Printed as "uses Top Tier Grade A Prismatic LFP (Lithium Iron Phosphate) cells" in the Fortress Power eBoost: manual (page 6, section 4, eBoost Introduction).
Temperature cautions and heater states must be read together. Section 6.3 prints low-temperature charging cautions, near-freezing qualifications, the ambient-freezing prohibition, reduced sub-freezing discharge and lifetime internal-temperature limits. Section 13.2 separately prints heater and charge/discharge status by TMIN, VMIN and SOC. No operating procedure or independent scalar charge/discharge range is selected or inferred. The 8,000+ cycles line is printed as 50°F to 110°F (0°C to 60°C); its Fahrenheit and Celsius figures do not agree with each other. They are retained verbatim in the passage, with no conversion or correction.
Printed as "Included Heating Elements: Integrated heaters" in the Fortress Power eBoost: manual (page 6, section 4, eBoost Introduction). Full section 6.3 passage, retained as printed without choosing a procedure: "CAUTION! Do not attempt to charge the battery below -4 degrees F (-20 degrees C). Attempts to charge below these temperatures can adversely affect State of Health (SOH) and cycle life and will void the warranty; never charge battery if it is frozen; never charge a visibly damaged battery. Charging the battery near freezing should only be done with a low amperage external charger or closed-loop communication inverter unless the battery bank is heated. There is no need to heat the batteries above 50F. Do not charge the battery when the ambient temperature is freezing or below. Discharge current at sub-freezing temperatures should also be significantly reduced. CAUTION! Do Not Operate Fortress Lithium Batteries where average internal battery temperature exceed 30 °C / 86 °F over the life of the battery. Recommended operating parameters of charger/Inverters For 3,000 Cycles: • Internal battery temperature range: 32 F to 120 F (0 °C to 49°C) without close-loop communication. • Bulk voltage and absorb voltage should be set to 55.2V if no battery-inverter communication is available. Recommended operating parameters of charger/Inverters For 8,000+ Cycles: • Operating temperature range: 50°F to 110°F (0°C to 60°C) per Fortress Power recommend charge and discharge inverter configuration." Full section 13.2 heater/status table and following sentence, read on native page 52 (columns Temperature; Heating Element Status (125W); Charge/Discharge Status): "TEMPERATURE HEATING ELEMENT STATUS (125W) CHARGE/DISCHARGE STATUS ≤ -4°F (-20°C) OFF OFF/OFF -4°F (-20°C) <TMIN≤32° F(0°C) ON OFF/ON 32°F(0°C) <TMIN≤41°F(5°C), ON (Stop Heating @ Tmin>50°F (10 °C) ON/ON TMIN>41°F(5°C) OFF ON/ON/ VMIN<45V OR SOC<20% OFF ON/ON The integrated heaters are energy-efficient, activating only when necessary, to preserve battery life and enhance overall system efficiency."
Where: PDF page 6, section 4, eBoost Introduction; page 12, section 6.3, Temperature Considerations; page 52, section 13.2, Heating Element Operation
W 566 × H 960.2 × D 286 mm / W 22.3 × H 37.8 × D 11.3 in converted
Printed as "Dimensions (W*D*H) eWay : 22.84 x 9.52 x 10.18 in (580 x 241.9 x 258.5 mm) | Battery: 22.28 x 11.27 x 37.81 in (566 x 286 x 960.2 mm)" in the Fortress Power eBoost datasheet, captured on September 25, 2026. The battery module figures are recorded; the eWay wiring box is a separate unit.
Where: Datasheet, GENERAL DATA, "Dimensions (W*D*H)" row, Battery entry
Ground-mount, floor-standing and wall-mounted configurations
Printed as "including ground-mount, floor- standing, and wall-mounted configurations" in the Fortress Power eBoost: manual (page 6, section 4, eBoost Introduction).
Printed as "With an IP65 rating, the eBoost battery is highly resistant" in the Fortress Power eBoost: manual (page 6, section 4, eBoost Introduction).
we recommend copper cable starting at 3/0 for runs of less than 10ft
Printed as "we recommend copper cable starting at 3/0 for runs of less than 10ft" in the Fortress Power eBoost: manual (page 13, section 6.7, Tools & Materials).
