locator: Manual, Validity; datasheet, model columns
conditions: Printed as "SPF 3000TL LVM-24P" in the Validity section of Growatt's SPF 3000TL LVM user manual (Version 4.0) ("This manual is valid for the following devices: SPF 3000TL LVM-24P; SPF 3000TL LVM-48P;") and as a model column of Growatt's SPF 3000TL LVM datasheet. Growatt prints no separate stock keeping number; the model designation is recorded.
Printed as "Net Weight, kg 11.5" in Table 1 of Growatt's SPF 3000TL LVM user manual (Version 4.0), which has one SPF 3000TL LVM column; the datasheet prints 11.5 for both models.
Where: Specifications, Table 1 General Specifications, Net Weight
Printed as "Surge Capacity 2* rated power for 5 seconds"; the datasheet prints "Surge Power 6000VA". Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Printed as "Output Voltage Regulation 120Vac ±5%", a cell shared by both models. Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Where: Specifications, Table 3, Output Voltage Regulation
Printed as "Max Charging Current 140Amp 120Amp" (LVM-24P, LVM-48P); combined utility and solar charging. Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Where: Specifications, Table 4, Joint Utility and Solar Charging, Max Charging Current
Printed as "Model Typical Amperage Cable Size Torque SPF 3000TL LVM 80A 6 AWG 1.4~1.6 Nm" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 12). The table prints a typical amperage of 80A. The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Where: PDF page 12, PV Connection, recommended cable size table
W 350 × H 455 × D 130 mm / W 13.8 × H 17.9 × D 5.12 in converted
Printed as "Dimension, mm 455 x 350 x 130" in Table 1 of Growatt's SPF 3000TL LVM user manual (Version 4.0) (one model column for the SPF 3000TL LVM) and as "130/350/455" (D/W/H) for both models in Growatt's SPF 3000TL LVM datasheet.
Where: Manual Table 1, Dimension, mm; datasheet Dimension (D/W/H) in mm
Install separately a DC circuit breaker between inverter and PV modules
Printed as "please install separately a DC circuit breaker between inverter and PV modules" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 12). The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Growatt documents differ. The user manual (Version 4.0) prints a peak inverter efficiency of 90%; Growatt's SPF 3000TL LVM datasheet prints "Efficiency (Peak) 93%" for both models. The manual value is recorded, as the manual ranks first.
Printed as "Peak Efficiency 90%", a cell shared by both models. Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Printed as "PV Array MPPT Voltage Range 30~115Vdc 60~115Vdc" (LVM-24P, LVM-48P). Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Where: Specifications, Table 4, PV Array MPPT Voltage Range
Read from the rendered page 2 of Growatt's SPF 3000TL LVM datasheet: the Maximum PV Array Power row prints "2000W" in the SPF 3000TL LVM-24P column. The manual prints no array power.
Where: Page 2, SOLAR CHARGER, Maximum PV Array Power
Printed as "Output Frequency 50Hz/60Hz(default)"; 60 Hz is the default and 50 Hz selectable. Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Printed as "Default: 30A, max 60A" (LVM-24P) and "Default: 30A, max 40A" (LVM-48P); the SPF 3000TL LVM-24P maximum is recorded. Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Where: Specifications, Table 4, Utility Charging Mode, Charging Current (UPS)
Printed as "Max PV Charging current 80A", a cell shared by both models. Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Where: Specifications, Table 4, Solar Charging Mode, Max PV Charging current
Printed as "The recommended spec of AC breaker is 40A for 3KVA" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 11). Printed for a separate AC breaker between inverter and AC input power source. The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Where: PDF page 11, AC Input/Output Connection, caution
Printed as "Max. PV Array Open Circuit Voltage 145Vdc", a cell shared by both models. Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Where: Specifications, Table 4, Max. PV Array Open Circuit Voltage
Printed as "Transfer Time 10ms typical, 20ms Max@ Single <30ms @ Parallel" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 43). The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Where: PDF page 43, Specifications, Table 2 Line Mode Specifications, "Transfer Time" row
Printed as "3KVA/3KW" in the manual and "3000VA/ 3000W" in the datasheet. Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Where: Specifications, Table 3, Rated Output Power
Printed as "SPF 3000TL LVM-24P 141A 200AH 1*2AWG 38 6.4 39.2 2~ 3 Nm 2*6AWG" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 7). The row prints maximum amperage 141A and battery capacity 200AH; the cable mm2 column reads 38 and 28. The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Where: PDF page 7, Battery Connection, "Recommended battery cable and terminal size" table, SPF 3000TL LVM-24P row
