About brandMagnum Series inverters and inverter/chargers, including the MS, MS-PAE and MSH-RV Series, are published by DMX Power, LLC on dmx-power.com, where the catalog pages mark them Made in USA. DMX Power's Limited Warranty Policy names Magnum Series Inverters and Inverter Chargers among its products and says DMX Power makes power inverters for recreational vehicle, marine, fleet, renewable energy and off-grid systems.
SKU detail
locator: Product page heading and tables; owner's manual Appendix A model header
conditions: Model number as printed by DMX Power on its MS-PAE Series page for this model and in the MS-PAE Series owner's manual.
120/240 VAC split-phase output in a single inverter
Printed as "120/240 VAC split-phase output in a single inverter" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 10).
Where: PDF page 10, 1.0 Introduction, feature list
The inverter system grounding is the responsibility of the installer in accordance with the NEC.
Printed as "The inverter system grounding is the responsibility of the installer" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 20).
Printed as "105 ADC" continuous charger output at 25 °C; the input current at rated output is 15 AAC per leg at 120/240 VAC split phase. Read from the MS4024PAE column (the first of two).
Allow at the minimum an airspace clearance of 6” (15.2 cm) at the intake and exhaust vents, and 3” (7.6 cm) everywhere else to provide adequate ventilation.
Printed as "airspace clearance of 6” (15.2 cm) at the intake and exhaust vents" and "and 3” (7.6 cm) everywhere else to provide adequate ventilation" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 17).
Where: PDF page 17, 2.1.3 Locating the Inverter, Ventilation
W 321 × H 203 × L 349 mm / W 12.6 × H 7.99 × L 13.7 in converted
Printed as "13.75” x 12.65” x 8.0” (34.9 cm x 32.1 cm x 20.3 cm)" (length x width x height) in the owner's manual; the centimeter figures are recorded in millimeters. The page prints 13.75" × 12.65" × 8".
Where: Owner's manual Appendix A, Unit Dimensions row; product page Physical table
Sources
Converted: 34.9 cm x 10 = 349 mm; 32.1 cm x 10 = 321 mm; 20.3 cm x 10 = 203 mm
Not a grid-interactive (also known as utility-interactive) inverter and does not have the capability to export (or sell) power back into the utility grid
Printed as "is not a grid-interactive (also known as utility-interactive) inverter" and "does not have the capability to export (or sell) power back into the utility grid" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 10).
Printed as "120/240 VAC split phase" in the owner's manual and "Output 120 / 240 VAC Phase Single" on the page. The transfer relay is printed as "2 legs at 30A per leg transfer standard".
Printed as "each AC HOT input to the inverter requires a 30-amp continuous duty rated" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 27). Printed as the requirement to obtain the 30-amp continuous pass-thru capability. Note 1: per NEC, if the breaker is not rated for 100% continuous duty it must be derated by 80%.
Where: PDF page 27, 2.3.2 AC Wire Size and Overcurrent Protection
Printed as "[260 amps] 250 amps4 #6 AWG (13.3 mm²)" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 23). Note 5 of the table: per the NEC, the DC grounding electrode conductor can be a #6 AWG conductor if that is the only connection to the grounding electrode and that grounding electrode is a rod, pipe, or plate electrode.
Where: PDF page 23, 2.2.2, Table 2-1, MS4024PAE row, DC Ground Electrode Wire Size column
Printed as "MS4024PAE 222 amps 278 amps #4/0 AWG (107.2 mm²) [260 amps]" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 23). The bracketed figure is the conduit rating. Table 2-2 (PDF page 24) prints "#4/0 AWG x 2 (107.2 mm²)" for 5 to 10 ft and "not recommended" for 10 to 15 ft.
Where: PDF page 23, 2.2.2, Table 2-1 Recommended DC Wire/Overcurrent Device, MS4024PAE row, Recommended DC Wire Size [conduit rating] column
It can be connected to the utility grid (or to a generator) to allow the inverter batteries to be charged, and to power inverter loads while connected
Printed as "It can be connected to the utility grid (or to a generator)" and "to allow the inverter batteries to be charged, and to power inverter loads while connected" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 10).
Printed as 5800 real watts for 5 seconds in the owner's manual and "5,800 W Peak surge" on the page. Read from the MS4024PAE column (the first of two).
Where: Owner's manual Appendix A, 5 sec surge power row; product page headline figures
Printed as "AC wiring must be no less than #10 AWG (5.3 mm2) gauge copper wire" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 27). The same statement covers AC input and output wiring.
