Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Dyness B4850 lithium battery module, front view, manufacturer image from the dyness.us B4850 pageDC battery module
Dyness B4850 rack battery module (2.4 kWh, 48 V)
Key specs
1 spec not documented yet: usable energyHelp fill in ›
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Chemistry | LFP | Printed as "Battery Type LiFePO4" and "lithium iron phosphate (LiFePO4)". Internet Archive copies of Dyness documents. Where: Page Technical Specifications; manual Product Properties | [3] [2] |
| Grounding | Ground connection point on the shell | Printed as "2 Ground connection point Shell ground connection" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 9, Table 2-3 Interface Definition). Where: PDF page 9, Table 2-3 Interface Definition | [2] |
| Weight | 22 kg / 49 lb converted | Printed as "Net Weight 22 kg" on the page and "≈22kg" in the manual. Internet Archive copies of Dyness documents. Where: Page Technical Specifications; manual Table 2-1 | [3] [2] |
| Cycle life | 6,000 cycles ≥6000 Cycles as printed | Printed as "Cycle Life ≥6000 Cycles" with no depth of discharge, rate or temperature stated. Internet Archive copy of the Dyness page. Where: Technical Specifications | [3] |
| Capacity | 50 Ah | As printed. Internet Archive copy of the Dyness manual. Where: Table 2-2 | [2] |
| Surge output | 100 A for 15 s | Printed as "Peak Power Charge/Discharge Current (A) 100 (15S)" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 8, Table 2-2 B4850 performance parameter). Where: PDF page 8, Table 2-2 B4850 performance parameter | [2] |
| Dimensions | W 405 × H 90 × L 480 mm / W 15.9 × H 3.5 × L 18.9 in converted | Printed in the manual as "480×405×90mm". The page prints "Dimension[W*D*H] 480*360*90/480*405*90mm", two sets without saying what distinguishes them; the manual's set is recorded as width 480, depth 405 and height 90 (stored as length, width, height). Internet Archive copies of Dyness documents. Where: Manual Table 2-1; page Technical Specifications | [2] [3] |
| Mounting type | Standardized 19-inch 2U chassis design | Printed as "Standardized 19-inch 2U chassis design" in the product features. Internet Archive copy of the Dyness page. Where: Product Features | [3] |
| Peak charge | 100 A | Printed as "Peak Power Charge/Discharge Current (A) 100 (15S)", read as 100 A for 15 seconds, one figure for charge and discharge. Internet Archive copy of the Dyness manual. Where: Table 2-2 | [2] |
| Battery format | Server rack DetailsCharged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim. The site's classification of the printed wording "Standardized 19-inch 2U chassis design" (product features) as the "Server rack" battery format. This is the catalog's own format grouping, not a manufacturer term; the printed wording is kept in its own field where the catalog has one. Revised on 30 September 2026: The recorded value "19-inch 2U rack chassis" was printed text, not one of the site's battery format codes, so the grouping could not read it. It is replaced by the matching code; the printed wording stays in the record history and, where a field exists for it, in that field. Source product page: Dyness B4850 low voltage battery page (Internet Archive copy of December 3, 2024)Location: Product Features | ||
| Communications | CAN; RS485 | Printed as "support CAN/ RS485 communication (factory default CAN communication)". Internet Archive copy of the Dyness manual. Where: Table 2-3 Interface Definition | [2] |
| Address setting | Master DIP switch set according to the inverter model; slaves keep DIP 0000 | Printed as "DIP switch position (master communication protocol and baud rate selection)"; "the slaves keep the DIP 0000" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (pages 9, 10, DIP switch description). Where: PDF pages 9, 10, DIP switch description | [2] |
| Enclosure rating | IP20 | Printed as "Protection Level IP20". Internet Archive copy of the Dyness page. Where: Technical Specifications | [3] |
| Maximum charge | 50 A | Printed as "Max. Power Charge/Discharge Current (A) 50", one figure for charge and discharge. Internet Archive copy of the Dyness manual. Where: Table 2-2 | [2] |
| Peak discharge | 100 A | Printed as "Peak Power Charge/Discharge Current (A) 100 (15S)", read as 100 A for 15 seconds, one figure for charge and discharge. Internet Archive copy of the Dyness manual. Where: Table 2-2 | [2] |
| Battery wire size | 25 mm² power cables (optional purchase) | Printed as "Power cable- positive Red /25mm2/L2050mm Optional" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 17, Packing list). Where: PDF page 17, Packing list | [2] |
