Key specs

Continuous output3.5 kW
Weight12 kg / 26 lb converted
Nominal voltage48 V
Efficiency93 %
AC frequency50Hz/60Hz (Auto detection)

All specifications

Identity

BrandGrowatt · Website
ModelSPF 3500 US
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
Weight12 kg / 26 lb converted
Printed as "Net weight 12kg(26.5lb)" in the Growatt SPF 3500-5000 US datasheet (EN 202405), Physical, "Net weight" row, SPF 3500 US column, captured on September 25, 2026.
Where: Physical, "Net weight" row, SPF 3500 US column
[1]
MPPT count1 count
Printed as "1/1" in the Growatt SPF 3500-5000 US datasheet (EN 202405), Solar charger, "Number of independent MPP trackers/ strings per MPP tracker" row, SPF 3500 US column, captured on September 25, 2026. The first figure of the printed pair is the number of MPP trackers.
Where: Solar charger, "Number of independent MPP trackers/ strings per MPP tracker" row, SPF 3500 US column
[1]
Peak output7,000 VA (surge power)
Printed as "Surge power 7000VA" in the Growatt SPF 3500-5000 US datasheet (EN 202405), Inverter output, "Surge power" row, SPF 3500 US column, captured on September 25, 2026. The datasheet prints no duration for the surge figure.
Where: Inverter output, "Surge power" row, SPF 3500 US column
[1]
Max charge80 A
Printed as "Max. Charging Current (AC Charger Plus Solar Charger) 80A" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 3, captured on September 26, 2026. Value for this model.
Where: PDF page 22 (printed page 40), Table 3
[2]
DimensionsW 330 × H 485 × D 135 mm / W 13 × H 19.1 × D 5.31 in converted
Printed as "Dimension (W/H/D) 330/485/135mm(13/19.1/5.3in)" in the Growatt SPF 3500-5000 US datasheet (EN 202405), Physical, "Dimension (W/H/D)" row, SPF 3500 US column, captured on September 25, 2026.
Where: Physical, "Dimension (W/H/D)" row, SPF 3500 US column
[1]
CommunicationsRS485; CAN
Printed as "BMS communication port(RS485 or CAN)" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), section 3.4.3, captured on September 26, 2026.
Where: PDF page 5 (printed page 6), section 3.4.3
[2]
Efficiency93 %
Printed as "Efficiency (peak) 93%" in the Growatt SPF 3500-5000 US datasheet (EN 202405), Inverter output, "Efficiency (peak)" row, SPF 3500 US column, captured on September 25, 2026.
Where: Inverter output, "Efficiency (peak)" row, SPF 3500 US column
[1]
MPPT voltage120 to 430 V
Printed as "PV Array MPPT Voltage Range 120Vdc~430Vdc" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 3, captured on September 26, 2026.
Where: PDF page 22 (printed page 40), Table 3
[2]
Solar array4.5 kW
Converted: 4,500 W / 1000 = 4.5 kW
Printed as "Maximum PV array power 4500W" in the Growatt SPF 3500-5000 US datasheet (EN 202405), Solar charger, "Maximum PV array power" row, SPF 3500 US column, captured on September 25, 2026.
Where: Solar charger, "Maximum PV array power" row, SPF 3500 US column
Sources
Converted: 4,500 W / 1000 = 4.5 kW
[1]
AC frequency50Hz/60Hz (Auto detection)
Printed as "Output Frequency 50Hz / 60Hz (Auto detection)" in the Growatt SPF 3000TL LVM-US / SPF 3500TL LVM-US / SPF 3500 US / SPF 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2, captured September 27, 2026. Same for every model.
Where: PDF page 21 (printed page 39), Table 2 Inverter Mode Specifications, Output Frequency row
[2]
Max AC charge60 A
Printed as "Max. AC Charging Current 60Amp (@VI/P=230Vac)" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 3, captured on September 26, 2026.
Where: PDF page 22 (printed page 40), Table 3 Charge Mode Specifications
[2]
Output waveformPure sine wave