Where: PDF page 27, 2.3.1 Pre-AC Wiring Requirements
Printed as "Torque all AC wiring connections to 16 in lbf (1.8 Nm)" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 20).
Printed as "[260 amps] 250 amps4 #6 AWG (13.3 mm²)" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 23). Note 4 of the table: the next larger standard size overcurrent device may be used if the derated cable ampacity falls between standard sizes. Section 2.2.2 says the device can be a fuse or circuit breaker and must be DC rated.
Where: PDF page 23, 2.2.2, Table 2-1, MS4024PAE row, Recommended DC Overcurrent Device column
Printed as "up to four MS-PAE Series inverters can be connected together" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 10). The manual says parallel operation requires the ME-RTR router.
Printed as "AC wiring must be no less than #10 AWG (5.3 mm2) gauge copper wire" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 27). The same statement covers AC input and output wiring.
Where: PDF page 27, 2.3.1 Pre-AC Wiring Requirements
Stack/Accessories Port (red label): a RJ45 port that connects to the ME-RTR router; Network Port (green label): a RJ11 port that accepts optional network-capable accessories; Remote Port (blue label): a RJ11 port that allows optional remote control displays to be connected
Printed as "Stack/Accessories Port (red label) – a RJ45 port", "Network Port (green label) – a RJ11 port", "Remote Port (blue label) – a RJ11 port" and "Battery Temp Sensor Port (yellow label) – a RJ11 port" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 12).
Where: PDF page 12, 1.2 Features and Benefits, items 3 to 6
ETL Listed to ANSI/UL1741, 1st edition, and CSA STD C22.2 No. 107.1-01
Manufacturer claim recorded as printed in the owner's manual. The MS4024PAE page also lists an authorization to mark titled "ATM (MS4448, MS4024AE, MS4024PAE and MS4448PAE UL1741 & CSA) Issued 28 Dec 2018"; that document was not read.
Printed as "4,000 W Continuous power" on the MS4024PAE page; the owner's manual prints "4000 VA (L-L)" at 25 °C. Read from the MS4024PAE column (the first of two) of the MS-PAE Series owner's manual 64-0032 Rev E (July 2026).
Where: Product page headline figures; owner's manual Appendix A, Continuous power output row
above or under a horizontal surface (shelf or table); on a vertical surface (wall) with the DC terminals toward the bottom, the MP-HOOD (inverter hood) installed over the exhaust vents (top), and either the ME-CB or MPX-CB (Conduit box), the MMP Series (single inverter enclosure), or the MP Series (multiple inverter enclosure) attached to the inverter’s DC end (bottom).
Printed as "above or under a horizontal surface (shelf or table)" and "on a vertical surface (wall) with the DC terminals toward the bottom" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 18). For wall mounting the manual also requires the MP-HOOD over the exhaust vents and a conduit box or MMP/MP Series enclosure on the DC end.
27.0 A at 120 VAC (L-N); 16.7 A at 240 VAC (L-L) Check note
The product page prints a different output current. DMX Power's MS4024PAE page prints "40 A Output current". The MS-PAE Series owner's manual (64-0032 Rev E) prints the continuous AC output current as 27.0 A at 120 VAC and 16.7 A at 240 VAC, and 40 A (L-L) as the 100 millisecond surge current. The manual's continuous figures are recorded.
Printed as "L-N: 27.0 A/120 VAC, L-L: 16.7 A/240 VAC". Read from the MS4024PAE column (the first of two).
Where: Owner's manual Appendix A, Continuous AC output current row
Printed as "Torque DC cable connections from 10 to 12 ft lbf (13.6 to 16.3 Nm)" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 20). Sections 2.2, 2.2.3 and 2.2.6 print the same range.
Printed as "18.0 to 34.0 VDC" in the owner's manual and a range of 18 to 34 V on the page; the absolute maximum DC input is 50 VDC. Read from the MS4024PAE column (the first of two).
Where: Owner's manual Appendix A, Input battery voltage range row; product page Charging table
The AC output neutral conductor and the DC negative conductors are not connected (bonded) to the inverter chassis
Printed as "The AC output neutral conductor and the DC negative conductors" and "conductors are not connected (bonded) to the inverter chassis" in the MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power) (PDF page 3).
Where: PDF page 3, Product Safety Information, Safety Precautions
Powerful and long-lasting Low Frequency (LF) inverter!
