SunGoldPower SPH10048P

By SunGoldPowerSKU SPH10048PGTIN 747783675352

from$1,580
Price unchanged · 34 checks since Sep 20

Paid link · price checked

Key specs

Units
SKU
SPH10048P
Official store listingPaid link.
Sources

SunGoldPower's own product data, captured 2026-10-27, prints SKU "SPH10048P" for option "Only Inverter [Brand New]" (variant 42879882592393) of listing "10KW 48V Split Phase Solar Inverter".

Official store listing: SunGoldPower store Paid link.Checked · Earlier document

Location: SunGoldPower product data (products.json, page 1), listing "10KW 48V Split Phase Solar Inverter" (handle 10kw-48v-split-phase-solar-inverter), option "Only Inverter [Brand New]", "sku":"SPH10048P"

Documented

UPC / EAN / GTIN
747783675352
Distributor product pagePaid link.
Sources

ShopSolar's product data prints barcode 747783675352 for its variant "Default Title" (SKU SPH10048P), the exact variant this record's ShopSolar offer links; the SKU equals the record's manufacturer SKU. A seller statement; package, bundle and regional variants carry their own codes, and no code is carried to another variant.

Distributor product page: ShopSolar store product data for sungold-power-10kw-48v-split-phase-solar-inverter (captured October 12, 2026) Paid link.Checked · Earlier document

Location: Store product data, variant 46451720028300, barcode

Documented

Cooling
Intelligent fan
Official instruction manual
Sources

Exact wording, one value for both models.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, General, Cooling mode row

Documented

Noise db
60 dB
<60 dB as printedOfficial instruction manual
Sources

Printed as "<60 dB" (an upper bound; the table says dB and gives no weighting or distance), one value for both models.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, General, Noise row

Documented

Grounding (manual)
Please ensure that the grounding terminal is reliably connected to the grounding busbar.
Official instruction manual
Sources

Printed as "Please ensure that the grounding terminal is reliably connected to the grounding busbar." (PDF page 17) and, for setting item 63 "Auto N-PE connection switch function", "DIS (default) Disable auto N-PE connection switch" (PDF page 46) in the SPH8-10KW "All-in-one solar charge inverter" user manual Version V1.3 (models SPH8048P and SPH10048P), once for both models.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: PDF page 17, section 4.7 Grounding, and PDF page 46, setting item 63, SPH10048P

Documented

Weight
27 kg60 lb converted
Official instruction manual
Sources

Printed as "27 kg", one value for both models.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, General, Weight row

Documented

MPPT trackers
2
Official instruction manual
Sources

Printed once for both models.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, PV Input, No. of MPPT Trackers row

Documented

Peak output
20,000 W
Official instruction manual
Sources

Printed as "Max. Peak Power 16,000 W 20,000 W" under the columns SPH8048P and SPH10048P in the SPH8-10KW user manual V1.3; 20,000 W is the SPH10048P column. No duration is printed. Captured on September 25, 2026.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3, section 9 Parameter Table, "Max. Peak Power" row, SPH10048P column

Documented

AC voltage
120/240 VAC (single-phase/split-phase)
Official instruction manual
Sources

Exact wording, printed once for both models (merged cell); the table marks the value as settable.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Inverter output, Rated Output Voltage row

Documented

All specs48
Peak output
20,000 W
Official instruction manual
Sources

Printed as "Max. Peak Power 16,000 W 20,000 W" under the columns SPH8048P and SPH10048P in the SPH8-10KW user manual V1.3; 20,000 W is the SPH10048P column. No duration is printed. Captured on September 25, 2026.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3, section 9 Parameter Table, "Max. Peak Power" row, SPH10048P column

Documented

AC voltage
120/240 VAC (single-phase/split-phase)
Official instruction manual
Sources

Exact wording, printed once for both models (merged cell); the table marks the value as settable.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Inverter output, Rated Output Voltage row

Documented

Battery charging
200 A
Official instruction manual
Sources

Printed as "200 A" (Max. Hybrid Charging Current) in the SPH10048P column; settable.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Battery, Max. Hybrid Charging Current row, SPH10048P column

Documented

Efficiency
92 %
Battery inverterOfficial instruction manual
Sources

Printed once for both columns as "Max. Efficiency of Battery 92%" in the SPH8-10KW user manual V1.3, captured on September 25, 2026, beside "MPPT Tracking Efficiency 99.9%". Manufacturer rating; no test conditions are given.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3, section 9 Parameter Table, Efficiency, "Max. Efficiency of Battery" row