Where: PDF page 13, section 6.7, Tools & Materials
Printed as "The Fortress Power eBoost is a high-capacity, modular energy storage solution built for residential and light commercial applications. With 16kWh of usable energy per unit and the ability to scale up to 384kWh, eBoost is engineered to handle high load demands while offering the flexibility of stackable, parallel installations." in the Overview of Fortress Power's eBoost data sheet (English, 2026), the data sheet this record already cites (archived copy). One unit is the eBoost 16 battery module (model number "eBoost DC Energy Storage System 16 P1" in the same sheet's table, which prints "Nominal Energy 16.077kWh**" for it). The sheet prints no depth of discharge or test condition with the usable figure.
Where: Data sheet, page 1, Overview paragraph, sentence beginning "The Fortress Power eBoost is a high-capacity, modular energy storage solution"
Printed as "up to 16 eBoost 16kWh batteries can be connected in parallel" in the Fortress Power eBoost: manual (page 48, section 11, Commissioning multiple eBoost batteries in Parallel).
Where: PDF page 48, section 11, Commissioning multiple eBoost batteries in Parallel
From the California Energy Commission list, not a maker document. This figure is printed on the California Energy Commission Solar Equipment List (data unchanged since October 1, 2026) as submitted for the listing. No maker document in the catalog prints it for this model yet.
Listed as "12.8" under "Maximum Continuous Discharge Rate (kW)" on the California Energy Commission list (data unchanged since October 1, 2026; downloaded October 11, 2026). Moved on October 18, 2026 from the duplicate record fortress-power-eboost-dc-energy-storage-system-16-p1 (the same product); Fortress Power's eBoost data sheet (V.EBOOST_051326) prints a 16kW/10s surge discharge power but no continuous power.
Where: Row 176, Maximum Continuous Discharge Rate (kW)
Printed as "The eBoost maximum discharge current is 250A continuous" in the Fortress Power eBoost: manual (page 24, section 9.3, Unacceptable Configurations notes).
Where: PDF page 24, section 9.3, Unacceptable Configurations notes
Printed as "Blue Can2_H PCS CAN communication"; "White-Brown RS485A1 PCS 485 Communication" in the Fortress Power eBoost: manual (page 20, section 8.2.2.1, Port Definition). The eWay communication board RJ45 pin table assigns PCS (inverter) CAN and PCS RS485 communication.
Where: PDF page 20, section 8.2.2.1, Port Definition
General range is subject to the manual operating conditions. This table row does not override section6.3 or establish separate charge/discharge limits. The full section6.3 passage and section13.2 heater/status table are retained with self_heating. The section6.3 8,000+cycles line has inconsistent printed Fahrenheit/Celsius endpoints; no conversion, corrected range or procedure is supplied.
General Operating Temperature row prints "-4 ºF - 140 ºF (-20 ºC - 60 ºC)*". Its asterisk footnote prints "Performance will degrade at operating temperatures above 104 ºF (40 ºC)". This is a general operating range, not separate charging and discharging limits, and it does not establish unrestricted current throughout the range. Section6.3 cautions and section13.2 heater/status table remain in the located self-heating conditions without selecting a procedure.
Where: PDF page 7, section 5.1 Datasheet, Operating Temperature row and asterisk footnote; page 12, section 6.3; page 52, section 13.2
No reviews. Be the first to review this product: Write a review
Sellers
Stock isn't shown.
Store
Checked
More info
Store link
SanTan Solar
No store reviews yet
Checked Nov 16, 2026
More info
One unit as listed by SanTan Solar on October 15, 2026; tax and shipping excluded. Not refreshed automatically yet. · Store SKU FP-EBOOST16KWHPrice readings (23)
One new unit at the exact variant price in ShopSolar's product feed (shopsolarkits.com), captured October 4, 2026; shipping and tax are not included. · Store SKU eBoost-16Price readings (26)
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
48 V · Wall / floor · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
CertificatesCEC · UL 9540 +6CEC listed45 / 45
100 evidence points · 45% weight
CEC listing: full credit for the certificate criterion. Exact model found in the dated CEC equipment list. This is not a safety certification or system approval. Applies: CEC; UL 9540; UL 1973.
Not documented, 0 points: Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
A green check means we found this model, with that standard, on the certifier's own listing, the test lab's own report, or the California Energy Commission's equipment list.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CECauthority listing reportedlisted as of snapshot[6][7]
Scope
equipment listing
Covered models
eBoost DC Energy Storage System 16 P1
Limitations
Model eBoost DC Energy Storage System 16 P1 listed on the California Energy Commission Energy Storage System List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Fortress Power LLC, as "eBoost DC Energy Storage System 16 P1" (row 1877), CEC listing date 2025-12-22. Fortress Power's eBoost data sheet prints "eBoost DC Energy Storage System 16 P1" as the Model Number of the eBoost 16. This is an equipment listing, not UL certification or complete-system approval.
