] [1]
Max PV short circuit26 A x 2
The manual prints "Max Short Current (A)" as "26 x 2" in the PIHY4600 column; the store page prints "Max Short Current (A) 26 x 2".
Where: Manual PDF page 57, Specifications, Max Short Current (A), PIHY4600 column
[2] [1]
Battery voltage range80 to 495 V
The manual prints the battery voltage range as 80- 495 V, once across both columns, and the store page prints "Battery Voltage Range(V) 80- 495".
Where: Manual PDF page 57, Specifications, Battery Voltage Range (V)
[2] [1]
Operating temperature-25 to 60 °C / -13 to 140 °F converted
The manual prints "-25 to 60C | -77 to 140F", once across both columns, and the store page prints the same; the Celsius range is recorded. The Fahrenheit lower figure as printed (-77 F) does not match -25 C (-13 F).
Where: Manual PDF page 57, Specifications, Operating Temperature Range
[2] [1]
Weighted efficiency97 %
The store page prints "CEC Efficiency(%) 97"; the manual's table prints the same figure once across both columns (read from the page image).
Where: Store page Specifications tab, CEC Efficiency(%); manual PDF page 57
[1] [2]
Maximum continuous output19.5 | 22.5 A
The manual prints "Max Continuous Current(A)" as "19.5 | 22.5" for the grid and the back-up output in the PIHY4600 column, in the same order as the voltage row's "240 | 208"; the store page prints the same.
Where: Manual PDF page 57, Specifications, AC GRID and AC BACK-UP & GENERATOR, Max Continuous Current(A), PIHY4600 column
[2] [1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
4.6 kW
Battery voltage
80 to 495 V
Solar input
6.9 kWMPPT trackers Not statedMPPT range 80 to 550 V
AC output
211 to 264 @ 240 | 183 to 229 @ 208 (not 3 phase, split phase)
Warranty
10 years
Size
UnknownWeight 24.04 kg / 53 lb

Evidence score

39/100Missing details90% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

CertificatesUL 1741 SAClaimed12.6 / 45.0

Manufacturer claim; issuer verification pending. Applies to the exact inverter.

[3]

Warranty term10 years12.0 / 30.0

10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

The manual's table prints "10 Year Limited" and its introduction "Backed by a 10 year warranty and lifetime tech support."; the store page's features print "10 year warranty".

[2] [1]

Battery conversion efficiency96.8 %14.8 / 15.0

96.8 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10

Printed as "Battery to AC Efficiency(%)" 96.8, once across both columns.

[2] [1]

Idle consumption<10 · not confirmed0.0 / 10.0

The manual prints "Stanby Consumption (W)" as <10, once across both columns; the store page prints "Stanby Consumption (W) <10".

A value is on file but is not counted: it carries a warning or is not confirmed.

[2] [1]

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL 1741 SAauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
PIHY4600
Limitations
On the CEC list as certified to UL 1741 SA. California Energy Commission official workbook checked November 6, 2026 Pacific (November 7 UTC). Solar_Inverters row 161, PIHY4600 {240V}; Battery_Inverters row 25, PIHY4600 {240V}. The SA8-SA13 flag (column E) and the certification group at Q:S were read together; a testing flag alone is insufficient. This reported claim is limited to SA8-SA13 and the voltage configurations in these rows. This is CEC-reported equipment evidence, not an issuer listing verification. No lab/file number, installation approval, regional transfer or complete-kit certification is established. Other maker claims and historical evidence remain separate.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Nov 6, 2026
Source
[3]

Warranty

FieldValueConditionsSource
Warranty term10 years
The manual's table prints "10 Year Limited" and its introduction "Backed by a 10 year warranty and lifetime tech support."; the store page's features print "10 year warranty".
Where: Manual PDF page 57, Specifications, Warranty; Product Introduction (PDF page 6)
[2] [1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Hybrid Power Inverter manual, Part #: PIHY4600 & PIHY9600 (AIMS Power, file AIMS-Power-Hybrid-110823-1)Official · AIMS Power · Official user manual · PDF
    Source details
    Revision
    110823
    Revision date
    Not stated

    Archived copy captured on 2026-10-17.

