Charged ReviewsSaved 0Compare 0Login
No photo yet
Magnum Energy
Inverter charger

Magnum Energy MSH4024M Pure Sine Inverter/Charger

Key specs

Weight24.9 kg / 54.9 lb converted
Nominal voltage24 V
Efficiency93.7 %
Continuous output4 kW
Converted: 4000 W / 1000 = 4 kW
Max charge110 A
AC frequency60 Hz

All specifications

Identity

BrandMagnum Energy · Website
ModelMSH4024M
MarketUS
Manufacturer SKUMSH4024M
About brandMagnum Series inverters and inverter/chargers, including the MS, MS-PAE and MSH-RV Series, are published by DMX Power, LLC on dmx-power.com, where the catalog pages mark them Made in USA. DMX Power's Limited Warranty Policy names Magnum Series Inverters and Inverter Chargers among its products and says DMX Power makes power inverters for recreational vehicle, marine, fleet, renewable energy and off-grid systems.
SKU detail
locator: Page Models & Specifications tables; PDF page 52, specifications table heading
conditions: Model number as printed in the DMX Power MSH-M Series page tables and in the heading of the owner's manual's specifications table (its Appendix A table heads its columns MSH3012M and MSH4024M).
Sources: [1] [2]
FieldValueConditionsSource
Weight24.9 kg / 54.9 lb converted
Unit weight, printed as "55 lb (24.9 kg)" in the Weight row, printed once for every model of the table; the kilogram figure is recorded.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Weight row
[2]
Peak output5800 W for 5 s; 5400 W for 30 s; 4900 W for 5 min; 4500 W for 30 min
The manual's surge rows print 5800 (5 sec), 5400 (30 sec), 4900 (5 min) and 4500 (30 min) for this model (the MSH4024M column).
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, 5 sec surge power (real watts) row
[2]
Voltage thd< 5%
Printed as < 5% in the Total Harmonic Distortion (THD) row, printed once for every model of the table.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Total Harmonic Distortion (THD) row
[2]
AC voltage120 V
Printed as "120 VAC ±3% (≤ continuous power)" in the AC output voltage accuracy row, printed once for every model of the table.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, AC output voltage accuracy row
[2]
Idle standby<7 W searching; 25 W inverting with no load (typical)
Printed as "<7 watts" in the Power consumption – searching row, printed once for every model of the table, and as "25 watts" in the MSH4024M column (column 2 of 2) of the Power consumption – inverting (no load) row.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Power consumption – searching row
[2]
Max charge110 A
Continuous charger output, printed as "110 ADC" in the MSH4024M column (column 2 of 2) of the Continuous charger output at 25°C row.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Continuous charger output at 25°C row
[2]
ClearancesAllow at the minimum an airspace clearance of 6” (15.2 cm) at the intake and exhaust vents, and 3” (7.6 cm) everywhere else to provide adequate ventilation.
Printed as "Allow at the minimum an airspace clearance of 6” (15.2 cm) at the intake and exhaust vents, and 3” (7.6 cm) everywhere else to provide adequate ventilation" in the MSH-M Series Owner's Manual (64-0058 Rev B, April 2023).
Where: PDF page 17, Ventilation
[2]
DimensionsW 321 × H 203 × L 349 mm / W 12.6 × H 7.99 × L 13.7 in converted
Printed as "34.9 cm x 32.1 cm x 20.3 cm" in the Unit dimensions (length x width x height) row, printed once for every model of the table, in the axis order the row names (length x width x height); the centimeter figures are recorded in millimeters.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Unit dimensions (length x width x height) row
Sources
Converted: 34.9 cm x 10 = 349 mm; 32.1 cm x 10 = 321 mm; 20.3 cm x 10 = 203 mm
[2]
Efficiency93.7 %
Peak inverter efficiency, printed as 93.7% in the MSH4024M column (column 2 of 2) of the Inverter efficiency (peak) row.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Inverter efficiency (peak) row
[2]
AC frequency60 Hz
Printed as "60 Hz ± 0.05 Hz" in the Output frequency and accuracy row, printed once for every model of the table.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Output frequency and accuracy row
[2]
Output waveformPure sine wave
Printed as "Output waveform Pure Sine Wave" once for every model of the table.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, waveform row
[2]
