conditions: REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 prints the product code and no separate part number.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Frame
Anodized aluminum (black)
Printed in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017.
Read from the STC table, column 2 of 6 (245 W), of REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 25°C)". The header prints "electRical data @ stc Rec240pe blK Rec245pe blK Rec250pe blK Rec255pe blK Rec260pe blK Rec265pe blK" and the row prints "Nominal Power Current - IMPP (A) 8.17 8.23 8.30 8.42 8.50 8.58".
Where: Electrical data at STC, Nominal Power Current - IMPP row, column 2 of 6 (245 W)
Read from the STC table, column 2 of 6 (245 W), of REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 25°C)". The header prints "electRical data @ stc Rec240pe blK Rec245pe blK Rec250pe blK Rec255pe blK Rec260pe blK Rec265pe blK" and the row prints "Short Circuit Current - ISC (A) 8.75 8.80 8.86 8.95 9.01 9.08".
Where: Electrical data at STC, Short Circuit Current - ISC row, column 2 of 6 (245 W)
Read from the STC table, column 2 of 6 (245 W), of REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 25°C)". The header prints "electRical data @ stc Rec240pe blK Rec245pe blK Rec250pe blK Rec255pe blK Rec260pe blK Rec265pe blK" and the row prints "Nominal Power Voltage - VMPP (V) 29.7 30.1 30.2 30.5 30.7 30.9".
Where: Electrical data at STC, Nominal Power Voltage - VMPP row, column 2 of 6 (245 W)
Read from the STC table, column 2 of 6 (245 W), of REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 25°C)". The header prints "electRical data @ stc Rec240pe blK Rec245pe blK Rec250pe blK Rec255pe blK Rec260pe blK Rec265pe blK" and the row prints "Open Circuit Voltage - VOC (V) 36.8 37.1 37.4 37.6 37.8 38.1".
Where: Electrical data at STC, Open Circuit Voltage - VOC row, column 2 of 6 (245 W)
Cell description as printed ("Cell Type: 60 multi-crystalline 3 strings of 20 cells with bypass diodes ") in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017.
Suitable grounding lugs must be used.; Grounding cable size should be between 2.1 mm² - 21.2 mm².; Fix lug to the frame using a star washer and lock nut, ensuring a conductive connection (fig. 8).; Place the star washer between the frame and the nut, using a 5 mm diameter stainless steel bolt and locking nut to mount the lug to the panel frame and tighten according to the manufacturer’s recommended torque.
Printed as "suitable grounding lugs must be used." in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), section vii) Grounding. Where grounding is necessary. The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page.
Printed as "Weight: 18 kg" in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017; the metric figure is recorded.
Printed as "Cell Type: 60 multi-crystalline 3 strings of 20 cells with bypass diodes " in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017.
3.2 mm solar glass with anti-reflection surface treatment
Printed as "Glass: 3.2 mm solar glass with anti-reflection surface treatment" in REC Group's REC245PE BLK datasheet (REC Peak Energy BLK Series datasheet, international edition (Ref: NE-05-05-03-V. 03.16) (Internet Archive copy, May 17, 2017)), captured on September 28, 2026.
A framed glass module: REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 prints "Glass: 3.2 mm solar glass with anti-reflection surface treatment" and "Frame: Anodized aluminum (black) ".
Printed as "Maximum Wind Load: 244 kg/m² (2400 Pa)" in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017; recorded as the rear (uplift) load. The sheet does not say whether this is a test or a design load.
Printed as "Back Sheet: Double layer highly resistant polyester" in REC Group's REC245PE BLK datasheet (REC Peak Energy BLK Series datasheet, international edition (Ref: NE-05-05-03-V. 03.16) (Internet Archive copy, May 17, 2017)), captured on September 28, 2026.
Where: Datasheet page 2, GENERAL DATA, Backsheet row
W 991 × L 1,665 × D 38 mm / W 39 × L 65.55 × D 1.5 in converted
Printed as "Dimensions: 1665 x 991 x 38 mm" in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017; the metric figures are recorded.
Printed as "Maximum Snow Load: 550 kg/m² (5400 Pa)" in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017; recorded as the front (downward) load. The sheet does not say whether this is a test or a design load.
Read from the STC table, column 2 of 6 (245 W), of REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 25°C)". The table prints "electRical data @ stc Rec240pe blK Rec245pe blK Rec250pe blK Rec255pe blK Rec260pe blK Rec265pe blK" and "Nominal Power - PMPP (Wp) 240 245 250 255 260 265".
