About brandDuracell Power Center, whose site carries a Power Center copyright and whose datasheets give a San Jose, California address, sells home battery storage, hybrid inverters, microinverters and an EV charger under the Duracell trademark, which its site says is used under license from Duracell U.S. Operations, Inc. Its datasheets say the products are manufactured under license and warranty supported by Omega Green Power in San Jose.
SKU detail
locator: Manual cover and spec sheet heading
conditions: Printed as "MAX HYBRID 15 KW INVERTER" on the cover of Duracell Power Center's operation manual and as "MAX HYBRID 15" on its spec sheet page; the manual prints no separate part number, so the model name is recorded. Its warranty page is headed "Max Hybrid 15-2P Limited Warranty".
The system must have Ground connections and Neutral connections.; Solar PV+/PV- are UNGROUNDED.
Printed as "The system must have Ground connections and Neutral connections" and "Solar PV+/PV- are UNGROUNDED" in the Duracell Power Center Max Hybrid 15 kW Inverter Operation Manual (PDF page 4). The specification sheet pages of this manual have a garbled text layer and were not used.
24,000VA L-L (240V) for 10 s; 30,000VA L-L (240V) for 100 ms
Printed as "24,000VA L-L (240V)" in the Surge AC Power 10sec row and "30,000VA L-L (240V)" in the Surge AC Power 100ms row of the spec sheet in Duracell Power Center's Max Hybrid 15 operation manual, read from rendered PDF page 6.
Printed as "2” Minimum Horizontal Clearance || 6” Minimum Vertical" in the Duracell Power Center Max Hybrid 15 kW Inverter Operation Manual (PDF page 7).
Where: PDF page 7, Clearance note beside the torque table
Printed as "Max Hybrid 15 is a 48V system. Do NOT wire the battery bank to any other nominal voltage." in Duracell Power Center's Max Hybrid 15 operation manual.
Printed as "Max Hybrid 15 Torque Values Application Note" and "Load Terminal Block 62 IN Lbs 7 NM" and "Grid Terminal Block 62 IN Lbs 7 NM" in the Duracell Power Center Max Hybrid 15 kW Inverter Operation Manual (PDF page 7). Printed as "62 IN Lbs 7 NM" for the Load, Grid and Gen terminal blocks.
Where: PDF page 7, Max Hybrid 15 Torque Values table, Load, Grid and Gen Terminal Block rows
Printed as "Max Hybrid 15 Torque Values Application Note" and "Neutral / Ground Busbars 15.5 IN Lbs 1.75 NM" in the Duracell Power Center Max Hybrid 15 kW Inverter Operation Manual (PDF page 7). Printed as "15.5 IN Lbs 1.75 NM".
Where: PDF page 7, Max Hybrid 15 Torque Values table, Neutral / Ground Busbars row
Printed as "Max Hybrid 15 Torque Values Application Note" and "Battery Connection 90.0 IN Lbs 10 NM" in the Duracell Power Center Max Hybrid 15 kW Inverter Operation Manual (PDF page 7). Printed as "90.0 IN Lbs 10 NM".
Where: PDF page 7, Max Hybrid 15 Torque Values table, Battery Connection row
Ground MUST be bonded to Neutral ONLY ONCE in the circuit.
Printed as "Ground MUST be bonded to Neutral ONLY ONCE in the circuit" in the Duracell Power Center Max Hybrid 15 kW Inverter Operation Manual (PDF page 4).
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term10 years12.0 / 30.0
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Duracell Power Center provides a Ten-year (10) limited Warranty" against defects in materials and workmanship, under the heading "10-Year Limited Warranty for Duracell Power Center Products" in the operation manual; the terms and their conditions are on that page.
90 against 1 W, the lowest documented for an inverter in the 7 to 15 kW output band (printed by the maker): Fronius Primo 11.4-1 208-240. The bar is a printed bound: less than 1 W, as printed.
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CECauthority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
Max Hybrid 15
Limitations
Model Max Hybrid 15 listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Power Center, as "Max Hybrid 15 {208V}"; "Max Hybrid 15 {240V}", CEC listing date 2023-11-13. This is an equipment listing, not UL certification or complete-system approval.
CECauthority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
Max Hybrid 15
Limitations
Model Max Hybrid 15 listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Power Center, as "Max Hybrid 15 {208V}"; "Max Hybrid 15 {240V}", CEC listing date 2023-11-13. This is an equipment listing, not UL certification or complete-system approval.
Printed as "Duracell Power Center provides a Ten-year (10) limited Warranty" against defects in materials and workmanship, under the heading "10-Year Limited Warranty for Duracell Power Center Products" in the operation manual; the terms and their conditions are on that page.
Location: Spec Sheet (page 5, PDF page 6); Mounting the Max Hybrid 15; Integrating batteries; Limited Warranty
Retrieved Oct 3, 2026
Duracell Power Center's own 66-page operation manual for the Max Hybrid 15, captured October 3, 2026. Its spec sheet page (page 5) prints labels and values in separate text runs, so values were read against the page rendered locally (PDF page 6). Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Duracell Power Center. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Operation Manual, MAX HYBRID 15 KW INVERTER, Duracell Power Center (duracellpowercenter.com, October 3, 2026 capture)
Archived copy of a document published by Duracell Power Center. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
Max Hybrid 15
Manufacturer SKU Max Hybrid 15 · US market
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model Max Hybrid 15 listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Power Center, as "Max Hybrid 15 {208V}"; "Max Hybrid 15 {240V}", CEC listing date 2023-11-13. This is an equipment listing, not UL certification or complete-system approval.
Product / system scope unresolved. Model Max Hybrid 15 listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Power Center, as "Max Hybrid 15 {208V}"; "Max Hybrid 15 {240V}", CEC listing date 2023-11-13. This is an equipment listing, not UL certification or complete-system approval.