Documented

AC frequency
50/60 Hz
Official instruction manual
Sources

Printed as "50/60 Hz", one value for both models; the table marks it as settable.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Inverter output, Rated Frequency row

Documented

Grid charge current
120 A
Official instruction manual
Sources

Printed as "120 A" in the SPH10048P column; settable.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Battery, Max. Grid/Generator Charge Current row, SPH10048P column

Documented

Output waveform
Pure sine wave
Official instruction manual
Sources

Printed once for both models.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Inverter output, Output Wave row

Documented

AC output
Split-phase mode (default); Single-phase mode
Official instruction manual
Sources

Printed as "Split-phase mode (default)" and "Single-phase mode" in section 4.1 Wiring mode (depends on the output mode) of SunGoldPower's SPH8-10KW user manual (Version V1.3) (PDF page 10); the value lists the two modes in the printed order. Under the split-phase mode the same page prints, for the SPH series, "AC output phase voltage (L-N) 100 VAC−120 VAC, 120 VAC (default)" and "AC output line voltage (L-L) 200 VAC−240 VAC, 240 VAC (default)". The manual's parameter table (PDF page 61) is headed "SPH8048P SPH10048P". Corrected on November 3, 2026: the catalog had published 120/240 V split phase (L-N 120 V, L-L 240 V), default; single-phase 120 V mode selectable, cited to SunGoldPower (cdn.shopify.com). The earlier text was a rewording, not the printed words; the value is restored to the words the manual prints, and the earlier text is kept here. Earlier note: "Printed as "AC output phase voltage (L-N) 100 VAC−120 VAC, 120 VAC (default) AC output line voltage (L-L) 200 VAC−240 VAC, 240 VAC (default)"; "Rated Output Voltage 120/240 VAC (single-phase/split-phase)" in SPH8-10KW_User_Manual_V1.3_20250909.pdf (PDF page 10; PDF page 61). Revised on 16 October 2026: Owner report 2026-10-16 (inverter filter AC output 120/240 V): the earlier text omitted the voltages the manual prints, so the unit fell out of the 120/240 V filter although one unit gives 120 V line to neutral and 240 V line to line."

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: PDF page 10, 4.1 Wiring mode (depends on the output mode), SPH10048P

Documented

Transfer time
10 ms
Official instruction manual
Sources

Printed as "10 ms (typical value)", one value for both models.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Inverter output, Switching Time row

Documented

Battery voltage
48 V
Official instruction manual
Sources

Printed as "48 Vdc", one value for both models.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Battery, Rated Battery Voltage row

Documented

Surge AC output
20,000 W
Official instruction manual
Sources

Printed as "20,000 W" (Max. Peak Power) in the SPH10048P column. The table gives no duration for the peak.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Inverter output, Max. Peak Power row, SPH10048P column

Documented

AC input voltage
90 VAC−140 VAC
Official instruction manual
Sources

Exact wording, printed once for both models.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Mains/generator input, Input Voltage Range row

Documented

Grid pass-through
63 A
Official instruction manual
Sources

Printed as "Bypass Overload Current 63 A", one value for both models.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Mains/generator input, Bypass Overload Current row

Documented

AC output voltage
AC output phase voltage (L-N) 100 VAC−120 VAC, 120 VAC (default); AC output line voltage (L-L) 200 VAC−240 VAC, 240 VAC (default)
Official instruction manual
Sources

Printed as "AC output phase voltage (L-N) 100 VAC−120 VAC, 120 VAC (default)" and "AC output line voltage (L-L) 200 VAC−240 VAC, 240 VAC (default)" in the split-phase mode table of section 4.1 Wiring mode (depends on the output mode) of SunGoldPower's SPH8-10KW user manual (Version V1.3) (PDF page 10), applicable model "SPH series"; the value lists the two printed lines in order. The single-phase mode table on the same page prints the phase voltage (L-N) line only.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: PDF page 10, 4.1 Wiring mode (depends on the output mode), split-phase mode table

Documented

Continuous output
10 kW
Official instruction manual
Sources

Printed as "10,000 W" in the SPH10048P column (columns: SPH8048P then SPH10048P). Rated output power at the rated output voltage of 120/240 VAC.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Inverter output, Rated Output Power row, SPH10048P column

Documented

Compatible batteries / BMS
Lithium-ion battery/lead-acid battery/user-defined battery
Official instruction manual
Sources

Printed as "Battery Type Lithium-ion battery/lead-acid battery/user-defined battery" (marked settable), one value for both models (merged cell), in the SPH8-10KW "All-in-one solar charge inverter" user manual Version V1.3 (models SPH8048P and SPH10048P).

