Printed as "PEAK POWER (SURGE CAPACITY)** 15360W for ≈10s" with the footnote "**With battery only." in the EG4 12000XP spec sheet v1.2.6, captured on September 25, 2026. The row is printed once for both model numbers the sheet covers.
Printed as "PEAK POWER (SURGE CAPACITY)** 15360W for ≈10s" with the footnote "**With battery only." in the EG4 12000XP spec sheet v1.2.6, captured on September 25, 2026. The row is printed once for both model numbers the sheet covers.
Printed as "MAXIMUM EFFICIENCY (PV TO LOADS) 93.5%" in the EG4 12000XP spec sheet v1.2.6, captured on September 25, 2026. The same block prints MPPT 99%, PV to battery 92.8%, AC to battery 92.5% and battery to loads 90.2%. Printed once for both model numbers the sheet covers. Manufacturer rating; no test conditions are given.
Printed as "AC OUTPUT DATA OUTPUT VOLTAGE 120/240VAC; 208VAC" in the EG4 12000XP Off-Grid Inverter user manual (v1.2.2) (PDF page 8). The manual cover lists "MODEL #: IV-12000-XP-IN-01 IV-15000-XP-IN-01" (PDF page 1); the specification table prints one value for both.
Printed as "NOMINAL AC VOLTAGE (GRID | GENERATOR) 120/240VAC; 120/208VAC (L1/L2/N required)" in the EG4 12000XP Off-Grid Inverter user manual (v1.2.2) (PDF page 8). The manual cover lists "MODEL #: IV-12000-XP-IN-01 IV-15000-XP-IN-01" (PDF page 1); the specification table prints one value for both.
Printed as "MAX. CONTINUOUS WATTAGE 12000W (L1-L2) | 6000W (L1-N or L2-N)" in the EG4 12000XP Off-Grid Inverter user manual (v1.2.2) (PDF page 8). The same row prints 12000W for L1-L2. The manual cover lists "MODEL #: IV-12000-XP-IN-01 IV-15000-XP-IN-01" (PDF page 1); the specification table prints one value for both.
Not printed for this model in the documents on file. Revised on 1 October 2026: The manual and datasheet print 2 MPPTs with "INPUTS PER MPPT 2/2" but no total number of PV inputs.
Printed as "MAX. RECOMMENDED SOLAR INPUT 28000W (14000 per MPPT)" in EG4 12000XP manual v1.2.2, EG4 12000XP manual v1.2.2 (MODEL #: IV-12000-XP-IN-01 IV-15000-XP-IN-01), technical specifications, MAX. RECOMMENDED SOLAR INPUT row. Revised on 1 October 2026: The 12000XP manual, which covers both IV-12000-XP-IN-01 and IV-15000-XP-IN-01, prints a maximum recommended solar input of 28000 W and ranks above the datasheet; 28 kW is the same figure in kilowatts.
Printed as "MAX. UTILIZED SOLAR POWER 24000W (12000 per MPPT)" in the EG4 12000XP Off-Grid Inverter user manual (v1.2.2) (PDF page 8). Printed in watts, 12000 per MPPT. The manual cover lists "MODEL #: IV-12000-XP-IN-01 IV-15000-XP-IN-01" (PDF page 1); the specification table prints one value for both.
24,000 W
The value as the manual prints it, in W. Printed as "MAX. UTILIZED SOLAR POWER 24000W (12000 per MPPT)" in the EG4 12000XP Off-Grid Inverter user manual (v1.2.2) (PDF page 8). Printed in watts, 12000 per MPPT. The manual cover lists "MODEL #: IV-12000-XP-IN-01 IV-15000-XP-IN-01" (PDF page 1); the specification table prints one value for both.
Printed as "MIN. PV DISCONNECT/ISOLATOR SPEC TORQUE SPECS" and "600V/40A 10.6 in-lbs. (1.2Nm)" in the EG4 12000XP Off-Grid Inverter user manual (v1.2.2) (PDF page 30). The manual cover lists "MODEL #: IV-12000-XP-IN-01 IV-15000-XP-IN-01" (PDF page 1); the specification table prints one value for both.
Printed as "RECOMMENDED GENERATOR CAPACITY 6000W – 15000W" in the EG4 12000XP Off-Grid Inverter user manual (v1.2.2) (PDF page 8). The same table prints "GENERATOR MAX. CONTINUOUS CURRENT 62.5A @ 240VAC". The manual cover lists "MODEL #: IV-12000-XP-IN-01 IV-15000-XP-IN-01" (PDF page 1); the specification table prints one value for both.
