Printed as "Cooling Natural cooling" in the Growatt APX 5.0~30.0P-S0-US User Manual (GR-UM-340-A-02, 2024-11), section 7.2, captured on September 26, 2026.
Where: PDF pages 60-61, section 7.2 APX 5.0P-B1-US (Battery Module)
Printed as "8 Battery Type Cobalt Free Lithium Iron Phosphate (LFP)" in the Growatt APX HV Battery System US user manual (EN, 2024-11) (page 60, 7.2 APX 5.0P-B1-US (Battery Module), row 8).
Ensure the protective earth cable is securely connected; yellow and green multi-core copper cable, AWG10 to AWG8
Printed as "Ensure that the protective earth cable is securely connected."; "Grounding cable One yellow and green multi-core copper cable AWG10≤Wire diameter≤AWG8" in the Growatt APX HV Battery System US user manual (EN, 2024-11) (pages 13, 31, 2.2.2 Operation Precautions; 4.4.1 Connecting to the inverter, cable table).
Where: PDF pages 13, 31, 2.2.2 Operation Precautions; 4.4.1 Connecting to the inverter, cable table
Printed as "IFpP/51/161/119/[1P16S]M/-10+50/90 Formula for calculating the rated capacity: Rated capacity of the measured module: 100 Ah N (Number of modules connected in Parallel): 1~6" in the Growatt APX HV Battery System US User Manual (EN, 202411), 7.2 APX 5.0P-B1-US (Battery Module), captured September 27, 2026. Recorded exactly as printed; unlike the APX H-S1 family's formula, no cell manufacturer name is printed here.
Where: Manual, 7.2 APX 5.0P-B1-US (Battery Module), rated-capacity formula
W 690 × H 295 × D 185 mm / W 27.2 × H 11.6 × D 7.28 in converted
Growatt publishes "690/185/295mm" in that row for APX 5.0P-B1-US, a row its datasheet states once across every model column of this table. The datasheet prints this row as width / depth / height.
Where: APX HV Battery System US datasheet (EN, 2025-05), page 2, row "Dimensions (W/D/H)", column "APX 5.0P-B1-US"
Printed as "Installation /Wall-mounted installation Floor-mounted installation" in the Growatt APX 5.0~30.0P-S0-US User Manual (GR-UM-340-A-02, 2024-11), section 7.2, captured on September 26, 2026.
Where: PDF pages 60-61, section 7.2 APX 5.0P-B1-US (Battery Module)
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "Installation Wall-mounted or Floor installation*3" in the Growatt APX HV Battery System US Datasheet (EN, 202505), captured September 27, 2026 (verified from the rendered page image; the 25.0P/30.0P columns print "Floor installation" only).
Printed as "Rated Voltage 385V" in the APX 5.0P-B1-US battery module table of Growatt's APX HV Battery System US user manual, captured on September 25, 2026. The APX system datasheet prints 400V as the system nominal voltage.
Printed as "Rated Usable Capacity/Energy 100Ah/4.5kWh" in the APX 5.0P-B1-US battery module table of Growatt's APX HV Battery System US user manual, captured on September 25, 2026.
Printed as "IFpP/51/161/119/[1P16S]M/-10+50/90" in the Growatt APX 5.0~30.0P-S0-US User Manual (GR-UM-340-A-02, 2024-11), section 7.2, captured on September 26, 2026.
Where: PDF pages 60-61, section 7.2 APX 5.0P-B1-US (Battery Module)
Printed as "Support the parallel connection of one to six battery modules." in the Growatt APX 5.0~30.0P-S0-US User Manual (GR-UM-340-A-02, 2024-11), section 1.3, captured on September 26, 2026.
Link in: communicate with the previous module; Link out: communicate with the next module; USB: connect a USB flash drive to upgrade firmware
Printed as "4 Link in Communicate with the previous module 5 Link out Communicate with the next module" in the Growatt APX HV Battery System US user manual (EN, 2024-11) (page 10, 1.2.2 APX 5.0P-B1-US (Battery Module) port table).