Printed as "Pure sine wave" in the Waveform row of Growatt's SPF 3500/5000 US datasheet, one merged cell across both models (read from the rendered table).
Where: Datasheet page 2, Inverter Output, Waveform row (one value spanning the SPF 3500 US and 5000 US columns); spec-table row, paired from the rendered table because the text layer lists the labels before the values
[3]
AC configuration230VAC ± 5% @ 50/60Hz (battery mode)
Printed as "230VAC ± 5% @ 50/60Hz" in the Growatt SPF 3500-5000 US datasheet (EN 202405), Inverter output, "AC voltage regulation (battery mode)" row, SPF 3500 US column, captured on September 25, 2026.
Where: Inverter output, "AC voltage regulation (battery mode)" row, SPF 3500 US column
[1]
Max PV current22 A
Printed as "Max. PV Input Current 22A" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 3, captured on September 26, 2026.
Where: PDF page 22 (printed page 40), Table 3
[2]
Max PV voltage450 V
Printed as "Max. PV Array Open Circuit Voltage 450Vdc" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 3, captured on September 26, 2026.
Where: PDF page 22 (printed page 40), Table 3
[2]
Surge duration s5 s
Printed as "Surge Capacity 2* rated power for 5 seconds" in the Growatt SPF 3000TL LVM-US / SPF 3500TL LVM-US / SPF 3500 US / SPF 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2, captured September 27, 2026. Same for every model.
Where: PDF page 21 (printed page 39), Table 2 Inverter Mode Specifications, Surge Capacity row
[2]
Transfer timetypical: 10; max single: 20; parallel: <30
Printed as "Transfer Time 10ms typical, 20ms Max@ Single <30ms @ Parallel" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 1, captured on September 26, 2026.
Where: PDF page 21 (printed page 38), Table 1 Line Mode
[2]
Battery output3.5 kW
Printed as "Rated Output Power 3.5KVA/3.5KW" in the Growatt SPF 3000TL LVM-US / SPF 3500TL LVM-US / SPF 3500 US / SPF 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2, SPF 3500 US column, captured September 27, 2026.
Where: PDF page 21 (printed page 39), Table 2 Inverter Mode Specifications, Rated Output Power row, SPF 3500 US column
[2]
Battery wire size1 * 4 AWG
Printed as "SPF 3500 US 1 * 4 AWG 2-3 Nm" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), section 3.4.2 Recommended battery cable and terminal size, captured on September 26, 2026.
Where: PDF page 4 (printed page 5), section 3.4.2
[2]
Generator supportAC input accepts utility or generator
Printed as "Input Voltage Waveform Sinusoidal (utility or generator)" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 1, captured on September 26, 2026.
Where: PDF page 21 (printed page 38), Table 1
[2]
Nominal voltage48 V
Printed as "Battery voltage 48VDC" in the Growatt SPF 3500-5000 US datasheet (EN 202405), Battery voltage row, SPF 3500 US column, captured on September 25, 2026.
Where: Battery voltage row, SPF 3500 US column
[1]
AC input wire size1 * 10 AWG
Printed as "SPF 3500 US 1 * 10 AWG 1.2-1.6 Nm" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), section 3.5 Suggested cable requirement for AC wires, captured on September 26, 2026.
Where: PDF page 6 (printed page 9), section 3.5
[2]
Idle consumption60 W
Printed as "<60W"; the figure is an upper bound.
Printed as "No Load Power Consumption <60W" in the Growatt SPF 3000TL LVM-US / SPF 3500TL LVM-US / SPF 3500 US / SPF 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2, captured September 27, 2026. The unit is operating with no connected load, not powered off.
Where: PDF page 21 (printed page 39), Table 2 Inverter Mode Specifications, No Load Power Consumption row
[2]
Max parallel units6