| Nominal voltage | 48 V | Printed as "Nominal Voltage (V) 48" and "DC48V". Internet Archive copy of the Dyness manual. Where: Tables 2-1 and 2-2 | [2] |
| Included equipment | Parallel cables (25 mm², 215 mm), communication parallel cable (250 mm), communication cable to inverter (2000 mm), ground wire, user manual, 4 M6×14 combination screws; power cables optional | Printed as "Parallel cable- positive Red /25mm2/L215mm 1"; "Communicatio n cable-to inverter Black /L2000mm /Double RJ45 plug 1"; "Screw Combination screws M6*14 4" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (pages 17, 18, Packing list). Where: PDF pages 17, 18, Packing list | [2] |
| Max parallel units | 40 count | Printed as "Up to 40 units in parallel" ("2.4kWh--96kWh Capacity"). Internet Archive copy of the Dyness page. Where: Product Features; Technical Specifications | [3] |
| Nominal energy | 2.4 kWh | Printed as "Nominal Energy (kWh) 2.4" in the manual and "Nominal Battery Energy 2.4 kWh" on the page. Internet Archive copies of Dyness documents; usable energy is not printed. Where: Manual Table 2-2; page Technical Specifications | [2] [3] |
| Communication ports | CAN/485 communication port (factory default CAN); Dry contact; ADD DIP switch | Printed as "9 CAN/485 Communication port, support CAN/ RS485 communication (factory default CAN communication)"; "10 DRY CONTACT / 11 ADD DIP switch" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 9, Table 2-3 Interface Definition). Where: PDF page 9, Table 2-3 Interface Definition | [2] |
| Maximum discharge | 50 A | Printed as "Max. Power Charge/Discharge Current (A) 50", one figure for charge and discharge. Internet Archive copy of the Dyness manual. Where: Table 2-2 | [2] |
| Operating voltage | 42 to 54 V DC | Printed as "Work Voltage Range (V) 42~54". Internet Archive copy of the Dyness manual. Where: Table 2-2 | [2] |
| Charge temperature | 0 to 55 °C / 32 to 131 °F converted | Printed as "Charging temperature range is 0oC~+55oC" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 15, section 3 Environmental requirements). Where: PDF page 15, section 3 Environmental requirements | [2] |
| Max charge voltage | 53.5 V | Printed as "Max Charging(Bulk) Voltage: 53.5V" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 23, Battery parameter settings on the inverter). Where: PDF page 23, Battery parameter settings on the inverter | [2] |
| Recommended charge | 25 A | Printed as "Recommended Charge/Discharge Current (A) 25", one figure for charge and discharge. Internet Archive copy of the Dyness manual. Where: Table 2-2 | [2] |
| Battery compatibility | Inverters listed for master DIP settings include GOODWE, Solis, LUX, Sofar, DEYE (SUNSYNK), VICTRON, IMEON, Sungrow, SMA, Growatt SPF HVM-P/ES/WPV (RS485) and Schneider Conext Series | Printed as "GOODWE, Solis, LUX, Sofar, DEYE(SUNSYNK), VICTRON, IMEON, Sungrow, SMA"; "Growatt SPF HVM-P/ES/WPV by RS485 communication"; "communicates with the Schneider Conext Series" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 10, DIP switch description). Where: PDF page 10, DIP switch description | [2] |
| Storage temperature | -10 to 35 °C / 14 to 95 °F converted | Printed as "Storage temperature: -10oC~+35oC" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 15, section 3 Environmental requirements). Where: PDF page 15, section 3 Environmental requirements | [2] |
| Included cable limit | 120 A | Printed as "The limited continuous current for each pair of power cable is 120A." in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 22, section 3, Note 3). Where: PDF page 22, section 3, Note 3 | [2] |
| Recommended protection | Circuit breaker between inverter and battery: voltage above 60 V; current = inverter power / 45 V | Printed as "It is better to add a circuit breaker between the inverter and the battery system."; "Voltage: U>60V Current: I = Inverter Power/45V" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 21, Electrical installation). Where: PDF page 21, Electrical installation | [2] |
| Discharge temperature | -20 to 55 °C / -4 to 131 °F converted | Printed as "Discharging temperature range is -20oC~+55oC" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 15, section 3 Environmental requirements). Where: PDF page 15, section 3 Environmental requirements | [2] |
| Operating temperature | -20 to 55 °C / -4 to 131 °F converted | Printed as a working environment range of "-20oC ~ +55 oC"; separate charge and discharge ranges are not printed. Internet Archive copy of the Dyness manual. Where: Section 1 Product Properties | [2] |
