Key specs

Rated power325 W
Weight19 kg / 42 lb converted
Open-circuit voltage69.6 V
Short-circuit current6.03 A
Voltage at max power57.6 V
Current at max power5.65 A

All specifications

Identity

BrandPanasonic · Website
ModelVBHN325SA17
MarketUS
Manufacturer SKUUnknown
SKU detail
conditions: Panasonic prints the model number VBHN325SA17 in its datasheet model rows and on its product pages, and no separate SKU or part number.
Sources: No source on record
FieldValueConditionsSource
Current at max power5.65 A
Printed as "Maximum Power Current (Ipm) 5.70 5.65 5.70 5.65 5.50 5.46" in Table 1 of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), whose header reads "Model VBHN340SA17 VBHN335SA17 VBHN330SA17 VBHN325SA17 VBHN325KA03 VBHN320KA03"; VBHN325SA17 is the fourth column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1. Model Specifications, Maximum Power Current (Ipm) row, VBHN325SA17 column
[1] [2]
Short-circuit current6.03 A
Printed as "Short Circuit Current (Isc) 6.13 6.08 6.07 6.03 5.94 5.89" in Table 1 of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), whose header reads "Model VBHN340SA17 VBHN335SA17 VBHN330SA17 VBHN325SA17 VBHN325KA03 VBHN320KA03"; VBHN325SA17 is the fourth column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1. Model Specifications, Short Circuit Current (Isc) row, VBHN325SA17 column
[1] [2]
Voltage at max power57.6 V
Printed as "Maximum Power Voltage (Vpm) 59.7 59.4 58.0 57.6 59.2 58.7" in Table 1 of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), whose header reads "Model VBHN340SA17 VBHN335SA17 VBHN330SA17 VBHN325SA17 VBHN325KA03 VBHN320KA03"; VBHN325SA17 is the fourth column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1. Model Specifications, Maximum Power Voltage (Vpm) row, VBHN325SA17 column
[1] [2]
Open-circuit voltage69.6 V
Printed as "Open Circuit Voltage (Voc) 71.3 71.0 69.7 69.6 70.9 70.5" in Table 1 of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), whose header reads "Model VBHN340SA17 VBHN335SA17 VBHN330SA17 VBHN325SA17 VBHN325KA03 VBHN320KA03"; VBHN325SA17 is the fourth column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1. Model Specifications, Open Circuit Voltage (Voc) row, VBHN325SA17 column
[1] [2]
Cell typeSilicon hetero-junction
Printed as "Silicon hetero- junction*" in every column of the Cell Type row of Table 1 of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4) (the text breaks the word across a line), with the footnote "Silicon hetero-junction*: Monocrysttaline silicon/amorphous silicon hetero-junction".
Where: PDF page 4, Table 1. Model Specifications, Cell Type row, VBHN325SA17 column
[1]
GroundingEach ledge on the module frame has two larger holes for bolts (0.205’‘diameter (5.2 mm)).; Star washers must be used to make contact through the anodization of the module for this method.; Recommended torque value in tightening bolt and nut is 2.3 N.m (20in-lb).; Use Tyco Electronics 1954381-2 as grounding clip.
Printed as "Each ledge on the module frame has two larger holes for bolts (0.205’‘diameter (5.2 mm))." (PDF page 9), "Star washers must be used to make contact through the anodization of the module for this method." and "Recommended torque value in tightening bolt and nut is 2.3 N.m (20in-lb)." (PDF page 10, bolt and nut method) and "Use Tyco Electronics 1954381-2 as grounding clip." (PDF page 12, grounding clip method) in Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4); statements for all the models it covers. Page 11 adds a lay-in lug method (ILSCO GBL-4DBT or Burndy CL501TN).
Where: PDF pages 9, 10 and 12, Earth Ground Wiring and Grounding Methods
[1]
Weight19 kg / 42 lb converted
