Share a unified grounding grid with the PCS; connect PE wires to the dedicated grounding terminals with copper lugs
Printed as "The battery system shall share a unified grounding grid with PCS to ensure equipotential bonding and avoid ground loops." in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (pages 8 and 28). Section 4.5.3.6 continues: "Connect PE wires to dedicated grounding terminals marked with the "〨" symbol. Use copper lugs crimped with conductive paste to enhance contact." Section 2.2.2 adds "Ensure that the ground cable is securely connected."
Where: PDF pages 8 and 28, section 4.5.3.6 Battery System Grounding Requirements; section 2.2.2 Operation Precautions
At least 300 mm above and on each side of a floor-mounted column; 300 mm to 800 mm between two columns
Printed as "Ground 300mm ≤d≤800mm ≥300mm ≥300mm" in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (page 15). Read with the rendered Figure 4.2, which places the ≥300 mm marks above the column and at both sides, and 300 mm ≤ d ≤ 800 mm between two columns.
Where: PDF page 15, section 4.2, Figure 4.2 Floor-mounted installation
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "Easy installation with modular and stacked design" and "Floor/Wall mount". Classified as Stackable from the maker's own words for this model; the maker also prints wall/floor mounting, quoted here.
Location: ALP LV Battery System ALP 5.0L-E1 AU datasheet (Growatt, file dated 202601), page 1, feature list (image-only page, read by OCR); page 2, Installation method row (image-only page, read by OCR)
Communications
CAN
Printed as "Communication port CAN".
Where: Chapter 7 Technical Specifications, PDF page 35, row "Communication port", first column (ALP 5.0L-E1)
Two editions of Growatt's AU manual print different maximum currents. The recorded GR-UM-468-A-03 edition (202609) of the ALP 5.0L-E1 AU user manual prints 80A; the earlier GR-UM-308-A-01 edition (202407) prints 90A. The newer edition is shown first.
Printed as "80A" in the ALP 5.0L-E1 column of the "Max Charging/discharging current" row, one figure for charging and discharging.
Where: Chapter 7 Technical Specifications, PDF page 35, row "Max Charging/discharging current", first column (ALP 5.0L-E1)
Sources
90 A
Printed as "90A" for ALP 5.0L-E1 in the 202407 edition's "Max Charging/discharging" row, one figure for both directions.
The maker's GR-UM-308-A-01, source file edition 2407 prints Rated Capacity/Energy 4.6 kWh, not Usable Energy. No usable-energy or DoD definition establishes that figure as usable. No DoD arithmetic or relabelling is used. The printed rated value remains as a dated alternative beside the nominal primary.
Where: ALP E1-AU manual PDF pages 16 and 17 / printed pages 27 to 30, exact named model column, Rated Capacity/Energy row
Printed as "sixteen serial connection (1P16S)" in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (pages 4 and 35). Each ALP 5.0L battery module is 100 Ah cells in sixteen-cell series; the Battery Designation row of the chapter 7 table prints "[(1P16S)1P]" for this model.
Where: PDF pages 4 and 35, section 1.1 Intended Use
ALP 5.0L battery (1), positive parallel power cable (1), negative parallel power cable (1), parallel communication cable (1), parallel ground cable (1), left trim cover (1), right trim cover (1), anti-tipping plate (2), M6 expansion bolt (2), M4x9 stainless steel screw (8), battery connecting piece (2), quick installation manual (1), warranty card (1), certificate of conformity (1)
Printed as "Anti-tipping plate 2* M6 expansion bolt 2* M4x9 stainless steel screw 8*" in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (page 18). Item list read with the rendered Fig 4.5. The wall bracket, base and longer cables in Fig 4.6 Parts list are separate accessories chosen by installation method.
Where: PDF page 18, section 4.4.2 Check the Packing List, Fig 4.5 ALP 5.0L packing list
Growatt's manual editions print different rated energy. The newer GR-UM-468-A-03 manual and E1-AU datasheet print rated energy 5 kWh; the earlier GR-UM-308-A-01, source file edition 2407 prints rated energy 4.6 kWh. The nominal primary is unchanged. Both editions are retained with their scope; the earlier rated figure is not called usable.
Printed as "100Ah/5kWh" in the ALP 5.0L-E1 column of the manual's Nominal Capacity/Energy row; the Rated Capacity/Energy row prints the same figures.