Printed as "1. Parallel operation in single phase with up to 6 units. 2. Maximum 6 units work together to support 3-phase equipment. Four units support one phase maximum. 3. Maximum 6 units work together to support split-phase equipment. Five units support one phase maximum." in the Growatt SPF 3000TL LVM-US / SPF 3500TL LVM-US / SPF 3500 US / SPF 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Section 5.1 Introduction, captured September 27, 2026.
Where: PDF page 13 (printed page 23), Section 5.1 Introduction
[2]
PV start voltage150 V
Printed as "Start-up Voltage 150Vdc±10Vdc" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 3, captured on September 26, 2026.
Where: PDF page 22 (printed page 40), Table 3
[2]
Terminal torque2 to 3 N·m
Printed as "SPF 3500 US 1 * 4 AWG 2-3 Nm" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), section 3.4.2, captured on September 26, 2026. Battery terminals; the AC table prints 1.2-1.6 Nm.
Where: PDF page 4 (printed page 5), section 3.4.2
[2]
AC output wire size1 * 10 AWG
Printed as "SPF 3500 US 1 * 10 AWG 1.2-1.6 Nm" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), section 3.5, captured on September 26, 2026. The table covers AC input and output wires.
Where: PDF page 6 (printed page 9), section 3.5
[2]
Continuous output3.5 kW
Printed as "3.5KVA/3.5KW" in Growatt Off Grid Solar Inverter SPF 3000TL LVM-US / SPF 3500TL LVM-US / SPF 3500 US / SPF 5000 US User Manual (Version 1.0), User manual, 9.0 Specifications, Table 2 Inverter Mode Specifications (PDF page 21, printed page 39), Rated Output Power row, SPF 3500 US column. Revised on 1 October 2026: Growatt's user manual prints the rated output power as 3.5KVA/3.5KW for this model, so the stored kilowatt value needs no conversion; the manual is the primary source.
Where: User manual, 9.0 Specifications, Table 2 Inverter Mode Specifications (PDF page 21, printed page 39), Rated Output Power row, SPF 3500 US column
[2]
Battery compatibilityLead-acid (AGM or flooded) 48V; lithium only as configured by Growatt, with BMS communication over RS485 (protocols L01 to L50) or CAN (L51 to L99)
Printed as "you are allowed to use the lithium battery only which we have configured" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), sections 3.4.1 and 3.4.3, captured on September 26, 2026. Section 3.4.4 lists RS485 protocols L01 to L50 and CAN protocols L51 to L99.
Where: PDF pages 4-5 (printed pages 5-7), sections 3.4.1 to 3.4.4
[2]
Storage temperature-15 to 60 °C / 5 to 140 °F converted
Printed as "Storage temperature -15℃~ 60℃" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 4, captured on September 26, 2026.
Where: PDF page 22 (printed page 41), Table 4
[2]
Recommended protectionAC input breaker 40A
Printed as "The recommended spec of AC breaker is 40A for SPF 3000TL LVM-US /SPF 3500TL LVM-US /SPF 3500 US /SPF 5000 US." in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), section 3.5, captured on September 26, 2026.
Where: PDF page 6 (printed page 9), section 3.5
[2]
Operating temperature0 to 55 °C / 32 to 131 °F converted
Printed as "Operating Temperature Range 0℃ to 55℃" in the Growatt SPF 3000TL LVM-US / 3500TL LVM-US / 3500 US / 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 4, captured on September 26, 2026.
Where: PDF page 22 (printed page 41), Table 4
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
3.5 kWBattery only 3.5 kW
Battery voltage
48 V
Solar input
4.5 kWMPPT trackers 1MPPT range 120 to 430 V
AC output
230VAC ± 5% @ 50/60Hz (battery mode)
Warranty
2 years
Size
21.61 L* (Calculated from published dimensions)W: 330 × H: 485 × D: 135 mm / W: 13 × H: 19.1 × D: 5.31 inWeight 12 kg / 26 lb

