Installed 10 of these last month. Have two strings of 5 connected in parallel to my Solark 15k inverter. I have already seen output spikes well over the peak rated 4600w for the strings. I have seen a few 5000+ watt peaks with a steady output of 4200+ during typical clear sky conditions here in Hawaii. My roof sees peak performance during spring/fall months due to its pitch. So far I am very happy with these panels, despite their large format they were not too difficult to install solo. I purchased the panels thru a local supplier, although I did get an estimate from NAZ solar that was comparable minus the shipping to Hawaii.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Greentech Renewables's product image of the REC Alpha Pure-RX 460W on its own store listing. The page uses this image for more than one size or version.REC Alpha Pure-RX 460W
Key specs
All specifications
No spec by that name.
Show all 31 specifications
Identity
| Field | Value | Conditions | Source |
|---|---|---|---|
| Frame | Anodized aluminum (Black) | REC Alpha Pure-RX domestic-content datasheet, printed value for this watt class. Where: Page 2, General Data, "Frame" | [2] |
| Current at max power | 8.38 A | Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "460"; printed "Nominal Power Current - IMPP(A) 8.29 8.38 8.49". Under STC (1000 W/m², 25°C, AM 1.5), front side. REC prints the same electrical columns in its US Pure-RX datasheet and its domestic-content Pure-RX-DC datasheet, so the -DC and the plain model carry identical figures. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source. Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "460", row beginning "Nominal Power Current -" | [2] [3] |
| Short-circuit current | 8.88 A | Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "460"; printed "Short Circuit Current - ISC (A) 8.81 8.88 8.95". Under STC (1000 W/m², 25°C, AM 1.5), front side. REC prints the same electrical columns in its US Pure-RX datasheet and its domestic-content Pure-RX-DC datasheet, so the -DC and the plain model carry identical figures. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source. Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "460", row beginning "Short Circuit Current -" | [2] [3] |
| Voltage at max power | 54.9 V | Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "460"; printed "Nominal Power Voltage - VMPP(V) 54.3 54.9 55.4". Under STC (1000 W/m², 25°C, AM 1.5), front side. REC prints the same electrical columns in its US Pure-RX datasheet and its domestic-content Pure-RX-DC datasheet, so the -DC and the plain model carry identical figures. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source. Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "460", row beginning "Nominal Power Voltage -" | [2] [3] |
| Open-circuit voltage | 65.7 V | Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "460"; printed "Open Circuit Voltage - VOC (V) 65.6 65.7 65.7". Under STC (1000 W/m², 25°C, AM 1.5), front side. REC prints the same electrical columns in its US Pure-RX datasheet and its domestic-content Pure-RX-DC datasheet, so the -DC and the plain model carry identical figures. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source. Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "460", row beginning "Open Circuit Voltage -" | [2] [3] |
| Bifacial | yes | Datasheet prints "Cell Type 88 half-cut bifacial REC heterojunction cells, with gapless technology". Covers product code RECXXXAA PURE-RX-DC in the 450-470 W classes, which includes this model. Where: Page 2, General Data, Cell Type | [2] |
| Cell type | HJT Provisional | Seller-listed specification; not independently verified. Where: technology | [4] |
| Grounding | Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL-4DBT (tin plated) (E34440),; Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2 mm²),; Attach grounds to the grounding holes in the panel frames,Fix lug to the frame using a star washer (#10) and lock nut (#10), ensuring a conductive connection | Printed as "Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL-4DBT (tin plated) (E34440)," in REC's Alpha Pure panels installation manual (UL edition, Rev 18, 3.2026), Grounding section (bulleted instructions) and Fig. 1-6. Fig. 1-6 prints the wire fastening torque for the lug by wire size. Where: PDF page 11, Grounding section (bulleted instructions) and Fig. 1-6 | [5] |
