About brandDesigns and sells off-grid and renewable energy equipment: DC to AC inverters, solar panels, deep-cycle batteries, solar charge controllers, cables, fuse kits and portable generators. AIMS Power says it was founded by Bruce de Jong, who built its first inverter in 2001.
SKU detail
locator: Store page Quick Comparison, SKU row; manual cover
conditions: AIMS Power's store page prints SKU PIHY9600 (first column of its Quick Comparison table, the page's own product) and heads its Specifications tab with PIHY9600; the manual cover prints "PART #: PIHY4600 & PIHY9600".
AIMS Power's page prints two weights. The PIHY9600 store page prints 55 lbs with its dimensions and 53 lbs in its Additional information table, without saying which is the unit weight. The 55 lbs printed with the dimensions is recorded; 53 lbs is kept beside it.
The PIHY9600 store page prints "55 lbs" after its dimensions; converted to kilograms. The same page's Additional information table prints "Weight" as "53 lbs", kept beside it; the page does not say whether either figure is the unit or the shipping weight.
Where: Store page Specifications tab, Dimensions
Sources
Converted: 55 lb x 0.45359237 = 24.95 kg
24.04 kg
The PIHY9600 store page's Additional information table prints "Weight" as "53 lbs"; converted to kilograms.
The manual prints "Max Peak Power(kVA)(10 min)" as "11.5 | 10.3" and "Max Peak Currenty (A)(10 min)" as "47.9 | 49.5" in the PIHY9600 column; the store page prints the same rows. The two figures are kept as printed.
Where: Manual PDF page 57, Specifications, AC BACK-UP & GENERATOR, Max Peak Power(kVA)(10 min), PIHY9600 column
The manual prints the back-up output as "240 | 208 (not 3 phase)" line to line and "120 | 120" line to neutral, once across both columns; the store page prints "Nominal AC Voltage L-L(V) 240 | 208 (not 3 phase) Nominal AC Voltage L-N(V) 120 | 120".
Where: Manual PDF page 57, Specifications, AC BACK-UP & GENERATOR, Nominal AC Voltage L-L(V) and L-N(V)
The manual prints "Max Charge/Discharge Current(A)" as 50, once across both columns; the store page prints "Max Charge/Discharge Current(A) 50". The battery port is the high-voltage DC port (230 V nominal).
Where: Manual PDF page 57, Specifications, Max Charge/Discharge Current(A)
W 400 × H 603.2 × D 234.9 mm / W 15.7 × H 23.75 × D 9.25 in converted
The PIHY9600 store page prints "Dimensions: 23 3/4″ x 15 3/4″ x 9 1/4″ 55 lbs"; the inch figures are converted to millimeters. The manual's Product Overview drawing is printed once for the two-model manual without naming a model, so it is not cited here.
Where: Store page Specifications tab, Dimensions
Sources
Converted: 23.75 x 15.75 x 9.25 in x 25.4 = 603.2 x 400.0 x 234.9 mm
The manual prints "Ful Color LED, RS485, CAN, Wi-Fi" (sic) and the store page "Display & Communication Interfaces Full Color LED, RS485, CAN, Wi-Fi". The page's features also list 4G, and the manual names a Wi-Fi/GPRS/LAN module; only the table row is recorded.
Where: Manual PDF page 57, Specifications, Display & Communication Interfaces
The store page prints "Max Efficiency(%) 97.6"; the manual's table prints the same figure (read from the page image). PV to battery efficiency is printed as 98.1%.
Where: Store page Specifications tab, Max Efficiency(%); manual PDF page 57
The manual prints "MPPT Range (V)" as 80-550, once across both columns; the store page prints "MPPT Range (V) 80-550". The nominal PV voltage is printed as 360 V.
Where: Manual PDF page 57, Specifications, MPPT Range (V)
211 to 264 @ 240 | 183 to 229 @ 208 (not 3 phase, split phase)
The manual prints "Nominal Grid Voltage (V)" as "211 to 264 @ 240 | 183 to 229 @ 208 (not 3 phase, split phase)", once across both columns; the store page prints the same row.
Where: Manual PDF page 57, Specifications, AC GRID, Nominal Grid Voltage (V)
The manual's AC breaker table prints "Inverter Model PIHY4600 PIHY9600 25A/240V/208V AC breaker 50A/240V/208V AC breaker"; 50 A is the PIHY9600 figure.
Where: Manual AC Connection (PDF page 28), AC breaker specification, PIHY9600
The manual prints "Max Input Current (A)" as "15.5 x 3" in the PIHY9600 column; the store page prints the same. The manual says the series allows up to three PV MPPT inputs; no MPPT count is recorded from that series statement.
