Electrical at STC

Rated output (STC)
245 W [1]
Module efficiency
14.8 % [1]
Voltage at max power (Vmp)
30.1 V [1]
Current at max power (Imp)
8.23 A [1]
Open-circuit voltage (Voc)
37.1 V [1]
Short-circuit current (Isc)
8.8 A [1]
Power tolerance
?

Temperature and system limits

Temperature coefficient, Pmax
-0.4 %/°C [1]
Temperature coefficient, Voc
-0.27 %/°C [1]
Temperature coefficient, Isc
0.024 %/°C [1]
Maximum system voltage
1,000 V [2] [1]
Maximum series fuse
25 A [2]
NOCT / NMOT
?
Rated output at NMOT
?
Operating temperature
-40 to 85 °C / -40 to 185 °F converted [2] [1]

Cells and construction

Cell technology
multi-crystalline [1]
Cell count
60 cells [1]
Bifacial
?
Bifaciality
?
Frame
Anodized aluminum (black) [1]
Front glass
3.2 mm solar glass with anti-reflection surface treatment [1]
Back cover
Double layer highly resistant polyester [1]
Panel format
rigid [1]

Mechanical and connections

Dimensions
W 991 × L 1,665 × D 38 mm / W 39 × L 65.55 × D 1.5 in converted [1]
Weight
18 kg / 40 lb converted [1]
Connectors
Multi-Contact MC4 (4 mm²) [1]
Cable length
?
Junction box rating
?
Mounting
?
Design load, front
?
Design load, rear
?

Installation (from the manual)

Conductors

Cable bending radius / connector notes
The cables on REC Peak Energy panels have a minimum bending radius of 30 mm to avoid damage to the insulation (Fig. 9). [2]

Clearances and orientation

Mounting methods and clamp zones
Clamping within the green zone (208 - 416 mm) is certified for design loads up to 5400 Pa (550 kg/m²); Clamping within the yellow zone (0 - 208 mm long side, 250 mm short side) is certifed for design loads up to 2400 Pa (244 kg/m²); Clamping within the red zone is not permitted (> 416 mm long side, > 250 mm short side) when only using four clamps; REC Peak Energy panels can also be secured to the mounting structure using the mounting holes (fig. 5) found on the underside of the frame (6.6 x 11 mm, spaced 450 mm from the midpoint of the long side). [2]

Grounding

Grounding
Suitable grounding lugs must be used.; Grounding cable size should be between 2.1 mm² - 21.2 mm².; Fix lug to the frame using a star washer and lock nut, ensuring a conductive connection (fig. 8).; Place the star washer between the frame and the nut, using a 5 mm diameter stainless steel bolt and locking nut to mount the lug to the panel frame and tighten according to the manufacturer’s recommended torque. [2]

Not in the manual: Torque

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

REC Group REC245PE BLK · REC245PE BLK

Warranty

Product warranty10 years[3]
Power warranty term25 years[3]
First-year degradation?
Annual degradation after year one0.7 %[3]
Warranted final output?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?

Certifications and listings

UL 61730?
UL 1703Claimed present at observation [1]
IEC 61215Claimed present at observation [1]
IEC 61730Claimed present at observation [1]
IEC 62804?
CEC listing?
IEC 60068-2-68Claimed present at observation [1]
IEC 61701Claimed present at observation [1]
IEC 62716Claimed present at observation [1]
MCSClaimed present at observation [1]

Documents and sources

  1. REC Peak Energy BLK Series datasheet, international edition (Ref: NE-05-05-03-V. 03.16) (Internet Archive copy, May 17, 2017) Manufacturer datasheet (Internet Archive copy) · Revision Ref: NE-05-05-03-V. 03.16 · Checked Sep 24, 2026 https://web.archive.org/web/20170517131909id_/http://www.recgroup.com:80/sites/default/files/documents/datasheet_rec_peak_energy_blk_rev_v_eng.pdf
  2. REC Installation Manual, REC Peak Energy Series (IEC 61215/61730 edition, Rev M, 06.15), Internet Archive copy of May 28, 2016 Installation manual (Internet Archive copy) · Revision Rev M · Revised 2015-06 · Checked Oct 1, 2026 https://web.archive.org/web/20160528050558id_/http://www.recgroup.com:80/sites/default/files/documents/rec_peak_energy_installation_manual_iec_eng.pdf
  3. REC Warranty Conditions, REC Peak Energy Products, Rev L (Ref: NE259231231) Manufacturer warranty · Revision Rev L · Checked Oct 17, 2026 https://www.recgroup.com/sites/default/files/documents/warranty_rec_peak_energy_rev_l_web.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/panels/rec-group-rec245pe-blkSome links pay us a commission. That does not affect what we record.