Charged ReviewsSaved 0Compare 0Login
Growatt
DC battery module

Growatt ALP 40.0L-E1 (AU)

Key specs

Nominal voltage51.2 V
Capacity800 Ah
Weight352 kg / 776 lb converted
Nominal energy40 kWh Check note
Maximum charge125 A

1 spec not documented yet: usable energyHelp fill in ›

All specifications

Identity

BrandGrowatt · Website
ModelALP 40.0L-E1
MarketAU
Manufacturer SKUUnknown
SKU detail
conditions: Growatt prints no SKU or part number for ALP 40.0L-E1 on its Australian product page, datasheet or manual.
Sources: No source on record
FieldValueConditionsSource
CoolingNatural cooling
Printed as "Cooling Natural cooling".
Where: Chapter 7 Technical Specifications, PDF page 38, row "Cooling", second column (ALP 40.0L-E1)
[1]
ChemistryCobalt Free Lithium Iron Phosphate (LFP)
Printed as "Cobalt Free Lithium Iron Phosphate (LFP)".
Where: Chapter 7 Technical Specifications, PDF page 38, row "Battery Type", second column (ALP 40.0L-E1)
[1]
GroundingShare a unified grounding grid with the PCS; connect PE wires to the dedicated grounding terminals with copper lugs
Printed as "The battery system shall share a unified grounding grid with PCS to ensure equipotential bonding and avoid ground loops." in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (pages 8 and 28). Section 4.5.3.6 continues: "Connect PE wires to dedicated grounding terminals marked with the "〨" symbol. Use copper lugs crimped with conductive paste to enhance contact." Section 2.2.2 adds "Ensure that the ground cable is securely connected."
Where: PDF pages 8 and 28, section 4.5.3.6 Battery System Grounding Requirements; section 2.2.2 Operation Precautions
[1]
Weight352 kg / 776 lb converted
Printed as "352kg" for ALP 40.0L-E1, the stack as one configuration; the datasheet notes the weight is without the base.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Weight", second column (ALP 40.0L-E1)
[1]
Capacity800 Ah
Printed as "800Ah/40kWh" for ALP 40.0L-E1.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Nominal Capacity/Energy", second column (ALP 40.0L-E1)
[1]
ClearancesAt least 300 mm above and on each side of a floor-mounted column; 300 mm to 800 mm between two columns
Printed as "Ground 300mm ≤d≤800mm ≥300mm ≥300mm" in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (page 15). Read with the rendered Figure 4.2, which places the ≥300 mm marks above the column and at both sides, and 300 mm ≤ d ≤ 800 mm between two columns.
Where: PDF page 15, section 4.2, Figure 4.2 Floor-mounted installation
[1]
DimensionsW 690 × H 2,360 × D 185 mm / W 27.2 × H 92.91 × D 7.28 in converted
Printed as "690*185*2360" (W/D/H, mm) for ALP 40.0L-E1. The datasheet notes that the height does not include the base.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Dimensions (W/D/H)", second column (ALP 40.0L-E1)
[1]
Mounting typeWall-mounted/Floor-mounted
Printed as "Installation Wall-mounted/Floor-mounted".
Where: Chapter 7 Technical Specifications, PDF page 38, row "Installation", second column (ALP 40.0L-E1)
[1]
Battery format
Stackable
Site classificationBased onOfficial datasheet
Details

Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.

Printed as "Easy installation with modular and stacked design" and "Floor/Wall mount". Classified as Stackable from the maker's own words for this model; the maker also prints wall/floor mounting, quoted here.

Official datasheet: ALP LV Battery System ALP 5.0L-E1 AU datasheet (Growatt, file dated 202601)

Location: ALP LV Battery System ALP 5.0L-E1 AU datasheet (Growatt, file dated 202601), page 1, feature list (image-only page, read by OCR); page 2, Installation method row (image-only page, read by OCR)

