Charged ReviewsSaved 0Compare 0Login

Charged Reviews · Quick reference

Panasonic HIT® Black Series AC Module VBHN330KA03E

Brand
Panasonic
Model
VBHN330KA03E
SKU / part number
?
Category
Solar panels
No photo

chargedreviews.com/panels/panasonic-vbhn330ka03e

Electrical at STC

Rated output (STC)
330 W [1] [2]
Module efficiency
19.7 % [2]
Voltage at max power (Vmp)
59.5 V [1]
Current at max power (Imp)
5.55 A [1]
Open-circuit voltage (Voc)
71.2 V [1]
Short-circuit current (Isc)
5.99 A [1]
Power tolerance
?

Temperature and system limits

Temperature coefficient, Pmax
-0.258 %/°C [2]
Temperature coefficient, Voc
?
Temperature coefficient, Isc
?
Maximum system voltage
?
Maximum series fuse
?
NOCT / NMOT
?
Rated output at NMOT
?
Operating temperature
-18 to 85 °C / 0 to 185 °F converted [1] [2]

Cells and construction

Cell technology
Silicon hetero-junction [1]
Cell count
?
Bifacial
?
Bifaciality
?
Frame
?
Front glass
?
Back cover
?
Panel format
?

Mechanical and connections

Dimensions
W 1,053 × L 1,590 × D 40 mm / W 41.46 × L 62.6 × D 1.6 in converted [1] [2]
Weight
19.5 kg / 43 lb converted [1] [2]
Connectors
?
Cable length
?
Junction box rating
?
Mounting
?
Design load, front
?
Design load, rear
?

Installation (from the manual)

Torque

Clamp or bolt torque
10 ft-lb [1]

Conductors

Cable bending radius / connector notes
make sure the minimum bending radius of the cable is 30 mm or more. [1]

Clearances and orientation

Mounting methods and clamp zones
The modules should be mounted at the four (4) quarter points by the means shown in Figure 1.; 1) Positive load with Long frame mounting ・ 33 psf (0-450mm range from edge) ・ 75 psf (230-380mm range from edge); 2) Negative load with Long frame mounting ・ 33 psf (0-450mm range from edge) ・ 61 psf(230-380mm range from edge) ・ 75 psf (230-345mm range from edge); 3) Positive load with Short frame mounting ・ 33 psf (0-250mm range from edge); 4) Negative load with Short frame mounting ・ 33 psf (0-250mm range from edge) [1]

Grounding

Grounding
Each ledge on the module frame has two larger holes for bolts (0.205’‘diameter (5.2 mm)).; Star washers must be used to make contact through the anodization of the module for this method.; Recommended torque value in tightening bolt and nut is 2.3 N.m (20in-lb).; Use Tyco Electronics 1954381-2 as grounding clip. [1]
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Panasonic HIT® Black Series AC Module VBHN330KA03E · VBHN330KA03E

Warranty

Product warranty25 years[2]
Power warranty term25 years[2]
First-year degradation?
Annual degradation after year one0.26 %[2]
Warranted final output?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?

Certifications and listings

UL 61730?
UL 1703Claimed present at observation [2]
IEC 61215?
IEC 61730?
IEC 62804?
CEC listing?
CA Rule 21Claimed present at observation [2]
CAN/CSA-C22.2 NO. 107.1-01Claimed present at observation [2]
FCC Part 15 Class BClaimed present at observation [2]
ICES-0003 Class BClaimed present at observation [2]
IEEE1547Claimed present at observation [2]
UL 1741Claimed present at observation [2]
UL 62109-1Claimed present at observation [2]

Documents and sources

  1. Panasonic HIT AC Module Installation Manual, VBHNxxxSA17E and VBHNxxxKA03E with Enphase IQ7X-96-ACM-US (8th Edition, 2020.8.21; Internet Archive copy captured 16 June 2024) Installation manual · Revision 8th Edition · Revised 2020-08 · Checked Oct 1, 2026 https://web.archive.org/web/20240616010351id_/https://ftp.panasonic.com/solar/installation/ac_module_install.pdf
  2. Panasonic HIT Black Series AC Module datasheet (VBHN330KA03E) (Internet Archive copy, May 13, 2024) Manufacturer datasheet (Internet Archive copy) · Revision RS20080DS · Revised May 13, 2024 · Checked Sep 24, 2026 https://web.archive.org/web/20240513050020id_/https://ftp.panasonic.com/solar/datasheet/black_series_ac_datasheet.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/panels/panasonic-vbhn330ka03eSome links pay us a commission. That does not affect what we record.