Evidence score

14/100Missing details85% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

CertificatesUL 1741Claimed10.2 / 45.0

Manufacturer claim; issuer verification pending. Applies to the exact inverter.

[1]

Warranty term2 years2.4 / 30.0

2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "Warranty 2 Years" in the Growatt SPF 3500-5000 US datasheet (EN 202405), Warranty row, SPF 3500 US column, captured on September 25, 2026.

[1]

Idle consumption60 W1.3 / 10.0

60 against 8 W, the lowest documented for an inverter in the 1.5 to 3.5 kW output band (printed by the maker): Victron Energy Inverter 12/2000 Smart

Printed as "No Load Power Consumption <60W" in the Growatt SPF 3000TL LVM-US / SPF 3500TL LVM-US / SPF 3500 US / SPF 5000 US User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2, captured September 27, 2026. The unit is operating with no connected load, not powered off. Printed as a bound: less than 60 W, as printed.

[2]

Research pending, 0 points: Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL 1741manufacturer claimunknown[1]
Scope
equipment listing
Covered models
SPF 3500 US
Limitations
Growatt prints "UL 1741" in the Growatt SPF 3500-5000 US datasheet (EN 202405), which names SPF 3500 US, captured on September 25, 2026. This records the standard as Growatt prints it. It is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked in this pass.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 25, 2026
Source
[1]

Warranty

FieldValueConditionsSource
RemedyService replacement or service repair under the warranty terms
Printed as "Growatt’s responsibility is limited to service replace and service repair according to the warranty terms & conditions" on Growatt USA's warranty page, captured on September 26, 2026.
Where: Other important notice, item (3)
[4]
TerritoryUnited States
Printed as "Country and Region coverage : United States." on Growatt USA's warranty page, service terms item (2), captured on September 26, 2026. The page covers Growatt solar and storage inverters.
Where: Service terms & conditions, item (2)
[4]
ConditionsExcludes damage from opening the casing without permission, transport, incorrect installation or commissioning, not following the manual, unauthorized modification or repair, incorrect use, insufficient ventilation, ignoring safety regulations and force majeure; a serial number is needed to claim
Printed on Growatt USA's warranty page under Other important notice (2) as a list of exclusions beginning "Breaking the product seal / opening the casing without permission from Growatt", captured on September 26, 2026; item (3) says a serial number must in general be provided to claim.
Where: Other important notice, item (2); Service terms & conditions, item (3)
[4]
Start basisDate of installation, and no more than 5 and half years from the date of delivery from the Growatt factory
Printed as "... from the date of installation, and no more than 5 and half years from the date of delivery from Growatt factory" on Growatt USA's warranty page, service terms item (3), captured on September 26, 2026. The page defers to the warranty card and any sales contract.
Where: Service terms & conditions, item (3)
[4]
Warranty term2 years
Printed as "Warranty 2 Years" in the Growatt SPF 3500-5000 US datasheet (EN 202405), Warranty row, SPF 3500 US column, captured on September 25, 2026.
Where: Warranty row, SPF 3500 US column
[1]
Labor and shippingGrowatt pays freight for products under warranty, only to the original selling country or region; customers pay customs clearance; Growatt does not offer installation service
Printed as "Growatt takes on the freight cost for products under warranty (Note: this is only to the devices’ original selling country/region)" and "Growatt don’t offer installation service" on Growatt USA's warranty page, captured on September 26, 2026.
Where: Freight cost, item (1); Growatt service commitment, item (4)
[4]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Growatt Off Grid Solar Inverter SPF 3000TL LVM-US / SPF 3500TL LVM-US / SPF 3500 US / SPF 5000 US User Manual (Version 1.0)Official · Growatt · Official user manual · March 2022 · PDF
    Source details
    Revision
    Version 1.0
    Revision date
    March 2022

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: PDF pages 4-6 (printed pages 4-9, installation) and 21-22 (printed pages 38-41, specifications)

    Retrieved Sep 25, 2026

    Growatt's own user manual for the SPF 3000TL LVM-US, SPF 3500TL LVM-US, SPF 3500 US and SPF 5000 US, listed on us.growatt.com Download, Manual & Quick Guide under two file names that serve identical bytes (SPF_3500-5000_US_User_Manual_EN_202203.pdf and SPF_3000-3500TL_LVM-US_User_Manual_EN_202212.pdf), captured on September 26, 2026. Image-only document with no text layer: facts were read from the rendered pages and cite the PDF page; each PDF page shows two printed pages.

    Archived copies

    Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupVersion 1.0 · 17.92 MB

    Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_3500-5000_US_User_Manual_EN_202203.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2022-03

    Embedded creation date
    Embedded modification date
    Pages
    23

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 0110c086d70ecfb28b708cb99eb9e8ae2c5854f22756808c31b0b0186471220b

    Open
  • Datasheets

  • Growatt datasheetOfficial · Growatt · Official datasheet · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF page 2

    Retrieved Sep 15, 2026

    SHA-256: a2e11928a31c836b4de2ccb34719fdf80412880c315ec4c2d06539428125a6ba

    Archived copies

    Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 4.84 MB

    Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_3500-5000_US_Datasheet_EN_202212.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: a2e11928a31c836b4de2ccb34719fdf80412880c315ec4c2d06539428125a6ba

    Open
  • Warranty

  • Growatt USA warranty page: Service terms & conditionsOfficial · Growatt · Official warranty · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: Service terms & conditions; Freight cost; Other important notice

    Retrieved Sep 25, 2026

    Growatt USA's own warranty page, captured on September 26, 2026. Its service terms cover Growatt solar inverters, storage inverters, monitoring devices and software in the United States; it defers to the warranty card and any sales contract, and it does not name individual models or battery products.