    Location: Cover; Product Introduction (PDF page 6); Product Overview (PDF page 16); PV Connection (PDF page 26); AC Connection (PDF page 28); Specifications (PDF page 57)

    Retrieved Oct 16, 2026

    AIMS Power's manual for its two hybrid inverters, PIHY4600 and PIHY9600 (file name AIMS Power Hybrid 110823), linked from the Manual tab of both store pages, captured on October 17, 2026. Its Specifications table (PDF page 57) and Product Overview drawing (PDF page 16) are images with no text layer; they were read from the page images. The table has a PIHY4600 column and a PIHY9600 column, with rows that apply to both printed once across the two; where a row prints two figures separated by a bar, they are kept together as printed. The Product Overview drawing is printed once for the manual and names no model. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 3.08 MB

    Archived copy, unaltered, kept as a record of what AIMS Power published. Original address: https://www.aimscorp.net/wp-content/uploads/2023/07/AIMS-Power-Hybrid-110823-1.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    57

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: d1798d0fd7aefb8918bca7d6f3fe5a977e2a7c1d16c206811f6eb6a7a4450474

    Open
  • Other documents

  • AIMS Power PIHY4600 hybrid inverter charger store page (October 17, 2026 capture)Official · AIMS Power · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-17.

    Location: Features; Manual; Specifications; Quick Comparison, SKU row

    Retrieved Oct 16, 2026

    AIMS Power's own store page on aimscorp.net, captured on October 17, 2026; the content is whatever the address served on that date. Its Specifications tab reproduces the manual's table for this model only; its Features list and Additional information table are read for this SKU only, and the Quick Comparison table lists other models and is read only in this SKU's column. The page carries no revision date. Manufacturer claims, not independent tests.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Hybrid Power Inverter manual, Part #: PIHY4600 & PIHY9600 (AIMS Power, file AIMS-Power-Hybrid-110823-1)

Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 3.08 MB

Archived copy, unaltered, kept as a record of what AIMS Power published. Original address: https://www.aimscorp.net/wp-content/uploads/2023/07/AIMS-Power-Hybrid-110823-1.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
57

Embedded dates are file metadata, not independent proof of publication.

SHA-256: d1798d0fd7aefb8918bca7d6f3fe5a977e2a7c1d16c206811f6eb6a7a4450474

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
PIHY4600

Manufacturer SKU PIHY4600 · US market

  1. Observed Nov 6, 2026

    UL 1741 SA: claimed

    Product / system scope unresolved. On the CEC list as certified to UL 1741 SA. California Energy Commission official workbook checked November 6, 2026 Pacific (November 7 UTC). Solar_Inverters row 161, PIHY4600 {240V}; Battery_Inverters row 25, PIHY4600 {240V}. The SA8-SA13 flag (column E) and the certification group at Q:S were read together; a testing flag alone is insufficient. This reported claim is limited to SA8-SA13 and the voltage configurations in these rows. This is CEC-reported equipment evidence, not an issuer listing verification. No lab/file number, installation approval, regional transfer or complete-kit certification is established. Other maker claims and historical evidence remain separate.

    [3]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 90
basis: Unknown
missing:
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 28
unit: Unknown
shown: UL 1741 SA
shown detail: Claimed
state: claimed
points: 12.6
ceiling: 45
weight: 45
share: 28
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Manufacturer claim; issuer verification pending. Applies to the exact inverter.
display note: Unknown
Sources: [3]
key: warranty
label: Warranty term
value: 10
unit: Unknown
shown: 10 years
shown detail: Unknown
state: documented
points: 12
ceiling: 30
weight: 30
share: 40
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2] [1]
key: efficiency
label: Battery conversion efficiency
value: 96.8
unit: Unknown
shown: 96.8 %
shown detail: Unknown
state: documented
points: 14.8
ceiling: 15
weight: 15
share: 98.6
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2] [1]
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: <10 · not confirmed
shown detail: Unknown
state: unconfirmed
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: no
reason: not-counted
reason text: A value is on file but is not counted: it carries a warning or is not confirmed.
note: Not documented.
display note: Unknown
Sources: [2] [1]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. AIMS Power PIHY4600 hybrid inverter charger store page (October 17, 2026 capture) (AIMS Power · manufacturer · observed Oct 16, 2026)
  2. Hybrid Power Inverter manual, Part #: PIHY4600 & PIHY9600 (AIMS Power, file AIMS-Power-Hybrid-110823-1) (AIMS Power · manufacturer · observed Oct 16, 2026)
  3. California Energy Commission InvertersList full official workbook, data 2026-10-21 (California Energy Commission · government equipment registry · Data unchanged since 2026-10-21 · observed Nov 6, 2026 · effective Oct 21, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details