Charged Reviews · Quick reference
REC Alpha Pure-RX 460W
- Brand
- REC Group
- Model
- REC460AA PURE-RX-DC
- SKU / part number
- REC460AA PURE-RX-DC [1]
- Category
- Solar panels
chargedreviews.com/panels/rec-alpha-pure-rx-460w-rec460aa-pure-rx-dc
Electrical at STC
- Power tolerance
- ?
Temperature and system limits
Cells and construction
Mechanical and connections
- Connectors
- Stäubli MC4 PV-KBT4/KST4 (12 AWG) [2]
- Cable length
- ?
- Junction box rating
- ?
- Mounting
- ?
- Design load, front
- ?
- Design load, rear
- ?
Installation (from the manual)
Torque
- Clamp or bolt torque
- 12 to 25 N·m [5]
Conductors
- Cable bending radius / connector notes
- The cables must have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation (fig. 1-7), [5]
Clearances and orientation
- Mounting methods and clamp zones
- The panel must be secured, e.g., clamped, at least once in each of the four marked zones shown below (fig. 1-2).; Such installations have been found to be in compliance with IEC 61215 & IEC 61730 requirements for the maximum test loads of +7000 Pa downwards pressure and -4000 Pa upwards pressure (+4,667 Pa/-2,667 Pa design loads); 16.1 - 20.5 in 410 - 520 mm +1800 Pa / -1800 Pa* +1200 Pa / -1200 Pa +6200 Pa / -3000 Pa +3000 Pa / -2000 Pa +7000 Pa / -4000 Pa +4666 Pa / -2666 Pa; The REC solar panels covered by this manual can be installed utilizing the mounting holes (11 mm x 6.6 mm (0.43 in x 0.26in)) on the underside of the panel (fig. 1-4). [5]
Grounding
- Grounding
- Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL-4DBT (tin plated) (E34440),; Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2 mm²),; Attach grounds to the grounding holes in the panel frames,Fix lug to the frame using a star washer (#10) and lock nut (#10), ensuring a conductive connection [5]