Key specs

Rated power330 W
Weight19.5 kg / 43 lb converted
Open-circuit voltage71.2 V
Short-circuit current5.99 A
Voltage at max power59.5 V
Current at max power5.55 A

All specifications

Identity

BrandPanasonic · Website
ModelVBHN330KA03E
MarketUS
Manufacturer SKUUnknown
SKU detail
conditions: Panasonic prints the model number VBHN330KA03E in its datasheet model rows and on its product pages, and no separate SKU or part number.
Sources: No source on record
FieldValueConditionsSource
Current at max power5.55 A
Printed as "VBHN330KA03E 96 330 59.5 5.55 71.2 5.99" in the DC Electrical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21): the VBHN330KA03E column lists Cell Number in Series, Rated Power, Vpm, Ipm, Voc and Isc in that order, so its Maximum Power Current (Ipm) is 5.55. The table note reads "*This specification shows the characteristics of the PV module not via the microinverter."
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Maximum Power Current (Ipm) row, VBHN330KA03E column
[1]
Short-circuit current5.99 A
Printed as "VBHN330KA03E 96 330 59.5 5.55 71.2 5.99" in the DC Electrical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21): the VBHN330KA03E column lists Cell Number in Series, Rated Power, Vpm, Ipm, Voc and Isc in that order, so its Short Circuit Current (Isc) is 5.99. The table note reads "*This specification shows the characteristics of the PV module not via the microinverter."
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Short Circuit Current (Isc) row, VBHN330KA03E column
[1]
Voltage at max power59.5 V
Printed as "VBHN330KA03E 96 330 59.5 5.55 71.2 5.99" in the DC Electrical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21): the VBHN330KA03E column lists Cell Number in Series, Rated Power, Vpm, Ipm, Voc and Isc in that order, so its Maximum Power Voltage (Vpm) is 59.5. The table note reads "*This specification shows the characteristics of the PV module not via the microinverter."
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Maximum Power Voltage (Vpm) row, VBHN330KA03E column
[1]
Open-circuit voltage71.2 V
Printed as "VBHN330KA03E 96 330 59.5 5.55 71.2 5.99" in the DC Electrical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21): the VBHN330KA03E column lists Cell Number in Series, Rated Power, Vpm, Ipm, Voc and Isc in that order, so its Open Circuit Voltage (Voc) is 71.2. The table note reads "*This specification shows the characteristics of the PV module not via the microinverter."
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Open Circuit Voltage (Voc) row, VBHN330KA03E column
[1]
Cell typeSilicon hetero-junction
Printed as "Silicon hetero-junction**" in the Cell Type row of the DC Electrical Specifications of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21), with the footnote "Silicon hetero-junction**: Mono crystalline silicon/amorphous silicon hetero-junction."
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Cell Type row
[1]
GroundingEach ledge on the module frame has two larger holes for bolts (0.205’‘diameter (5.2 mm)).; Star washers must be used to make contact through the anodization of the module for this method.; Recommended torque value in tightening bolt and nut is 2.3 N.m (20in-lb).; Use Tyco Electronics 1954381-2 as grounding clip.
Printed as "Each ledge on the module frame has two larger holes for bolts (0.205’‘diameter (5.2 mm))." (PDF page 18), "Star washers must be used to make contact through the anodization of the module for this method." and "Recommended torque value in tightening bolt and nut is 2.3 N.m (20in-lb)." (PDF page 19) and "Use Tyco Electronics 1954381-2 as grounding clip." (PDF page 21) in Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21); statements for all the models it covers.
Where: PDF pages 18, 19 and 21, Earth Ground Wiring and Grounding Methods
[1]
Weight19.5 kg / 43 lb converted
Printed as "Length, mm (inches) 1590 (62.60) Width, mm (inches) 1053 (41.46) Frame Depth, mm (inches) 40 (1.57) Weight, kg (pounds) 19.5 (42.99)" in the Mechanical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21), one set for all four AC models; the weight reads 19.5 kg (42.99 pounds). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1-1, Mechanical Specifications, Weight row
[1] [2]
Clamp torque10 ft-lb
Printed as "Recommendation of bolt torque: 10 ft-lbs." in the Module Installation section of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21) (printed unit spelling "ft-lbs"), for bolt and nut mounting; the IronRidge clamps the module was tested with list "Torque: 9.04 N.m (80 in-lbs)." A statement for all the models it covers.
Where: PDF page 12, Module Installation
[1]
DimensionsW 1,053 × L 1,590 × D 40 mm / W 41.46 × L 62.6 × D 1.6 in converted
