About brandDuracell Power Center, whose site carries a Power Center copyright and whose datasheets give a San Jose, California address, sells home battery storage, hybrid inverters, microinverters and an EV charger under the Duracell trademark, which its site says is used under license from Duracell U.S. Operations, Inc. Its datasheets say the products are manufactured under license and warranty supported by Omega Green Power in San Jose.
SKU detail
locator: Manual cover and specification table
conditions: Model name printed on the operation manual and in its specification table; the Resources page links it as "DURA5 Manual".
6 AWG or larger yellow-green grounding cable; resistance from the battery grounding point to ground below 0.1 Ω
Printed as "Grounding cables shall be 6AWG or higher yellow-green cables."; "to ground connection point shall be less than 0.1Ω." in the Duracell Power Center DURA 5 Operation Manual (June 2024 file) (page 31, section 4.7 Ground Cable Connection).
Where: PDF page 31, section 4.7 Ground Cable Connection
Printed as "Power Cable Terminals: Power cables are water-proof and function the same no matter the color." in the Duracell Power Center DURA 5 Operation Manual (June 2024 file) (page 13, section 2.3 Equipment Interface Instruction, Power Terminals).
Where: PDF page 13, section 2.3 Equipment Interface Instruction, Power Terminals
Wall mounting or ground mounting (stacked on a base)
Printed as "4.4.1) Wall Mounting Reminder Choose suitable wall"; "4.4.2) Ground Mounting 1. Before installation" in the Duracell Power Center DURA 5 Operation Manual (June 2024 file) (pages 24, 25, sections 4.4.1 and 4.4.2).
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "4.13 Considerations with Multiple Battery Stacks" and "4.4.1) Wall Mounting". Classified as Stackable from the maker's own words for this model; the maker also prints wall or floor mounting, quoted here (PM decision, October 13, 2026: a unit printing both stacking words and wall or floor words is Stackable).
Printed as "Positive power cable, 4 awg, 8 ft (2.5m)" in the Duracell Power Center DURA 5 Operation Manual (June 2024 file) (page 17, section 4.1 Package List).
Printed as "DO NOT connect the batteries in series, only parallel" in the Duracell Power Center DURA 5 Operation Manual (June 2024 file) (page 28, section 4.5 Power Cable Connection).
Where: PDF page 28, section 4.5 Power Cable Connection
Printed as 4864 Wh, the third value after the model name (nominal voltage 51.2 V, nominal capacity 5120 Wh, usable capacity 4864 Wh, depth of discharge 95%).
Link Port: communication between parallel batteries; CAN: to the inverter (500 Kbps); RS485: to the inverter (9600 or 115200 bps); USB 2.0: service and upgrade; WIFI Port: Duracell Power Center WiFi block only
Printed as "For communication between multiple parallel batteries. 7. Link Port"; "500 Kbps. For connection to inverter 8. CAN"; "9600 or 115200 bps. For connection to inverter RS485"; "USB 2.0: Provided for the manufacturer or a professional engineer"; "Connect the WIFI block from Duracell Power Center ONLY." in the Duracell Power Center DURA 5 Operation Manual (June 2024 file) (page 12, section 2.3 Equipment Interface Instruction).
Where: PDF page 12, section 2.3 Equipment Interface Instruction
Printed as 0˚~50˚ Charge; the manual prints no unit, and the figures are recorded as degrees Celsius because the storage row and design-life row print 25˚ beside 77˚.
Recommended charge and discharge current. The next rows print a maximum of 100~120 A for 15 minutes and a peak of 120~200 A for 15 seconds; the footnote says derating depends on voltage, state of charge and temperature.
Where: Section 2.2 Specifications, "Recommend Charge/Discharge Current (A)*"
Printed as "500 Kbps. For connection to inverter 8. CAN"; "9600 or 115200 bps. For connection to inverter RS485" in the Duracell Power Center DURA 5 Operation Manual (June 2024 file) (page 12, section 2.3 Equipment Interface Instruction).