Printed as "Mechanical Specifications Length, mm (inches) 1590 (62.60) Width, mm (inches) 1053 (41.46) Frame Depth, mm (inches) 40 (1.57) Weight, kg (pounds) 19 (41.89)" in Table 1 of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), one set of mechanical specifications for all six models; the weight reads 19 kg (41.89 pounds). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1, Mechanical Specifications, Weight row
[1] [2]
Cell count96 cells
Printed as "Cell Number in Series 96 96 96 96 96 96" in Table 1 of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), whose header reads "Model VBHN340SA17 VBHN335SA17 VBHN330SA17 VBHN325SA17 VBHN325KA03 VBHN320KA03"; VBHN325SA17 is the fourth column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1. Model Specifications, Cell Number in Series row, VBHN325SA17 column
[1] [3]
ConnectorsMulti-Contact® Type IV (MC4™)
Printed as "Connector Type2 Multi-Contact® Type IV (MC4™)" in Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024); the footnote says a safety locking clip (PV-SSH4) is not supplied with the module. Read on September 25, 2026.
Where: Page 2 Mechanical Specifications, Connector Type
[2]
Clamp torque10 ft-lb
Printed as "Recommendation of bolt torque: 10 ft-lbs." in the Module Installation section of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4) (printed unit spelling "ft-lbs"), for mounting with a bolt and nut as Figure 5 shows; the same section lists the IronRidge clamps the module was tested with, "Torque: 9.04 N.m (80 in-lbs)." A statement for all the models the manual covers.
Where: PDF page 7, Module Installation
[1]
DimensionsW 1,053 × L 1,590 × D 40 mm / W 41.46 × L 62.6 × D 1.6 in converted
Printed as "Mechanical Specifications Length, mm (inches) 1590 (62.60) Width, mm (inches) 1053 (41.46) Frame Depth, mm (inches) 40 (1.57) Weight, kg (pounds) 19 (41.89)" in Table 1 of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), one set of mechanical specifications for all six models. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1, Mechanical Specifications
[1] [2]
Rated power325 W
Printed as "Rated Power, Watts (Pmax) 340 335 330 325 325 320" in Table 1 of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), whose header reads "Model VBHN340SA17 VBHN335SA17 VBHN330SA17 VBHN325SA17 VBHN325KA03 VBHN320KA03"; VBHN325SA17 is the fourth column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1. Model Specifications, Rated Power, Watts (Pmax) row, VBHN325SA17 column
[1] [2]
Series fuse15 A
Printed in the electrical specifications table of Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024), column 2 of 2 (the model header reads "ELECTRICAL SPECIFICATIONS Model VBHN330SA17 VBHN325SA17"), under the footnoted test condition "STC: Cell temp. 25°C, AM1.5, 1000W/m²"; read on September 25, 2026.
Where: Page 2 Electrical Specifications, Series Fuse Rating
[2]
Mounting methodsThe modules should be mounted at the four (4) quarter points by the means shown in Figure 1.; 1) Positive load with Long frame mounting ・ 33 psf (0-450mm range from edge ・ 75 psf (230-380mm range from edge); 2) Negative load with Long frame mounting ・ 33 psf (0-450mm range from edge ・ 61 psf(230-380mm range from edge) ・ 75 psf (230-345mm range from edge); 3) Positive load with Short frame mounting ・ 33 psf (0-250mm range from edge); 4) Negative load with Short frame mounting ・ 33 psf (0-250mm range from edge)