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: PDF page 61, section 9 Parameter Table, Battery, Battery Type row, SPH10048P column

Documented

Battery conversion efficiency
92 %
Official instruction manual
Sources

Printed with the label "Max. Efficiency of Battery" as "92%", one value for both models. The label does not say whether this is battery inverter efficiency.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Efficiency, Max. Efficiency of Battery row

Documented

Battery operating voltage
40 to 60 V
Official instruction manual
Sources

Printed as "40 Vdc−60 Vdc", one value for both models; the table marks it as settable.

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Location: User manual V1.3 (SPH8-10KW_User_Manual_V1.3_20250909.pdf), section 9 Parameter Table, Battery, Voltage Range row

Documented

Published claims and calculations, not independent test results.

Documents

2 on file
  • PDF
    SPH8-10KW_User_Manual_V1.3_20250909.pdfOfficialSunGoldPowerOfficial instruction manual
    Certificate & compliance claims (7)
    IEC62109-1Manufacturer claim · equipment listingClaimedListed when checked

    SunGoldPower's own statement, recorded exactly as printed: "Safety IEC62109-1, IEC62109-2, and UL1741" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

    Manufacturer document

    Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
    IEC62109-2Manufacturer claim · equipment listingClaimedListed when checked

    SunGoldPower's own statement, recorded exactly as printed: "Safety IEC62109-1, IEC62109-2, and UL1741" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

    Manufacturer document

    Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
    UL1741Manufacturer claim · equipment listingClaimedListed when checked

    SunGoldPower's own statement, recorded exactly as printed: "Safety IEC62109-1, IEC62109-2, and UL1741" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

    Manufacturer document

    Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
    EN61000-6-1Manufacturer claim · equipment listingClaimedListed when checked

    SunGoldPower's own statement, recorded exactly as printed: "EMC EN61000-6-1, EN61000-6-3, and FCC 15 class B" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

    Manufacturer document

    Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
    EN61000-6-3Manufacturer claim · equipment listingClaimedListed when checked

    SunGoldPower's own statement, recorded exactly as printed: "EMC EN61000-6-1, EN61000-6-3, and FCC 15 class B" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

    Manufacturer document

    Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
    FCC 15 class BManufacturer claim · equipment listingClaimedListed when checked

    SunGoldPower's own statement, recorded exactly as printed: "EMC EN61000-6-1, EN61000-6-3, and FCC 15 class B" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

    Manufacturer document

    Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
    RoHSManufacturer claim · equipment listingClaimedListed when checked

    SunGoldPower's own statement, recorded exactly as printed: "RoHS Yes" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

    Manufacturer document

    Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Linked from https://sungoldpower.com/products/10kw-48v-split-phase-solar-inverter with link text "none".

    Location: SPH8-10KW_User_Manual_V1.3_20250909.pdf

    Retrieved

    Original manufacturer-hosted PDF preserved byte for byte, linked from the manufacturer's own product page for SKU SPH10048P. The revision is whatever was published at this URL on the access date; no later revision was checked and no separate variant coverage is claimed beyond the page that linked it.

    SHA-256: 83ecface82769a3724b759cea0b30afafc0d4c00d5ab0ef851594882475dcd89

    Archived copies

    Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 6.91 MB

    Archived copy, unaltered, kept as a record of what SunGoldPower published. Original address: https://cdn.shopify.com/s/files/1/0323/4090/2025/files/SPH8-10KW_User_Manual_V1.3_20250909.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 83ecface82769a3724b759cea0b30afafc0d4c00d5ab0ef851594882475dcd89

    Open
  • WEB
    SunGoldPower 10KW 48V Split Phase Solar Inverter (SPH10048P) product page (captured October 20, 2026)OfficialSunGoldPowerOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-20.

    Location: Product highlights

    Retrieved

    SunGoldPower's own product page for SPH10048P, captured October 20, 2026 with the paced research fetcher to read the market it states. Manufacturer statements, not independent tests.

