conditions: Panasonic prints the model number VBHN330KA03E in its datasheet model rows and on its product pages, and no separate SKU or part number.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Current at max power
5.55 A
Printed as "VBHN330KA03E 96 330 59.5 5.55 71.2 5.99" in the DC Electrical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21): the VBHN330KA03E column lists Cell Number in Series, Rated Power, Vpm, Ipm, Voc and Isc in that order, so its Maximum Power Current (Ipm) is 5.55. The table note reads "*This specification shows the characteristics of the PV module not via the microinverter."
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Maximum Power Current (Ipm) row, VBHN330KA03E column
Printed as "VBHN330KA03E 96 330 59.5 5.55 71.2 5.99" in the DC Electrical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21): the VBHN330KA03E column lists Cell Number in Series, Rated Power, Vpm, Ipm, Voc and Isc in that order, so its Short Circuit Current (Isc) is 5.99. The table note reads "*This specification shows the characteristics of the PV module not via the microinverter."
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Short Circuit Current (Isc) row, VBHN330KA03E column
Printed as "VBHN330KA03E 96 330 59.5 5.55 71.2 5.99" in the DC Electrical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21): the VBHN330KA03E column lists Cell Number in Series, Rated Power, Vpm, Ipm, Voc and Isc in that order, so its Maximum Power Voltage (Vpm) is 59.5. The table note reads "*This specification shows the characteristics of the PV module not via the microinverter."
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Maximum Power Voltage (Vpm) row, VBHN330KA03E column
Printed as "VBHN330KA03E 96 330 59.5 5.55 71.2 5.99" in the DC Electrical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21): the VBHN330KA03E column lists Cell Number in Series, Rated Power, Vpm, Ipm, Voc and Isc in that order, so its Open Circuit Voltage (Voc) is 71.2. The table note reads "*This specification shows the characteristics of the PV module not via the microinverter."
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Open Circuit Voltage (Voc) row, VBHN330KA03E column
Printed as "Silicon hetero-junction**" in the Cell Type row of the DC Electrical Specifications of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21), with the footnote "Silicon hetero-junction**: Mono crystalline silicon/amorphous silicon hetero-junction."
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Cell Type row
Each ledge on the module frame has two larger holes for bolts (0.205’‘diameter (5.2 mm)).; Star washers must be used to make contact through the anodization of the module for this method.; Recommended torque value in tightening bolt and nut is 2.3 N.m (20in-lb).; Use Tyco Electronics 1954381-2 as grounding clip.
Printed as "Each ledge on the module frame has two larger holes for bolts (0.205’‘diameter (5.2 mm))." (PDF page 18), "Star washers must be used to make contact through the anodization of the module for this method." and "Recommended torque value in tightening bolt and nut is 2.3 N.m (20in-lb)." (PDF page 19) and "Use Tyco Electronics 1954381-2 as grounding clip." (PDF page 21) in Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21); statements for all the models it covers.
Where: PDF pages 18, 19 and 21, Earth Ground Wiring and Grounding Methods
Printed as "Length, mm (inches) 1590 (62.60) Width, mm (inches) 1053 (41.46) Frame Depth, mm (inches) 40 (1.57) Weight, kg (pounds) 19.5 (42.99)" in the Mechanical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21), one set for all four AC models; the weight reads 19.5 kg (42.99 pounds). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1-1, Mechanical Specifications, Weight row
Printed as "Recommendation of bolt torque: 10 ft-lbs." in the Module Installation section of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21) (printed unit spelling "ft-lbs"), for bolt and nut mounting; the IronRidge clamps the module was tested with list "Torque: 9.04 N.m (80 in-lbs)." A statement for all the models it covers.
W 1,053 × L 1,590 × D 40 mm / W 41.46 × L 62.6 × D 1.6 in converted
Printed as "Length, mm (inches) 1590 (62.60) Width, mm (inches) 1053 (41.46) Frame Depth, mm (inches) 40 (1.57) Weight, kg (pounds) 19.5 (42.99)" in the Mechanical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21), one set printed for "VBHN340SA17E, VBHN330SA17E VBHN330KA03E, VBHN325KA03E". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1-1, Mechanical Specifications
Printed as "VBHN330KA03E 96 330 59.5 5.55 71.2 5.99" in the DC Electrical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21): the VBHN330KA03E column lists Cell Number in Series, Rated Power, Vpm, Ipm, Voc and Isc in that order, so its Rated Power, Watts (Pmax) is 330. The table note reads "*This specification shows the characteristics of the PV module not via the microinverter." Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Rated Power, Watts (Pmax) row, VBHN330KA03E column
The modules should be mounted at the four (4) quarter points by the means shown in Figure 1.; 1) Positive load with Long frame mounting ・ 33 psf (0-450mm range from edge) ・ 75 psf (230-380mm range from edge); 2) Negative load with Long frame mounting ・ 33 psf (0-450mm range from edge) ・ 61 psf(230-380mm range from edge) ・ 75 psf (230-345mm range from edge); 3) Positive load with Short frame mounting ・ 33 psf (0-250mm range from edge); 4) Negative load with Short frame mounting ・ 33 psf (0-250mm range from edge)
Printed as "The modules should be mounted at the four (4) quarter points by the means shown in Figure 1." and the four UL Certified Load Ratings items quoted in the value, under Mechanical Loading in Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21); Table 1-2 (PDF page 5) prints the Load Resistance per mounting range with "Note) Load Resistance shown above is UL Test-Load. Design load is a value obtained by multiplying the above value by two thirds." Loads vary by mounting range, so no single front or rear load is recorded.
make sure the minimum bending radius of the cable is 30 mm or more.
Printed as "make sure the minimum bending radius of the cable is 30 mm or more." in the Wiring section of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21), about fixing the cable to the stand; a statement for all the models it covers.