| Other compliance claims | This battery product passed the TUV certification test.; This battery product meets European directive requirements.; Comply with European ROHS, Certified SGS | Manufacturer claims recorded as printed in an Internet Archive copy of the Dyness manual. The manual names no standard number, certificate or file number; certificate PDFs in the robots-disallowed dyness.com folder were not read, and no issuer record was checked. Where: Section 1 Product Properties; warning label page | [2] |
| Recommended discharge | 25 A | Printed as "Recommended Charge/Discharge Current (A) 25", one figure for charge and discharge. Internet Archive copy of the Dyness manual. Where: Table 2-2 | [2] |
| Discharge cutoff voltage | 47 V | Printed as "Shut Down(cut off) Voltage: 47V" in the Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (page 23, Battery parameter settings on the inverter). Recommended inverter setting. Where: PDF page 23, Battery parameter settings on the inverter | [2] |
| Recommended charge voltage | 53.5 V | Printed as "Charge Voltage (Vdc) 53.5". Internet Archive copy of the Dyness manual. Where: Table 2-2 | [2] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Basic specs
- 2.4 kWhDischarge 50 A max.Charge 25 A recommendedPeak current: 100 A
- $ / rated kWh
- Unavailable
- Warranty
- 7 yearsSee terms
- Lifetime production
- 6.7 MWhWarranty limit
- Size
- 17.5 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 405 × H: 90 × L: 480 mm / W: 15.9 × H: 3.5 × L: 18.9 in22 kg / 49 lb0.14 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
48 V · Server rack · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Warranty term7 / 20
7 years · 20% weight
7 of 20 years, the best documented for a small DC battery (printed by the maker): Bioenno Power 6V 3Ah LiFePO4 Battery (PVC, BLF-0603W)
35 / 100 × 20 = 7 points.
Warranty energy disclosure0 / 10
0 evidence points · 10% weight
No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
0 / 100 × 10 = 0 points.
Lifetime / capacity4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
20 × 0.2 = 4 points.
Research pending, 0 points: Certificates, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Certificates
EN 62619:2017issuer record foundunknown[5]
- Scope
- battery module
- Covered models
- B4850; Powerbox F-2.5; Powerbox F-5.0; Powerbox F-7.5; Powerbox F-10.0
- Limitations
- TÜV Rheinland’s Certipedia record for certificate R 50464979 (EN 62619:2017; holder DAQIN NEW ENERGY TECH (TAIZHOU) CO., LTD.; date of issue 2020-04-27; model designation (1) B4850 to (5) Powerbox F-10.0), read on October 15, 2026, prints "Invalid Certificate" and "This certificate is no longer valid." It gives no date and no reason for that status. The EN 62619 certificate Dyness published is kept as the maker’s claim in its own row.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Oct 15, 2026
- Source
- [5]
EN 62619:2017manufacturer claimpresent at observation[6]
- Scope
- battery module
- Covered models
- B4850
- Limitations
- Certificate hosted by Dyness under the file name B4850PowerboxF62619cert.pdf, read from an Internet Archive copy (scanned page, no text layer, read from the page images). It is a TUV Rheinland LGA Products GmbH certificate, Certificate No. R 50464979, Sheet 0001, date of issue 27.04.2020, license holder DAQIN NEW ENERGY TECH (TAIZHOU) CO.,LTD., "Tested acc. to EN 62619:2017", with test mark wording "Type Approved, Safety, Regular Production Surveillance". It lists type designations (1) B4850 and (2) to (5) Powerbox F-2.5, F-5.0, F-7.5 and F-10.0 (DYNESS), rated voltage 48V, and (1) 2.4kWh. The standard is recorded as printed (EN, not IEC). Part of the certified-product line is not legible in the scan. No issuer directory record was checked.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [6]
IEC 62040-1:2017manufacturer claimpresent at observation[7]
- Scope
- battery module
- Covered models
- B4850
- Limitations
- Certificate hosted by Dyness, read from an Internet Archive copy (scanned pages, no text layer, read from the page images). Page 3 is a TUV Rheinland LGA Products GmbH Certificate of Conformity, Registration No. AK 50464672 0001, Report No. 60359598 001, dated 15.04.2020, holder DAQIN NEW ENERGY TECH(TAIZHOU) CO.,LTD., product "Battery Charger (LFP Lithium Ion Battery)", Type Designation B4850, Serial Number "Engineering Sample", Firmware Version V2.1.1, "Tested acc. to: IEC 62040-1:2017". The certificate states that it "does not imply assessment of the production of the product". Pages 1 and 2 are a separate certificate (AK 50464675 0001) for Powerbox F-2.5, F-5.0, F-7.5 and F-10.0, not the B4850. No issuer directory record was checked.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [7]
UN 38.3manufacturer claimpresent at observation[8]
- Scope
- battery module
- Covered models
- B4850
- Limitations