Printed as "Length, mm (inches) 1590 (62.60) Width, mm (inches) 1053 (41.46) Frame Depth, mm (inches) 40 (1.57) Weight, kg (pounds) 19.5 (42.99)" in the Mechanical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21), one set printed for "VBHN340SA17E, VBHN330SA17E VBHN330KA03E, VBHN325KA03E". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1-1, Mechanical Specifications
[1] [2]
Rated power330 W
Printed as "VBHN330KA03E 96 330 59.5 5.55 71.2 5.99" in the DC Electrical Specifications of Table 1-1 of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21): the VBHN330KA03E column lists Cell Number in Series, Rated Power, Vpm, Ipm, Voc and Isc in that order, so its Rated Power, Watts (Pmax) is 330. The table note reads "*This specification shows the characteristics of the PV module not via the microinverter." Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1-1, DC Electrical Specifications, Rated Power, Watts (Pmax) row, VBHN330KA03E column
[1] [2]
Mounting methodsThe modules should be mounted at the four (4) quarter points by the means shown in Figure 1.; 1) Positive load with Long frame mounting ・ 33 psf (0-450mm range from edge) ・ 75 psf (230-380mm range from edge); 2) Negative load with Long frame mounting ・ 33 psf (0-450mm range from edge) ・ 61 psf(230-380mm range from edge) ・ 75 psf (230-345mm range from edge); 3) Positive load with Short frame mounting ・ 33 psf (0-250mm range from edge); 4) Negative load with Short frame mounting ・ 33 psf (0-250mm range from edge)
Printed as "The modules should be mounted at the four (4) quarter points by the means shown in Figure 1." and the four UL Certified Load Ratings items quoted in the value, under Mechanical Loading in Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21); Table 1-2 (PDF page 5) prints the Load Resistance per mounting range with "Note) Load Resistance shown above is UL Test-Load. Design load is a value obtained by multiplying the above value by two thirds." Loads vary by mounting range, so no single front or rear load is recorded.
Where: PDF page 3, Mechanical Loading
[1]
Cable bend radiusmake sure the minimum bending radius of the cable is 30 mm or more.
Printed as "make sure the minimum bending radius of the cable is 30 mm or more." in the Wiring section of Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21), about fixing the cable to the stand; a statement for all the models it covers.
Where: PDF page 17, Wiring, General
[1]
Module efficiency19.7 %
Printed as "Module Efficiency 19.7%" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), read on September 25, 2026.
Where: DC Electrical Specifications, Module Efficiency
[2]
Operating temperature-18 to 85 °C / 0 to 185 °F converted
Printed as "The operat- ing temperature of DC module without Microinverter is –18°C (-2°F) to 85°C (185° F)." under Operating Conditions in Panasonic's HIT AC module Installation Manual for VBHNxxxSA17E and VBHNxxxKA03E (8th Edition, 2020.8.21), for the DC module without the microinverter; the same item says "The Operating ambient temperature range must be within –18°C (-2°F) to 60°C (140°F) for VBHN330KA03E." Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 7, Installation, Operating Conditions
[1] [2]
Other compliance claimsCEC; UL Listed as PV Rapid Shut Down Equipment; NEC-2014 and NEC-2017 section 690.12; C22.1-2015 Rule 64-218
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, UL 1741, CEC" and "This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems". The standards on these lines are recorded as certification claims; CEC is a listing and the electrical code references are conformance statements, with no certificate number, scope or issuer. Read on September 25, 2026.
Where: AC Electrical Specifications, Compliance; Safety & Rating Certifications; Features
[2]
Temperature coefficient-0.258 %/°C
Printed as "Temperature Coefficient (Pmax) -0.258%/°C" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), read on September 25, 2026.
Where: DC Electrical Specifications, Temperature Coefficient (Pmax)
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Rated output
330 WEfficiency 19.7 %W / sq ft 18.3* (Calculated: 330 W ÷ (1,590 mm × 1,053 mm = 18.02 sq ft) = 18.3 W/sq ft)
Voltage (STC)
59.5 VVmp · maximum powerVoc · open circuit 71.2 VMax system Not stated
Current (STC)
5.55 AImp · maximum powerIsc · short circuit 5.99 A
Dimensions
D: 40 × W: 1,053 × L: 1,590 mm / D: 1.6 × W: 41.46 × L: 62.6 inWeight 19.5 kg / 43 lb
Warranty
25 yearsPower warranty 25 years

Evidence score

66/10084% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: First-year degradation needed.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency19.7 %20.1 / 26.0

19.7 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Printed as "Module Efficiency 19.7%" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), read on September 25, 2026.