Printed as "INTEGRATED BREAKER MAXIMUM AMPERAGE BATTERY CAPACITY CABLE SIZE" and "MAX. TORQUE VALUES 300A 250A 400Ah 2/0 AWG (x2)" in the EG4 12000XP Off-Grid Inverter user manual (v1.2.2) (PDF page 32). The manual also says to "install a separate DC over-current protector or disconnect device between battery and inverter". The manual cover lists "MODEL #: IV-12000-XP-IN-01 IV-15000-XP-IN-01" (PDF page 1); the specification table prints one value for both.
Printed as "MIN. PV DISCONNECT/ISOLATOR SPEC TORQUE SPECS" and "600V/40A 10.6 in-lbs. (1.2Nm)" in the EG4 12000XP Off-Grid Inverter user manual (v1.2.2) (PDF page 30). Printed with "(1.2Nm)" beside it. The manual cover lists "MODEL #: IV-12000-XP-IN-01 IV-15000-XP-IN-01" (PDF page 1); the specification table prints one value for both.
Printed as "Install the inverter upright on a vertical surface" in the EG4 12000XP Off-Grid Inverter user manual (v1.2.2) (PDF page 26). The manual cover lists "MODEL #: IV-12000-XP-IN-01 IV-15000-XP-IN-01" (PDF page 1); the specification table prints one value for both.
UL 1741Manufacturer claim · equipment listingClaimedStatus unconfirmed
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
EG4 12000XP model-specific datasheet
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
So, when I commissioned this first 12000XPv2, I was expecting to be able to force it to fail over to the grid, but I couldn't. I turned on absolutely everything we had, across 6 structures. To the point where we were pulling in 14,000 watts of solar, and over 12,000 watts from the batteries (over 55amps per AC leg on output) and it held that for 10 minutes, when I finally said, "that's enough." I remember telling my wife on the other end of the line, who was turning all the appliances and lights on, "man, this thing is impressive." It's only failed over to the grid when we've hit our battery reserve of 20%. It's paired with two EG4 314Ah indoor wall-mount batteries, and it punches way above its weight class. I'm assuming part of that is the fact I used only the very best wire I could find, and oversized every wire in the entire circuit. Bottom line, I'm getting another one. I have absolutely zero desire to export to the grid, because the utilities are awful.
The one downside is if you're using only one 12000XP to power your house or property, and you've got some distance in your feed lines (hundreds of feet), you will absolutely notice some light flickering at certain times of the day. Like when it's heavily charging the batteries with 150+ ams, and you've got an additional load on the circuit (say 8000 watts or more), voltages will drop, as happens in high-frequency inverters, and you'll see flickering at those moments. During normal operations, you shouldn't see it at all. But, a second (in parallel) 12000XP should permanently solve that.
My only desired improvements are a 3rd (totally separate MPPT). I don't mind the 2 (in parallel) MPPTs = 4, but it desperately needs a 3rd independent MPPT. And, it needs a true 200Amp bypass, not like the fake 200A (really a 125A) bypass of the Watt Cycle 12000 Super. If it had those two improvements, and they could keep the cost down around where it is now ($1900), and it's still being built in Corinth, Texas, then it would remain king for quite some time to come. I know Watt Cycle did a decent job of copying it with the Super, but that's all it is: a copy.
Disclosure: I paid for this product with my own money.
Seller review · Seller
5/5
Delivery
5/5
Delivery: On time
Signature Solar has been fantastic in their support before, during, and after the sale. They've helped me several times with just technical questions, or if I was preparing to do something a little outside the box. I've had so few issues with the system, I haven't had to really call them in a panic because of a system-down situation. Mostly just, "Hey, I'm thinking about doing this in this way, what are your thoughts on the best way to accomplish this?" I did have to RMA one of my batteries, and they took care of that immediately.
Wow, I can't believe it has almost been 2 years since I got this inverter. Overall it is great, and I would recommend it to family, friends, or anyone else. I bought it at $2,500 and thought the price was good, but now it is for sale at $1,900 and it seems like it is going to stay at that price.
Nothing in life is perfect, and there are small things to note about this inverter. Since there is a version 2 out, which only has some mild changes, some things may be worth knowing for either version.
-Wifi Dongle: This might be updated/fixed now, but it still comes up online and I have had many hours trying to get mine working properly. The dongle really is the worst part. The app software is a bit rough around the edges too for setup, because the dongle it's self works fine when setup. It really seems to want a 2.4Ghz network.
Also the dongle only sends updates every 10 seconds or so. This isn't a killer, because no sane person really should be watching it all day, but it would be nice if it was closer to 1 or 2 seconds.