Where: PDF page 12, section 2.3 Equipment Interface Instruction
Printed as "ambient temperature is within 32º-122ºF (0-50ºC) for operation." in the Duracell Power Center DURA 5 Operation Manual (June 2024 file) (page 23, section 4.3.2 Plan the Installation Site).
Where: PDF page 23, section 4.3.2 Plan the Installation Site
37.74 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)395 × 579 × 165 mm / 15.6 × 22.8 × 6.5 in45 kg / 99 lb0.14 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
49/100Missing details65% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
48 V · Stackable · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
CertificatesCEC · UL1973 +2CEC listed45 / 45
100 evidence points · 45% weight
CEC listing: full credit for the certificate criterion. Exact model found in the dated CEC equipment list. This is not a safety certification or system approval. Applies: CEC; UL 9540; UL 1973.
Research pending, 0 points: Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Recorded exactly as the DURA 5 manual prints it in its Compliance row, "U1642", between UL1973 and UL9540A; the manual does not expand it and it is not interpreted here. No certificate number, certification body or file number is printed, and no issuer record was read.
Printed in the Compliance row of the DURA 5 manual's specification table. No certificate number, certification body or file number is printed, and no issuer record was read.
UL9540Amanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
DURA 5
Limitations
Printed in the Compliance row of the DURA 5 manual's specification table. UL 9540A is a test method; no test report, laboratory or date is printed, and no issuer record was read.
UL 1973authority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
DURA 5
Limitations
Listed on the California Energy Commission Battery List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Power Center "DURA 5": UL 1973, certifying entity TUV Rheinland of North America, certificate date 2023-08-25, Ed. 3 : 2022, CEC listing date 2024-01-11. A state equipment list entry, not the certification body's own record.
CECauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
DURA 5
Limitations
Model DURA 5 listed on the California Energy Commission Battery List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Power Center, as "DURA 5", CEC listing date 2024-01-11. This is an equipment listing, not UL certification or complete-system approval.
UL1973Manufacturer claim · equipment listingClaimedListed when checked
Printed in the Compliance row of the DURA 5 manual's specification table. No certificate number, certification body or file number is printed, and no issuer record was read.
U1642Manufacturer claim · equipment listingClaimedListed when checked
Recorded exactly as the DURA 5 manual prints it in its Compliance row, "U1642", between UL1973 and UL9540A; the manual does not expand it and it is not interpreted here. No certificate number, certification body or file number is printed, and no issuer record was read.
UL9540AManufacturer claim · equipment listingClaimedListed when checked
Printed in the Compliance row of the DURA 5 manual's specification table. UL 9540A is a test method; no test report, laboratory or date is printed, and no issuer record was read.
Forty-five page operation manual linked from the Resources page as the DURA5 Manual, archived on September 24, 2026. Its Section 2.2 specification table lists labels and values separately in the text layer; the values are read in the order of the labels. Its compliance row is a manufacturer claim, recorded exactly as printed, that no issuer record was read against.
Archived copies
Archived copy of a document published by Power Center (Duracell Power Center). Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Power Center, MA Series and M Series document lists
Retrieved Sep 23, 2026
Duracell Power Center Resources page, captured on September 24, 2026. It links the datasheets and manuals cited here (checked in the page markup) and prints no product figures.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Duracell Power Center DURA 5 Operation Manual (June 2024 file)
Archived copy of a document published by Power Center (Duracell Power Center). Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
DURA 5
Manufacturer SKU DURA 5 · US market
Observed Oct 11, 2026
UL 1973: claimed
Product / system scope unresolved. Listed on the California Energy Commission Battery List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Power Center "DURA 5": UL 1973, certifying entity TUV Rheinland of North America, certificate date 2023-08-25, Ed. 3 : 2022, CEC listing date 2024-01-11. A state equipment list entry, not the certification body's own record.
Product / system scope unresolved. Model DURA 5 listed on the California Energy Commission Battery List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Power Center, as "DURA 5", CEC listing date 2024-01-11. This is an equipment listing, not UL certification or complete-system approval.
note: CEC listing: full credit for the certificate criterion. Exact model found in the dated CEC equipment list. This is not a safety certification or system approval. Applies: CEC; UL 9540; UL 1973.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.