Printed as "The modules should be mounted at the four (4) quarter points by the means shown in Figure 1." and the four UL Certified Load Ratings items quoted in the value, under Mechanical Loading in Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4); Figure 1 (same page) prints the Load Resistance per mounting range with "Note) Load Resistance shown above is UL Test-Load. Design load is a value obtained by multiplying the above value by two thirds." Loads vary by mounting range, so no single front or rear load is recorded.
Where: PDF page 3, Mechanical Loading
[1]
Cable bend radiusmake sure the curvature of the cable is R50 mm or more.
Printed as "make sure the curvature of the cable is R50 mm or more." in the Wiring section of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), about fixing the cable to the mounting structure rail; a statement for all the models it covers.
Where: PDF page 8, Wiring, General
[1]
Max series fuse15 A
Printed as "Maximum series fuse (A) 15 15 15 15 15 15" in Table 1 of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), whose header reads "Model VBHN340SA17 VBHN335SA17 VBHN330SA17 VBHN325SA17 VBHN325KA03 VBHN320KA03"; VBHN325SA17 is the fourth column.
Where: PDF page 4, Table 1. Model Specifications, Maximum series fuse (A) row, VBHN325SA17 column
[1]
Max system voltage600 V
Printed as "Maximum System Voltage 600 600 600 600 600 600" in Table 1 of Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), whose header reads "Model VBHN340SA17 VBHN335SA17 VBHN330SA17 VBHN325SA17 VBHN325KA03 VBHN320KA03"; VBHN325SA17 is the fourth column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 4, Table 1. Model Specifications, Maximum System Voltage row, VBHN325SA17 column
[1] [2]
Module efficiency19.4 %
Printed in the electrical specifications table of Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024), column 2 of 2 (the model header reads "ELECTRICAL SPECIFICATIONS Model VBHN330SA17 VBHN325SA17"), under the footnoted test condition "STC: Cell temp. 25°C, AM1.5, 1000W/m²"; read on September 25, 2026.
Where: Page 2 Electrical Specifications, Module Efficiency
[2]
Operating temperature-40 to 85 °C / -40 to 185 °F converted
Printed as "The operating temperature must be within –40°C (-40°F ) to 85°C (185°F )." under Operating Conditions in Panasonic's General Installation Manual VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4), a statement for all the models it covers. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 6, Installation, Operating Conditions, item 2
[1] [2]
Other compliance claimsUL 1703, cUL, CEC
Printed as "Safety & Rating Certifications UL 1703, cUL, CEC" in Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024), read on September 25, 2026. UL 1703 is recorded as a certification claim; the other entries are marks, listings or management-system standards printed on the same line, with no certificate number, scope or issuer.
Where: Operating Conditions & Safety Ratings, Safety & Rating Certifications
[2]
Temperature coefficient-0.258 %/°C
Printed in the electrical specifications table of Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024), column 2 of 2 (the model header reads "ELECTRICAL SPECIFICATIONS Model VBHN330SA17 VBHN325SA17"), under the footnoted test condition "STC: Cell temp. 25°C, AM1.5, 1000W/m²"; read on September 25, 2026.
Where: Page 2 Electrical Specifications, Temperature Coefficient (Pmax)
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Rated output
325 WEfficiency 19.4 %W / sq ft 18* (Calculated: 325 W ÷ (1,590 mm × 1,053 mm = 18.02 sq ft) = 18 W/sq ft)
Voltage (STC)
57.6 VVmp · maximum powerVoc · open circuit 69.6 VMax system 600 V
Current (STC)
5.65 AImp · maximum powerIsc · short circuit 6.03 A
Dimensions
D: 40 × W: 1,053 × L: 1,590 mm / D: 1.6 × W: 41.46 × L: 62.6 inWeight 19 kg / 42 lb
Warranty
25 yearsPower warranty 25 years