    OpenPaid link.

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • WEB
    10KW 48V Split Phase Solar Inverter, SunGoldPower product page (September 23, 2026 capture)OfficialSunGoldPowerOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Product heading; Highlight list; Specification and User Manual tabs (manual-download-button links)

    Retrieved

    SunGoldPower's own product page, captured byte for byte on September 23, 2026. It establishes what SunGoldPower published for SPH10048P on that date: the page heading, the Highlight text, the variant selector (SKUs SPH10048P, SPH10048P+2*SG48100P, SPH10048P+2*SG48200T) and the 2 document link(s) under its User Manual tab. Prices and stock on the page are the state of a promotional storefront and are not recorded from it. A specification quoted from the page is SunGoldPower's own published figure, not a test result.

    OpenPaid link.

Archived documents

SPH8-10KW_User_Manual_V1.3_20250909.pdf

Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 6.91 MB

Archived copy, unaltered, kept as a record of what SunGoldPower published. Original address: https://cdn.shopify.com/s/files/1/0323/4090/2025/files/SPH8-10KW_User_Manual_V1.3_20250909.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 83ecface82769a3724b759cea0b30afafc0d4c00d5ab0ef851594882475dcd89

SPH8048P_10048P_UL1741_certificate_of_compliance.pdf

Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.59 MB

Archived copy, unaltered, kept as a record of what SunGoldPower published. Original address: https://cdn.shopify.com/s/files/1/0323/4090/2025/files/SPH8048P_10048P_UL1741_certificate_of_compliance.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 8320902c204a5dd6e3eb28bfa0155d12d00e62142f2f08f5df4e8124e4becd03

Submit a document

Warranty

No warranty terms on file.

Sellers

Affiliate links below. Affiliate disclosure

Report a seller problem

Price history

Prices we read at ShopSolar and SunGoldPower · 35 readings from to

Chart, listings & data

Since · Listing price (USD)

View listing at ShopSolar Paid link.
View listing at SunGoldPower Paid link.
$1,500$1,600$1,700ShopSolar: $1,580 · Sep 20, 2026, 7:50 AM PDTShopSolar: $1,580 · Sep 24, 2026, 2:04 AM PDTShopSolar: $1,580 · Sep 25, 2026, 3:02 AM PDTShopSolar: $1,580 · Sep 28, 2026, 2:02 AM PDTShopSolar: $1,580 · Sep 30, 2026, 1:05 AM PDTShopSolar: $1,580 · Oct 1, 2026, 3:32 AM PDTShopSolar: $1,580 · Oct 2, 2026, 3:31 AM PDTShopSolar: $1,580 · Oct 4, 2026, 1:06 AM PDTShopSolar: $1,580 · Oct 5, 2026, 1:05 AM PDTShopSolar: $1,580 · Oct 6, 2026, 1:05 AM PDTShopSolar: $1,580 · Oct 8, 2026, 1:06 AM PDTShopSolar: $1,580 · Oct 11, 2026, 2:00 AM PDTShopSolar: $1,580 · Oct 13, 2026, 1:15 AM PDTShopSolar: $1,580 · Oct 15, 2026, 1:06 AM PDTShopSolar: $1,580 · Oct 16, 2026, 1:06 AM PDTShopSolar: $1,580 · Oct 18, 2026, 1:06 AM PDTShopSolar: $1,580 · Oct 22, 2026, 1:16 AM PDTShopSolar: $1,580 · Oct 23, 2026, 3:10 AM PDTShopSolar: $1,580 · Oct 24, 2026, 1:06 AM PDTShopSolar: $1,580 · Oct 25, 2026, 1:06 AM PDTShopSolar: $1,580 · Oct 26, 2026, 1:07 AM PDTShopSolar: $1,580 · Oct 27, 2026, 1:07 AM PDTShopSolar: $1,580 · Oct 28, 2026, 1:26 AM PDTShopSolar: $1,580 · Oct 29, 2026, 1:16 AM PDTShopSolar: $1,580 · Oct 30, 2026, 1:26 AM PDTShopSolar: $1,580 · Oct 31, 2026, 1:27 AM PDTShopSolar: $1,580 · Nov 3, 2026, 1:06 AM PSTShopSolar: $1,580 · Nov 4, 2026, 3:31 AM PSTShopSolar: $1,580 · Nov 5, 2026, 1:06 AM PSTShopSolar: $1,580 · Nov 6, 2026, 1:07 AM PSTShopSolar: $1,580 · Nov 7, 2026, 1:17 AM PSTShopSolar: $1,580 · Nov 9, 2026, 3:32 AM PSTShopSolar: $1,580 · Nov 12, 2026, 1:26 AM PSTSunGoldPower: $1,580 · Oct 31, 2026, 2:37 PM PDTSep 20, 2026Nov 12, 2026
ShopSolar$1,580Nov 12, 2026, 1:26 AM PSTLatest check · hover or tap for earlier prices