CEC (printed by the maker; issuer not named)manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
eBoost 16
Limitations
Datasheet CEC claim only; exact listed model/configuration has not been matched to an authority record. The maker prints only the letters "CEC" and names no issuer or program; it is not a California Energy Commission equipment list entry (those rows cite the CEC list itself).
UL 1973manufacturer claimpresent at observation[8]
Scope
battery pack scope unverified
Covered models
eBoost DC Energy Storage System16P1; eBoost DC Energy Storage System32P2; eBoost DC Energy Storage System48P3
Limitations
Finished LiFePO4 battery system; manufacturer-hosted Intertek Authorization to Mark copy, not live issuer lookup. Manufacturer-hosted copy; exact installed configuration and issuer status require confirmation. Standard edition: ANSI/CAN/UL1973:2022 Ed.3. Issued 2025-11-10.
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
CEC (printed by the maker; issuer not named)Manufacturer claim · equipment listingClaimedListed when checked
Datasheet CEC claim only; exact listed model/configuration has not been matched to an authority record. The maker prints only the letters "CEC" and names no issuer or program; it is not a California Energy Commission equipment list entry (those rows cite the CEC list itself).
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
California Energy Commission Solar Equipment List as downloaded on October 11, 2026 (its data key says updated October 1, 2026). It records that a listed model was submitted with the stated certification, certifying entity and dates; it is a state equipment list, not the certification body's own record, and absence from it says nothing about a product.
Document group: datasheet. Attached by exact model or SKU naming in the document text.
Location: Linked from https://www.fortresspower.com/products/eboost/ with the link text "Fortress Power eBoost Handle Kit | Data Sheet"
Retrieved Sep 19, 2026
PDF downloaded from a link published on the manufacturer's own site and preserved byte for byte. It establishes the document that link served on the access date. It is attached only to catalog rows whose exact documented SKU or exact model designation appears in this document's own text, so a document covering several models is attached to exactly those rows. No issuer verified any certification it names, no revision history is established, and no specification value was read from it in this pass.
Archived copies
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Document group: datasheet. Attached by exact model or SKU naming in the document text.
Location: Linked from https://www.fortresspower.com/products/eboost/ with the link text "Fortress Power eBoost | Data Sheet (Spanish)"
Retrieved Sep 19, 2026
PDF downloaded from a link published on the manufacturer's own site and preserved byte for byte. It establishes the document that link served on the access date. It is attached only to catalog rows whose exact documented SKU or exact model designation appears in this document's own text, so a document covering several models is attached to exactly those rows. No issuer verified any certification it names, no revision history is established, and no specification value was read from it in this pass.
Archived copies
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Document group: manual. Attached by exact model or SKU naming in the document text.
Location: Linked from https://www.fortresspower.com/products/eboost/ with the link text "Fortress Power eBoost | Installation Manual (Spanish)"
Retrieved Sep 19, 2026
PDF downloaded from a link published on the manufacturer's own site and preserved byte for byte. It establishes the document that link served on the access date. It is attached only to catalog rows whose exact documented SKU or exact model designation appears in this document's own text, so a document covering several models is attached to exactly those rows. No issuer verified any certification it names, no revision history is established, and no specification value was read from it in this pass.
Archived copies
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Fortress Power eBoost | Installation Manual (Spanish)
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Order: products a manufacturer names first, then by Evidence score at default weights.
Matched on printed specifications only: each manufacturer's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a manufacturer does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
eBoost 16
Published model / SKU
eBoost DC Energy Storage System 16 P1
The Model Number Fortress Power's eBoost data sheet prints for the eBoost 16, and the model the duplicate record fortress-power-eboost-dc-energy-storage-system-16-p1 used.
Product / system scope unresolved. Model eBoost DC Energy Storage System 16 P1 listed on the California Energy Commission Energy Storage System List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Fortress Power LLC, as "eBoost DC Energy Storage System 16 P1" (row 1877), CEC listing date 2025-12-22. Fortress Power's eBoost data sheet prints "eBoost DC Energy Storage System 16 P1" as the Model Number of the eBoost 16. This is an equipment listing, not UL certification or complete-system approval.
note: CEC listing: full credit for the certificate criterion. Exact model found in the dated CEC equipment list. This is not a safety certification or system approval. Applies: CEC; UL 9540; UL 1973.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.