Where: Chapter 7 Technical Specifications, PDF page 35, row "Nominal Capacity/Energy", first column (ALP 5.0L-E1)
Sources
4.6 kWh
GR-UM-308-A-01, source file edition 2407; printed Rated Capacity/Energy 4.6 kWh for this exact named configuration. This is the edition's rated figure, not a usable-energy claim and not a calculated quantity.
PCS: CAN communication; LINK-IN: CAN communication; LINK-OUT: CAN communication; USB interface
Printed as "2 PCS CAN communication" in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (page 5). Ports of each ALP 5.0L battery module's operation panel.
Where: PDF page 5, section 1.2.2 Introduction to the battery operation panel
Two editions of Growatt's AU manual print different maximum power figures. The recorded GR-UM-468-A-03 edition (202609) of the ALP 5.0L-E1 AU user manual prints 4kW; the earlier GR-UM-308-A-01 edition (202407) prints 4.5kW. The newer edition is shown first.
Printed as "4kW" maximum charging/discharging power for ALP 5.0L-E1.
Where: Chapter 7 Technical Specifications, PDF page 35, row "Max Charging/discharging power", first column (ALP 5.0L-E1)
Sources
4.5 kW
Printed as "4.5kW" for ALP 5.0L-E1 in the 202407 edition's "Max Charging/discharging" row, one figure for both directions.
Two editions of Growatt's AU manual print different maximum currents. The recorded GR-UM-468-A-03 edition (202609) of the ALP 5.0L-E1 AU user manual prints 80A; the earlier GR-UM-308-A-01 edition (202407) prints 90A. The newer edition is shown first.
Printed as "80A" in the ALP 5.0L-E1 column of the "Max Charging/discharging current" row, one figure for charging and discharging.
Where: Chapter 7 Technical Specifications, PDF page 35, row "Max Charging/discharging current", first column (ALP 5.0L-E1)
Sources
90 A
Printed as "90A" for ALP 5.0L-E1 in the 202407 edition's "Max Charging/discharging" row, one figure for both directions.
Do not turn the PACK upside down, and ensure that the floor is level
Printed as "Do not turn the PACK upside down, and ensure that the floor is level." in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (page 15). Figure 4.2 shows the floor-mounted column at 90° to the ground.
Where: PDF page 15, section 4.2 Basic installation requirements
Printed as three storage bands: -20 to 25 ℃ for 12 months, 25 to 35 ℃ for 9 months and 35 to 50 ℃ for 6 months, humidity 5% to 95% RH; the range recorded spans the three bands, each with its own time limit.
Where: Chapter 7 Technical Specifications, PDF page 35, row "Storage conditions", first column (ALP 5.0L-E1)
Two editions of Growatt's AU manual print different maximum power figures. The recorded GR-UM-468-A-03 edition (202609) of the ALP 5.0L-E1 AU user manual prints 4kW; the earlier GR-UM-308-A-01 edition (202407) prints 4.5kW. The newer edition is shown first.
Printed as "4kW" maximum charging/discharging power for ALP 5.0L-E1.
Where: Chapter 7 Technical Specifications, PDF page 35, row "Max Charging/discharging power", first column (ALP 5.0L-E1)
Sources
4.5 kW
Printed as "4.5kW" for ALP 5.0L-E1 in the 202407 edition's "Max Charging/discharging" row, one figure for both directions.
Printed as "The whole battery system communicates to Power Conversion System (PCS) via CAN." in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (page 6). The PCS port pin definition (section 4.5.3.1) lists CAN_H and CAN_L.
Where: PDF page 6, section 1.3 Working Principle and Function
Two editions of Growatt's AU manual print different operating temperature ranges. The recorded GR-UM-468-A-03 edition (202609) of the ALP 5.0L-E1 AU user manual prints -10°C~50°C; the earlier GR-UM-308-A-01 edition (202407) prints 0°C~50°C. The newer edition is shown first.
Printed as "Operative temperature range -10°C~50°C".
Where: Chapter 7 Technical Specifications, PDF page 35, row "Operative temperature range", first column (ALP 5.0L-E1)
Sources
0 to 50 °C
Printed as "Operative temperature range 0°C~50°C" in the 202407 edition; its label also prints an operating ambient temperature of 0°C ~ +50°C.