Evidence score

65/10084% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: First-year degradation needed.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency19.4 %19.8 / 26.0

19.4 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Printed in the electrical specifications table of Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024), column 2 of 2 (the model header reads "ELECTRICAL SPECIFICATIONS Model VBHN330SA17 VBHN325SA17"), under the footnoted test condition "STC: Cell temp. 25°C, AM1.5, 1000W/m²"; read on September 25, 2026.

[2]

Product warranty25 years17.5 / 21.0

25 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module

Printed as "Limited Warranty 25** Yrs Workmanship and Power Output (Linear)***" in Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024). Footnote ** says the installation must be registered at www.panasonicusahitwarranty.com within 60 days to receive the 25-year product workmanship term: "Otherwise, Product Workmanship will be only fifteen (15) years." Read on September 25, 2026.

[2]

Power warranty25 years13.3 / 16.0

25 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A460-MCE54Db 460W Dual-Glass Module

Printed as "Limited Warranty 25** Yrs Workmanship and Power Output (Linear)***" in Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024), with footnote "*** 1st year 97%, after 2nd year 0.26% annual degradation to year 25." Read on September 25, 2026.

[2]

Power temperature coefficient-0.26 %/°C13.6 / 16.0

0.258 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air

Printed in the electrical specifications table of Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024), column 2 of 2 (the model header reads "ELECTRICAL SPECIFICATIONS Model VBHN330SA17 VBHN325SA17"), under the footnoted test condition "STC: Cell temp. 25°C, AM1.5, 1000W/m²"; read on September 25, 2026.

[2]

Weight / watt19 kg / 325 W1.0 / 5.0

0.05846 against 0.01227 kg per W, the lowest documented for a solar panel (calculated from maker figures): Go Power! 110-Watt Solar Flex™ Module

19 kg / 325 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.

[1] [2]

Not documented, 0 points: First-year degradation.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL 1703manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN325SA17
Limitations
Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, cUL, CEC" and "UL 1703 Fire Classification Type 2" in its Operating Conditions & Safety Ratings table for VBHN325SA17. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]

Warranty

FieldValueConditionsSource
Retention90.76 %
Printed as "Power output is guaranteed to 90.76% after 25 years" in Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024), read on September 25, 2026; the percentage is the rated power output warranted at year 25.
Where: Warranty statement
[2]
Warranty term25 years
Printed as "Limited Warranty 25** Yrs Workmanship and Power Output (Linear)***" in Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024). Footnote ** says the installation must be registered at www.panasonicusahitwarranty.com within 60 days to receive the 25-year product workmanship term: "Otherwise, Product Workmanship will be only fifteen (15) years." Read on September 25, 2026.
Where: Operating Conditions & Safety Ratings, Limited Warranty, and footnote **
[2]
Annual degradation0.26 %
Printed as "*** 1st year 97%, after 2nd year 0.26% annual degradation to year 25." in Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024), the warranted yearly decline from year 2 to year 25; the first-year figure is 97% of rated power. Read on September 25, 2026.
Where: Limited Warranty footnote ***
[2]
Performance warranty25 years
Printed as "Limited Warranty 25** Yrs Workmanship and Power Output (Linear)***" in Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024), with footnote "*** 1st year 97%, after 2nd year 0.26% annual degradation to year 25." Read on September 25, 2026.
Where: Operating Conditions & Safety Ratings, Limited Warranty
[2]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Panasonic General Installation Manual Photovoltaic Module HIT VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4; Internet Archive copy captured 15 June 2024)Panasonic · Source installation manual · December 2019 · PDF
    Source details
    Revision
    Ver.2.4 (IMA001-1219-2.4)
    Revision date
    December 2019

    Internet Archive copy dated June 15, 2024 (the archive's own date); read on October 1, 2026.

    Location: PDF page 1 (model list) and PDF page 4 (Table 1)

    Retrieved Oct 1, 2026

    Panasonic's own installation manual for its HIT VBHNxxxSA17 (340, 335, 330, 325) and VBHNxxxKA03 (325, 320) modules, originally at https://ftp.panasonic.com/solar/installation/VBHNxxxSA17_KA03_install.pdf, which Panasonic's solar support page still links. Revision history ends with Ver.2.4 of 2019.12.2; document code IMA001-1219-2.4. North American edition (UL 1703, NEC). Table 1 prints per-model electrical ratings; the rest is series-level instruction. Panasonic's own host ftp.panasonic.com disallows all robots, so this is an archived copy: the Internet Archive captured Panasonic's own file on 15 June 2024, and that archived copy was read on 1 October 2026. It is labeled as an archived copy, not a current download from Panasonic. Manufacturer instructions, not independent tests.