| Weight | 22.7 kg / 50 lb converted | Printed as "Weight 50.0 lb / 22.7 kg" in REC Alpha Pure-RX domestic-content datasheet (UL), Datasheet, general data table, Weight row. Revised on 1 October 2026: The REC datasheet prints "50.0 lb / 22.7 kg" for every watt class in this series. Where: Datasheet, general data table, Weight row | [2] [3] |
| Cell count | 88 cells | REC Alpha Pure-RX domestic-content datasheet, printed value for this watt class. Where: Page 2, General Data, "Cell Type" (88 half-cut cells) | [2] |
| Connectors | Stäubli MC4 PV-KBT4/KST4 (12 AWG) | REC Alpha Pure-RX domestic-content datasheet, printed value for this watt class. Where: Page 2, General Data, "Connectors" | [2] |
| Front glass | 0.13 in solar glass with anti-reflective surface treatment in accordance with EN12150 | Printed as "Glass 0.13 in solar glass with anti-reflective surface treatment in accordance with EN12150" in REC Group's REC460AA PURE-RX-DC datasheet (REC Alpha Pure-RX domestic-content datasheet (UL)), captured on September 28, 2026. Where: Datasheet page 2, GENERAL DATA, Glass row | [2] |
| Clamp torque | 12 to 25 N·m | Printed as "Torque 12 - 25 N-m / 106 - 221 lb-in" in REC's Alpha Pure panels installation manual (UL edition, Rev 18, 3.2026), Securing of panels, Fig. 1-1 (clamp specifications). The clamp torque, printed as a range in two units; the first printed unit (N-m) is the value. The same 12 - 25 N-m is required for mounting-hole fixings (PDF page 10). Where: PDF page 9, Securing of panels, Fig. 1-1 (clamp specifications) | [5] |
| Junction box | 4-part, 4 bypass diodes, IP68 rated (IEC 62790:2020) | REC Alpha Pure-RX domestic-content datasheet, printed value for this watt class. Where: Page 2, General Data, "Junction Box" | [2] |
| Rear load pa | 4,000 Pa | Printed as "Rear (4-Point)* -4000 Pa (84 lbs/ft²)" in REC Alpha Pure-RX domestic-content datasheet (UL), Page 2, Maximum test load, Rear (4-Point). Revised on 1 October 2026: The datasheet prints the rear 4-point maximum test load as -4000 Pa, recorded as a magnitude. Where: Page 2, Maximum test load, Rear (4-Point) | [2] |
| Rear surface | Highly resistant polymer (Black) | Printed as "Backsheet Highly resistant polymer (Black)" in REC Group's REC460AA PURE-RX-DC datasheet (REC Alpha Pure-RX domestic-content datasheet (UL)), captured on September 28, 2026. Where: Datasheet page 2, GENERAL DATA, Backsheet row | [2] |
| Dimensions | W 1,205 × H 1,728 × D 30 mm / W 47.44 × H 68.03 × D 1.2 in converted | Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC; printed "Dimensions 68.0 x 47.4 x 1.2 in (22.4 ft²) / 1728 x 1205 x 30 mm (2.08 m²) Weight 50.0 lb / 22.7 kg". General data table, one size for every watt class. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source. Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), row beginning "Dimensions 68.0 x 47.4" | [2] [3] |
| Front load pa | 7,000 Pa | REC Alpha Pure-RX domestic-content datasheet, printed value for this watt class. Where: Page 2, Maximum Test Load, Front (4-Point) | [2] |
| Rated power | 460 W | Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "460"; printed "Power Output - PMAX (WP) 450 460 470". Nameplate power at STC, watt class sorting 0/+10 W. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source. Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "460", row beginning "Power Output - PMAX" | [2] [3] |
| Series fuse | 25 A | Printed as "Max Series Fuse Rating 25 A" in REC Alpha Pure-RX domestic-content datasheet (UL), Datasheet, maximum ratings table, "Max Series Fuse Rating" row. Revised on 1 October 2026: The REC datasheet prints "Max Series Fuse Rating 25 A" for every watt class in this series. Where: Datasheet, maximum ratings table, "Max Series Fuse Rating" row | [2] |
| Mounting methods | The panel must be secured, e.g., clamped, at least once in each of the four marked zones shown below (fig. 1-2).; Such installations have been found to be in compliance with IEC 61215 & IEC 61730 requirements for the maximum test loads of +7000 Pa downwards pressure and -4000 Pa upwards pressure (+4,667 Pa/-2,667 Pa design loads); 16.1 - 20.5 in 410 - 520 mm +1800 Pa / -1800 Pa* +1200 Pa / -1200 Pa +6200 Pa / -3000 Pa +3000 Pa / -2000 Pa +7000 Pa / -4000 Pa +4666 Pa / -2666 Pa; The REC solar panels covered by this manual can be installed utilizing the mounting holes (11 mm x 6.6 mm (0.43 in x 0.26in)) on the underside of the panel (fig. 1-4). | Printed as "The panel must be secured, e.g., clamped, at least once in each of the four marked zones shown