- Test report hosted by Dyness, read from an Internet Archive copy. CQC Intime Testing Technology Co.,Ltd report 20200406J05445, sample "Energy Storage Module", Model/Type "B4850 48V 50Ah 2.4kWh", trade mark DYNESS, applicant and manufacturer Daqin New Energy Tech(Taizhou)., Ltd., standard "ST/SG/AC.10/11/Rev.6/Amend.1/Section 38.3", issued 2020-05-15, conclusion "The Submitted Sample(s) Meet the Requirement of the Standard." UN 38.3 is a transport test, not a stationary storage safety listing. No issuer record was checked.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [8]
Warranty
| Field | Value | Conditions | Source |
|---|---|---|---|
| Territory | Australia | The document headers read "Limited Warranty (Australia)". Internet Archive copy. Where: Page headers | [4] |
| Start basis | earlier of completed first installation or 180 days after shipment from Dyness | From Dyness's B4850 warranty terms for Australia (Internet Archive copy); no North America B4850 warranty was found. As printed. Where: Section 3 Warranty start date definition | [4] |
| Retention | 70 % | From Dyness's B4850 warranty terms for Australia (Internet Archive copy); no North America B4850 warranty was found. Seventy percent of Nominal Energy for ten years from the warranty start date or the Minimum Energy Throughput, whichever occurs first. Where: Section 4 Performance Warranty | [4] |
| Warranty term | 7 years 7 years, or 10 with registration and approval; the same document also states 10 years free from defects (Australia terms) | From Dyness's B4850 warranty terms for Australia (Internet Archive copy); no North America B4850 warranty was found. The document prints both "seven (7) years from the warranty start date", extendable to ten years if the customer registers on Dyness's website and obtains Dyness's official approval, and, in the same section, that the product "will be free from defects in materials or workmanship for ten (10) years"; both are kept (the ten-year statement is listed as an alternative). Use without communications or in RV, camp or marine applications is limited to five years. Where: Section 3 Warranty Period Sources10 years Printed in the same section: "Dyness warrants that the Product will be free from defects in materials or workmanship for ten (10) years from Warranty Start Date". Australia terms, Internet Archive copy. [4] | [4] |
| Warranted throughput | 6.7 MWh | From Dyness's B4850 warranty terms for Australia (Internet Archive copy); no North America B4850 warranty was found. Printed as Minimum Energy Throughput 6.7 MWh for the B4850. Where: Table 4-1 | [4] |
| Extended warranty | 10 years with registration on the Dyness website and Dyness official approval | From Dyness's B4850 warranty terms for Australia (Internet Archive copy); no North America B4850 warranty was found. As printed. Where: Section 3 Warranty Period | [4] |
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Section 1 Product Properties; Section 2 Tables 2-1 to 2-3
Retrieved Sep 24, 2026
Internet Archive copy of Dyness's own 27-page B4850 user manual, captured by the Internet Archive on March 5, 2026 from dyness.com/Public/Uploads/uploadfile/files/20241023/B4850UserManualEN.pdf and retrieved on September 25, 2026. dyness.com's robots.txt disallows that folder, so the file was not fetched from Dyness, and dyness.us publishes no B4850 document. The manual states that information might be subject to change without notice.
Warranty
- Dyness Warranty Terms for Energy Storage Solutions, B4850, Limited Warranty (Australia), V2.0-202308 (Internet Archive copy of March 5, 2026)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Sections 2 to 4 and Table 4-1
Retrieved Sep 24, 2026
Internet Archive copy of Dyness's own 11-page B4850 warranty terms, captured by the Internet Archive on March 5, 2026 from dyness.com/Public/Uploads/uploadfile/files/20250208/DynessWarrantyTermsB4850202308.pdf and retrieved on September 25, 2026. dyness.com's robots.txt disallows that folder, so the file was not fetched from Dyness. Its page headers read "Limited Warranty (Australia)"; no North America B4850 warranty was found on dyness.us.
Other documents
- Dyness B4850 low voltage battery page (Internet Archive copy of December 3, 2024)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Product Features; Technical Specifications
Retrieved Sep 24, 2026
Internet Archive copy of Dyness's own global B4850 product page, captured by the Internet Archive on December 3, 2024 and retrieved on September 25, 2026. The live address now redirects to the DL5.0C Pro page, and dyness.us prints no B4850 figure. It prints a feature list and a Technical Specifications summary. Values may have changed since the capture date.