Where: Electrical data at STC, power row, column 2 of 6 (245 W)
Printed as "Max Series Fuse Rating: 25 A" in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017.
Clamping within the green zone (208 - 416 mm) is certified for design loads up to 5400 Pa (550 kg/m²); Clamping within the yellow zone (0 - 208 mm long side, 250 mm short side) is certifed for design loads up to 2400 Pa (244 kg/m²); Clamping within the red zone is not permitted (> 416 mm long side, > 250 mm short side) when only using four clamps; REC Peak Energy panels can also be secured to the mounting structure using the mounting holes (fig. 5) found on the underside of the frame (6.6 x 11 mm, spaced 450 mm from the midpoint of the long side).
Printed as "Clamping within the green zone (208 - 416 mm) is certified for design loads up to 5400 Pa (550 kg/m²)" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), Clamp mounting positions (Fig. 4) and Mounting holes. The panels can be fixed on both the long and the short side within the zones of Fig. 4 with a minimum of four clamps ("certifed" is as printed); slide-in systems meeting the same grip specifications are also permitted.
Where: PDF page 7, Clamp mounting positions (Fig. 4) and Mounting holes
The cables on REC Peak Energy panels have a minimum bending radius of 30 mm to avoid damage to the insulation (Fig. 9).
Printed as "the cables on REC Peak Energy panels have a minimum bending radius of 30 mm to avoid damage to the insulation (Fig. 9)." in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), Connections and connectors, Protecting the cables. The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page.
Where: PDF page 8, Connections and connectors, Protecting the cables
Printed as "Max series Fuse Rating 25 a" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, Maximum Ratings. One figure for the series (IEC edition); the string configuration instructions on PDF page 4 print the same 25 A. The UL 1703 edition of REC's 60-cell manual (Rev C.2 - 01.19) prints 15 A for the Peak Energy Series. The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page.
Where: PDF page 11, technical characteristics, Maximum Ratings
Printed as "Maximum system voltage 1000 v" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, Maximum Ratings. One figure for the series. The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, technical characteristics, Maximum Ratings
Read from the STC table, column 2 of 6 (245 W), of REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 25°C)". The header prints "electRical data @ stc Rec240pe blK Rec245pe blK Rec250pe blK Rec255pe blK Rec260pe blK Rec265pe blK" and the row prints "Module Efficiency (%) 14.5 14.8 15.2 15.5 15.8 16.1".
Where: Electrical data at STC, Module Efficiency row, column 2 of 6 (245 W)
Printed as "operational temperature -40 ... +85°C" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, Maximum Ratings. The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, technical characteristics, Maximum Ratings
Printed as "Temperature Coefficient of PMPP -0.4 %/°C" in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017.
Where: Temperature ratings, Temperature coefficient of PMPP
Printed as "Temperature Coefficient of ISC 0.024 %/°C" in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017.
Where: Temperature ratings, Temperature coefficient of ISC
Printed as "Temperature Coefficient of VOC -0.27 %/°C" in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017.
Where: Temperature ratings, Temperature coefficient of VOC
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from the STC table, column 2 of 6 (245 W), of REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 25°C)". The header prints "electRical data @ stc Rec240pe blK Rec245pe blK Rec250pe blK Rec255pe blK Rec260pe blK Rec265pe blK" and the row prints "Module Efficiency (%) 14.5 14.8 15.2 15.5 15.8 16.1".