A break in a line is a gap in our readings: no price is drawn for days we did not read.

Price data
Collected price observations by seller
Checked (UTC)SellerPrice
Sep 20, 2026, 7:50 AM PDTShopSolar Paid link.$1,580
Sep 24, 2026, 2:04 AM PDTShopSolar Paid link.$1,580
Sep 25, 2026, 3:02 AM PDTShopSolar Paid link.$1,580
Sep 28, 2026, 2:02 AM PDTShopSolar Paid link.$1,580
Sep 30, 2026, 1:05 AM PDTShopSolar Paid link.$1,580
Oct 1, 2026, 3:32 AM PDTShopSolar Paid link.$1,580
Oct 2, 2026, 3:31 AM PDTShopSolar Paid link.$1,580
Oct 4, 2026, 1:06 AM PDTShopSolar Paid link.$1,580
Oct 4, 2026, 9:30 AM PDTShopSolar Paid link.$1,580
Oct 5, 2026, 1:05 AM PDTShopSolar Paid link.$1,580
Oct 6, 2026, 1:05 AM PDTShopSolar Paid link.$1,580
Oct 8, 2026, 1:06 AM PDTShopSolar Paid link.$1,580
Oct 11, 2026, 2:00 AM PDTShopSolar Paid link.$1,580
Oct 13, 2026, 1:15 AM PDTShopSolar Paid link.$1,580
Oct 15, 2026, 1:06 AM PDTShopSolar Paid link.$1,580
Oct 16, 2026, 1:06 AM PDTShopSolar Paid link.$1,580
Oct 18, 2026, 1:06 AM PDTShopSolar Paid link.$1,580
Oct 22, 2026, 1:16 AM PDTShopSolar Paid link.$1,580
Oct 23, 2026, 3:10 AM PDTShopSolar Paid link.$1,580
Oct 24, 2026, 1:06 AM PDTShopSolar Paid link.$1,580
Oct 25, 2026, 1:06 AM PDTShopSolar Paid link.$1,580
Oct 26, 2026, 1:07 AM PDTShopSolar Paid link.$1,580
Oct 27, 2026, 1:07 AM PDTShopSolar Paid link.$1,580
Oct 28, 2026, 1:26 AM PDTShopSolar Paid link.$1,580
Oct 29, 2026, 1:16 AM PDTShopSolar Paid link.$1,580
Oct 30, 2026, 1:26 AM PDTShopSolar Paid link.$1,580
Oct 31, 2026, 1:27 AM PDTShopSolar Paid link.$1,580
Oct 31, 2026, 2:37 PM PDTSunGoldPower Paid link.$1,580
Nov 3, 2026, 1:06 AM PSTShopSolar Paid link.$1,580
Nov 4, 2026, 3:31 AM PSTShopSolar Paid link.$1,580
Nov 5, 2026, 1:06 AM PSTShopSolar Paid link.$1,580
Nov 6, 2026, 1:07 AM PSTShopSolar Paid link.$1,580
Nov 7, 2026, 1:17 AM PSTShopSolar Paid link.$1,580
Nov 9, 2026, 3:32 AM PSTShopSolar Paid link.$1,580
Nov 12, 2026, 1:26 AM PSTShopSolar Paid link.$1,580

Owner reviews

4.5 / 53 reviews

Recent reviews count from the latest approved revision. Verified reviews carry 19× the weight. Select a period to filter.