below (fig. 1-2)." in REC's Alpha Pure panels installation manual (UL edition, Rev 18, 3.2026), Installation of REC Alpha Pure-RX Series panels, continuous rails parallel to the short side (Fig. 3-3), with PDF page 9 (Securing of panels) and PDF page 10 (Mounting holes). The third line is the long side clamping zone row of the REC Alpha Pure-RX table with the highest loads, as printed: test load then design load for clearance gaps of 0.8 - 1.6 in, 1.6 - 2.4 in and >2.4 in; loads marked * were evaluated by REC's internal testing, not certified. Other zones, rails parallel to the long side, short rails and six-point mounting for the REC Alpha Pure-RX (PDF pages 29 to 32) print other loads. The first, second and fourth lines are from PDF pages 9 and 10. Where: PDF page 28, Installation of REC Alpha Pure-RX Series panels, continuous rails parallel to the short side (Fig. 3-3), with PDF page 9 (Securing of panels) and PDF page 10 (Mounting holes) | [5] |
| Cable bend radius | The cables must have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation (fig. 1-7), | Printed as "The cables must have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation (fig. 1-7)," in REC's Alpha Pure panels installation manual (UL edition, Rev 18, 3.2026), Cable management. Where: PDF page 12, Cable management | [5] |
| Max system voltage | 1,000 V | Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC; printed "System Voltage 1000 V Max Series Fuse Rating 25 A". Module ratings table, one value for every watt class. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), row beginning "System Voltage 1000 V" | [2] [4] |
| Module efficiency | 22.1 % | Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "460"; printed "Panel Efficiency (%) 21.6 22.1 22.6". Panel efficiency at STC. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "460", row beginning "Panel Efficiency (%) 21.6" | [2] [4] |
| Temperature coefficient | -0.24 %/°C | Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC; printed "TEMPERATURE COEFFICIENT* PMAX -0.24%/°C". Temperature coefficient of PMAX, one value for every watt class; REC notes the coefficients are linear values. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), row beginning "TEMPERATURE COEFFICIENT* PMAX -0.24%/°C" | [2] [4] |
| Isc temperature coefficient | 0.04 %/°C | REC Alpha Pure-RX domestic-content datasheet, printed value for this watt class. Where: Page 2, Temperature Coefficient, ISC | [2] |
| Voc temperature coefficient | -0.24 %/°C | REC Alpha Pure-RX domestic-content datasheet, printed value for this watt class. Where: Page 2, Temperature Coefficient, VOC | [2] |
Owner reviews
Sellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Rated output
- 460 WEfficiency 22.1 %W / sq ft 20.5* (Calculated: 460 W ÷ (1,728 mm × 1,205 mm = 22.41 sq ft) = 20.5 W/sq ft)
- Voltage (STC)
- 54.9 VVmp · maximum powerVoc · open circuit 65.7 VMax system 1,000 V
- Current (STC)
- 8.38 AImp · maximum powerIsc · short circuit 8.88 A
- Dimensions
- W: 1,205 × H: 1,728 × D: 30 mm / W: 47.44 × H: 68.03 × D: 1.2 inWeight 22.7 kg / 50 lb
- Warranty
- 20 yearsPower warranty 25 years
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
22.1 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "460"; printed "Panel Efficiency (%) 21.6 22.1 22.6". Panel efficiency at STC. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
20 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module
Standard product warranty. Eligible REC-certified installer installations can qualify for 25 years; system-size and registration conditions apply.
25 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A460-MCE54Db 460W Dual-Glass Module
0.24 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC; printed "TEMPERATURE COEFFICIENT* PMAX -0.24%/°C". Temperature coefficient of PMAX, one value for every watt class; REC notes the coefficients are linear values. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
0.04935 against 0.01227 kg per W, the lowest documented for a solar panel (calculated from maker figures): Go Power! 110-Watt Solar Flex™ Module
22.7 kg / 460 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.
Not documented, 0 points: First-year degradation.
Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4
How it worksCertificates
A green check means we found this model, with that standard, on the certifier's own listing, the test lab's own report, or the California Energy Commission's equipment list.
