50% capacity after 1328 cycles
1 of 3 batteries in my system has cells with low capacity, as low as 20% SOH vs cell average 65% All 3 are the same US2000C in the same system, waiting to hear back from Pylontech for RMA
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Cover figure of Pylontech's own US2000C Operation Manual (5PMPA08-00220), a front view of the module whose panel prints "US2000C". Figure from the manufacturer's document, page 1.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Chemistry | LiFePO4 | Printed as "Cathode material is made from LiFePO4". Where: Section 3.1 Features, item 8 | [1] |
| Weight | 22.5 kg / 49.6 lb converted | As printed. Where: Section 3.2 Specifications, Weight (Kg) | [1] |
| Cycle life | 8,000 cycles >8,000 as printed | Printed as ">8,000 25℃", with the note that cycle life is defined under specific operating conditions available from Pylontech's service team. Where: Section 3.2 Specifications, Cycle Life (cycle) | [1] |
| Dimensions | W 410 × H 89 × L 440 mm / W 16.1 × H 3.5 × L 17.3 in converted | Printed as "440*410*89" without axis labels; recorded in printed order. Where: Section 3.2 Specifications, Dimension (mm) | [1] |
| Mounting type | standard of 19-inch embedded designed module | Printed as "Small size and light weight, standard of 19-inch embedded designed module is comfortable for installation and maintenance" in the Pylontech US2000C installation manual, section 3.1 Features, item 14. Where: Section 3.1 Features, item 14 | [1] |
| Battery format | Server rack DetailsCharged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim. The site's classification of the printed wording "standard of 19-inch embedded designed module" (features) as the "Server rack" battery format. This is the catalog's own format grouping, not a manufacturer term; the printed wording is kept in its own field where the catalog has one. Revised on 30 September 2026: The recorded value "19-inch rack module" was printed text, not one of the site's battery format codes, so the grouping could not read it. It is replaced by the matching code; the printed wording stays in the record history and, where a field exists for it, in that field. Official instruction manual: Pylontech US2000C Operation Manual, V1.0 (5PMPA08-00220)Location: Section 3.1 Features, item 14 | ||
| Communications | RS485; CAN | As printed. Where: Section 3.2 Specifications, Communication | [1] |
| Enclosure rating | IP20 | As printed. Where: Section 3.2 Specifications, IP rating of enclosure | [1] |
| Peak discharge | 200 A | Upper end of the printed range "90~200@15sec". The manual also prints "Max. Charge/Discharge Current (A) 50-89@60sec". Where: Section 3.2 Specifications, Peak Charge/Discharge Current (A) | [1] |
| Nominal voltage | 48 V | As printed. Where: Section 3.2 Specifications, Nominal Voltage (V) | [1] |
| Usable energy | 2.28 kWhConverted: 2280 Wh / 1000 Wh per kWh | Printed as "Usable Capacity (Wh) 2280", with a 95% depth of discharge. Where: Section 3.2 Specifications, Usable Capacity (Wh) SourcesConverted: 2280 Wh / 1000 Wh per kWh | [1] |
| Max parallel units | 16 count | Printed as the maximum in one battery group. Where: Section 3.2 Specifications, Configuration | [1] |
| Nominal energy | 2.4 kWhConverted: 2400 Wh / 1000 Wh per kWh | Printed as "Nominal Capacity (Wh) 2400". Where: Section 3.2 Specifications, Nominal Capacity (Wh) SourcesConverted: 2400 Wh / 1000 Wh per kWh | [1] |
| Operating voltage | 44.5 to 53.5 V | Printed as the discharge voltage range "44.5 ~ 53.5". Where: Section 3.2 Specifications, Discharge Voltage (V) | [1] |
| Certification claims | IEC62619; IEC63056; UL1642; IEC61000-6-2; IEC61000-6-3; UN38.3 | Manufacturer claim recorded as printed ("IEC62619, IEC63056 UL1642, ..."; the manual prints no comma between IEC63056 and UL1642). No certificate was read. Where: Section 3.2 Specifications, Reference to standards | [1] |
| Charge temperature | 0 to 50 °C / 32 to 122 °F converted | Printed as "0~50 Charge"; the row label reads "Working Temperature (50℃)" as printed. Where: Section 3.2 Specifications, Working Temperature | [1] |
| Recommended charge | 25 A | Printed as one figure for charge and discharge. Where: Section 3.2 Specifications, Recommend Charge/Discharge Current (A) | [1] |
| Storage temperature | -20 to 60 °C / -4 to 140 °F converted | Printed as "Shelf Temperature (50℃) -20~60"; the unit label is read as degrees Celsius. Where: Section 3.2 Specifications, Shelf Temperature | [1] |
| Depth of discharge | 95 % | As printed. Where: Section 3.2 Specifications, Depth of discharge (%) | [1] |
| Discharge temperature | -10 to 50 °C / 14 to 122 °F converted | Printed as "-10~50 Discharge"; the row label reads "Working Temperature (50℃)" as printed. Where: Section 3.2 Specifications, Working Temperature | [1] |
| Other compliance claims | TÜV / CE / UN38.3 | As printed in the manual's "Certifications" row. Where: Section 3.2 Specifications, Certifications | [1] |
| Recommended charge voltage | 52.5 to 53.5 V | Printed as the charge voltage range "52.5 ~ 53.5". Where: Section 3.2 Specifications, Charge Voltage (V) | [1] |
1 of 3 batteries in my system has cells with low capacity, as low as 20% SOH vs cell average 65% All 3 are the same US2000C in the same system, waiting to hear back from Pylontech for RMA
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
48 V · Server rack · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
7 years · 20% weight
7 of 20 years, the best documented for a small DC battery (printed by the maker): Bioenno Power 6V 3Ah LiFePO4 Battery (PVC, BLF-0603W)
Printed as "Seven (7) years" from the earlier of installation or six months after manufacture. The US series warranty UL22WUSS100302 names US2000, US3000, US2000C, US3000C, US5000 and US5000-B as the Product. The closing note extends the period to ten years with product registration (see extended warranty).