Ratings by category

Warranty
Not rated
Software
4.0 / 53 reviews
Reliability
4.5 / 53 reviews
Build quality
4.5 / 53 reviews
Ease of install
5.0 / 53 reviews
Customer service
5.0 / 51 review

Showing 3 of 3 reviews

@hope4bruce2 pointsVerified ownerPublished , updated

Great Purchase

Software
5/5
Reliability
5/5
Build quality
5/5
Ease of install
5/5
Customer service
5/5

product has worked excellent. I've been charging my electric vehicle and running a mini split in the garage off it for several months now. Without incident. Update: I added 220v grid/generator input to power the onboard 120 amp 48v charger. Awsome charge capacity. I have 5.4kw of solar but having massive additional charge abilities only increases the value of my 16kw of batteries. AC charge works great from grid. Will test from generator and update soon

Original & previous versions

@hope4bruceVerified owner

Great Purchase

Software
5/5
Reliability
5/5
Build quality
5/5
Ease of install
5/5

product has worked excellent. i've been charging my electric vehicle and running a mini split in the garage off it for several months now. Without incident.

@hope4bruceVerified owner

Great Purchase

Software
5/5
Reliability
5/5
Build quality
5/5
Ease of install
5/5

product has worked excellent. i've been charging my electric vehicle and running a mini split in the garage off it for several months now. Without incident.

@peterevans0 pointsUnverified

Have three in parallel.

Software
4/5
Reliability
4/5
Build quality
5/5
Ease of install
5/5

All three working at 6000 watts max pv input and output each, for 1.5 years. No issues. These are the words to reach the 25 words required to describe a perfectly working product.

@toopriddy1 pointVerified owner

Nice budget all in one solar+inverter

Software
3/5
Reliability
4/5
Build quality
4/5
Ease of install
5/5

I have two of these in parallel split phase. Generator input is connected to utilities and setup for charging when batteries get to 10%. Provides power for 5ton HVAC and pool pump/vaccume. I have operated a car lift while HVAC, pool, stove and range were all operating. Had to install soft start on the HVAC compressor as even with 2 of these inverters they could not handle the HVAC by itself. iphone app works well and has good today/past information display. I wish that it would have a cost calculator but maybe I only care about this in the first year of usage. Was able to use homebridge and AI to build something that logged into the website and pulled data to have automation based on the data I have access to. Build Quality: The product is solid and paint and fitment is good. The choice of an oval knockouts for the access to have conduit go to the electrical/solar is an odd one as there are no oval conduits. The spacing from conduit to the terminal does not allow for easy install. The conduit hole size is small given that 6AWG wires have to go into it. The terminal connectors however are another story. I received one of these from amazon which had a stripped terminal, it would never screw down at all (I didnt manhandle it) and amazon replaced it, sending someone to pick up the package. After moving these two I have to another location another terminal screw stripped (using a torque screwdriver to ensure I didnt over torque) Reliability: I have not had to in normal service do anything to these other than vacuum the dust filters. There is however a problem stated below related to odd-situation usage. Ease of Install Just like everything else it is heavy. The top mounting screws allow you to mount it on the wall easy after getting screws aligned. It would have been useful to have a paper template in the box for drawing out the holes on the wall. It is weird/odd that the hole pattern on top does not match on bottom, basically ensuring that only 1 of the screws could go into a stud. Would be interesting to see the hole pattern be 16" on center. Problems: 1. if you have the ability to switch to utility power (I have a transfer switch) and there is no load on the inverters in parallel, one will get a bit angry and stop and start charging from solar complaining that they dont really sense the load properly. If you apply a load 50% of the time it will still refuse to charge from solar, you have to restart the unit. I have never seen this happen when always having a load connected. 2. with utility connected to the generator port it will always pull idle power from utility instead of battery when the solar is not generating power. I would like the generator/utilities to never pull power unless I have set for it to pull power from utilities. Looking to hook up a contactor to the dry contacts to turn on and off power to the generator port if I dont find a solution with the manufacturer Would I buy another one of these: yes What would I buy if I had the money: victron

Owner system photo 1

Evidence score

24/100Missing details60% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Warranty term needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Warranty term, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5

How it works

Certificates

10 on fileUL 1741 · claimed
UL 1741:2021 Ed.3+R:19May2023Product / system scope unresolvedClaimedListed when checked

Intertek certificate of compliance for report 2309A1674SHA-001, issued April 10, 2026, product "Solar Charger Inverter( Stand alone inverter)", models SPH8K48SP, SPH8048P, SPH10K48SP and SPH10048P. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.

