Printed nominal voltage of the six named compatible complete systems, which explicitly list APX 14.3P-B1 as their battery module. The module itself stays 80 V and 0–105 V. No whole-system rating is substituted for the module rating; no module-count calculation. Preliminary EU edition only.
Where: APX Commercial Battery EU preliminary datasheet 202311, PDF p2, APX 129.0H-S1 through APX 200.7H-S1 columns; shared Batteriemodul APX 14.3P-B1 and Nennspannung rows
116.36 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 920 × H: 248 × D: 510 mm / W: 36.2 × H: 9.76 × D: 20.1 in135 kg / 298 lb0.12 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
29/100Missing details65% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
Industrial/Commercial ESS · High voltage · Under 30 kWh · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
CertificatesUL 9540 · UL 1973 +1Claimed15.75 / 45
35 evidence points · 45% weight
UL 9540: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: UL 9540; UL 1973; CEC not assessed for commercial and industrial equipment in this catalog. UL 9540A is recorded but not scored: a thermal-runaway test method, recorded as a documented report and never scored as a listing.
Research pending, 0 points: Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1973manufacturer claimpresent at observation[1]
Scope
battery pack scope unverified
Covered models
APX 14.3P-B1
Limitations
A manufacturer claim, not a listing, certificate or test report. "UL1973" is printed in the "Zertifikate" (certificates) row ("IEC62619 (Zelle & Modul)/ IEC60730/ VDE2510-50/ CE/ CEC/ RCM/ UN38.3/ UL1973/ UL9540/ UL9540A/ FCC") of Growatt's German 129-200kWh APX Commercial Battery EU datasheet (file dated 202311, marked "Vorläufige Version", preliminary), page 2, a row printed once at the foot of the sheet below the battery module block; the sheet's columns are APX 129.0H-S1 to APX 200.7H-S1, and this battery module is the one all six are built from. Captured September 29, 2026. The sheet does not say whether UL 1973 covers the cells, the battery module or the system. No issuer, certificate or report number is printed; the issuer's record was not checked.
UL 9540manufacturer claimpresent at observation[1]
Scope
battery pack scope unverified
Covered models
APX 14.3P-B1
Limitations
A manufacturer claim, not a listing, certificate or test report. "UL9540" is printed in the "Zertifikate" (certificates) row ("IEC62619 (Zelle & Modul)/ IEC60730/ VDE2510-50/ CE/ CEC/ RCM/ UN38.3/ UL1973/ UL9540/ UL9540A/ FCC") of Growatt's German 129-200kWh APX Commercial Battery EU datasheet (file dated 202311, marked "Vorläufige Version", preliminary), page 2, a row printed once at the foot of the sheet below the battery module block; the sheet's columns are APX 129.0H-S1 to APX 200.7H-S1, and this battery module is the one all six are built from. Captured September 29, 2026. The sheet does not say whether UL 9540 covers the cells, the battery module or the system. No issuer, certificate or report number is printed; the issuer's record was not checked.
UL 9540Amanufacturer claimpresent at observation[1]
Scope
battery pack scope unverified
Covered models
APX 14.3P-B1
Limitations
A manufacturer claim, not a listing, certificate or test report. "UL9540A" is printed in the "Zertifikate" (certificates) row ("IEC62619 (Zelle & Modul)/ IEC60730/ VDE2510-50/ CE/ CEC/ RCM/ UN38.3/ UL1973/ UL9540/ UL9540A/ FCC") of Growatt's German 129-200kWh APX Commercial Battery EU datasheet (file dated 202311, marked "Vorläufige Version", preliminary), page 2, a row printed once at the foot of the sheet below the battery module block; the sheet's columns are APX 129.0H-S1 to APX 200.7H-S1, and this battery module is the one all six are built from. Captured September 29, 2026. The sheet does not say whether UL 9540A covers the cells, the battery module or the system. No issuer, certificate or report number is printed; the issuer's record was not checked.
UL 1973Manufacturer claim · battery pack scope unverifiedClaimedListed when checked
A manufacturer claim, not a listing, certificate or test report. "UL1973" is printed in the "Zertifikate" (certificates) row ("IEC62619 (Zelle & Modul)/ IEC60730/ VDE2510-50/ CE/ CEC/ RCM/ UN38.3/ UL1973/ UL9540/ UL9540A/ FCC") of Growatt's German 129-200kWh APX Commercial Battery EU datasheet (file dated 202311, marked "Vorläufige Version", preliminary), page 2, a row printed once at the foot of the sheet below the battery module block; the sheet's columns are APX 129.0H-S1 to APX 200.7H-S1, and this battery module is the one all six are built from. Captured September 29, 2026. The sheet does not say whether UL 1973 covers the cells, the battery module or the system. No issuer, certificate or report number is printed; the issuer's record was not checked.
