Affiliate link. As an Amazon Associate we earn from qualifying purchases. Price as of Nov 7, 2026, 1:40 PM PST, may change
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Victron Energy's 2026-Q3 price list prints article number PMP482305102 on the row for "MultiPlus-II 48/3000/35-50 120V 50/60Hz (UL 1741)" (page 4), this record's product.
Printed as "Peak power 5500 W 6kW/2s 5500 W 5500 W 9000 W 9000 W" in the Victron MultiPlus-II 120V datasheet, captured on September 25, 2026; the 48/3000/35-50 column reads "5500 W".
Exact PMP482305102 dimension drawing Rev03 gives 572 × 277 × 147 mm H × W × D; independently confirmed in captured 120 V datasheet page 2. Its footnote 7 instead identifies non-UL1741 dimensions as 536 × 277 × 147 mm.
8 specs not documented yet: mppt trackers, output voltage distortion, ac voltage, mppt voltage range, pv array limit, pv input limit, emp test evidence, maximum grid chargingHelp fill in ›
Printed as "Peak power 5500 W 6kW/2s 5500 W 5500 W 9000 W 9000 W" in the Victron MultiPlus-II 120V datasheet, captured on September 25, 2026; the 48/3000/35-50 column reads "5500 W".
Printed as "Continuous output power at 25°C 2400W 3.4kW 2400W 2400W" in MultiPlus-II 120V manual, MultiPlus-II 120V manual, section 7 Technical specifications (PDF page 29), "Continuous output power at 25°C" row in W, 48/3000/35-50 column. Revised on 1 October 2026: The MultiPlus-II 120V manual prints 2400W at 25°C for the 48/3000/35-50, the same figure as the datasheet, so the manual becomes the primary citation and the kW value is labeled as a conversion.
Not printed for this model in the documents on file. Revised on 1 October 2026: No Victron document for this model prints that an external solar charge controller is required or gives a solar input figure; the datasheet only shows an external MPPT charge controller in an example system drawing.
Not documented
MPPT voltage range
Not documented
Details
Not printed for this model in the documents on file. Revised on 1 October 2026: No Victron document for this model prints that an external solar charge controller is required or gives a solar input figure; the datasheet only shows an external MPPT charge controller in an example system drawing.
Not documented
PV array limit
Not documented
Details
Not printed for this model in the documents on file. Revised on 1 October 2026: No Victron document for this model prints that an external solar charge controller is required or gives a solar input figure; the datasheet only shows an external MPPT charge controller in an example system drawing.
Not documented
PV input limit
Not documented
Details
Not printed for this model in the documents on file. Revised on 1 October 2026: No Victron document for this model prints that an external solar charge controller is required or gives a solar input figure; the datasheet only shows an external MPPT charge controller in an example system drawing.
Exact PMP482305102 dimension drawing Rev03 gives 572 × 277 × 147 mm H × W × D; independently confirmed in captured 120 V datasheet page 2. Its footnote 7 instead identifies non-UL1741 dimensions as 536 × 277 × 147 mm.
The Victron datasheet and product data print "Protection category IP22"; the MultiPlus-II 120V manual (captured on September 26, 2026) prints "Protection category IP21". Neither document explains the difference.
Printed as "Protection category IP21" for every model in the MultiPlus-II 120V manual, captured on September 26, 2026. The manual lists PMP482305102 as "MultiPlus-II 48/3000/35-50 120V (UL)". Revised on 26 September 2026: The manufacturer manual prints a different value; the owner decided the manual value is shown first and the recorded value stays as a cited alternative.
IP22
Exact model column; manufacturer claim, not independent test.
Printed as "48/3000/35 100 - 400Ah 125A AWG 1 AWG 2/0" (cross-section per positive and negative terminal) in the MultiPlus-II 120V manual, captured on September 26, 2026. The manual lists PMP482305102 as "MultiPlus-II 48/3000/35-50 120V (UL)".
Printed as a programmable relay "which can be set for general alarm, DC under voltage or genset start/stop function" in the MultiPlus-II 120V manual, captured on September 26, 2026. The manual lists PMP482305102 as "MultiPlus-II 48/3000/35-50 120V (UL)".
Printed as the "Minimum wire gauge" row (three-wire 90ºC copper cable) in the MultiPlus-II 120V manual, captured on September 26, 2026. The manual lists PMP482305102 as "MultiPlus-II 48/3000/35-50 120V (UL)".
Printed as "Recommended torque: 12 Nm (M8 nut)" for the battery cable nuts in the MultiPlus-II 120V manual, captured on September 26, 2026. The manual lists PMP482305102 as "MultiPlus-II 48/3000/35-50 120V (UL)".
Printed as the "Minimum wire gauge" row (three-wire 90ºC copper cable) in the MultiPlus-II 120V manual, captured on September 26, 2026. The manual lists PMP482305102 as "MultiPlus-II 48/3000/35-50 120V (UL)".
Printed as the "DC fuse" column of the battery table and "Recommend fuse or circuit breaker" row of the AC table in the MultiPlus-II 120V manual, captured on September 26, 2026. The manual lists PMP482305102 as "MultiPlus-II 48/3000/35-50 120V (UL)".