Models: SPH10048P

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official certificate: SPH8048P_10048P_UL1741_certificate_of_compliance.pdf Checked · Earlier document
CSA C22.2#107.1:2016 Ed.4+U1Product / system scope unresolvedClaimedListed when checked

Intertek certificate of compliance for report 2309A1674SHA-001, issued April 10, 2026, product "Solar Charger Inverter( Stand alone inverter)", models SPH8K48SP, SPH8048P, SPH10K48SP and SPH10048P. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.

Models: SPH10048P

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official certificate: SPH8048P_10048P_UL1741_certificate_of_compliance.pdf Checked · Earlier document
IEC62109-1Product / system scope unresolvedClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "Safety IEC62109-1, IEC62109-2, and UL1741" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Models: SPH10048P

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
IEC62109-2Product / system scope unresolvedClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "Safety IEC62109-1, IEC62109-2, and UL1741" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Models: SPH10048P

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
UL1741Product / system scope unresolvedClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "Safety IEC62109-1, IEC62109-2, and UL1741" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Models: SPH10048P

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
EN61000-6-1Product / system scope unresolvedClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "EMC EN61000-6-1, EN61000-6-3, and FCC 15 class B" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Models: SPH10048P

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
EN61000-6-3Product / system scope unresolvedClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "EMC EN61000-6-1, EN61000-6-3, and FCC 15 class B" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Models: SPH10048P

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
FCC 15 class BProduct / system scope unresolvedClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "EMC EN61000-6-1, EN61000-6-3, and FCC 15 class B" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Models: SPH10048P

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
RoHSProduct / system scope unresolvedClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "RoHS Yes" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Models: SPH10048P

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
UL 1741Product / system scope unresolvedClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "Certified UL 1741 by ETL for Off Grid Solar System" (products-10kw-48v-split-phase-solar-inverter.html). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Models: SPH10048P

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official product page: 10KW 48V Split Phase Solar Inverter, SunGoldPower product page (September 23, 2026 capture) Paid link.Checked · Earlier document
Datasheet & manual claims7
IEC62109-1Manufacturer claim · equipment listingClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "Safety IEC62109-1, IEC62109-2, and UL1741" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Manufacturer document

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
IEC62109-2Manufacturer claim · equipment listingClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "Safety IEC62109-1, IEC62109-2, and UL1741" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Manufacturer document

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
UL1741Manufacturer claim · equipment listingClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "Safety IEC62109-1, IEC62109-2, and UL1741" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Manufacturer document

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
EN61000-6-1Manufacturer claim · equipment listingClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "EMC EN61000-6-1, EN61000-6-3, and FCC 15 class B" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Manufacturer document

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
EN61000-6-3Manufacturer claim · equipment listingClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "EMC EN61000-6-1, EN61000-6-3, and FCC 15 class B" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Manufacturer document

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
FCC 15 class BManufacturer claim · equipment listingClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "EMC EN61000-6-1, EN61000-6-3, and FCC 15 class B" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Manufacturer document

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document
RoHSManufacturer claim · equipment listingClaimedListed when checked

SunGoldPower's own statement, recorded exactly as printed: "RoHS Yes" (SPH8-10KW_User_Manual_V1.3_20250909.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.

Manufacturer document

Official instruction manual: SPH8-10KW_User_Manual_V1.3_20250909.pdf Checked · Earlier document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
SPH10048P

Manufacturer SKU SPH10048P · US market

Observed

UL 1741:2021 Ed.3+R:19May2023: claimed

Product / system scope unresolved. Intertek certificate of compliance for report 2309A1674SHA-001, issued April 10, 2026, product "Solar Charger Inverter( Stand alone inverter)", models SPH8K48SP, SPH8048P, SPH10K48SP and SPH10048P. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.

Official certificate: SPH8048P_10048P_UL1741_certificate_of_compliance.pdf Checked · Earlier document
Observed

CSA C22.2#107.1:2016 Ed.4+U1: claimed

Product / system scope unresolved. Intertek certificate of compliance for report 2309A1674SHA-001, issued April 10, 2026, product "Solar Charger Inverter( Stand alone inverter)", models SPH8K48SP, SPH8048P, SPH10K48SP and SPH10048P. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.

Official certificate: SPH8048P_10048P_UL1741_certificate_of_compliance.pdf Checked · Earlier document

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.