UL 61730authority listing reportedlisted as of snapshot[6]
- Scope
- equipment listing
- Covered models
- REC460AA PURE-RX-DC
- Limitations
- Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC460AA Pure-RX-DC": UL 61730, certifying entity not printed on the list, CEC listing date 2026-03-11. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Mar 11, 2026Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [6]
CECauthority listing reportedlisted as of snapshot[6]
- Scope
- equipment listing
- Covered models
- REC460AA PURE-RX-DC
- Limitations
- Model REC460AA PURE-RX-DC listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC460AA Pure-RX-DC", CEC listing date 2026-03-11. The list prints "REC460AA Pure-RX-DC"; the record's model "REC460AA PURE-RX-DC" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.
- Record detail
- Issued: Not statedValid from: Mar 11, 2026Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [6]
IEC 61215manufacturer claimunknown[1]
- Scope
- equipment listing
- Covered models
- REC460AA PURE-RX-DC
- Limitations
- Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 8, 2026
- Source
- [1]
IEC 61730manufacturer claimunknown[1]
- Scope
- equipment listing
- Covered models
- REC460AA PURE-RX-DC
- Limitations
- Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 8, 2026
- Source
- [1]
UL 61730manufacturer claimunknown[1]
- Scope
- equipment listing
- Covered models
- REC460AA PURE-RX-DC
- Limitations
- Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 8, 2026
- Source
- [1]
Warranty
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- REC Alpha Pure Panels Installation Manual (UL edition, English), Rev 18, 3.2026Open
Source details
Archived copy captured on 2026-09-28.
Location: Cover page (series scope)
Retrieved Sep 28, 2026
REC Group's own installation manual, captured September 28, 2026 with scripts/research/fetch.mjs from recgroup.com. UL 61730 edition, REF: PM-IM-23-06 REV: 18 UL EN 3.2026. Its cover states it is for all Alpha Pure solar panels certified to IEC 61215 & UL 61730 and names REC Alpha Pure 2, REC Alpha Pure-R and REC Alpha Pure-RX. It is a series-level manual: it establishes installation, handling, mounting and safety instructions for those series, not model-specific ratings. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 18.44 MBArchived copy, unaltered, kept as a record of what REC Group published. Original address: https://www.recgroup.com/sites/default/files/2025-01/IM_RECAlpha_UL_EN.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: a82dd1f99ea2b24b7608e129300fa1d7323282a66b813719a43dcd84580e1853
Datasheets
- REC Alpha Pure-RX US datasheetOpen
Certificate & compliance claims (3)
UL 61730Manufacturer claim · equipment listingClaimedStatus unconfirmed
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Manufacturer document
Official datasheet: REC Alpha Pure-RX US datasheetIEC 61215Manufacturer claim · equipment listingClaimedStatus unconfirmed
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Manufacturer document
Official datasheet: REC Alpha Pure-RX US datasheetIEC 61730Manufacturer claim · equipment listingClaimedStatus unconfirmed
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Manufacturer document
Official datasheet: REC Alpha Pure-RX US datasheetSource details
Manufacturer specification, not an independent test.
Location: Printed model column and specification table
Retrieved Sep 8, 2026
SHA-256: f11ba3f3a0895e8d9bb0ee058d60daaf9117261a4d05a019b77f32606ca83b04
Other documents
- REC 460W 88 Half-Cell HJT 1000V BLK/BLK Solar Panel w/Domestic Contents, REC460AA PURE-RX-DCOpen
Source details
Location: Product listing
Retrieved Sep 16, 2026
Archive and older revisions
Archive and older revisions3
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
- REC Alpha Pure-RX domestic-content datasheet (UL)Open
Source details
Location: Page 2, Electrical Data / General Data / Module Ratings
Retrieved Sep 19, 2026
Covers product code RECXXXAA PURE-RX-DC in the 450-470 W classes only; identical electrical table to the standard Pure-RX sheet but a separate domestic-content assembly.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 0.81 MBArchived copy, unaltered, kept as a record of what REC Group published. Original address: https://www.recgroup.com/sites/default/files/2026-03/DS_Alpha_Pure-RX_UL%20DC.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 4f4f121194d8508dc1b0e4f3fa2338118435a9e3483dc3fba45994948c47875d
- REC Group REC460AA PURE-RX-DC datasheetOpen
Source details
Location: Seller-linked document
Retrieved Sep 16, 2026
Manufacturer document mirrored by distributor; exact model and power column checked.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 0.81 MBArchived copy, unaltered, kept as a record of what REC Group published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ3058/00000/ZZ305800074_DS.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: cfc51d6820647b6421149d0fd5ed4731fedaef3275c0c1e8a4a145ff7c374b46
- REC Alpha Pure-RX product page (US)Open
Source details
Location: Product page body and Downloads list
Retrieved Sep 19, 2026
Marketing product page for the series; it links the US datasheet but publishes no per-watt-class electrical table itself.