Where: PDF page 10, 1.2.2 APX 5.0P-B1-US (Battery Module) port table
Printed as "Maximum current (25℃) 12.5A" in the Growatt APX HV Battery System US User Manual (EN, 202411), 7.2 APX 5.0P-B1-US (Battery Module), captured September 27, 2026. One undirected maximum current figure is printed (a lower "Rated current (25℃) 7.6A" is also printed); the maximum figure is recorded for both continuous_discharge_a and continuous_charge_a here rather than assigning a direction the source does not state.
Where: Manual, 7.2 APX 5.0P-B1-US (Battery Module), Maximum current row
Printed as "Do not place the battery pack upside down." in the Growatt APX HV Battery System US user manual (EN, 2024-11) (page 21, 4.1 Basic Installation Requirements, warning).
Where: PDF page 21, 4.1 Basic Installation Requirements, warning
APX 55042-P0-US power module; MIN 3-11.4K TL-XH-US hybrid inverter
Printed as "powers the loads through the single-phase hybrid inverter MIN 3-11.4K TL-XH-US" in the Growatt APX 5.0~30.0P-S0-US User Manual (GR-UM-340-A-02, 2024-11), sections 1.1 and 1.3, captured on September 26, 2026. The module works only inside a system with the APX 55042-P0-US power module.
Printed as "-20℃~+10℃(-4°F~+50°F)/12 months; +10℃~+30℃(+50°F~ +86°F)/12 months; +30℃~+50℃(+86°F~+122°F)/6 months" in the Growatt APX 5.0~30.0P-S0-US User Manual (GR-UM-340-A-02, 2024-11), section 7.2, captured on September 26, 2026.
Where: PDF page 61, section 7.2 row 10 Storage conditions
Printed as "Maximum current (25℃) 12.5A" in the Growatt APX HV Battery System US User Manual (EN, 202411), 7.2 APX 5.0P-B1-US (Battery Module), captured September 27, 2026. One undirected maximum current figure is printed (a lower "Rated current (25℃) 7.6A" is also printed); the maximum figure is recorded for both continuous_discharge_a and continuous_charge_a here rather than assigning a direction the source does not state.
Where: Manual, 7.2 APX 5.0P-B1-US (Battery Module), Maximum current row
Printed as "Operating temperature range -20℃~+50℃(-4°F~+122°F)" in the Growatt APX 5.0~30.0P-S0-US User Manual (GR-UM-340-A-02, 2024-11), section 7.2, captured on September 26, 2026.
Where: PDF pages 60-61, section 7.2 APX 5.0P-B1-US (Battery Module)
Listed as "FCC" in the row "16 Certification & Licensing UL9540A/UL1973/FCC/UN38.3" of the APX 5.0P-B1-US table of Growatt's APX HV Battery System US user manual, captured on September 25, 2026. A mark with no rule part printed.
Printed as "recommended operating temperature 10°C~30°C(+50°F to +86°F)" in the Growatt APX 5.0~30.0P-S0-US User Manual (GR-UM-340-A-02, 2024-11), section 4.1, captured on September 26, 2026.
37.66 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 690 × H: 295 × D: 185 mm / W: 27.2 × H: 11.6 × D: 7.28 in50 kg / 110 lb0.13 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
10/100Missing details45% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
High voltage · Wall / floor · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
CertificatesUL 1973 · UL 9540A +1Claimed9.84 / 45
21.88 evidence points · 45% weight
UL 1973: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: CEC; UL 9540; UL 1973.
Research pending, 0 points: Warranty term, Warranty energy disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1973manufacturer claimpresent at observation[1]
Scope
battery module
Covered models
APX 5.0P-B1-US
Limitations
Growatt's own APX HV Battery System US user manual lists "UL1973" in the row "16 Certification & Licensing UL9540A/UL1973/FCC/UN38.3" of the APX 5.0P-B1-US battery module table. Manufacturer claim; the Intertek UL 1973 Authorization to Mark Growatt hosts names the APX 5.0P-S0-US to 30.0P-S0-US systems, not this module by name. No issuer record was checked.
UL 9540Amanufacturer claimpresent at observation[1]
Scope
battery module
Covered models
APX 5.0P-B1-US
Limitations
Growatt's own APX HV Battery System US user manual lists "UL9540A" in the row "16 Certification & Licensing UL9540A/UL1973/FCC/UN38.3" of the APX 5.0P-B1-US battery module table. Manufacturer claim; the Intertek UL 1973 Authorization to Mark Growatt hosts names the APX 5.0P-S0-US to 30.0P-S0-US systems, not this module by name. No issuer record was checked.