    Open
  • Other documents

  • Growatt product page: SPF 3500-5000 USOfficial · Growatt · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Product image and download list

    Retrieved Sep 24, 2026

    Growatt's own US product page for the SPF 3500-5000 US family on us.growatt.com, captured on September 25, 2026. Used here only for the product image it publishes and the documents it links; no specification is taken from the page.

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • Growatt datasheetOfficial · Growatt · Official datasheet · PDF
    Certificate & compliance claims (1)
    UL 1741Manufacturer claim · equipment listingClaimedStatus unconfirmed

    Growatt prints "UL 1741" in the Growatt SPF 3500-5000 US datasheet (EN 202405), which names SPF 3500 US, captured on September 25, 2026. This records the standard as Growatt prints it. It is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked in this pass.

    Manufacturer document

    Official datasheet: Growatt datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF page 2

    Retrieved Sep 15, 2026

    SHA-256: 18a694fa1149f3f6b681f6ca6dce3d8efd1592dc1e62cac0457330df63869b30

    Archived copies

    Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 4.92 MB

    Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_3500-5000_US_Datasheet_EN_202405.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 18a694fa1149f3f6b681f6ca6dce3d8efd1592dc1e62cac0457330df63869b30

    Open

Archived documents

Growatt datasheet

Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 4.84 MB

Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_3500-5000_US_Datasheet_EN_202212.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: a2e11928a31c836b4de2ccb34719fdf80412880c315ec4c2d06539428125a6ba

Growatt datasheet

Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 4.92 MB

Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_3500-5000_US_Datasheet_EN_202405.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 18a694fa1149f3f6b681f6ca6dce3d8efd1592dc1e62cac0457330df63869b30

Growatt Off Grid Solar Inverter SPF 3000TL LVM-US / SPF 3500TL LVM-US / SPF 3500 US / SPF 5000 US User Manual (Version 1.0)

Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupVersion 1.0 · 17.92 MB

Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_3500-5000_US_User_Manual_EN_202203.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2022-03

Embedded creation date
Embedded modification date
Pages
23

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 0110c086d70ecfb28b708cb99eb9e8ae2c5854f22756808c31b0b0186471220b

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
SPF 3500 US
  1. Observed Sep 25, 2026

    UL 1741: claimed

    Product / system scope unresolved. Growatt prints "UL 1741" in the Growatt SPF 3500-5000 US datasheet (EN 202405), which names SPF 3500 US, captured on September 25, 2026. This records the standard as Growatt prints it. It is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked in this pass.

    [1]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 85
basis: Unknown
missing:
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 22.75
unit: Unknown
shown: UL 1741
shown detail: Claimed
state: claimed
points: 10.2
ceiling: 45
weight: 45
share: 22.8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Manufacturer claim; issuer verification pending. Applies to the exact inverter.
display note: Unknown
Sources: [1]
key: warranty
label: Warranty term
value: 2
unit: Unknown
shown: 2 years
shown detail: Unknown
state: documented
points: 2.4
ceiling: 30
weight: 30
share: 8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 60
unit: Unknown
shown: 60 W
shown detail: Unknown
state: documented
points: 1.3
ceiling: 10
weight: 10
share: 13.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Printed as a bound: less than 60 W, as printed.
display note: Unknown
Sources: [2]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Growatt datasheet (Growatt · manufacturer · observed Sep 15, 2026)
  2. Growatt Off Grid Solar Inverter SPF 3000TL LVM-US / SPF 3500TL LVM-US / SPF 3500 US / SPF 5000 US User Manual (Version 1.0) (Growatt · manufacturer · Version 1.0 · observed Sep 25, 2026)
  3. Growatt datasheet (Growatt · manufacturer · observed Sep 15, 2026)
  4. Growatt USA warranty page: Service terms & conditions (Growatt · manufacturer · observed Sep 25, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details