One battery module unit, printed as "94.8 lb / 43 kg". A complete system weighs 89.60 kg for the cabinet plus 13.30 kg for the control unit plus 43 kg per module.
Printed as "≥ 6000 cycles" in Pytes HV48100 datasheet (January 2026 upload), Page 2, HV48100 System table, Cycle Life row and footnote 1. Revised on 1 October 2026: The datasheet prints the cycle life as at least 6000 cycles, and the HV48100 manual also prints it as ≥6000 cycles.
Where: Page 2, HV48100 System table, Cycle Life row and footnote 1
W 484 × H 140 × D 530 mm / W 19.1 × H 5.51 × D 20.9 in converted
One battery module unit, printed as "19.06 x 20.87 x 5.51 inch / 484 x 530 x 140 mm" in Pytes's own W x D x H order. The assembled cabinet is separately printed as 500 x 640 x 1555 mm and is not recorded here.
Where: Page 2, HV48100 BMU table, Dimensions (W x D x H) row
Module-level ports. The assembled system adds dry contact and WiFi through the battery control unit, as the system table prints. Protocol availability alone does not establish a listed inverter pairing.
Where: Page 2, HV48100 BMU table, Communication row
System rating. IP20 is an indoor rating: it protects against fingers and solid objects of 12.5 mm or more and against no water at all. The sheet prints no separate rating for the module.
Where: Page 2, HV48100 System table, Ingress Protection row
Printed as "5~15", with the footnote "'n' represent the quantity of BMU, from 5 to 15 pcs". The modules are stacked in series: five is the published minimum, fifteen the maximum.
Where: Page 2, HV48100 System table, BMU Qty. (Variable) row and the footnote on "n"
Printed as "Rated Charge/Discharge Current 50A Maximum Charge/Discharge Current 50A" in the Pytes HV48100 User Manual (V1.2), battery module unit label data, captured on September 26, 2026.
Printed system nominal-voltage bounds for five to fifteen modules on a control unit. BMU-5 prints 256 V and BMU-15 768 V; all eleven discrete rows are printed. This is not the one-module 51.2 V nominal rating and is not derived by multiplying modules.
Where: HV48100 manual V1.2 p17, Battery Control Unit label, Nominal Voltage column, BMU-5 through BMU-15 rows
High-voltage system module; assembled system nominal voltage 256 to 768 V with BCU.
Nominal voltage of one battery module unit; the sheet gives its operating range as 47.5 V to 57.6 V. The manual V1.2 p17 separately lists HV48100 BMU-5 through BMU-15 complete-system nominal voltages; this 51.2 V value belongs to one BMU.
Where: Page 2, HV48100 BMU table, Nominal Voltage row
Printed as "Rated Charge/Discharge Current 50A Maximum Charge/Discharge Current 50A" in the Pytes HV48100 User Manual (V1.2), battery module unit label data, captured on September 26, 2026.
Printed as "Charge: 32 °F ~ 113 °F / 0 °C ~ 45 °C". The sheet publishes no heating film for this product, so nothing extends the cold end of that range.
Where: Page 2, HV48100 System table, Operating Temperature row
HV48100 BCU; HV48100 BMU-5 through HV48100 BMU-15 system configurations
The manual names HV48100 BCU and the five-to-fifteen BMU system configurations. Its BMU terminal description says "To connect with Battery in series." This does not claim standalone compatibility with a 48 V inverter. The manual lists "Battery Box or Bracket(Optional)" for its system labels; no mandatory cabinet requirement is inferred.
Where: HV48100 manual V1.2 pp16–18, Main Control Unit and Battery Control Unit label
Printed in the storage requirements of the Pytes HV48100 User Manual (V1.2), captured on September 26, 2026: -20 to 50 °C for storage within one month, -10 to 40 °C for one to three months.
Printed as a range of "25.6 kWh ~ 76.8 kWh" for five to fifteen modules on one control unit; the upper figure is recorded. The sheet publishes no limit on the number of systems that may be paralleled.
Where: Page 2, HV48100 System table, Nominal System Energy row
35.91 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 484 × H: 140 × D: 530 mm / W: 19.1 × H: 5.51 × D: 20.9 in43 kg / 95 lb0.14 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
31/100Missing details85% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
High voltage · Format not recorded · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
CertificatesUL 9540 Ed.3 (2023) · UL 9540A +1Claimed13.78 / 45
30.63 evidence points · 45% weight
UL 9540: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: CEC; UL 9540; UL 1973.
Printed as "10 Years" with footnote 2 reading "10 years or 6000 cycles (whichever comes first)". No warranty contract, coverage list, remedy or exclusion set was read; the datasheet line is the whole of the published term.
