About brandRubix Battery makes stackable LiFePO4 battery modules for residential and light commercial solar storage, including the Stack Series and the R-Series; the earlier Giga Stack Series is discontinued. Its documents describe Rubix as a product of Ark Battery and MillerTech.
Each battery includes a green grounding busbar; batteries should be grounded together and connected to the system's earth ground
Printed as "Each battery includes a green grounding busbar"; "Batteries should be grounded together and connected to the system" in the Stack Series Owner's Manual, Rubix Battery (PDF page 15, Cabling & Paralleling Batteries).
Where: PDF page 15, Cabling & Paralleling Batteries
Printed as "Rated Cycle Life (80% DoD) 6,000 Cycles". The 100% DoD row prints 4,500 cycles and the 50% DoD row 8,000 cycles. Retained capacity at end of cycle life is printed as 80%.
Printed as "Cell Chemistry LiFePO4 Cell Format Prismatic" in the Stack Series Owner's Manual, Rubix Battery (PDF page 35, General Specifications, Internal Components).
Where: PDF page 35, General Specifications, Internal Components
Printed as "Peak Discharge Power (3 sec) 400A (10�2kW)" in the Stack Series Owner's Manual, Rubix Battery (PDF page 36, General Specifications, Charging/Discharging). Peak discharge for 3 seconds.
Where: PDF page 36, General Specifications, Charging/Discharging
W 490.22 × H 157.48 × L 574.04 mm / W 19.3 × H 6.2 × L 22.6 in converted
Printed as "Battery 22.6” × 19.3” × 6.2”" in inches; the base and lid are printed separately. The inch figures are the printed values; the millimeter figures are their exact conversion, not rounded.
Where: Dimensions
Sources
Converted: 22.6 x 19.3 x 6.2 in x 25.4 mm/in = 574.04 x 490.22 x 157.48 mm (exact; not rounded)
Printed as "Terminal Specs M8 Stainless Steel Bolt-On" in the Stack Series Owner's Manual, Rubix Battery (PDF page 34, General Specifications, Installation Requirements).
Where: PDF page 34, General Specifications, Installation Requirements
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "Rubix Stack batteries are designed to stack on top of each other. Follow this sequence to stack your batteries.". Classified as Stackable from the maker's own words for this model.
Set a unique address for each battery on the LCD Settings screen, beginning with 0 for the master battery, then 1, 2 and so on
Printed as "set a unique address for each battery, beginning with 0 for the master" in the Stack Series Owner's Manual, Rubix Battery (PDF page 21, Communication With Inverters).
Printed as "Energy Rating 25.6V 200Ah (5.12kWh)" in the specification sheet; the owner's manual prints the same row. The product page prints "Nominal Voltage : 25.6V".
Printed as "Never connect Stack batteries in series"; "Do not connect Rubix batteries in series to create a higher pack voltage!" in the Stack Series Owner's Manual, Rubix Battery (PDF page 14, Cabling & Paralleling Batteries).
Where: PDF page 14, Cabling & Paralleling Batteries
Printed as "• Battery • Wiring Compartment Cover • Paralleling Busbars"; "• Paralleling Network Cable • Terminal Covers" in the Stack Series Owner's Manual, Rubix Battery (PDF page 4, What's Included). The Stack series base and lid kit is purchased separately.
Converted from ft-lbs. The manual prints 18 ft-lbs; the value shown is converted (18 ft-lbf x 1.35582 = 24.4 N·m). The printed value is kept as an alternative.
Printed as "Max Terminal Torque 18 ft-lbs RS25200" in the Stack Series Owner's Manual, Rubix Battery (PDF page 36, General Specifications, Installation Requirements). Maximum terminal torque printed as 18 ft-lbs.
Where: PDF page 36, General Specifications, Installation Requirements
Sources
Converted: 18 ft-lbf x 1.35582 = 24.4 N·m
18 ft-lbs
The value as the manual prints it, in ft-lbs. Printed as "Max Terminal Torque 18 ft-lbs RS25200" in the Stack Series Owner's Manual, Rubix Battery (PDF page 36, General Specifications, Installation Requirements). Maximum terminal torque printed as 18 ft-lbs.
Printed as "Battery Daisy-Chaining (RS485 Networking) CANBUS Port RS485 Computer Connection" in the Stack Series Owner's Manual, Rubix Battery (PDF page 6, Wiring Compartment Guide).
Printed as "Installation Position Horizontal with Base Unit Only" in the Stack Series Owner's Manual, Rubix Battery (PDF page 34, General Specifications, Installation Requirements).