Printed as "Nominal DC Input Voltage 24Vdc 48Vdc"; the SPF 3000TL LVM-24P value is 24Vdc. Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Where: Specifications, Table 3, Nominal DC Input Voltage
Printed as "Suggested cable requirement for AC wires Model Gauge Torque Value" and "SPF 3000TL LVM 8 AWG 1.4~ 1.6 Nm" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 11). One table for the AC input and output wires. The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Where: PDF page 11, AC Input/Output Connection, "Suggested cable requirement for AC wires" table
Printed as "Suggested cable requirement for AC wires Model Gauge Torque Value" and "SPF 3000TL LVM 8 AWG 1.4~ 1.6 Nm" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 11). The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Where: PDF page 11, AC Input/Output Connection, "Suggested cable requirement for AC wires" table, "Torque Value" column
Printed as "Output Voltage Regulation 120Vac ±5%" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 44). Printed with a regulation of ±5%; one value for both models. The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Where: PDF page 44, Specifications, Table 3 Inverter Mode Specifications, "Output Voltage Regulation" row
Printed as "Suggested cable requirement for AC wires Model Gauge Torque Value" and "SPF 3000TL LVM 8 AWG 1.4~ 1.6 Nm" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 11). One table for the AC input and output wires. The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Where: PDF page 11, AC Input/Output Connection, "Suggested cable requirement for AC wires" table
Printed as "Safety Certification CE" in Table 1 of Growatt's SPF 3000TL LVM user manual (Version 4.0). Manufacturer claim; no issuer record was checked, and no UL listing is printed.
Printed as "Rated Output Power 3KVA/3KW", a cell shared by both models; the datasheet prints "3000VA/ 3000W". Read from the SPF 3000TL LVM-24P column of Growatt's SPF 3000TL LVM user manual (Version 4.0).
Where: Specifications, Table 3 Inverter Mode Specifications, Rated Output Power
The recommended installation position is to be adhered to the wall vertically.
Printed as "The recommended installation position is to be adhered to the wall vertically" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 6). The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Printed as "Nominal Input Voltage 120Vac" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 43). The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Where: PDF page 43, Specifications, Table 2 Line Mode Specifications, "Nominal Input Voltage" row
Printed as "Wire Size Ring Terminal Torque value Cable mm2" and "39.2 2~ 3 Nm" in the Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual (Version 4.0) (PDF page 7). The manual is valid for "SPF 3000TL LVM-24P; SPF 3000TL LVM-48P" (PDF page 3).
Where: PDF page 7, Battery Connection, "Recommended battery cable and terminal size" table, "Torque value" column
20.7 L* (Calculated from published dimensions)W: 350 × H: 455 × D: 130 mm / W: 13.8 × H: 17.9 × D: 5.12 inWeight11.5 kg / 25.4 lb
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
Growatt's own SPF 3000TL LVM user manual (Version 4.0), hosted on Signature Solar's site (a partner store) and linked from the listing as its installation manual, captured October 3, 2026. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Growatt New Energy Technology Co., Ltd. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Growatt's own SPF 3000TL LVM datasheet (Growatt New Energy Technology Co., Ltd), hosted on Signature Solar's site (a partner store) and linked from the listing as its spec sheet, captured October 3, 2026. Manufacturer claims, not independent tests. The text layer loses the table's columns, so the values were read from the rendered page 2.
Archived copies
Archived copy of a document published by Growatt New Energy Technology Co., Ltd. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Growatt Off Grid Solar Inverter SPF 3000TL LVM User Manual, Version 4.0 (Growatt, hosted by Signature Solar)
Archived copy of a document published by Growatt New Energy Technology Co., Ltd. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Growatt SPF 3000TL LVM datasheet, SPF 3000TL LVM-24P and LVM-48P (Growatt New Energy, hosted by Signature Solar)
Archived copy of a document published by Growatt New Energy Technology Co., Ltd. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
SPF 3000TL LVM-24P
Manufacturer SKU SPF 3000TL LVM-24P · US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 0
basis: Unknown
missing:
Certificate evidence needed
Warranty term needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
Community discussions 1
Links to DIY Solar Forum threads. The title is the forum's own words. It is a member's experience, not a Charged test, not a verified fault rate, and not a statement by the maker.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.