locator: Datasheet page 2, model columns; manual page 12, MODEL row
conditions: Printed as "SC4880/4880-MPV" (the SC4880 and SC4880-MPV share a column) in Growatt's SC 4860~48120/-MPV datasheet, and as "SC4880-MPV" in the MODEL row of the -MPV table on the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1). Growatt prints no separate stock keeping number; the model designation is recorded.
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the row prints "3.2KG"; the datasheet prints 3.2 (net) and 3.9 (gross) kg.
W 295 × H 180 × D 100 mm / W 11.6 × H 7.09 × D 3.94 in converted
Printed as "295/180/100mm" (W/H/D) for the SC4860 and SC4880 columns in Growatt's SC 4860~48120/-MPV datasheet (rendered page 2) and as "295*180*100" in the SC4880-MPV column of Growatt's MPPT Solar Charge Controller user manual (Version 1.1) (rendered page 12).
Growatt documents differ. The user manual (Version 1.1) prints "USB" as the communication port; Growatt's SC 4860~48120/-MPV datasheet prints USB and BMS ports. The manual value is recorded, as the manual ranks first.
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the row prints "USB".
Where: Page 12, -MPV Specifications table, Communication Port row, SC4880-MPV column
Growatt documents differ. The user manual (Version 1.1) prints a PV operating voltage of 15~75Vdc@12V, 30~150Vdc@24V and 60~245Vdc@48V for the -MPV models; Growatt's SC 4860~48120/-MPV datasheet prints 18~50Vdc@12V, 34~100Vdc@24V and 60~200Vdc@48V for the -MPV models. The manual value is recorded, as the manual ranks first.
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the row prints "15 ~75Vdc@12V", "30~150Vdc@24V" and "60~245Vdc@48V".
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the manual is titled "MPPT Solar Charge Controller" and its table prints "Number of MPPT trackers 1" for the SC4880-MPV.
Where: Page 12, -MPV Specifications table, MODEL row, SC4880-MPV column
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1) ("80A" in the SC4880-MPV column) and the rendered page 2 of Growatt's SC 4860~48120/-MPV datasheet ("80A" in the SC4880/4880-MPV column).
Where: Manual page 12, Max. charging current row; datasheet page 2, Max.Charging Current row
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the row prints "IP20"; the datasheet prints the same.
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the row prints "250Vdc"; the datasheet prints "150/250Vdc" and says "PV input voltage up to 250VDC only for MPV series".
Where: Page 12, -MPV Specifications table, Max. PV open circuit voltage row, SC4880-MPV column
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the row prints "12V/24V/48V" for all -MPV models; the datasheet prints "Compatible Battery Nominal Voltage 12V/24V/48V".
Where: Page 12, -MPV Specifications table, Solar System Voltage row, SC4880-MPV column
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the rows print "1250W@12V", "2500W@24V" and "5000W@48V"; the datasheet prints the same for the SC4880/4880-MPV column.
Growatt documents differ. The user manual (Version 1.1) prints a self consumption of 3W for the SC4880-MPV; Growatt's SC 4860~48120/-MPV datasheet prints 2W for all models. The manual value is recorded, as the manual ranks first.
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the row prints "3W".
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the row prints "Sealed, AGM, Gel, Flooded, Lithium, User define".
Printed as "Max. PV input power 1250W@12V 2500W@24V 5000W@48V" in the SC4880-MPV column of Growatt's MPPT Solar Charge Controller user manual (read from the rendered page).
Where: Page 12 (printed page 21), -MPV Specifications table, Max. PV input power row, SC4880-MPV column (read from the rendered page)
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the row prints "-20~55℃ ( Derating from 45℃)"; output derates above 45 °C.
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the row prints "99.5%"; the datasheet prints the same.
Growatt documents differ. The user manual (Version 1.1) prints a conversion efficiency of 97%; Growatt's SC 4860~48120/-MPV datasheet prints "Max.Efficiency 97.5%". The manual value is recorded, as the manual ranks first.
Read from the rendered page 12 of Growatt's MPPT Solar Charge Controller user manual (Version 1.1): the row prints "97%".
Growatt's own MPPT Solar Charge Controller user manual (Version 1.1), hosted on Signature Solar's site (a partner store) and linked from the listing as its user manual, captured October 3, 2026. Manufacturer claims, not independent tests. The PDF has almost no text layer; every value was read from the rendered page 12 (the -MPV specification table).
Archived copies
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Growatt's own SC 4860~48120/-MPV charge controller datasheet (Growatt New Energy Technology Co., Ltd), hosted on Signature Solar's site (a partner store) and linked from the listing as its spec sheet, captured October 3, 2026. Manufacturer claims, not independent tests. The text layer loses the table's columns, so the values were read from the rendered page 2.
Archived copies
Archived copy of a document published by Growatt New Energy Technology Co., Ltd. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Growatt MPPT Solar Charge Controller User Manual, Version 1.1, SC4860 to SC48120 and SC4860-MPV to SC48120-MPV (Growatt, hosted by Signature Solar)
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Growatt SC 4860~48120/-MPV charge controller datasheet (Growatt New Energy, hosted by Signature Solar)
Archived copy of a document published by Growatt New Energy Technology Co., Ltd. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].