UN 38.3manufacturer claimpresent at observation[1]
Scope
battery module
Covered models
APX 5.0P-B1-US
Limitations
Growatt's own APX HV Battery System US user manual lists "UN38.3" in the row "16 Certification & Licensing UL9540A/UL1973/FCC/UN38.3" of the APX 5.0P-B1-US battery module table. Manufacturer claim; the Intertek UL 1973 Authorization to Mark Growatt hosts names the APX 5.0P-S0-US to 30.0P-S0-US systems, not this module by name. No issuer record was checked.
UL 9540AManufacturer claim · battery moduleClaimedListed when checked
Growatt's own APX HV Battery System US user manual lists "UL9540A" in the row "16 Certification & Licensing UL9540A/UL1973/FCC/UN38.3" of the APX 5.0P-B1-US battery module table. Manufacturer claim; the Intertek UL 1973 Authorization to Mark Growatt hosts names the APX 5.0P-S0-US to 30.0P-S0-US systems, not this module by name. No issuer record was checked.
UL 1973Manufacturer claim · battery moduleClaimedListed when checked
Growatt's own APX HV Battery System US user manual lists "UL1973" in the row "16 Certification & Licensing UL9540A/UL1973/FCC/UN38.3" of the APX 5.0P-B1-US battery module table. Manufacturer claim; the Intertek UL 1973 Authorization to Mark Growatt hosts names the APX 5.0P-S0-US to 30.0P-S0-US systems, not this module by name. No issuer record was checked.
UN 38.3Manufacturer claim · battery moduleClaimedListed when checked
Growatt's own APX HV Battery System US user manual lists "UN38.3" in the row "16 Certification & Licensing UL9540A/UL1973/FCC/UN38.3" of the APX 5.0P-B1-US battery module table. Manufacturer claim; the Intertek UL 1973 Authorization to Mark Growatt hosts names the APX 5.0P-S0-US to 30.0P-S0-US systems, not this module by name. No issuer record was checked.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Chapter 7, Technical Specifications
Retrieved Sep 24, 2026
Growatt's own user manual for the APX 5.0~30.0P-S0-US system (APX 55042-P0-US power module and APX 5.0P-B1-US battery modules), linked from the APX HV US Battery page and captured on September 25, 2026. Chapter 7 prints separate specification tables for the power module and the battery module. Prints no cycle life and no warranty term for the battery module.
Archived copies
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Growatt datasheet
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Growatt APX HV Battery System US user manual (EN, 2024-11)
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
APX 5.0P-B1-US
Observed Sep 24, 2026
UL 9540A: claimed
Finished battery pack / module. Growatt's own APX HV Battery System US user manual lists "UL9540A" in the row "16 Certification & Licensing UL9540A/UL1973/FCC/UN38.3" of the APX 5.0P-B1-US battery module table. Manufacturer claim; the Intertek UL 1973 Authorization to Mark Growatt hosts names the APX 5.0P-S0-US to 30.0P-S0-US systems, not this module by name. No issuer record was checked.
Finished battery pack / module. Growatt's own APX HV Battery System US user manual lists "UL1973" in the row "16 Certification & Licensing UL9540A/UL1973/FCC/UN38.3" of the APX 5.0P-B1-US battery module table. Manufacturer claim; the Intertek UL 1973 Authorization to Mark Growatt hosts names the APX 5.0P-S0-US to 30.0P-S0-US systems, not this module by name. No issuer record was checked.
Finished battery pack / module. Growatt's own APX HV Battery System US user manual lists "UN38.3" in the row "16 Certification & Licensing UL9540A/UL1973/FCC/UN38.3" of the APX 5.0P-B1-US battery module table. Manufacturer claim; the Intertek UL 1973 Authorization to Mark Growatt hosts names the APX 5.0P-S0-US to 30.0P-S0-US systems, not this module by name. No issuer record was checked.
note: UL 1973: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: CEC; UL 9540; UL 1973.