CommunicationsCAN
Printed as "Communication port CAN".
Where: Chapter 7 Technical Specifications, PDF page 38, row "Communication port", second column (ALP 40.0L-E1)
[1]
Enclosure ratingIP66
Printed as "Ingress protection IP 66".
Where: Chapter 7 Technical Specifications, PDF page 38, row "Ingress protection", second column (ALP 40.0L-E1)
[1]
Maximum charge125 A
Printed as "125A" in the ALP 40.0L-E1 column of the "Max Charging/discharging current" row, one figure for charging and discharging.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Max Charging/discharging current", second column (ALP 40.0L-E1)
[1]
Nominal voltage51.2 V
Printed as "Rated Voltage 51.2V", one value across the table.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Rated Voltage", second column (ALP 40.0L-E1)
[1]
Standard charge100 A
Printed as "100A" in the ALP 40.0L-E1 column of the "Rated Charging/discharging current" row, one figure for charging and discharging.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Rated Charging/discharging current", second column (ALP 40.0L-E1)
[1]
Usable energyUnknown
The maker's GR-UM-308-A-01, source file edition 2407 prints Rated Capacity/Energy 36.8 kWh, not Usable Energy. No usable-energy or DoD definition establishes that figure as usable. No DoD arithmetic or relabelling is used. The printed rated value remains as a dated alternative beside the nominal primary.
Where: ALP E1-AU manual PDF pages 16 and 17 / printed pages 27 to 30, exact named model column, Rated Capacity/Energy row
[2]
Cell configuration(1P16S)8P
Printed as "IFpP/51/161/11 9/[(1P16S)8P]M /-10+50/100" in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (page 38). The ALP 40.0L-E1 is 8 ALP 5.0L modules in parallel ("Number of parallel battery systems 8" in the same table); each module is "sixteen serial connection (1P16S)" (section 1.1).
Where: PDF page 38, chapter 7 Technical Specifications, Battery Designation row, ALP 40.0L-E1 column
[1]
Nominal energy40 kWh Check note
Growatt's manual editions print different rated energy. The newer GR-UM-468-A-03 manual and E1-AU datasheet print rated energy 40 kWh; the earlier GR-UM-308-A-01, source file edition 2407 prints rated energy 36.8 kWh. The nominal primary is unchanged. Both editions are retained with their scope; the earlier rated figure is not called usable.
Printed as "800Ah/40kWh" in the ALP 40.0L-E1 column of the manual's Nominal Capacity/Energy row; the Rated Capacity/Energy row prints the same figures.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Nominal Capacity/Energy", second column (ALP 40.0L-E1)
Sources
36.8 kWh

GR-UM-308-A-01, source file edition 2407; printed Rated Capacity/Energy 36.8 kWh for this exact named configuration. This is the edition's rated figure, not a usable-energy claim and not a calculated quantity.

[2]
[1]
Communication portsPCS: CAN communication; LINK-IN: CAN communication; LINK-OUT: CAN communication; USB interface
Printed as "2 PCS CAN communication" in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (page 5). Ports of each ALP 5.0L battery module's operation panel. The ALP 40.0L-E1 is built from 8 such modules.
Where: PDF page 5, section 1.2.2 Introduction to the battery operation panel
[1]
Max charge power6.2 kW
Printed as "6.2kW" maximum charging/discharging power for ALP 40.0L-E1.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Max Charging/discharging power", second column (ALP 40.0L-E1)
[1]
Maximum discharge125 A
Printed as "125A" in the ALP 40.0L-E1 column of the "Max Charging/discharging current" row, one figure for charging and discharging.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Max Charging/discharging current", second column (ALP 40.0L-E1)
[1]
Operating voltage46.4 to 57.6 V
Printed as "Operating Voltage 46.4 - 57.6V".
Where: Chapter 7 Technical Specifications, PDF page 38, row "Operating Voltage", second column (ALP 40.0L-E1)
[1]
Continuous output5 kW
Printed as "5kW" rated charging/discharging power for ALP 40.0L-E1.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Rated Charging/discharging power", second column (ALP 40.0L-E1)
[1]
Mounting orientationDo not turn the PACK upside down, and ensure that the floor is level
Printed as "Do not turn the PACK upside down, and ensure that the floor is level." in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (page 15). Figure 4.2 shows the floor-mounted column at 90° to the ground.
Where: PDF page 15, section 4.2 Basic installation requirements
[1]
Standard discharge100 A
Printed as "100A" in the ALP 40.0L-E1 column of the "Rated Charging/discharging current" row, one figure for charging and discharging.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Rated Charging/discharging current", second column (ALP 40.0L-E1)
[1]
Storage temperature-20 to 50 °C / -4 to 122 °F converted
Printed as three storage bands: -20 to 25 ℃ for 12 months, 25 to 35 ℃ for 9 months and 35 to 50 ℃ for 6 months, humidity 5% to 95% RH; the range recorded spans the three bands, each with its own time limit.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Storage conditions", second column (ALP 40.0L-E1)
[1]
Depth of discharge100 %
Printed as "DoD 100%", one value for every column; read from the rendered image-only page.
Where: Page 2, row "DoD"
[3]
Max discharge power6.2 kW
Printed as "6.2kW" maximum charging/discharging power for ALP 40.0L-E1.
Where: Chapter 7 Technical Specifications, PDF page 38, row "Max Charging/discharging power", second column (ALP 40.0L-E1)
[1]
Inverter communicationsCAN
Printed as "The whole battery system communicates to Power Conversion System (PCS) via CAN." in the Growatt User Manual for the ALP 5.0L-E1 Battery System (GR-UM-468-A-03, Australian site, 202609) (page 6). The PCS port pin definition (section 4.5.3.1) lists CAN_H and CAN_L.
Where: PDF page 6, section 1.3 Working Principle and Function
[1]
Operating temperature-10 to 50 °C / 14 to 122 °F converted Check note
Two editions of Growatt's AU manual print different operating temperature ranges. The recorded GR-UM-468-A-03 edition (202609) of the ALP 5.0L-E1 AU user manual prints -10°C~50°C; the earlier GR-UM-308-A-01 edition (202407) prints 0°C~50°C. The newer edition is shown first.
Printed as "Operative temperature range -10°C~50°C".
Where: Chapter 7 Technical Specifications, PDF page 38, row "Operative temperature range", second column (ALP 40.0L-E1)
Sources
0 to 50 °C