35 / 100 × 20 = 7 points.
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
20 × 0.2 = 4 points.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Territory | United States and Canada | Printed as "Territory means United States and Canada." Coverage requires purchase from Pylontech or an authorized reseller in the territory and installation in the territory in an indoor environment. Where: Section 8, Definitions, Territory | [2] |
| Start basis | earlier of installation date or six months after manufacture | As printed in section 2. Where: Section 2, Product Warranty | [2] |
| Retention | 70 % at least 70% as printed | Printed as "at least 70% of the Nominal Energy during the Warranty Period" for the seven-year term; 60% at the end of a registered ten-year term. Capacity tests follow the conditions in section 5 (single module, 25 °C, 0.2C). Where: Section 8, Definitions, Minimum Capacity | [2] |
| Warranty term | 7 years | Printed as "Seven (7) years" from the earlier of installation or six months after manufacture. The US series warranty UL22WUSS100302 names US2000, US3000, US2000C, US3000C, US5000 and US5000-B as the Product. The closing note extends the period to ten years with product registration (see extended warranty). Where: Section 2, Product Warranty | [2] |
| Extended warranty | 10 years total with product registration on the Pylontech website | Printed as "Warranty period could be extended to Ten (10) years FOR FREE by successfully register your product on Pylontech website", with the minimum remaining capacity then not less than 60% of the nominal capacity at the end of the warranty period. Where: Closing note | [2] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Printed as "IEC62619" in the "Reference standards" row of Pylontech's US2000C operation manual ("Reference to standards IEC62619, IEC63056 UL1642, IEC61000-6-2, IEC61000-6-3, UN38.3"). Recorded exactly as printed. The manual names no certification body, certificate number or scope for this standard, no certificate for it was read, and no issuer record was checked.
Manufacturer document
Official instruction manual: Pylontech US2000C Operation Manual, V1.0 (5PMPA08-00220)Printed as "IEC63056" in the "Reference standards" row of Pylontech's US2000C operation manual ("Reference to standards IEC62619, IEC63056 UL1642, IEC61000-6-2, IEC61000-6-3, UN38.3"). Recorded exactly as printed. The manual names no certification body, certificate number or scope for this standard, no certificate for it was read, and no issuer record was checked.
Manufacturer document
Official instruction manual: Pylontech US2000C Operation Manual, V1.0 (5PMPA08-00220)Printed as "UL1642" in the "Reference standards" row of Pylontech's US2000C operation manual ("Reference to standards IEC62619, IEC63056 UL1642, IEC61000-6-2, IEC61000-6-3, UN38.3"). Recorded exactly as printed. The manual names no certification body, certificate number or scope for this standard, no certificate for it was read, and no issuer record was checked.
Manufacturer document
Official instruction manual: Pylontech US2000C Operation Manual, V1.0 (5PMPA08-00220)Printed as "IEC61000-6-2" in the "Reference standards" row of Pylontech's US2000C operation manual ("Reference to standards IEC62619, IEC63056 UL1642, IEC61000-6-2, IEC61000-6-3, UN38.3"). Recorded exactly as printed. The manual names no certification body, certificate number or scope for this standard, no certificate for it was read, and no issuer record was checked.
Manufacturer document
Official instruction manual: Pylontech US2000C Operation Manual, V1.0 (5PMPA08-00220)Printed as "IEC61000-6-3" in the "Reference standards" row of Pylontech's US2000C operation manual ("Reference to standards IEC62619, IEC63056 UL1642, IEC61000-6-2, IEC61000-6-3, UN38.3"). Recorded exactly as printed. The manual names no certification body, certificate number or scope for this standard, no certificate for it was read, and no issuer record was checked.