Archive and older revisions
Archive and older revisions2
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
- Dyness B4850 product page (dyness.us, September 25, 2026 capture)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Product title and gallery
Retrieved Sep 24, 2026
Dyness USA's own B4850 store page, captured on September 25, 2026. It prints the model name, a product photograph and "Sold Out", and no specification; it is cited for the model name, the photograph and the listing only.
- UN 38.3 Test Report 20200406J05445, Energy Storage Module B4850 (CQC Intime Testing Technology), hosted by Dyness (Internet Archive copy of March 6, 2026)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Pages 1 and 2
Retrieved Sep 24, 2026
Internet Archive copy of a UN 38.3 test report that Dyness hosted at dyness.com/Public/Uploads/uploadfile/files/20241207/UN38.3B4850.pdf, captured by the Internet Archive on March 6, 2026 and retrieved on September 25, 2026. dyness.com's robots.txt disallows that folder, so the file was not fetched from Dyness. The report was issued by CQC Intime Testing Technology Co., Ltd on 2020-05-15 to the applicant and manufacturer Daqin New Energy Tech(Taizhou)., Ltd.; it is a test report hosted by the brand, not an issuer directory record.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- B4850
Manufacturer SKU B4850 · US market
Observed Oct 15, 2026
EN 62619:2017: verified
Finished battery pack / module. TÜV Rheinland’s Certipedia record for certificate R 50464979 (EN 62619:2017; holder DAQIN NEW ENERGY TECH (TAIZHOU) CO., LTD.; date of issue 2020-04-27; model designation (1) B4850 to (5) Powerbox F-10.0), read on October 15, 2026, prints "Invalid Certificate" and "This certificate is no longer valid." It gives no date and no reason for that status. The EN 62619 certificate Dyness published is kept as the maker’s claim in its own row.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: 0.21-personal documented pct: 40 basis: nominal missing: Certificates evidence needed Warranty energy disclosure evidence needed Cell model disclosure evidence needed criteria: key: certificateEvidence label: Certificates value: 0 unit: evidence points shown: IEC 62040-1:2017 +2 shown detail: Research pending state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: CEC; UL 9540; UL 1973. display note: Unknown Sources: No source on record key: years label: Warranty term value: 7 unit: years shown: 7 years shown detail: Unknown state: documented points: 7 ceiling: 20 weight: 20 share: 35 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [4] key: throughputEvidence label: Warranty energy disclosure value: 0 unit: evidence points shown: 6.7 MWh · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 10 weight: 10 share: 0 covered: no missing: yes folded: no reason: Unknown reason text: Unknown note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment. display note: Unknown Sources: [4] key: lifetime label: Lifetime / capacity value: Unknown unit: MWh/kWh shown: 6,000 cycles shown detail: Unknown state: documented points: 4 ceiling: 20 weight: 20 share: Unknown covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh. display note: Unknown Sources: [3] key: cellDisclosure label: Cell model disclosure value: 0 unit: disclosure points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 5 weight: 5 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- Dyness B4850 product page (dyness.us, September 25, 2026 capture) (Dyness Digital Energy Technology Co., Ltd. · manufacturer · observed Sep 24, 2026)
- Dyness B4850 User Manual, Battery Module 48V/50Ah, file version 20230724-V2-EN (Internet Archive copy of March 5, 2026) (Internet Archive · archive · 20230724-V2-EN · observed Sep 24, 2026)
- Dyness B4850 low voltage battery page (Internet Archive copy of December 3, 2024) (Internet Archive · archive · observed Sep 24, 2026)
- Dyness Warranty Terms for Energy Storage Solutions, B4850, Limited Warranty (Australia), V2.0-202308 (Internet Archive copy of March 5, 2026) (Internet Archive · archive · V2.0-202308 · observed Sep 24, 2026)
- TÜV Rheinland Certipedia record for certificate R 50464979 (October 15, 2026 capture) (TÜV Rheinland · issuer · observed Oct 14, 2026)
- TUV Rheinland certificate R 50464979 (EN 62619:2017) for B4850 and Powerbox F models, hosted by Dyness (Internet Archive copy of March 5, 2026) (Internet Archive · archive · observed Sep 24, 2026)
- TUV Rheinland certificates of conformity to IEC 62040-1:2017 for B4850 and Powerbox F models, hosted by Dyness (Internet Archive copy of March 5, 2026) (Internet Archive · archive · observed Sep 24, 2026)
- UN 38.3 Test Report 20200406J05445, Energy Storage Module B4850 (CQC Intime Testing Technology), hosted by Dyness (Internet Archive copy of March 6, 2026) (Internet Archive · archive · 20200406J05445 · observed Sep 24, 2026)
Sign in to report an error on this page