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
PDF
Current Transformer for MultiPlus-IIOfficialVictron EnergyOfficial datasheet
Source details
Revision
Not stated
Revision date
Not stated
Victron document library entry 12146 (Datasheet).
Location: Datasheet-Current-transformer-EN.pdf
Retrieved
Original manufacturer-hosted PDF preserved byte for byte from the Victron document library, listed by the manufacturer for SKUs PMP482505010, PMP482305010, PMP242305010, PMP482305100, PMP482805000, PMP122305010, PMP483105000, PMP242505010, PMP122305110, PMP122305120, PMP242305100, PMP483150000, PMP122305122, PMP482305102, PMP482305012, PMP482505012, PMP242305102, PMP482505110, PMP122505010, PMP242505110, PMP122505012, PMP482405012, PMP482605012, PMP482505300, PMP482505120. The revision is whatever Victron published at this URL on the access date; no later revision or independent verification is claimed.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Original manufacturer-hosted PDF preserved byte for byte from the Victron document library, listed by the manufacturer for SKUs PMP482305100, PMP482305102. The revision is whatever Victron published at this URL on the access date; no later revision or independent verification is claimed.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Victron Energy price list 2026-Q3 (EUR C, web edition)OfficialVictron Energy B.V.Official document
Source details
Revision
2026-Q3
Revision date
Not stated
Location: Rows by article number
Retrieved
Victron Energy's public 2026-Q3 euro price list, archived on September 23, 2026. It is the one manufacturer document that prints each product name beside its article number in visible text, with an "H x W x D" size column in millimetres and a "kg" column, so every ordering code in this manifest is checked against it. It is read for identity and, where noted, for size; no price is recorded from it. Its size figures for the 1000 A and 2000 A SmartShunts differ from the datasheets, which are recorded instead.
Archived copies
Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Certificate Safety UL 458 - MultiPlus-II 12/24/48V 3000VA 120V
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Certificate UL 1741 and CSA C22.2 - MultiPlus-II 48V 3kVA 120V
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Declaration of Conformity - DIN 14679 - MultiPlus-II, Orion, BSC IP22/IP65/IP67
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Certificate Safety RETIE 40117 - All MultiPlus(-II) and Quattro(-II) 120V (Colombia)
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Victron Energy price list 2026-Q3 (EUR C, web edition)
Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Location: Victron Energy Limited Warranty Policy, Warranty section
Documented
Coverage conditions
Void after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres
Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Location: Victron Energy Limited Warranty Policy, Warranty section
Documented
Product warranty
5 years
Unconditional, scored. Not scored: 5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends.Official warrantySources
Original end-user purchase; maximum 66 months from Victron invoice. Claim via seller/direct customer. Excludes removal, transport, reinstallation; conditions apply.
Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.
Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.
$878.90Price as of Nov 7, 2026, 1:40 PM PST, may change
Visit sellerAffiliate link. As an Amazon Associate we earn from qualifying purchases.
Evidence
Price from the Amazon Creators API for the New-condition featured offer. Price checked .
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Every scored input has a recorded source for this product.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Original end-user purchase; maximum 66 months from Victron invoice. Claim via seller/direct customer. Excludes removal, transport, reinstallation; conditions apply.
5 years unconditional (not scored: 5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends).
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
CSA C22.2 107.1-16Product / system scope unresolvedClaimedStatus unconfirmed
Victron's public API records "CSA C22.2 107.1-16" in its safety field for exact SKU PMP482305102, and a manufacturer-hosted certificate document (Certificate UL 1741 and CSA C22.2 - MultiPlus-II 48V 3kVA 120V) lists this SKU. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
EN-IEC 60335-1Product / system scope unresolvedClaimedStatus unconfirmed
Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU PMP482305102. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
EN-IEC 60335-2-29Product / system scope unresolvedClaimedStatus unconfirmed
Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU PMP482305102. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
UL 1741Product / system scope unresolvedClaimedStatus unconfirmed
Victron's public API records "UL 1741" in its safety field for exact SKU PMP482305102, and a manufacturer-hosted certificate document (Declaration of Conformity - MultiPlus-II (GX) 3kVA, 5kVA, 8kVA, 10kVA, 15kVA) lists this SKU. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
MultiPlus-II 48/3000/35-50 120V (UL)
Manufacturer SKU PMP482305102 · US market
Observed
CSA C22.2 107.1-16: claimed
Product / system scope unresolved. Victron's public API records "CSA C22.2 107.1-16" in its safety field for exact SKU PMP482305102, and a manufacturer-hosted certificate document (Certificate UL 1741 and CSA C22.2 - MultiPlus-II 48V 3kVA 120V) lists this SKU. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU PMP482305102. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU PMP482305102. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product / system scope unresolved. Victron's public API records "UL 1741" in its safety field for exact SKU PMP482305102, and a manufacturer-hosted certificate document (Declaration of Conformity - MultiPlus-II (GX) 3kVA, 5kVA, 8kVA, 10kVA, 15kVA) lists this SKU. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.