REC's Limited Warranty Certificate for REC Peak Energy panels (REC Warranty Conditions, REC Peak Energy Products Rev L, valid as of January 1, 2017), which covers all panels with the REC Peak Energy name (excluding panels showing Q3) prints a product warranty "for a period of ten (10) years from the date of purchase by the Original End-User". Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
REC's Limited Warranty Certificate for REC Peak Energy panels (REC Warranty Conditions, REC Peak Energy Products Rev L, valid as of January 1, 2017), which covers all panels with the REC Peak Energy name (excluding panels showing Q3) prints a power output warranty to "the end of the 25th year, an actual output of at least 80.2%" of nameplate power. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
0.4 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "Temperature Coefficient of PMPP -0.4 %/°C" in REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
IEC 60068-2-68manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC245PE BLK
Limitations
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 60068-2-68 (Blowing Sand)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61215manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC245PE BLK
Limitations
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61701manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC245PE BLK
Limitations
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 61701 (Salt Mist - severity level 6)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61730manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC245PE BLK
Limitations
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62716manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC245PE BLK
Limitations
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 62716 (Ammonia Resistance)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" and "CERTIFICATE BBA 0044 MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
UL 1703manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC245PE BLK
Limitations
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
REC's Limited Warranty Certificate for REC Peak Energy panels (REC Warranty Conditions, REC Peak Energy Products Rev L, valid as of January 1, 2017), which covers all panels with the REC Peak Energy name (excluding panels showing Q3) prints a product warranty "for a period of ten (10) years from the date of purchase by the Original End-User". Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
REC's Limited Warranty Certificate for REC Peak Energy panels (REC Warranty Conditions, REC Peak Energy Products Rev L, valid as of January 1, 2017), which covers all panels with the REC Peak Energy name (excluding panels showing Q3) prints that the actual power output "will decline annually by no more than 0.7% for a period of 24 years". Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: English sections, II. Power Output Warranty
REC's Limited Warranty Certificate for REC Peak Energy panels (REC Warranty Conditions, REC Peak Energy Products Rev L, valid as of January 1, 2017), which covers all panels with the REC Peak Energy name (excluding panels showing Q3) prints a power output warranty to "the end of the 25th year, an actual output of at least 80.2%" of nameplate power. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: English sections, II. Power Output Warranty
Location: Cover page (scope) and PDF page 2 (revision)
Retrieved Oct 1, 2026
REC's own installation manual for its 60-cell panels certified to UL 1703, printed as Rev C.2 - 01.19 (Ref: NE-06-22). REC no longer publishes it; captured 1 October 2026 as the Internet Archive copy of April 24, 2019 of the file recgroup.com then served. Its cover names the REC Peak Energy and Peak Energy BLK, TwinPeak and TwinPeak BLK, TwinPeak 2 and TwinPeak 2 BLK, TwinPeak 2 BLK2 and TwinPeak 2 Mono series, and its Panel Characteristics section prints a technical sheet for the Peak Energy, TwinPeak, TwinPeak 2, TwinPeak 2 BLK2 and TwinPeak 2 Mono series. Later revisions of REC's combined manual that still named these series are not available as complete copies. Series-level instructions and the technical sheets as printed; manufacturer instructions, not independent tests.
IEC 61215Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61730Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
UL 1703Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
MCSManufacturer claim · equipment listingClaimedListed when checked
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" and "CERTIFICATE BBA 0044 MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62716Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 62716 (Ammonia Resistance)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61701Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 61701 (Salt Mist - severity level 6)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 60068-2-68Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16), Internet Archive copy of May 17, 2017 lists "IEC 60068-2-68 (Blowing Sand)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Electrical data at STC, temperature ratings, maximum ratings, mechanical data, general data, certification and warranty blocks
Retrieved Sep 24, 2026
Internet Archive copy, captured on May 17, 2017, of REC Group's own REC Peak Energy BLK Series datasheet (international edition, Ref: NE-05-05-03-V. 03.16) at https://www.recgroup.com/sites/default/files/documents/datasheet_rec_peak_energy_blk_rev_v_eng.pdf; not a live manufacturer document. REC's current site, checked on September 25, 2026, no longer offers it: REC's product downloads index lists no datasheet for the series. Electrical figures are read from the STC table only; the NOCT table is not recorded.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
REC's current limited warranty conditions for REC Peak Energy panels, linked from REC's Product Downloads page (Warranty); valid as of January 1, 2017. Manufacturer terms, not an independent test.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Location: Cover page and PDF page 3 (How to use this manual)
Retrieved Oct 1, 2026
REC's own installation manual for its Peak Energy Series panels certified to IEC 61215 / 61730, printed as Rev M - 06.15 (Ref: NE-06-03-M). REC no longer publishes it; captured 1 October 2026 as the Internet Archive copy of May 28, 2016 of the file recgroup.com then served. It covers all REC Peak Energy panels including variants with a black backsheet and/or a black frame, excluding 72-cell panels, and prints one technical sheet (235 to 270 Wp) for the series. Series-level instructions; manufacturer instructions, not independent tests.
REC Peak Energy BLK Series datasheet, international edition (Ref: NE-05-05-03-V. 03.16) (Internet Archive copy, May 17, 2017)
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
REC Warranty Conditions, REC Peak Energy Products, Rev L (Ref: NE259231231)