Archived documents
REC Group REC460AA PURE-RX-DC datasheet
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what REC Group published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ3058/00000/ZZ305800074_DS.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: cfc51d6820647b6421149d0fd5ed4731fedaef3275c0c1e8a4a145ff7c374b46
REC Alpha Pure-RX domestic-content datasheet (UL)
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what REC Group published. Original address: https://www.recgroup.com/sites/default/files/2026-03/DS_Alpha_Pure-RX_UL%20DC.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 4f4f121194d8508dc1b0e4f3fa2338118435a9e3483dc3fba45994948c47875d
REC Alpha Pure Panels Installation Manual (UL edition, English), Rev 18, 3.2026
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what REC Group published. Original address: https://www.recgroup.com/sites/default/files/2025-01/IM_RECAlpha_UL_EN.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: a82dd1f99ea2b24b7608e129300fa1d7323282a66b813719a43dcd84580e1853
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- REC460AA PURE-RX-DC
Manufacturer SKU REC460AA PURE-RX-DC
Observed Oct 11, 2026
UL 61730: claimed
Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC460AA Pure-RX-DC": UL 61730, certifying entity not printed on the list, CEC listing date 2026-03-11. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model REC460AA PURE-RX-DC listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC460AA Pure-RX-DC", CEC listing date 2026-03-11. The list prints "REC460AA Pure-RX-DC"; the record's model "REC460AA PURE-RX-DC" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.
Observed Sep 8, 2026
UL 61730: claimed
Product / system scope unresolved. Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Observed Sep 8, 2026
IEC 61215: claimed
Product / system scope unresolved. Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Observed Sep 8, 2026
IEC 61730: claimed
Product / system scope unresolved. Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: panels-0.4-personal documented pct: 84 basis: Unknown missing: First-year degradation needed criteria: key: efficiency label: Module efficiency value: 22.1 unit: Unknown shown: 22.1 % shown detail: Unknown state: documented points: 22.5 ceiling: 26 weight: 26 share: 86.7 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown key: warranty label: Product warranty value: 20 unit: Unknown shown: 20 years shown detail: Unknown state: documented points: 14 ceiling: 21 weight: 21 share: 66.7 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: performanceWarranty label: Power warranty value: 25 unit: Unknown shown: 25 years shown detail: Unknown state: documented points: 13.3 ceiling: 16 weight: 16 share: 83.3 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: powerTemperature label: Power temperature coefficient value: 0.24 unit: Unknown shown: -0.24 %/°C shown detail: Unknown state: documented points: 14.7 ceiling: 16 weight: 16 share: 91.7 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown key: degradation label: First-year degradation value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: weightPerWatt label: Weight / watt value: 0.0493 unit: Unknown shown: 22.7 kg / 460 W shown detail: Unknown state: documented points: 1.2 ceiling: 5 weight: 5 share: 24.9 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: 22.7 kg / 460 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel. display note: Unknown | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- REC Alpha Pure-RX US datasheet (REC Group · manufacturer · observed Sep 8, 2026)
- REC Alpha Pure-RX domestic-content datasheet (UL) (REC Group · manufacturer · UL EN 6.2026 V7 REF: PM-DS-12-06/08.04.08.01 · observed Sep 19, 2026)
- REC Group REC460AA PURE-RX-DC datasheet (REC Group · manufacturer · observed Sep 16, 2026)
- REC 460W 88 Half-Cell HJT 1000V BLK/BLK Solar Panel w/Domestic Contents, REC460AA PURE-RX-DC (Greentech Renewables · seller · observed Sep 16, 2026)
- REC Alpha Pure Panels Installation Manual (UL edition, English), Rev 18, 3.2026 (REC Group · manufacturer · observed Sep 28, 2026)
- CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
Sign in to report an error on this page
Similar products
All with a priceACOPOWER 100W 12V Mono Solar Panel
ACOPOWER 100W 12V Slim Solar Panel HY100-12MBS
ACOPOWER 100W N-Type Bifacial Solar Panel
ACOPOWER 10W 12V Mono Solar Panel
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.