Read from Growatt's published document at https://us.growatt.com/upload/file/SPF_3000-5000_ES_Datasheet_EN_202405.pdf, from the specification column headed SPF 3500 ES. Printed value: "11.5kg". Conditions as stated on that sheet. No value was taken from another model or from a name.
Printed as "1/1" in the Growatt SPF 3000-5000 ES datasheet (EN 202405), Solar charger, "Number of independent MPP trackers/ strings per MPP tracker" row, SPF 3500 ES column, captured on September 25, 2026. The first figure of the printed pair is the number of MPP trackers.
Where: Solar charger, "Number of independent MPP trackers/ strings per MPP tracker" row, SPF 3500 ES column
Printed as "Surge power 7000VA" in the Growatt SPF 3000-5000 ES datasheet (EN 202405), Inverter output, "Surge power" row, SPF 3500 ES column, captured on September 25, 2026. The datasheet prints no duration for the surge figure.
Where: Inverter output, "Surge power" row, SPF 3500 ES column
Printed as "Max. Charging Current (AC Charger Plus Solar Charger) 80A" in the Growatt SPF 3500-5000 ES User Manual (2021-09), Table 3, captured on September 26, 2026. Value for this model.
W 330 × H 485 × D 135 mm / W 13 × H 19.1 × D 5.31 in converted
Printed as "Dimension (W/H/D) 330/485/135mm" in the Growatt SPF 3000-5000 ES datasheet (EN 202405), Physical, "Dimension (W/H/D)" row, SPF 3500 ES column, captured on September 25, 2026.
Where: Physical, "Dimension (W/H/D)" row, SPF 3500 ES column
Printed as "Connect the end of RJ45 of battery to BMS communication port(RS485 or CAN) of inverter." in the Growatt SPF 3500-5000 ES User Manual (2021-09), chapter 6, captured on September 26, 2026.
Printed as "Efficiency (Peak) 93%" in the Growatt SPF 3000-5000 ES datasheet (EN 202405), Inverter output, "Efficiency (Peak)" row, SPF 3500 ES column, captured on September 25, 2026.
Where: Inverter output, "Efficiency (Peak)" row, SPF 3500 ES column
Printed as "Maximum PV array power 4500W" in the Growatt SPF 3000-5000 ES datasheet (EN 202405), Solar charger, "Maximum PV array power" row, SPF 3500 ES column, captured on September 25, 2026.
Where: Solar charger, "Maximum PV array power" row, SPF 3500 ES column
Printed as "Max. AC Charging Current 60Amp" in the Growatt SPF 3500-5000 ES User Manual (2021-09), Table 3, captured on September 26, 2026. Value for this model.
Printed as "Output Voltage Waveform Pure Sine Wave" in Table 2 of Growatt's SPF 3500/5000 ES user manual.
Where: User manual Table 2 Inverter Mode Specifications, Output Voltage Waveform row (one value for SPF 3500 ES and 5000 ES), PDF page 39; spec-table row
Printed as "230VAC ± 5% @ 50/60Hz" in the Growatt SPF 3000-5000 ES datasheet (EN 202405), Inverter output, "AC voltage regulation (battery mode)" row, SPF 3500 ES column, captured on September 25, 2026.
Where: Inverter output, "AC voltage regulation (battery mode)" row, SPF 3500 ES column
Read from Growatt's published document at https://us.growatt.com/upload/file/SPF_3000-5000_ES_Datasheet_EN_202405.pdf, from the specification column headed SPF 3500 ES. Printed value: "IP20". Conditions as stated on that sheet. No value was taken from another model or from a name.
Printed as "Surge Capacity 2* rated power for 5 seconds" in the Growatt SPF 3500 ES / SPF 5000 ES User Manual (EN, V4.0), Table 2, captured September 27, 2026. Same for both models.
Printed as "Transfer Time 10ms typical, 20ms Max@ Single <30ms @ Parallel" in the Growatt SPF 3500-5000 ES User Manual (2021-09), Table 1, captured on September 26, 2026.
Printed as "Rated Output Power 3.5KVA/3.5KW 5KVA/5KW" in Growatt's SPF 3500 ES / SPF 5000 ES User Manual (EN, 2021-09), Table 2 Inverter Mode Specifications (columns "INVERTER MODEL SPF 3500 ES SPF 5000 ES"); "3.5KVA/3.5KW" is the SPF 3500 ES (first) column. The 3.5 kVA figure is recorded in VA; the 3.5 kW figure is the one already recorded under continuous_output_kw.
Where: User Manual, Table 2 Inverter Mode Specifications, "Rated Output Power" row, SPF 3500 ES column, PDF page 39
Printed as "Rated Output Power 3.5KVA/3.5KW 5KVA/5KW" in the Growatt SPF 3500 ES / SPF 5000 ES User Manual (EN, V4.0), Table 2, SPF 3500 ES column, captured September 27, 2026.
Where: Specifications, Table 2 Inverter Mode Specifications, Rated Output Power row, SPF 3500 ES column
Printed as "SPF 3500 ES 1 * 4 AWG 2-3 Nm" in the Growatt SPF 3500-5000 ES User Manual (2021-09), chapter 5, Recommended battery cable and terminal size, captured on September 26, 2026.
Printed as "Input Voltage Waveform Sinusoidal (utility or generator)" in the Growatt SPF 3500-5000 ES User Manual (2021-09), Table 1, captured on September 26, 2026.