Where: Manual PDF page 57, Specifications, Max Input Current (A), PIHY9600 column
The manual prints "Battery Voltage (V)" as 230, once across both columns; the store page prints "Battery Common Voltage (V) 230". This is the high-voltage battery port.
Where: Manual PDF page 57, Specifications, Battery Voltage (V)
UL 1741 SA; CSA 2202 No. 107-01; UL 1998; Rules21; HECO Rule 14; CEC; FCC Part 15 Class B
AIMS Power's claims as printed in the manual and on the store page: "UL 1741 SA | CSA 2202 No. 107-01 |UL 1998 | Rules21 | HECO Rule 14 | IP65 | CEC" (the manual's row runs off the table edge) and EMC "FCC Part 15 Class B". The page's features print "Listed to UL 1741-SA I CSA 22.2 No.107-01 I UL1998 I UL1699B". No certificate or listing record was read.
Where: Manual PDF page 57, Specifications, Certification & Approvals; EMC; store page Features
The manual heads its second column "PIHY9600 9600 WATT (9.6kW)" and prints "Max Continuous Power(kVA)" as 9.6 for the grid and the back-up output; the store page prints "PIHY9600 9600 WATT (9.6kW)" and "Max Continuous Power(kVA) 9.6".
Where: Manual PDF page 57, Specifications, PIHY9600 column heading; AC GRID and AC BACK-UP, Max Continuous Power(kVA)
Lithium | Lead (if using non AIMS lithium batteries requires custom programming)
The manual's table prints "Lithium | Lead (if using non AIMS lithium batteries requires custom programming)"; its battery section says "The PIHY inverters are compatible with AIMS Power lithium batteries only (Part #s: LFP230V96A-M & LFP230V96A-S)", that they are also compatible with all lead acid battery types (gel, AGM, open), and that another lithium battery requires contacting AIMS Power tech support first.
The manual prints "-25 to 60C | -77 to 140F", once across both columns, and the store page prints the same; the Celsius range is recorded. The Fahrenheit lower figure as printed (-77 F) does not match -25 C (-13 F).
Where: Manual PDF page 57, Specifications, Operating Temperature Range
The store page prints "CED Efficiency(%) 97" (sic); the manual's table prints "CEC Efficiency(%)" 97 once across both columns (read from the page image).
Where: Store page Specifications tab, CEC Efficiency(%) (printed "CED"); manual PDF page 57
The store page prints a different back-up current. AIMS Power's hybrid manual prints 40 | 46.5 A for the PIHY9600's back-up output; the PIHY9600 store page prints 41 | 46.5 A for that row (and 40 | 46.5 A for the grid). The manual value is recorded.
The manual prints "Max Continuous Current(A)" as "40 | 46.5" for both the grid and the back-up output in the PIHY9600 column, in the same order as the voltage row's "240 | 208". The store page prints "40 | 46.5" for the grid.
Where: Manual PDF page 57, Specifications, AC GRID and AC BACK-UP & GENERATOR, Max Continuous Current(A), PIHY9600 column
Sources
41 | 46.5 A
The store page prints the back-up output's "Max Continuous Current(A) 41 | 46.5".
211 to 264 @ 240 | 183 to 229 @ 208 (not 3 phase, split phase)
Warranty
10 years
Size
56.68 L* (Calculated from published dimensions)W: 400 × H: 603.2 × D: 234.9 mm / W: 15.7 × H: 23.75 × D: 9.25 inWeight24.95 kg / 55.01 lb
Evidence score
27/100Missing details45% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term10 years12.0 / 30.0
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
The manual's table prints "10 Year Limited" and its introduction "Backed by a 10 year warranty and lifetime tech support."; the store page's features print "10 year warranty".
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
10 years
The manual's table prints "10 Year Limited" and its introduction "Backed by a 10 year warranty and lifetime tech support."; the store page's features print "10 year warranty".
AIMS Power's manual for its two hybrid inverters, PIHY4600 and PIHY9600 (file name AIMS Power Hybrid 110823), linked from the Manual tab of both store pages, captured on October 17, 2026. Its Specifications table (PDF page 57) and Product Overview drawing (PDF page 16) are images with no text layer; they were read from the page images. The table has a PIHY4600 column and a PIHY9600 column, with rows that apply to both printed once across the two; where a row prints two figures separated by a bar, they are kept together as printed. The Product Overview drawing is printed once for the manual and names no model. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
AIMS Power's own store page on aimscorp.net, captured on October 17, 2026; the content is whatever the address served on that date. Its Specifications tab reproduces the manual's table for this model only; its Features list and Additional information table are read for this SKU only, and the Quick Comparison table lists other models and is read only in this SKU's column. The page carries no revision date. Manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Hybrid Power Inverter manual, Part #: PIHY4600 & PIHY9600 (AIMS Power, file AIMS-Power-Hybrid-110823-1)
Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].