Printed as "Operative temperature range 0°C~50°C" in the 202407 edition; its label also prints an operating ambient temperature of 0°C ~ +50°C.

[2]
[1]
Recommended temperature15 to 30 °C / 59 to 86 °F converted
Printed as "Recommended operating temperature 15°C~30°C".
Where: Chapter 7 Technical Specifications, PDF page 38, row "Recommended operating temperature", second column (ALP 40.0L-E1)
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Basic specs
40 kWhValue needs confirmation: Growatt's manual editions print different rated energyDischarge 100 A standardCharge 100 A standard
$ / rated kWh
Unavailable
Warranty
10 yearsSee terms
Lifetime production
Not published
Size
301.25 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 690 × H: 2,360 × D: 185 mm / W: 27.2 × H: 92.91 × D: 7.28 in352 kg / 776 lb0.13 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)

Evidence score

13/100Missing details20% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.

48 V · Stackable · Rated capacity

The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

Warranty term10 years13.33 / 20

10 years · 20% weight

10 of 15 years, the best documented for a home storage battery (printed by the maker): Blue Ion LX battery energy storage system (125 kW / 128 kWh)

Printed as a 10-year warranty in the datasheet table ("Warranty 10 years" for E1; "Warranty: 10 years Yes" for E2); read from the rendered image-only page. The datasheet does not state what the term covers or its conditions.

66.7 / 100 × 20 = 13.33 points.

[3]

Lifetime / capacityResearch pending0 / 20

No qualifying figure · 20% weight

Not published. No lifetime-production bonus.

Not documented. Undisclosed data scores 0.

[1]

Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL 1973manufacturer claimpresent at observation[1]
Scope
cell
Covered models
ALP 40.0L-E1
Limitations
A manufacturer claim at cell level, not a listing or certificate. Printed as "Cell safety certification IEC62619/UL1973" (row 21) in chapter 7, Technical Specifications, of Growatt's ALP 5.0L-E1 Battery System User Manual (GR-UM-468-A-03, file dated 202609, au.growatt.com), page 35 (PDF page 38), in the table whose Battery Model columns are ALP 35.0L-E1 and ALP 40.0L-E1; the row spans both columns. The table's separate PACK certification row (row 22) does not list UL 1973. Captured September 29, 2026. Cell scope does not certify the assembled battery. No issuer, certificate or report number is printed; the issuer's record was not checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 29, 2026
Source
[1]

