conditions: Printed as "sku":"ZMM100BP5-CONT-1.5M" for the variant "5kWh LFP Battery" in EcoFlow's Australia store product data, captured on September 29, 2026.
Printed as "LiFePO4" under Battery Chemistry in the English Battery Specifications table of EcoFlow's LFP Battery User Manual V1.1 (5kWh LFP Battery column).
Where: English section 4, Battery Specifications, 5kWh LFP Battery
Printed as "Approx. 89.5 lbs(40.6 kg)" in the English Battery Specifications table of EcoFlow's LFP Battery User Manual V1.1 (5kWh LFP Battery column).
Where: English section 4, Battery Specifications, 5kWh LFP Battery
Printed as "3,500 cycles to 80% capacity" in the English Battery Specifications table of EcoFlow's LFP Battery User Manual V1.1 (5kWh LFP Battery column). The table prints the 5kWh column first and the 2kWh column second.
Where: English section 4, Battery Specifications, 5kWh LFP Battery
Printed as "5120Wh(100Ah)" in the English Battery Specifications table of EcoFlow's LFP Battery User Manual V1.1 (5kWh LFP Battery column). The table prints the 5kWh column first and the 2kWh column second.
Where: English section 4, Battery Specifications, 5kWh LFP Battery
Auto-heating when charging temperature falls below 0°C (32°F)
Printed as "This battery will activate auto-heating function when charging temperature falls below 0°C (32°F)." in EcoFlow's LFP Battery User Manual V1.1.
W 260 × H 300 × L 500 mm / W 10.2 × H 11.8 × L 19.7 in converted
Printed as "500 x 260 x 300 mm" in the English Battery Specifications table of EcoFlow's LFP Battery User Manual V1.1 (5kWh LFP Battery column). The document prints the three dimensions without naming the axes; they are recorded in the printed order.
Where: English section 4, Battery Specifications, 5kWh LFP Battery
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "Stackable and Expandable: Available in two sizes, both 2 and 5kWh stack up to 3 for a capacity of up to 15kWh.". Classified as Stackable from the maker's own words for this model.
Printed as "51.2V" beside "5120Wh(100Ah)" in the English Battery Specifications table of EcoFlow's LFP Battery User Manual V1.1 (5kWh LFP Battery column).
Where: English section 4, Battery Specifications, 5kWh LFP Battery
Printed as "only supports parallel connection."; "Do not use the battery in series as this can potentially damage the battery." in the EcoFlow 2kWh LFP Battery_User Manual_V1.1_(EN+DE+FR+IT+ES+CHS) (page 14, 6.4 Connecting Batteries in Parallel). The manual covers both the 5kWh LFP Battery and the 2kWh LFP Battery; English section.
Where: PDF page 14, 6.4 Connecting Batteries in Parallel
Printed as "The EcoFlow 5kWh LFP Battery has a built-in DC 70V/150A replaceable fuse" in the EcoFlow 2kWh LFP Battery_User Manual_V1.1_(EN+DE+FR+IT+ES+CHS) (page 15, 6.6 Replacing the Fuse). The manual covers both the 5kWh LFP Battery and the 2kWh LFP Battery; English section. The same 5kWh LFP Battery manual applies to every regional listing of this model.
Printed as "5120Wh(100Ah)" in the English Battery Specifications table of EcoFlow's LFP Battery User Manual V1.1 (5kWh LFP Battery column); the same figure expressed in kWh.
Where: English section 4, Battery Specifications, 5kWh LFP Battery
Printed as "Max Continued Charging Current" 80A in the English Battery Specifications table of EcoFlow's LFP Battery User Manual V1.1 (5kWh LFP Battery column). The table prints the 5kWh column first and the 2kWh column second.
Where: English section 4, Battery Specifications, 5kWh LFP Battery
Printed as "-20°C~50°C (-4°F~122°F) (auto-heating below 0°C (32°F))" for the charge temperature range in section 4.3 of EcoFlow's LFP Battery User Manual V1.1, which prints one set of ranges for both the 5kWh and 2kWh LFP Battery.
Printed as "Charge heating is automatically activated when ambient temperature is below 0°C (32°F)" in the EcoFlow 2kWh LFP Battery_User Manual_V1.1_(EN+DE+FR+IT+ES+CHS) (page 13, 6.3.1 Charge Heating). Activation also requires the battery to be in charging mode with charging input of at least 250 W; heating stops above 10°C internal temperature. The manual covers both the 5kWh LFP Battery and the 2kWh LFP Battery; English section.
In caravans and boats the battery shall be fixed (LFP Battery Mounting Bracket / Wall Mounting Clamp) to prevent falling over
Printed as "In case of movement and vibration, such as in caravans and boats, the battery shall be fixed in the following three configurations to prevent the battery from falling over." in EcoFlow's LFP Battery User Manual (PDF page 16). The manual applies to this model: LFP Battery User Manual V1.1 covers both the EcoFlow 5kWh LFP Battery and 2kWh LFP Battery (EN+DE+FR+IT+ES+CHS, global file on websiteoss.ecoflow.com).
Printed as "-20°C~50°C (-4°F~122°F) (optimal 15°C~25°C (59°F~77°F))" for the storage temperature in section 4.3 of EcoFlow's LFP Battery User Manual V1.1, which prints one set of ranges for both sizes.
Printed as "Max Continued Discharge current" 100A in the English Battery Specifications table of EcoFlow's LFP Battery User Manual V1.1 (5kWh LFP Battery column). The table prints the 5kWh column first and the 2kWh column second.
Where: English section 4, Battery Specifications, 5kWh LFP Battery
Printed as "The LFP Battery Cable consists of an AWG4 power cable (max. continuous current 100A)" in the EcoFlow 2kWh LFP Battery_User Manual_V1.1_(EN+DE+FR+IT+ES+CHS) (page 11, 6.2.1 Connecting the Battery to the EcoFlow Power Kits, footnote). The Battery Cable is listed in 3. What's in the Box. The manual covers both the 5kWh LFP Battery and the 2kWh LFP Battery; English section.
Where: PDF page 11, 6.2.1 Connecting the Battery to the EcoFlow Power Kits, footnote
Printed as "Charging Cut-off Voltage" 57.6V in the English Battery Specifications table of EcoFlow's LFP Battery User Manual V1.1 (5kWh LFP Battery column). The table prints the 5kWh column first and the 2kWh column second.
Where: English section 4, Battery Specifications, 5kWh LFP Battery
Printed as "-20°C~50°C (-4°F~122°F)" for the discharge temperature range in section 4.3 of EcoFlow's LFP Battery User Manual V1.1, which prints one set of ranges for both sizes.
Printed as "Discharging Cut-off Voltage" 40V in the English Battery Specifications table of EcoFlow's LFP Battery User Manual V1.1 (5kWh LFP Battery column). The table prints the 5kWh column first and the 2kWh column second.
Where: English section 4, Battery Specifications, 5kWh LFP Battery
39 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 260 × H: 300 × L: 500 mm / W: 10.2 × H: 11.8 × L: 19.7 in40.6 kg / 89.5 lb0.13 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
4/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
48 V · Stackable · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity3,500 cycles4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
EcoFlow's own manual, captured October 15, 2026 with the paced research fetcher (robots.txt read first). Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Variant selector; product description
Retrieved Sep 28, 2026
EcoFlow's own Australia store page for the EcoFlow LFP Battery, captured on September 29, 2026. Cited for the variant names and statements it prints; it prints no specification table. EcoFlow claims, not independent tests.
Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].