Ground wire size#6 AWG (13.3 mm2)
Read from Table 2-1, Recommended DC Wire/Overcurrent Device for Rated Use in the MSH-M Series Owner's Manual (64-0058 Rev B, April 2023), the DC grounding electrode wire size printed for the MSH4024M.
Where: PDF page 23, Table 2-1, Recommended DC Wire/Overcurrent Device for Rated Use, MSH4024M row
[2]
Transfer time16 ms
Printed as "<16 msec" in the AC relay transfer time (minimum) row, printed once for every model of the table.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, AC relay transfer time (minimum) row
[2]
Apparent power4,000 VA
Printed as "4000 VA" in the MSH4024M column (column 2 of 2) of the Continuous power output (at 25°C) row.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Continuous power output (at 25°C) row
[2]
Battery wire size#2/0 AWG (67.4 mm2) (300 amps rating)
Read from the MSH4024M row of Table 2-1, Recommended DC Wire/Overcurrent Device for Rated Use in the MSH-M Series Owner's Manual (64-0058 Rev B, April 2023), the minimum DC wire size for rated use; the table notes copper wire rated with 90°C insulation.
Where: PDF page 23, Table 2-1, Recommended DC Wire/Overcurrent Device for Rated Use, MSH4024M row
[2]
Nominal voltage24 V
Printed as 24 VDC in the DMX Power page's Charging table row for the MSH4024M.
Where: Page Charging table, DC System column
[1]
Surge AC output5,800 W
Printed as 5800 in the MSH4024M column (column 2 of 2) of the 5 sec surge power (real watts) row, the five second surge power.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, 5 sec surge power (real watts) row
[2]
AC terminal torque16 in-lb
Printed as "Torque all AC wiring connections to 16 in lbf (1.8 N-m)" in the MSH-M Series Owner's Manual (64-0058 Rev B, April 2023); 16 in lbf is stored as in-lb.
Where: PDF page 20, 2.3.4 Torque Requirements
[2]
Battery protection300 amps with time delay
Read from the MSH4024M row of Table 2-1, Recommended DC Wire/Overcurrent Device for Rated Use in the MSH-M Series Owner's Manual (64-0058 Rev B, April 2023), the DC overcurrent device for rated use.
Where: PDF page 23, Table 2-1, Recommended DC Wire/Overcurrent Device for Rated Use, MSH4024M row
[2]
Certification claimsETL listed to UL/cUL 458; CSA C22.2 No. 107.1-01; [UL 458:2015 Ed.6]; [CSA C22.2#107.1:2016 Ed.4]
The Safety listings row as printed once for every model of the table. Intertek's Authorization to Mark (issued 17 Apr 2018) names this exact code among the models "MSH4024M, MSH3012M, MSH3012RV" and lists the standards [UL 458:2015 Ed.6] and [CSA C22.2#107.1:2016 Ed.4]. Manufacturer claims; no issuer directory was checked.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Safety listings row
[2] [3]
Continuous output4 kW
Converted: 4000 W / 1000 = 4 kW
Printed as 4000 W continuous on the DMX Power page row for the MSH4024M; the owner's manual prints 4000 VA in the MSH4024M column (column 2 of 2) of the Continuous power output (at 25°C) row. 4000 W expressed in kW.
Where: Page Power & Output table; PDF page 52, MSH-M Series Owner's Manual specifications table, Continuous power output (at 25°C) row
Sources
Converted: 4000 W / 1000 = 4 kW
[1] [2]
Battery compatibilityLead-acid
Printed as battery type "Lead-acid" in the DMX Power page row for the MSH4024M.
Where: Page Power & Output table, Battery column
[1]
Battery terminal torque10 to 12 ft-lb
Printed as "Torque DC cable connections from 10 to 12 ft lbf (13.6 to 16.3 N-m)" in the MSH-M Series Owner's Manual (64-0058 Rev B, April 2023); 10 to 12 ft lbf is stored as ft-lb.
Where: PDF page 20, 2.3.4 Torque Requirements
[2]
Battery voltage range18 to 34 V
Printed as "18.0 to 34.0 VDC" in the MSH4024M column (column 2 of 2) of the Input battery voltage range row.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Input battery voltage range row
[2]
Operating temperature-20 to 60 °C / -4 to 140 °F converted
Operating temperature, printed as "-20°C to +60°C (-4°F to 140°F)" in the Operating temperature row, printed once for every model of the table.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Operating temperature row
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
4 kW
Battery voltage
18 to 34 V
Solar input
Not statedMPPT trackers Not stated
AC output
120 V
Warranty
3 years
Size
22.74 L* (Calculated from published dimensions)W: 321 × H: 203 × L: 349 mm / W: 12.6 × H: 7.99 × L: 13.7 inWeight 24.9 kg / 54.9 lb