-Firmware Updates: The first firmware it was shipped with had some bugs in it. To be fair, it was a brand new product, and I knew I was early adopting. But the specs were everything I wanted and a price I liked at the time. The PV MPPT was not working properly in the morning, and I would have to disconnect and reconnect the PV(breaker or disconnect switch) each morning. They sent a beta update to me within days of me calling. The EG4 and Signature Solar customer service has always been great, even if some aren't as skilled at SS.
The next public updates have been fine up to 0507,
then 0709 came out with new features I wasn't ever expecting to see! But it messed up the charging and would not keep the batteries at my specified voltage after reaching it. The battery would then go down to resting voltage, so essentially, the battery cells would not properly be able to balance well. So I called, and SS could not revert, and they had me call EG4, and they did the process for me. It was fairly quick for me, after figuring things out with both companies(that it wasn't my fault).
So there is a new firmware updated expected to be released in the near future(it has been many months of waiting though), and hopefully that fixes my issue. If not, I can just roll back to 0507 and everything works just fine. Note that I do run in Lead-Acid mode/Voltage, not SOC mode. This is to give my batteries the best chance of properly balancing, and I also didn't like when the batteries were controlling my inverter. Now it is more of a 2 step safety this way too.
Install was as expected. It will only be easier or harder depending on each person's situation, but it requires 2 people to safely lift it into place, or another alternative method. It is heavy and big.
UPS(uninterrupted power supply) works well, even if you are on grid power usage, or charging on too, if it drops out, you may get a tiny light flicker but nothing shuts down in the house, or annoying time clock fixes.
Loads:
In Florida, it "can" run a normal sized single family house, with limitations. 2 would be ideal in parallel. That said, I have reduced my water heater element to 2500watt, instead of 4500, put a soft start on my air conditioner(needed for voltage drop on startup), and I do try not to overload it. So when doing laundry I can draw 7KW from just that, then the A/C to 10,000 and regular loads of house run around 1KW-2KW. Which brings me right to the edge. So turning on a microwave at the wrong time can push it over to grid power. But it really isn't a big deal, just hurts the soul a little each time(haha). After a few minutes back in normal usage, it goes right back to battery/solar. A 2nd one would fix this, so it is not the unit's fault, just something to keep in mind for anyone looking to buy. Also SS says you can mix a V1 and V2 together, which is good for anyone in my situation, as I may end up doing that some day.
I really don't have much to complain about this product, and these days where it seems disappointment is too often there, I thought to myself a few days ago, I am really happy with it overall and glad I got it. It still has 3 years of warranty, and I ideally want it to last 10+ years. Preferably longer, but I know inverters don't typically last forever. I guess one thing is the fans get a bit loud at higher current. When you start getting around 10KW or more for charge or discharge, they get pretty loud. Its not terrible, and they vary with the load. Way better than some other options out there. So I wouldn't keep this thing in an office or inside anywhere close by.
Current Recommendation:
Buy it, and enjoy it!
Seller review · Seller
5/5
Delivery
4/5
Delivery: On time
Signature Solar has always tried to be helpful. Some people there now(now they are a bigger company), are not quite as knowable, but they do try, and ask others for help with unfamiliar issues. Some are still top notch too.
I have never had a problem with SS, and I have worked with them through 10-20 phone calls. Not all for this inverter. They have a huge support team. I know some people have not had a good experience, probably not many people, but that is not my experience with them. Everything was as expected.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Every scored input has a recorded source for this product.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
CertificatesUL 1741Claimed10.2 / 45.0
Manufacturer claim; issuer verification pending. Applies to the exact inverter.
70 against 1 W, the lowest documented for an inverter in the 7 to 15 kW output band (printed by the maker): Fronius Primo 11.4-1 208-240. The bar is a printed bound: less than 1 W, as printed.
Less than 70 W in standby, tested with constant 300 VDC PV. This is a stated upper limit, not a measured average. Datasheet page 3. Printed as a bound: less than 70 W, as printed.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
UL 1741Product / system scope unresolvedClaimedStatus unconfirmed
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
UL 1741Manufacturer claim · equipment listingClaimedStatus unconfirmed
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
IV-12000-XP-IN-01
Manufacturer SKU IV-12000-XP-IN-01 · US market · 1 other version recorded
Observed
UL 1741: claimed
Product / system scope unresolved. Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Links to DIY Solar Forum threads. The title is the forum's own words. It is a member's experience, not a Charged test, not a verified fault rate, and not a statement by the maker.