[2]

Product warranty25 years17.5 / 21.0

25 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module

Printed as "Limited Warranty Module and Microinverter: 25** Yrs Workmanship, Materials and Power Output (Linear)***" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), covering the module and microinverter. Footnote ** reads "** Equipment must be installed by Panasonic Authorized or Premium installer and registered through our website www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five (25) year product and labor". Read on September 25, 2026.

[2]

Power warranty25 years13.3 / 16.0

25 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A460-MCE54Db 460W Dual-Glass Module

Printed as "Limited Warranty Module and Microinverter: 25** Yrs Workmanship, Materials and Power Output (Linear)***" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), with footnote "*** DC Warranty Performance: 1st year 97%, after 2nd year 0.26% annual degradation to year 25." Read on September 25, 2026.

[2]

Power temperature coefficient-0.26 %/°C13.6 / 16.0

0.258 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air

Printed as "Temperature Coefficient (Pmax) -0.258%/°C" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), read on September 25, 2026.

[2]

Weight / watt19.5 kg / 330 W1.0 / 5.0

0.05909 against 0.01227 kg per W, the lowest documented for a solar panel (calculated from maker figures): Go Power! 110-Watt Solar Flex™ Module

19.5 kg / 330 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.

[1] [2]

Not documented, 0 points: First-year degradation.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
CA Rule 21manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
CAN/CSA-C22.2 NO. 107.1-01manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
FCC Part 15 Class Bmanufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
ICES-0003 Class Bmanufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
IEEE1547manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications (printed as "UL1741/IEEE1547") for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
UL 1703manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, UL 1741, CEC" for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
UL 1741manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, UL 1741, CEC" and, in its AC Electrical Specifications, "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" (where it appears as "UL1741/IEEE1547") for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
UL 62109-1manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN330KA03E
Limitations
Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]

Warranty

FieldValueConditionsSource
Warranty term25 years
Printed as "Limited Warranty Module and Microinverter: 25** Yrs Workmanship, Materials and Power Output (Linear)***" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), covering the module and microinverter. Footnote ** reads "** Equipment must be installed by Panasonic Authorized or Premium installer and registered through our website www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five (25) year product and labor". Read on September 25, 2026.
Where: Operating Conditions & Safety Ratings, Limited Warranty, and footnote **
[2]
Annual degradation0.26 %
Printed as "*** DC Warranty Performance: 1st year 97%, after 2nd year 0.26% annual degradation to year 25." in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), read on September 25, 2026. It is the warranted yearly decline of DC output from year 2 to year 25; the first-year figure is 97%.
Where: Limited Warranty footnote ***
[2]
Performance warranty25 years
Printed as "Limited Warranty Module and Microinverter: 25** Yrs Workmanship, Materials and Power Output (Linear)***" in Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024), with footnote "*** DC Warranty Performance: 1st year 97%, after 2nd year 0.26% annual degradation to year 25." Read on September 25, 2026.
Where: Operating Conditions & Safety Ratings, Limited Warranty
[2]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Panasonic HIT AC Module Installation Manual, VBHNxxxSA17E and VBHNxxxKA03E with Enphase IQ7X-96-ACM-US (8th Edition, 2020.8.21; Internet Archive copy captured 16 June 2024)Panasonic · Source installation manual · August 2020 · PDF
    Source details
    Revision
    8th Edition
    Revision date
    August 2020

    Internet Archive copy dated June 16, 2024 (the archive's own date); read on October 1, 2026.

    Location: PDF page 1 (model list) and PDF page 4 (Table 1-1)

    Retrieved Oct 1, 2026

    Panasonic's own installation manual for its HIT AC modules (VBHN340SA17E, VBHN330SA17E, VBHN330KA03E, VBHN325KA03E, each with an Enphase IQ7X-96-ACM-US microinverter), originally at https://ftp.panasonic.com/solar/installation/ac_module_install.pdf, which Panasonic's solar support page still links as the AC Module Installation Manual. Revision history ends with the 8th Edition of 2020.8.21 (IMA003-0820-5 printed on the file). North American edition. Table 1-1 prints per-model DC ratings of the PV module (not via the microinverter); the rest is series-level instruction. Panasonic's own host ftp.panasonic.com disallows all robots, so this is an archived copy: the Internet Archive captured Panasonic's own file on 16 June 2024, and that archived copy was read on 1 October 2026. It is labeled as an archived copy, not a current download from Panasonic. Manufacturer instructions, not independent tests.