37.66 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 690 × H: 295 × D: 185 mm / W: 27.2 × H: 11.6 × D: 7.28 in44 kg / 97 lb0.13 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
13/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
48 V · Stackable · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Printed as a 10-year warranty in the datasheet table ("Warranty 10 years" for E1; "Warranty: 10 years Yes" for E2); read from the rendered image-only page. The datasheet does not state what the term covers or its conditions.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1973manufacturer claimpresent at observation[1]
Scope
cell
Covered models
ALP 5.0L-E1
Limitations
A manufacturer claim at cell level, not a listing or certificate. Printed as "Cell safety certification IEC62619/UL1973" (row 21) in chapter 7, Technical Specifications, of Growatt's ALP 5.0L-E1 Battery System User Manual (GR-UM-468-A-03, file dated 202609, au.growatt.com), page 32 (PDF page 35), in the table whose Battery Model columns are ALP 5.0L-E1 and ALP 10.0L-E1; the row spans both columns. The table's separate PACK certification row (row 22) does not list UL 1973. Captured September 29, 2026. Cell scope does not certify the assembled battery. No issuer, certificate or report number is printed; the issuer's record was not checked.
Printed as a 10-year warranty in the datasheet table ("Warranty 10 years" for E1; "Warranty: 10 years Yes" for E2); read from the rendered image-only page. The datasheet does not state what the term covers or its conditions.
Growatt's own document, the file Growatt publishes as https://en.growatt.com/upload/file/ALP_5.0L-E1-AU_User_Manual_EN.pdf, in the copy hosted by the distributor www.gosolar.com.au and fetched there on September 29, 2026 after www.gosolar.com.au's robots.txt allowed the path; the bytes are Growatt's file (it prints Growatt's name and the model), not a distributor document. Growatt's own copy sits under /upload/, which Growatt's robots.txt disallows, so it was never requested. An earlier edition of the Australian ALP 5.0L-E1 manual than the GR-UM-468-A-03 edition (202609) the records already cite. Its chapter 7 tables print ALP 5.0L-E1 to ALP 40.0L-E1 (it does not cover 45.0L or 50.0L), and its label (Fig 2.2) prints each system model with its rated current, capacity and energy. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Page text and download list
Retrieved Sep 28, 2026
Growatt's Australian product page for the ALP LV Battery (ALP 5.0L-E1), captured September 29, 2026. Cited for the product name, the market it is published for and the links to the AU datasheet and the user manual. Its feature list is marketing text, not a specification table. Manufacturer claims, not independently verified.
UL 1973Manufacturer claim · cellClaimedListed when checked
A manufacturer claim at cell level, not a listing or certificate. Printed as "Cell safety certification IEC62619/UL1973" (row 21) in chapter 7, Technical Specifications, of Growatt's ALP 5.0L-E1 Battery System User Manual (GR-UM-468-A-03, file dated 202609, au.growatt.com), page 32 (PDF page 35), in the table whose Battery Model columns are ALP 5.0L-E1 and ALP 10.0L-E1; the row spans both columns. The table's separate PACK certification row (row 22) does not list UL 1973. Captured September 29, 2026. Cell scope does not certify the assembled battery. No issuer, certificate or report number is printed; the issuer's record was not checked.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Chapter 7, Technical Specifications (PDF pages 35 to 39)
Retrieved Sep 28, 2026
Growatt's English user manual for the ALP 5.0L-E1 battery system, linked from the Australian ALP 5.0L-E1 page and served from au.growatt.com, captured September 29, 2026. Chapter 7 prints one technical table per pair of configurations, from one pack (ALP 5.0L-E1) to ten packs (ALP 50.0L-E1). The primary source for these records. Manufacturer claims, not independently verified.
Archived copies
Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
User Manual, ALP 5.0L-E1 Battery System (Growatt, GR-UM-468-A-03, file dated 202609)
Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
ALP LV Battery System ALP 5.0L-E1 AU datasheet (Growatt, file dated 202601)
Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
User Manual, ALP 5.0L-E1-AU Battery System (Growatt, GR-UM-308-A-01, 202407 edition) (Growatt's own file, copy hosted by distributor www.gosolar.com.au)
Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
ALP 5.0L-E1
Manufacturer SKU unknown · AU market
Observed Sep 29, 2026
UL 1973: claimed
Cell / component only. A manufacturer claim at cell level, not a listing or certificate. Printed as "Cell safety certification IEC62619/UL1973" (row 21) in chapter 7, Technical Specifications, of Growatt's ALP 5.0L-E1 Battery System User Manual (GR-UM-468-A-03, file dated 202609, au.growatt.com), page 32 (PDF page 35), in the table whose Battery Model columns are ALP 5.0L-E1 and ALP 10.0L-E1; the row spans both columns. The table's separate PACK certification row (row 22) does not list UL 1973. Captured September 29, 2026. Cell scope does not certify the assembled battery. No issuer, certificate or report number is printed; the issuer's record was not checked.