Research pending, 0 points: Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1973manufacturer claimpresent at observation[1]
Scope
battery module
Covered models
HV48100
Limitations
The HV48100 datasheet names UL 1973 in its Certifications row without a certificate number, issuer or listing file, and without saying whether the claim is for the battery module unit or the assembled system. No issuer record was read.
UL 9540 Ed.3 (2023)manufacturer claimpresent at observation[1]
Scope
system
Covered models
HV48100
Limitations
The HV48100 datasheet prints "UL 9540 Ed.3(2023), UL 9540A, UL 1973, CEC, SGIP" against a Certifications row. No certificate number, issuer, listing file or certification body is named, and no issuer record was read. Which system configuration -- five modules or fifteen -- the claim covers is not stated.
UL 9540Amanufacturer claimpresent at observation[1]
Scope
system
Covered models
HV48100
Limitations
The HV48100 datasheet names UL 9540A in its Certifications row without an edition, a test report, a laboratory or a test level. UL 9540A is a fire-propagation test method rather than a listing, so nothing about installation separation distances or code acceptance follows from it here.
The term ends at ten years or 6000 cycles, whichever comes first. No throughput figure and no end-of-life retention figure is published for the warranty itself.
Printed as "10 Years" with footnote 2 reading "10 years or 6000 cycles (whichever comes first)". No warranty contract, coverage list, remedy or exclusion set was read; the datasheet line is the whole of the published term.
Where: Page 2, HV48100 System table, Warranty row and footnote 2
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: Specifications, storage and cable sections
Retrieved Sep 25, 2026
Pytes' own HV48100 user manual, listed in the Pytes Download Center for this model and captured on September 26, 2026. Manufacturer claims, not a certificate.
Archived copies
Archived copy of a document published by Pytes. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
UL 9540 Ed.3 (2023)Manufacturer claim · systemClaimedListed when checked
The HV48100 datasheet prints "UL 9540 Ed.3(2023), UL 9540A, UL 1973, CEC, SGIP" against a Certifications row. No certificate number, issuer, listing file or certification body is named, and no issuer record was read. Which system configuration -- five modules or fifteen -- the claim covers is not stated.
UL 9540AManufacturer claim · systemClaimedListed when checked
The HV48100 datasheet names UL 9540A in its Certifications row without an edition, a test report, a laboratory or a test level. UL 9540A is a fire-propagation test method rather than a listing, so nothing about installation separation distances or code acceptance follows from it here.
UL 1973Manufacturer claim · battery moduleClaimedListed when checked
The HV48100 datasheet names UL 1973 in its Certifications row without a certificate number, issuer or listing file, and without saying whether the claim is for the battery module unit or the assembled system. No issuer record was read.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-22.
Location: Page 2, "HV48100 Specifications": HV48100 BMU, HV48100 BCU and HV48100 System tables with footnotes 1 and 2
Retrieved Sep 21, 2026
The two-page HV48100 specification sheet Pytes serves from the Datasheet link of its own HV48100 product page, captured byte for byte on September 22, 2026. It establishes the published figures for the battery module unit (51.2 V, 100 Ah, 5.12 kWh, 50 A continuous charge and discharge, LFP, CAN and RS485, 484 x 530 x 140 mm, 43 kg), for the battery control unit (200-870 V working voltage, 7.56 W self-consumption, 484 x 510 x 140 mm, 13.3 kg) and for the assembled system (256-768 V, 25.6-76.8 kWh, five to fifteen modules, IP20, 0-45 °C charging, -10-50 °C discharging, 6000 cycles, ten-year warranty). It carries no revision number and no issue date beyond the upload path, and it names UL 9540 Ed.3, UL 9540A, UL 1973, CEC and SGIP as certifications without a certificate number or an issuer record, so no listing is established by it.
Archived copies
Archived copy of a document published by Pytes. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-22.
Location: Title block "HV48100"; Datasheet link; product image carousel with alt text "HV48100"
Retrieved Sep 21, 2026
Pytes's own HV48100 product page, captured byte for byte on September 22, 2026. It establishes what Pytes published for this model on the access date: the marketing description, the feature strip, the case studies and the Datasheet link that serves the January 2026 specification sheet archived alongside it, together with the five product photographs the page publishes with alt text "HV48100". The page prints no specification table, no price and no warranty text, so every figure recorded for this model comes from the datasheet rather than from here. The page is read here as photograph evidence and as proof that Pytes still lists the model.
Archived copy of a document published by Pytes. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Pytes. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
HV48100
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 85
basis: nominal
missing:
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 30.625
unit: evidence points
shown: UL 9540 Ed.3 (2023) · UL 9540A +1
shown detail: Claimed
state: claimed
points: 13.78
ceiling: 45
weight: 45
share: 30.6
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: UL 9540: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: CEC; UL 9540; UL 1973.