    Open
  • Datasheets

  • Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024)Official · Panasonic · Official datasheet · May 13, 2024 · PDF
    Certificate & compliance claims (8)
    UL 1703Manufacturer claim · equipment listingClaimedListed when checked

    Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, UL 1741, CEC" for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024)
    UL 1741Manufacturer claim · equipment listingClaimedListed when checked

    Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, UL 1741, CEC" and, in its AC Electrical Specifications, "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" (where it appears as "UL1741/IEEE1547") for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024)
    IEEE1547Manufacturer claim · equipment listingClaimedListed when checked

    Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications (printed as "UL1741/IEEE1547") for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024)
    UL 62109-1Manufacturer claim · equipment listingClaimedListed when checked

    Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024)
    CA Rule 21Manufacturer claim · equipment listingClaimedListed when checked

    Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024)
    FCC Part 15 Class BManufacturer claim · equipment listingClaimedListed when checked

    Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024)
    ICES-0003 Class BManufacturer claim · equipment listingClaimedListed when checked

    Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024)
    CAN/CSA-C22.2 NO. 107.1-01Manufacturer claim · equipment listingClaimedListed when checked

    Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) prints "Compliance CA Rule 21 UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01" in its AC Electrical Specifications for VBHN330KA03E. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024)
    Source details
    Revision
    RS20080DS
    Revision date
    May 13, 2024

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Page 2 Electrical Specifications, Mechanical Specifications and Operating Conditions & Safety Ratings tables

    Retrieved Sep 24, 2026

    Internet Archive copy of Panasonic's own datasheet PDF at https://ftp.panasonic.com/solar/datasheet/black_series_ac_datasheet.pdf, captured on May 13, 2024 and read on September 25, 2026; not a live manufacturer document. Panasonic's document host disallows automated access, so the archived copy is used. The datasheet carries Panasonic's revision code RS20080DS. It documents a module with an integrated microinverter and prints no DC voltage or current figures; its first-page heading reads "N330E".

    Archived copies

    Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRS20080DS · 1.06 MB

    Archived copy, unaltered, kept as a record of what Panasonic published. Original address: https://web.archive.org/web/20240513050020id_/https://ftp.panasonic.com/solar/datasheet/black_series_ac_datasheet.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: e4904db6f40219d0f1c8fc2d6120fe8b8047ef1842bee982f24eaa3576380d0f

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024)

Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRS20080DS · 1.06 MB

Archived copy, unaltered, kept as a record of what Panasonic published. Original address: https://web.archive.org/web/20240513050020id_/https://ftp.panasonic.com/solar/datasheet/black_series_ac_datasheet.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: e4904db6f40219d0f1c8fc2d6120fe8b8047ef1842bee982f24eaa3576380d0f

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
VBHN330KA03E

Manufacturer SKU unknown · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: panels-0.4-personal
documented pct: 84
basis: Unknown
missing:
First-year degradation needed
criteria:
key: efficiency
label: Module efficiency
value: 19.7
unit: Unknown
shown: 19.7 %
shown detail: Unknown
state: documented
points: 20.1
ceiling: 26
weight: 26
share: 77.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: warranty
label: Product warranty
value: 25
unit: Unknown
shown: 25 years
shown detail: Unknown
state: documented
points: 17.5
ceiling: 21
weight: 21
share: 83.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: performanceWarranty
label: Power warranty
value: 25
unit: Unknown
shown: 25 years
shown detail: Unknown
state: documented
points: 13.3
ceiling: 16
weight: 16
share: 83.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: powerTemperature
label: Power temperature coefficient
value: 0.258
unit: Unknown
shown: -0.26 %/°C
shown detail: Unknown
state: documented
points: 13.6
ceiling: 16
weight: 16
share: 85.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: degradation
label: First-year degradation
value: Unknown
unit: Unknown
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 16
weight: 16
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: weightPerWatt
label: Weight / watt
value: 0.0591
unit: Unknown
shown: 19.5 kg / 330 W
shown detail: Unknown
state: documented
points: 1
ceiling: 5
weight: 5
share: 20.8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: 19.5 kg / 330 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.
display note: Unknown
Sources: [1] [2]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Panasonic HIT AC Module Installation Manual, VBHNxxxSA17E and VBHNxxxKA03E with Enphase IQ7X-96-ACM-US (8th Edition, 2020.8.21; Internet Archive copy captured 16 June 2024) (Panasonic · archive · 8th Edition · observed Oct 1, 2026)
  2. Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) (Panasonic · manufacturer · RS20080DS · observed Sep 24, 2026)

Sign in to report an error on this page

Similar products

All with a price