Evidence score

4/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term3 years3.6 / 30.0

3 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "3 yr Warranty" in the headline figures of the DMX Power family page, for the family.

[1]

Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
Warranty term3 years
Printed as "3 yr Warranty" in the headline figures of the DMX Power family page, for the family.
Where: Page headline figures
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • MSH-M Series Owner's Manual, 64-0058 Rev B, April 2023 (Sensata Technologies)Official · Sensata Technologies · Official instruction manual · April 2023 · PDF
    Source details
    Revision
    64-0058 Rev B
    Revision date
    April 2023

    Archived copy captured on 2026-10-09.

    Location: Appendix A, A-1 Inverter/Charger Specifications (printed page 43)

    Retrieved Oct 9, 2026

    The MagnaSine Hybrid Mobile Series (MSH-M) owner's manual, published in April 2023 by Sensata Technologies, which then made the Magnum products; DMX Power links it from the MSH3012M page. Figures are read from the MSH3012M column (the first of two) of its Appendix A specification table (printed page 43). Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by Sensata Technologies. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup64-0058 Rev B · 4.09 MB

    Archived copy, unaltered, kept as a record of what Sensata Technologies published. Original address: https://dmx-power.com/sites/default/files/product/manual/sensata-msh-m-series-inverter-charger-manual.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2023-04

    Embedded creation date
    Embedded modification date
    Pages
    64

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 6ac52997c09f85d938e2d3d2f782cd2f88ce4d12fc1e54a3afe98e136c848ba3

    Open
  • Other documents

  • Intertek Authorization to Mark, MSH4024M, MSH3012M and MSH3012RV, UL 458 (issued 17 Apr 2018) (November 2, 2026 capture)Official · DMX Power · Official document · PDF
    Source details
    Revision
    Issued 17 Apr 2018
    Revision date
    Not stated

    Linked from DMX Power's MSH Series and MSH-RV Series pages, Certifications column; captured Nov 1, 2026 (archived copy).

    Location: Standard(s), Product and Models fields

    Retrieved Nov 1, 2026

    Intertek's Authorization to Mark for the MSH4024M, MSH3012M and MSH3012RV (UL 458 and CSA C22.2 No. 107.1), linked from DMX Power's MSH Series and MSH-RV Series pages, Certifications column and fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 06:37:43.715 UTC). DMX Power bought the Magnum Energy line in April 2025. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupIssued 17 Apr 2018 · 0.16 MB

    Archived copy, unaltered, kept as a record of what DMX Power published. Original address: https://dmx-power.com/sites/default/files/document/compliance/msh/atm-msh4024m-msh3012m-msh3012rv-ul458-issued-17-apr-2018.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    1

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: d81deb5af7d23b5f4139f601b9cd5a918e4f7eac10758c22785f2309f7027fbe

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • DMX Power MSH Series inverter/charger page (November 2, 2026 capture)Official · DMX Power · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    DMX Power catalog page; captured Nov 1, 2026 (archived copy).

    Location: Models & Specifications tables

    Retrieved Nov 1, 2026

    DMX Power's catalog page for the MSH Series (MSH-M) inverter/chargers, fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 06:13:25.615 UTC). DMX Power bought the Magnum Energy line in April 2025. Manufacturer claims, not independent tests.

    Open

Archived documents

MSH-M Series Owner's Manual, 64-0058 Rev B, April 2023 (Sensata Technologies)

Archived copy of a document published by Sensata Technologies. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup64-0058 Rev B · 4.09 MB

Archived copy, unaltered, kept as a record of what Sensata Technologies published. Original address: https://dmx-power.com/sites/default/files/product/manual/sensata-msh-m-series-inverter-charger-manual.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2023-04

Embedded creation date
Embedded modification date
Pages
64

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 6ac52997c09f85d938e2d3d2f782cd2f88ce4d12fc1e54a3afe98e136c848ba3

Intertek Authorization to Mark, MSH4024M, MSH3012M and MSH3012RV, UL 458 (issued 17 Apr 2018) (November 2, 2026 capture)

Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupIssued 17 Apr 2018 · 0.16 MB

Archived copy, unaltered, kept as a record of what DMX Power published. Original address: https://dmx-power.com/sites/default/files/document/compliance/msh/atm-msh4024m-msh3012m-msh3012rv-ul458-issued-17-apr-2018.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
1

Embedded dates are file metadata, not independent proof of publication.

SHA-256: d81deb5af7d23b5f4139f601b9cd5a918e4f7eac10758c22785f2309f7027fbe

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
MSH4024M

Manufacturer SKU MSH4024M · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 30
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 3
unit: Unknown
shown: 3 years
shown detail: Unknown
state: documented
points: 3.6
ceiling: 30
weight: 30
share: 12
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. DMX Power MSH Series inverter/charger page (November 2, 2026 capture) (DMX Power · manufacturer · observed Nov 1, 2026)
  2. MSH-M Series Owner's Manual, 64-0058 Rev B, April 2023 (Sensata Technologies) (Sensata Technologies · manufacturer · 64-0058 Rev B · observed Oct 9, 2026)
  3. Intertek Authorization to Mark, MSH4024M, MSH3012M and MSH3012RV, UL 458 (issued 17 Apr 2018) (November 2, 2026 capture) (DMX Power · manufacturer · Issued 17 Apr 2018 · observed Nov 1, 2026)

Sign in to report an error on this page

Similar products

All with a price

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

* Missing details