UL 9540Manufacturer claim · battery pack scope unverifiedClaimedListed when checked
A manufacturer claim, not a listing, certificate or test report. "UL9540" is printed in the "Zertifikate" (certificates) row ("IEC62619 (Zelle & Modul)/ IEC60730/ VDE2510-50/ CE/ CEC/ RCM/ UN38.3/ UL1973/ UL9540/ UL9540A/ FCC") of Growatt's German 129-200kWh APX Commercial Battery EU datasheet (file dated 202311, marked "Vorläufige Version", preliminary), page 2, a row printed once at the foot of the sheet below the battery module block; the sheet's columns are APX 129.0H-S1 to APX 200.7H-S1, and this battery module is the one all six are built from. Captured September 29, 2026. The sheet does not say whether UL 9540 covers the cells, the battery module or the system. No issuer, certificate or report number is printed; the issuer's record was not checked.
UL 9540AManufacturer claim · battery pack scope unverifiedClaimedListed when checked
A manufacturer claim, not a listing, certificate or test report. "UL9540A" is printed in the "Zertifikate" (certificates) row ("IEC62619 (Zelle & Modul)/ IEC60730/ VDE2510-50/ CE/ CEC/ RCM/ UN38.3/ UL1973/ UL9540/ UL9540A/ FCC") of Growatt's German 129-200kWh APX Commercial Battery EU datasheet (file dated 202311, marked "Vorläufige Version", preliminary), page 2, a row printed once at the foot of the sheet below the battery module block; the sheet's columns are APX 129.0H-S1 to APX 200.7H-S1, and this battery module is the one all six are built from. Captured September 29, 2026. The sheet does not say whether UL 9540A covers the cells, the battery module or the system. No issuer, certificate or report number is printed; the issuer's record was not checked.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Page 2, Datenblatt table
Retrieved Sep 28, 2026
Growatt's German-language EU datasheet for the 129-200 kWh APX Commercial Battery (APX 129.0H-S1 to APX 200.7H-S1, power module APX 1000140-C1, battery module APX 14.3P-B1), linked from the German APX Commercial Battery page, captured September 29, 2026. Page 1 marks it "Vorläufige Version" (preliminary version). Its text layer prints the table cells out of order, so column-specific values were read from a local rendering of the unaltered page 2 and quotes confirm only that the printed figure is in the document. No user manual is linked from the page. Manufacturer claims, not independently verified.
Archived copies
Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Page text and download list
Retrieved Sep 28, 2026
Growatt's German product page for the APX Commercial Battery, listed under "Kommerzielle HV Batterie" (commercial HV battery), captured September 29, 2026. Cited for the class, the EU designation of its only download (APX_129-200kWh_EU_Datenblatt_DE_202311) and the link to it. Manufacturer claims, not independently verified.
Archived copy of a document published by Shenzhen Growatt New Energy Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
APX 14.3P-B1
Manufacturer SKU unknown · EU market
Observed Sep 29, 2026
UL 1973: claimed
Battery pack claim; verification pending. A manufacturer claim, not a listing, certificate or test report. "UL1973" is printed in the "Zertifikate" (certificates) row ("IEC62619 (Zelle & Modul)/ IEC60730/ VDE2510-50/ CE/ CEC/ RCM/ UN38.3/ UL1973/ UL9540/ UL9540A/ FCC") of Growatt's German 129-200kWh APX Commercial Battery EU datasheet (file dated 202311, marked "Vorläufige Version", preliminary), page 2, a row printed once at the foot of the sheet below the battery module block; the sheet's columns are APX 129.0H-S1 to APX 200.7H-S1, and this battery module is the one all six are built from. Captured September 29, 2026. The sheet does not say whether UL 1973 covers the cells, the battery module or the system. No issuer, certificate or report number is printed; the issuer's record was not checked.
Battery pack claim; verification pending. A manufacturer claim, not a listing, certificate or test report. "UL9540" is printed in the "Zertifikate" (certificates) row ("IEC62619 (Zelle & Modul)/ IEC60730/ VDE2510-50/ CE/ CEC/ RCM/ UN38.3/ UL1973/ UL9540/ UL9540A/ FCC") of Growatt's German 129-200kWh APX Commercial Battery EU datasheet (file dated 202311, marked "Vorläufige Version", preliminary), page 2, a row printed once at the foot of the sheet below the battery module block; the sheet's columns are APX 129.0H-S1 to APX 200.7H-S1, and this battery module is the one all six are built from. Captured September 29, 2026. The sheet does not say whether UL 9540 covers the cells, the battery module or the system. No issuer, certificate or report number is printed; the issuer's record was not checked.
Battery pack claim; verification pending. A manufacturer claim, not a listing, certificate or test report. "UL9540A" is printed in the "Zertifikate" (certificates) row ("IEC62619 (Zelle & Modul)/ IEC60730/ VDE2510-50/ CE/ CEC/ RCM/ UN38.3/ UL1973/ UL9540/ UL9540A/ FCC") of Growatt's German 129-200kWh APX Commercial Battery EU datasheet (file dated 202311, marked "Vorläufige Version", preliminary), page 2, a row printed once at the foot of the sheet below the battery module block; the sheet's columns are APX 129.0H-S1 to APX 200.7H-S1, and this battery module is the one all six are built from. Captured September 29, 2026. The sheet does not say whether UL 9540A covers the cells, the battery module or the system. No issuer, certificate or report number is printed; the issuer's record was not checked.
note: UL 9540: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: UL 9540; UL 1973; CEC not assessed for commercial and industrial equipment in this catalog. UL 9540A is recorded but not scored: a thermal-runaway test method, recorded as a documented report and never scored as a listing.