Software
★★★★★5/5
Reliability
★★★★★5/5
Build quality
★★★★★5/5
Ease of install
★★★★★5/5
Purchased from Northern Arizona Wind and Solar (now NAZ Solar) the AIO-like version of the pre-assembled "Magnum MS4024PAE, Midnite Solar E-panel, Midnite Solar Classic 150 MPPT", as this yielded a 5-year warranty (increased from the 3-year warranty of a standalone inverter).
System installation guide was extremely helpful, guiding us through the installation & connection steps of this 24v 4000w LF inverter, and giving us a set of test steps that verified the installation. It is "AIO-like" because all connections are wired into the E-panel only, much like an AIO. Setup was easy via the front panel controls.
It has handled everything we've thrown at it, load-wise, due to it's Low Frequency (LF) architecture, as opposed to the HF nature of AIO's. It has excellent surge characteristics, among many other features. Perhaps the most outstanding benefit has been that it has lasted way beyond it's 5-year warranty, and is still going strong today.
As DMX Power continues the Magnum Energy tradition of building, selling, and supporting these inverter units *IN THE USA* (they are in Michigan), it should be possible to buy another inverter of the same model, many years later, if the inverter ever fails.
DMX Power's line of Magnum Energy inverters are highly recommended by myself, and by others on DIYsolarforum. You may contact me by DM on diysolarforum.com
Lowest first. Each price is the date we last read it; it may have changed. Stock isn't shown.
Store
Price
Read
Details
Source
Amazon
Sold by The Factory Depot
$2,321.60
Price as of Nov 16, 2026, 4:52 AM PST, may change
Nov 16, 2026
Price from the Amazon Creators API for the New-condition featured offer. Price checked Nov 16, 2026, 4:52 AM PST.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
View now Paid link. As an Amazon Associate we earn from qualifying purchases.
Amazon
See Amazon
Visit Amazon Paid link. As an Amazon Associate we earn from qualifying purchases.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Price history
No seller price history.
Quick reference sheet
Continuous output
4 kW
Battery voltage
18 to 34 V
Solar input
Not statedMPPT trackersNot stated
AC output
120/240 VAC split phase
Warranty
3 years
Size
22.74 L* (Calculated from published dimensions)W: 321 × H: 203 × L: 349 mm / W: 12.6 × H: 7.99 × L: 13.7 inWeight24.9 kg / 54.9 lb
Evidence score
4/100Missing details30% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term3 years3.6 / 30.0
3 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
DMX Power's Limited Warranty Policy (#66-0348) says all Magnum Series inverters and inverter chargers are warranted for three years from the date of purchase or 42 months from the date of manufacturing, whichever occurs first; the product page prints "3 yr Warranty". The policy says the warranty is non-transferable and applies only to products bought through authorized channels.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
3 years
DMX Power's Limited Warranty Policy (#66-0348) says all Magnum Series inverters and inverter chargers are warranted for three years from the date of purchase or 42 months from the date of manufacturing, whichever occurs first; the product page prints "3 yr Warranty". The policy says the warranty is non-transferable and applies only to products bought through authorized channels.
Location: Appendix A, Table A-1, MS-PAE Specifications (page 49)
Retrieved Oct 2, 2026
DMX Power's owner's manual for the MS4024PAE and MS4448PAE, linked from the MS4448PAE page. The file name says revision F; the document itself prints "64-0032 Rev E" and July 2026. Figures are read from the MS4448PAE column of Table A-1.
Archived copies
Archived copy of a document published by DMX Power, LLC. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
DMX Power's Limited Warranty Policy, linked from each Magnum model page. It names Magnum Series inverters and inverter chargers among the covered products and sets their warranty period. It prints no issue date.
Archived copies
Archived copy of a document published by DMX Power, LLC. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Location: Model heading, headline figures and Specifications tables
Retrieved Oct 9, 2026
DMX Power's catalog page for the MS4024PAE, captured on October 9, 2026. It prints the model's headline figures, its tables and a 3 year warranty, lists two authorization-to-mark documents and links the MS-PAE Series owner's manual and the DMX Power warranty policy.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
MS-PAE Series Owner's Manual, 64-0032 Rev E, July 2026 (DMX Power)
Archived copy of a document published by DMX Power, LLC. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
DMX Power Limited Warranty Policy, Document #66-0348 (DMX Power)
Archived copy of a document published by DMX Power, LLC. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.