Printed as "Module Efficiency 19.7%" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), read on September 25, 2026.
Where: DC Electrical Specifications, Module Efficiency
Printed as "The operat- ing temperature of DC module without Microinverter is –18°C (-2°F) to 85°C (185° F)." under Operating Conditions in Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21), for the DC module without the microinverter; the same item says "The Operating ambient temperature range must be within –18°C (-2°F) to 60°C (140°F) for VBHN330KA03E." Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 7, Installation, Operating Conditions
CEC; UL Listed as PV Rapid Shut Down Equipment; NEC-2014 and NEC-2017 section 690.12; C22.1-2015 Rule 64-218
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, UL 1741, CEC" and "This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems". The standards on these lines are recorded as certification claims; CEC is a listing and the electrical code references are conformance statements, with no certificate number, scope or issuer. Read on September 25, 2026.
Where: AC Electrical Specifications, Compliance; Safety & Rating Certifications; Features
Printed as "Temperature Coefficient (Pmax) -0.258%/°C" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), read on September 25, 2026.
Where: DC Electrical Specifications, Temperature Coefficient (Pmax)
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Printed as "Module Efficiency 19.7%" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), read on September 25, 2026.
Printed as "Limited Warranty Module and Microinverter: 25** Yrs Workmanship, Materials and Power Output (Linear)***" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), covering the module and microinverter. Footnote ** reads "** Equipment must be installed by Panasonic Authorized or Premium installer and registered through our website www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five (25) year product and labor". Read on September 25, 2026.
Printed as "Limited Warranty Module and Microinverter: 25** Yrs Workmanship, Materials and Power Output (Linear)***" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), with footnote "*** DC Warranty Performance: 1st year 97%, after 2nd year 0.26% annual degradation to year 25." Read on September 25, 2026.
Power temperature coefficient-0.26 %/°C13.6 / 16.0
0.258 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "Temperature Coefficient (Pmax) -0.258%/°C" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), read on September 25, 2026.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CA Rule 21manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
CAN/CSA-C22.2 NO. 107.1-01manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
FCC Part 15 Class Bmanufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
ICES-0003 Class Bmanufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
IEEE1547manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications (printed as "UL1741/IEEE1547") for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
UL 1703manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, UL 1741, CEC" for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
UL 1741manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, UL 1741, CEC" and, in its AC Electrical Specifications, "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" (where it appears as "UL1741/IEEE1547") for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
UL 62109-1manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Printed as "Limited Warranty Module and Microinverter: 25** Yrs Workmanship, Materials and Power Output (Linear)***" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), covering the module and microinverter. Footnote ** reads "** Equipment must be installed by Panasonic Authorized or Premium installer and registered through our website www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five (25) year product and labor". Read on September 25, 2026.
Printed as "*** DC Warranty Performance: 1st year 97%, after 2nd year 0.26% annual degradation to year 25." in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), read on September 25, 2026. It is the warranted yearly decline of DC output from year 2 to year 25; the first-year figure is 97%.
Printed as "Limited Warranty Module and Microinverter: 25** Yrs Workmanship, Materials and Power Output (Linear)***" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), with footnote "*** DC Warranty Performance: 1st year 97%, after 2nd year 0.26% annual degradation to year 25." Read on September 25, 2026.
Internet Archive copy dated June 16, 2024 (the archive's own date); read on October 1, 2026.
Location: PDF page 1 (model list) and PDF page 4 (Table 1-1)
Retrieved Oct 1, 2026
Panasonic's own installation manual for its HIT AC modules (VBHN340SA17E, VBHN330SA17E, VBHN330KA03E, VBHN325KA03E, each with an Enphase IQ7X-96-ACM-US microinverter), originally at https://ftp.panasonic.com/solar/installation/ac_module_install.pdf, which Panasonic's solar support page still links as the AC Module Installation Manual. Revision history ends with the 8th Edition of 2020.8.21 (IMA003-0820-5 printed on the file). North American edition. Table 1-1 prints per-model DC ratings of the PV module (not via the microinverter); the rest is series-level instruction. Panasonic's own host ftp.panasonic.com disallows all robots, so this is an archived copy: the Internet Archive captured Panasonic's own file on 16 June 2024, and that archived copy was read on 1 October 2026. It is labeled as an archived copy, not a current download from Panasonic. Manufacturer instructions, not independent tests.
UL 1703Manufacturer claim · equipment listingClaimedListed when checked
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, UL 1741, CEC" for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
UL 1741Manufacturer claim · equipment listingClaimedListed when checked
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, UL 1741, CEC" and, in its AC Electrical Specifications, "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" (where it appears as "UL1741/IEEE1547") for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
IEEE1547Manufacturer claim · equipment listingClaimedListed when checked
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications (printed as "UL1741/IEEE1547") for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
UL 62109-1Manufacturer claim · equipment listingClaimedListed when checked
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
CA Rule 21Manufacturer claim · equipment listingClaimedListed when checked
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
FCC Part 15 Class BManufacturer claim · equipment listingClaimedListed when checked
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
ICES-0003 Class BManufacturer claim · equipment listingClaimedListed when checked
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
CAN/CSA-C22.2 NO. 107.1-01Manufacturer claim · equipment listingClaimedListed when checked
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Internet Archive copy of Panasonic's own datasheet PDF at https://ftp.panasonic.com/solar/datasheet/black_series_ac_datasheet.pdf, captured on May 13, 2024 and read on September 25, 2026; not a live manufacturer document. Panasonic's document host disallows automated access, so the archived copy is used. The datasheet carries Panasonic's revision code RS20080DS. It documents a module with an integrated microinverter and prints no DC voltage or current figures; its first-page heading reads "N330E".
Archived copies
Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024)
Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].