Printed as "Battery voltage 48VDC" in the Growatt SPF 3000-5000 ES datasheet (EN 202405), Battery voltage row, SPF 3500 ES column, captured on September 25, 2026.
Printed as "No Load Power Consumption <60W" in the Growatt SPF 3500 ES / SPF 5000 ES User Manual (EN, V4.0), Table 2, captured September 27, 2026. Same for both models.
Where: Specifications, Table 2 Inverter Mode Specifications, No Load Power Consumption row
Printed as "Parallel operation in single phase with up to 6 units." in the Growatt SPF 3500-5000 ES User Manual (2021-09), Parallel Installation Guide, captured on September 26, 2026.
Read from Growatt's published document at https://us.growatt.com/upload/file/SPF_3000-5000_ES_Datasheet_EN_202405.pdf, from the specification column headed SPF 3500 ES. Printed value: "150V". Conditions as stated on that sheet. No value was taken from another model or from a name.
Printed as "SPF 3500 ES 1 * 4 AWG 2-3 Nm" in the Growatt SPF 3500-5000 ES User Manual (2021-09), chapter 5, captured on September 26, 2026. Battery terminals; the AC and PV terminal tables print 1.2-1.6 Nm.
Printed as "SPF 3500 ES 1 * 10 AWG 1.2-1.6 Nm" in the Growatt SPF 3500-5000 ES User Manual (2021-09), chapter 9, captured on September 26, 2026. The table covers AC input and output wires.
Where: Chapter 9, Suggested cable requirement for AC wires
Read from Growatt's published document at https://us.growatt.com/upload/file/SPF_3500-5000_ES_User_Manual_EN_202109.pdf, from the specification column headed SPF 3500 ES. Printed value: "3.5KVA/3.5KW". Conditions as stated on that sheet. No value was taken from another model or from a name.
Lead-acid (AGM or flooded) 48V; lithium only as configured by Growatt, with BMS communication over RS485 or CAN
Printed as "User can choose proper capacity lead acid battery with a nominal voltage at 48V ... you are allowed to use the lithium battery only which we have configured." in the Growatt SPF 3500-5000 ES User Manual (2021-09), chapters 5 and 6, captured on September 26, 2026.
Printed as "The recommended spec of AC breaker is 40A for SPF 3500 ES and 50A for SPF 5000 ES." in the Growatt SPF 3500-5000 ES User Manual (2021-09), chapter 9, captured on September 26, 2026.
21.61 L* (Calculated from published dimensions)W: 330 × H: 485 × D: 135 mm / W: 13 × H: 19.1 × D: 5.31 inWeight11.5 kg / 25.4 lb
Evidence score
1/100Missing details10% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Idle consumption60 W1.3 / 10.0
60 against 8 W, the lowest documented for an inverter in the 1.5 to 3.5 kW output band (printed by the maker): Victron Energy Inverter 12/2000 Smart
Printed as "No Load Power Consumption <60W" in the Growatt SPF 3500 ES / SPF 5000 ES User Manual (EN, V4.0), Table 2, captured September 27, 2026. Same for both models. Printed as a bound: less than 60 W, as printed.
Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Remedy
Service replacement or service repair under the warranty terms
Printed as "Growatt’s responsibility is limited to service replace and service repair according to the warranty terms & conditions" on Growatt USA's warranty page, captured on September 26, 2026.
Printed as "Country and Region coverage : United States." on Growatt USA's warranty page, service terms item (2), captured on September 26, 2026. The page covers Growatt solar and storage inverters.
Excludes damage from opening the casing without permission, transport, incorrect installation or commissioning, not following the manual, unauthorized modification or repair, incorrect use, insufficient ventilation, ignoring safety regulations and force majeure; a serial number is needed to claim
Printed on Growatt USA's warranty page under Other important notice (2) as a list of exclusions beginning "Breaking the product seal / opening the casing without permission from Growatt", captured on September 26, 2026; item (3) says a serial number must in general be provided to claim.
Where: Other important notice, item (2); Service terms & conditions, item (3)
Date of installation, and no more than 5 and half years from the date of delivery from the Growatt factory
Printed as "... from the date of installation, and no more than 5 and half years from the date of delivery from Growatt factory" on Growatt USA's warranty page, service terms item (3), captured on September 26, 2026. The page defers to the warranty card and any sales contract.
Growatt pays freight for products under warranty, only to the original selling country or region; customers pay customs clearance; Growatt does not offer installation service
Printed as "Growatt takes on the freight cost for products under warranty (Note: this is only to the devices’ original selling country/region)" and "Growatt don’t offer installation service" on Growatt USA's warranty page, captured on September 26, 2026.
Where: Freight cost, item (1); Growatt service commitment, item (4)
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: Service terms & conditions; Freight cost; Other important notice
Retrieved Sep 25, 2026
Growatt USA's own warranty page, captured on September 26, 2026. Its service terms cover Growatt solar inverters, storage inverters, monitoring devices and software in the United States; it defers to the warranty card and any sales contract, and it does not name individual models or battery products.
Captured with a plain HTTPS GET and a browser user agent.
Location: SPF 3000-5000 ES | Single Phase Off-Grid | Growatt
Retrieved Sep 19, 2026
Growatt's own US product page for the SPF 3000-5000 ES family, captured as delivered HTML. It establishes what Growatt published on that page on the access date and nothing more: it is a family page, so it is used here only for the product photo and only for the models the page title or the photo's own caption names. No specification, rating or part number was taken from it.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Growatt user manual
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].