Warranty

FieldValueConditionsSource
Warranty term10 years
Printed as a 10-year warranty in the datasheet table ("Warranty 10 years" for E1; "Warranty: 10 years Yes" for E2); read from the rendered image-only page. The datasheet does not state what the term covers or its conditions.
Where: Page 2, row "Warranty"
[3]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • User Manual, ALP 5.0L-E1-AU Battery System (Growatt, GR-UM-308-A-01, 202407 edition) (Growatt's own file, copy hosted by distributor www.gosolar.com.au)Shenzhen Growatt New Energy Co., Ltd. · Distributor user manual · PDF
    Source details
    Revision
    GR-UM-308-A-01 (202407)
    Revision date
    Not stated

    Copy hosted by www.gosolar.com.au of Growatt's file https://en.growatt.com/upload/file/ALP_5.0L-E1-AU_User_Manual_EN.pdf.

    Location: Fig 2.2 label; chapter 7 Technical Specifications

    Retrieved Sep 29, 2026

    Growatt's own document, the file Growatt publishes as https://en.growatt.com/upload/file/ALP_5.0L-E1-AU_User_Manual_EN.pdf, in the copy hosted by the distributor www.gosolar.com.au and fetched there on September 29, 2026 after www.gosolar.com.au's robots.txt allowed the path; the bytes are Growatt's file (it prints Growatt's name and the model), not a distributor document. Growatt's own copy sits under /upload/, which Growatt's robots.txt disallows, so it was never requested. An earlier edition of the Australian ALP 5.0L-E1 manual than the GR-UM-468-A-03 edition (202609) the records already cite. Its chapter 7 tables print ALP 5.0L-E1 to ALP 40.0L-E1 (it does not cover 45.0L or 50.0L), and its label (Fig 2.2) prints each system model with its rated current, capacity and energy. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupGR-UM-308-A-01 (202407) · 18.74 MB

    Archived copy, unaltered, kept as a record of what Shenzhen Growatt New Energy Co., Ltd. published. Original address: https://www.gosolar.com.au/wp-content/uploads/2024/04/ALP_5.0L_E1_AU_User_Manual_EN.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    19

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 26691c32cc31d162e649e628e6cd0482b9eacbc965103ed4508e654d4c254771

    Open
  • Other documents

  • ALP LV Battery (ALP 5.0L-E1) product page, au.growatt.com (September 29, 2026 capture)Official · Shenzhen Growatt New Energy Co., Ltd. · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.

    Location: Page text and download list

    Retrieved Sep 28, 2026

    Growatt's Australian product page for the ALP LV Battery (ALP 5.0L-E1), captured September 29, 2026. Cited for the product name, the market it is published for and the links to the AU datasheet and the user manual. Its feature list is marketing text, not a specification table. Manufacturer claims, not independently verified.

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • User Manual, ALP 5.0L-E1 Battery System (Growatt, GR-UM-468-A-03, file dated 202609)Official · Shenzhen Growatt New Energy Co., Ltd. · Official user manual · PDF
    Certificate & compliance claims (1)
    UL 1973Manufacturer claim · cellClaimedListed when checked

    A manufacturer claim at cell level, not a listing or certificate. Printed as "Cell safety certification IEC62619/UL1973" (row 21) in chapter 7, Technical Specifications, of Growatt's ALP 5.0L-E1 Battery System User Manual (GR-UM-468-A-03, file dated 202609, au.growatt.com), page 35 (PDF page 38), in the table whose Battery Model columns are ALP 35.0L-E1 and ALP 40.0L-E1; the row spans both columns. The table's separate PACK certification row (row 22) does not list UL 1973. Captured September 29, 2026. Cell scope does not certify the assembled battery. No issuer, certificate or report number is printed; the issuer's record was not checked.

    Manufacturer document

    Official user manual: User Manual, ALP 5.0L-E1 Battery System (Growatt, GR-UM-468-A-03, file dated 202609)
    Source details
    Revision
    GR-UM-468-A-03
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.

    Location: Chapter 7, Technical Specifications (PDF pages 35 to 39)

    Retrieved Sep 28, 2026

    Growatt's English user manual for the ALP 5.0L-E1 battery system, linked from the Australian ALP 5.0L-E1 page and served from au.growatt.com, captured September 29, 2026. Chapter 7 prints one technical table per pair of configurations, from one pack (ALP 5.0L-E1) to ten packs (ALP 50.0L-E1). The primary source for these records. Manufacturer claims, not independently verified.