Where: PDF page 34, General Specifications, Installation Requirements
Sol-Ark, Schneider Electric, Megarevo, MidNite Solar, Deye, EG4, Victron Energy, Outback Power, SRNE Solar, Magnum Energy (listed as compatible inverters; the manual says the list is not comprehensive or exclusive and does not denote closed-loop communication compatibility)
Printed as "The following inverters are compatible with Rubix batteries"; "• Sol-Ark • Schneider Electric • Megarevo • MidNite Solar • Deye • EG4"; "• Victron Energy • Outback Power • SRNE Solar • Magnum Energy"; "This list does not denote closed loop communication compatibility" in the Stack Series Owner's Manual, Rubix Battery (PDF page 22, Inverter Compatibility).
Printed as "Closed-loop communication with inverters is accomplished through CANBUS" in the Stack Series Owner's Manual, Rubix Battery (PDF page 23, Closed Loop Installation (48V)).
Where: PDF page 23, Closed Loop Installation (48V)
Printed as "Minimum Environment Temp 32 °F" and "Maximum Environment Temp 120 °F" (installation environment). The BMS low temperature charging disconnect is printed as 32 °F and the high temperature disconnect as 135 °F.
Where: Installation Requirements, Minimum and Maximum Environment Temp
Sources
Converted: (32 °F - 32) x 5/9 = 0 °C; (120 °F - 32) x 5/9 = 48.9 °C, rounded to 0.1 °C
44.32 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 490.22 × H: 157.48 × L: 574.04 mm / W: 19.3 × H: 6.2 × L: 22.6 in48.99 kg / 108 lb0.12 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
17/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
24 V · Stackable · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1973manufacturer claimpresent at observation[1][3][2]
Scope
cell
Covered models
RS25200
Limitations
A manufacturer claim, not a listing or certificate. Printed as "Cell Certification UL 1973" under Certifications on page 3 of Rubix's Stack Series 24V specification sheet (version 3.1) for RS25200, captured October 2, 2026. The same Certifications block of the Stack Series Owner's Manual (11617, 2026-01, page 37, the RS25200 table) prints a dash and no standard after "Battery Certification", and Rubix's own Stack Series page prints "Certifications : UL 1973 (UL 9540A and UL 9540DC ESS pending)" in the 24V/200AH Key Specs without saying what it covers; the claim is recorded at the cell scope the specification sheet gives. No issuer, certificate or report number is printed; the issuer's record was not checked. Cell scope: a claim about the cells does not certify the assembled battery.
UL 1973Manufacturer claim · cellClaimedListed when checked
A manufacturer claim, not a listing or certificate. Printed as "Cell Certification UL 1973" under Certifications on page 3 of Rubix's Stack Series 24V specification sheet (version 3.1) for RS25200, captured October 2, 2026. The same Certifications block of the Stack Series Owner's Manual (11617, 2026-01, page 37, the RS25200 table) prints a dash and no standard after "Battery Certification", and Rubix's own Stack Series page prints "Certifications : UL 1973 (UL 9540A and UL 9540DC ESS pending)" in the 24V/200AH Key Specs without saying what it covers; the claim is recorded at the cell scope the specification sheet gives. No issuer, certificate or report number is printed; the issuer's record was not checked. Cell scope: a claim about the cells does not certify the assembled battery.
Rubix Battery's Stack Series owner's manual, linked from the Stack Series page. Its General Specifications section prints one table per model, RS51100 and RS25200. In the text layer of this PDF the decimal point is not a standard character, so decimal figures are checked against the specification sheets.
Archived copies
Archived copy of a document published by Rubix Battery. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Rubix Battery's Stack Series 24V specification sheet (version 3.1) for model RS25200.
Archived copies
Archived copy of a document published by Rubix Battery. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Rubix Battery's warranty policy for Stack batteries, linked from the Stack Series page.
Archived copies
Archived copy of a document published by Rubix Battery. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Stack Series Owner's Manual, Rubix Battery
Archived copy of a document published by Rubix Battery. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Stack Series 24V specification sheet, version 3.1, Rubix Battery
Archived copy of a document published by Rubix Battery. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Rubix Battery. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
RS25200
Manufacturer SKU RS25200
Observed Oct 2, 2026
UL 1973: claimed
Cell / component only. A manufacturer claim, not a listing or certificate. Printed as "Cell Certification UL 1973" under Certifications on page 3 of Rubix's Stack Series 24V specification sheet (version 3.1) for RS25200, captured October 2, 2026. The same Certifications block of the Stack Series Owner's Manual (11617, 2026-01, page 37, the RS25200 table) prints a dash and no standard after "Battery Certification", and Rubix's own Stack Series page prints "Certifications : UL 1973 (UL 9540A and UL 9540DC ESS pending)" in the 24V/200AH Key Specs without saying what it covers; the claim is recorded at the cell scope the specification sheet gives. No issuer, certificate or report number is printed; the issuer's record was not checked. Cell scope: a claim about the cells does not certify the assembled battery.
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.