Manufacturer document
Official instruction manual: Pylontech US2000C Operation Manual, V1.0 (5PMPA08-00220)Printed as "UN38.3" in the "Reference standards" row of Pylontech's US2000C operation manual ("Reference to standards IEC62619, IEC63056 UL1642, IEC61000-6-2, IEC61000-6-3, UN38.3"). Recorded exactly as printed. The manual names no certification body, certificate number or scope for this standard, no certificate for it was read, and no issuer record was checked.
Manufacturer document
Official instruction manual: Pylontech US2000C Operation Manual, V1.0 (5PMPA08-00220)Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Section 3.2 Specifications
Retrieved Sep 24, 2026
Pylontech's 36-page US2000C operation manual, Version V1.0, document 5PMPA08-00220, listed in its download center as "RESS-Installation Manual-US2000C-5PMPA08-00220-V1.0", captured on September 25, 2026. It prints no date, and its temperature rows carry a stray "(50℃)" in the label. The file is served from Pylontech's Alibaba Cloud storage bucket (global-site.oss-eu-central-1.aliyuncs.com), the address Pylontech's own site opens when a visitor previews the document in its download center or product page.
Archived copy of a document published by Pylon Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Pylon Technologies Co., Ltd. published. Original address: https://global-site.oss-eu-central-1.aliyuncs.com/upload/2024/09/25/RESS-Installation%20Manual-US2000C-5PMPA08-00220-V1.0_20240925123746A052.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: a1e1e4560a1b821f0c89455422a9eace83558418926e35b843a4335b6eb212a9
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Sections 2, 4, 5 and 8 and closing note
Retrieved Sep 24, 2026
Pylontech's consumer warranty for the US series, document UL22WUSS100302, listed in its download center under Product warranty as "Pylontech product warranty-US serie V1.2 UL22WUSS100302 UL", captured on September 25, 2026. It names the covered products as US2000, US3000, US2000C, US3000C, US5000 and US5000-B and the territory as the United States and Canada. It prints no issue date. The file is served from Pylontech's Alibaba Cloud storage bucket (global-site.oss-eu-central-1.aliyuncs.com), the address Pylontech's own site opens when a visitor previews the document in its download center or product page.
Archived copy of a document published by Pylon Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Pylon Technologies Co., Ltd. published. Original address: https://global-site.oss-eu-central-1.aliyuncs.com/upload/2024/11/01/Pylontech%20product%20warranty-US%20serie%20V1.2%20%20UL22WUSS100302%20UL_20241101150134A200.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 6833cd1da374fa081df674b9dd2a5e9e7c01313bd1b5f2e2392490babdce4361
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Pylon Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Pylon Technologies Co., Ltd. published. Original address: https://global-site.oss-eu-central-1.aliyuncs.com/upload/2024/09/25/RESS-Installation%20Manual-US2000C-5PMPA08-00220-V1.0_20240925123746A052.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: a1e1e4560a1b821f0c89455422a9eace83558418926e35b843a4335b6eb212a9
Archived copy of a document published by Pylon Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Pylon Technologies Co., Ltd. published. Original address: https://global-site.oss-eu-central-1.aliyuncs.com/upload/2024/11/01/Pylontech%20product%20warranty-US%20serie%20V1.2%20%20UL22WUSS100302%20UL_20241101150134A200.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 6833cd1da374fa081df674b9dd2a5e9e7c01313bd1b5f2e2392490babdce4361
No sourced accessories or replacement parts listed yet.
Manufacturer SKU US2000C · US market
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: 0.21-personal documented pct: 40 basis: nominal missing: Certificates evidence needed Warranty energy disclosure evidence needed Cell model disclosure evidence needed criteria: key: certificateEvidence label: Certificates value: 0 unit: evidence points shown: IEC62619 · IEC63056 +4 shown detail: Research pending state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: CEC; UL 9540; UL 1973. display note: Unknown Sources: No source on record key: years label: Warranty term value: 7 unit: years shown: 7 years shown detail: Unknown state: documented points: 7 ceiling: 20 weight: 20 share: 35 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [2] key: throughputEvidence label: Warranty energy disclosure value: 0 unit: evidence points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment. display note: Unknown Sources: No source on record key: lifetime label: Lifetime / capacity value: Unknown unit: MWh/kWh shown: 8,000 cycles shown detail: Unknown state: documented points: 4 ceiling: 20 weight: 20 share: Unknown covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh. display note: Unknown Sources: [1] key: cellDisclosure label: Cell model disclosure value: 0 unit: disclosure points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 5 weight: 5 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model. display note: Unknown Sources: No source on record | ||
Links to DIY Solar Forum threads. The title is the forum's own words. It is a member's experience, not a Charged test, not a verified fault rate, and not a statement by the maker.
Sign in to report an error on this page
* Missing details