    Archived copies

    Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupGR-UM-468-A-03 · 13.02 MB

    Archived copy, unaltered, kept as a record of what Shenzhen Growatt New Energy Co., Ltd. published. Original address: https://au.growatt.com/upload/file/ALP_5.0L-E1_User_Manual_EN_202609.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    44

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: f9647014a686dc9ce4d6b2c55d19ec6cec1a4a209b4eaf09a623a45beb55eee6

    Open

Archived documents

User Manual, ALP 5.0L-E1 Battery System (Growatt, GR-UM-468-A-03, file dated 202609)

Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupGR-UM-468-A-03 · 13.02 MB

Archived copy, unaltered, kept as a record of what Shenzhen Growatt New Energy Co., Ltd. published. Original address: https://au.growatt.com/upload/file/ALP_5.0L-E1_User_Manual_EN_202609.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
44

Embedded dates are file metadata, not independent proof of publication.

SHA-256: f9647014a686dc9ce4d6b2c55d19ec6cec1a4a209b4eaf09a623a45beb55eee6

ALP LV Battery System ALP 5.0L-E1 AU datasheet (Growatt, file dated 202601)

Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupAU 202601 · 1.90 MB

Archived copy, unaltered, kept as a record of what Shenzhen Growatt New Energy Co., Ltd. published. Original address: https://au.growatt.com/upload/file/ALP_LV_Battery_System_ALP_5.0L-E1_AU_202601.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 66d92d37297b1d781e3597fc17c6b70c9a601b0f07b05e84748521afaeb31a17

User Manual, ALP 5.0L-E1-AU Battery System (Growatt, GR-UM-308-A-01, 202407 edition) (Growatt's own file, copy hosted by distributor www.gosolar.com.au)

Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupGR-UM-308-A-01 (202407) · 18.74 MB

Archived copy, unaltered, kept as a record of what Shenzhen Growatt New Energy Co., Ltd. published. Original address: https://www.gosolar.com.au/wp-content/uploads/2024/04/ALP_5.0L_E1_AU_User_Manual_EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
19

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 26691c32cc31d162e649e628e6cd0482b9eacbc965103ed4508e654d4c254771

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
ALP 40.0L-E1

Manufacturer SKU unknown · AU market

  1. Observed Sep 29, 2026

    UL 1973: claimed

    Cell / component only. A manufacturer claim at cell level, not a listing or certificate. Printed as "Cell safety certification IEC62619/UL1973" (row 21) in chapter 7, Technical Specifications, of Growatt's ALP 5.0L-E1 Battery System User Manual (GR-UM-468-A-03, file dated 202609, au.growatt.com), page 35 (PDF page 38), in the table whose Battery Model columns are ALP 35.0L-E1 and ALP 40.0L-E1; the row spans both columns. The table's separate PACK certification row (row 22) does not list UL 1973. Captured September 29, 2026. Cell scope does not certify the assembled battery. No issuer, certificate or report number is printed; the issuer's record was not checked.

    [1]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Lifetime / capacity evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: UL 1973
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: CEC; UL 9540; UL 1973.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: 10
unit: years
shown: 10 years
shown detail: Unknown
state: documented
points: 13.33
ceiling: 20
weight: 20
share: 66.7
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [3]
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: no
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not published. No lifetime-production bonus.
display note: Unknown
Sources: [1]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. User Manual, ALP 5.0L-E1 Battery System (Growatt, GR-UM-468-A-03, file dated 202609) (Shenzhen Growatt New Energy Co., Ltd. · manufacturer · GR-UM-468-A-03 · observed Sep 28, 2026)
  2. User Manual, ALP 5.0L-E1-AU Battery System (Growatt, GR-UM-308-A-01, 202407 edition) (Growatt's own file, copy hosted by distributor www.gosolar.com.au) (Shenzhen Growatt New Energy Co., Ltd. · manufacturer document distributor hosted · GR-UM-308-A-01 (202407) · observed Sep 29, 2026)
  3. ALP LV Battery System ALP 5.0L-E1 AU datasheet (Growatt, file dated 202601) (Shenzhen Growatt New Energy Co., Ltd. · manufacturer · AU 202601 · observed Sep 28, 2026)