    Open
  • Datasheets

  • Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024)Official · Panasonic · Official datasheet · May 13, 2024 · PDF
    Certificate & compliance claims (1)
    UL 1703Manufacturer claim · equipment listingClaimedListed when checked

    Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024) prints "Safety & Rating Certifications UL 1703, cUL, CEC" and "UL 1703 Fire Classification Type 2" in its Operating Conditions & Safety Ratings table for VBHN325SA17. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024)
    Source details
    Revision
    RS20079DS
    Revision date
    May 13, 2024

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Page 2 Electrical Specifications, Mechanical Specifications and Operating Conditions & Safety Ratings tables

    Retrieved Sep 24, 2026

    Internet Archive copy of Panasonic's own datasheet PDF at https://ftp.panasonic.com/solar/datasheet/n330_n325_datasheet.pdf, captured on May 13, 2024 and read on September 25, 2026; not a live manufacturer document. Panasonic's document host disallows automated access, so the archived copy is used. The datasheet carries Panasonic's revision code RS20079DS.

    Archived copies

    Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRS20079DS · 1.16 MB

    Archived copy, unaltered, kept as a record of what Panasonic published. Original address: https://web.archive.org/web/20240513083922id_/https://ftp.panasonic.com/solar/datasheet/n330_n325_datasheet.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: c566ada8cfd098139dca25d01b5730457bbe8c80db64a17feb92bb30ec72a053

    Open
  • Other documents

  • Panasonic N325 Photovoltaic Module HIT®, 40mm product page (Internet Archive copy, March 2, 2021)Official · Panasonic · Official product page · March 2, 2021 · Web page
    Source details
    Revision
    Not stated
    Revision date
    March 2, 2021

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Product heading, model line and Product details

    Retrieved Sep 24, 2026

    Internet Archive copy of Panasonic's own product page at https://na.panasonic.com/us/energy-solutions/solar/hit-modules/n325-photovoltaic-module-hitr-40mm, captured on March 2, 2021 and read on September 25, 2026; not a live page. Panasonic's product pages for these modules are no longer published.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024)

Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRS20079DS · 1.16 MB

Archived copy, unaltered, kept as a record of what Panasonic published. Original address: https://web.archive.org/web/20240513083922id_/https://ftp.panasonic.com/solar/datasheet/n330_n325_datasheet.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: c566ada8cfd098139dca25d01b5730457bbe8c80db64a17feb92bb30ec72a053

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
VBHN325SA17

Manufacturer SKU unknown · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: panels-0.4-personal
documented pct: 84
basis: Unknown
missing:
First-year degradation needed
criteria:
key: efficiency
label: Module efficiency
value: 19.4
unit: Unknown
shown: 19.4 %
shown detail: Unknown
state: documented
points: 19.8
ceiling: 26
weight: 26
share: 76.1
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: warranty
label: Product warranty
value: 25
unit: Unknown
shown: 25 years
shown detail: Unknown
state: documented
points: 17.5
ceiling: 21
weight: 21
share: 83.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: performanceWarranty
label: Power warranty
value: 25
unit: Unknown
shown: 25 years
shown detail: Unknown
state: documented
points: 13.3
ceiling: 16
weight: 16
share: 83.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: powerTemperature
label: Power temperature coefficient
value: 0.258
unit: Unknown
shown: -0.26 %/°C
shown detail: Unknown
state: documented
points: 13.6
ceiling: 16
weight: 16
share: 85.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: degradation
label: First-year degradation
value: Unknown
unit: Unknown
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 16
weight: 16
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: weightPerWatt
label: Weight / watt
value: 0.0585
unit: Unknown
shown: 19 kg / 325 W
shown detail: Unknown
state: documented
points: 1
ceiling: 5
weight: 5
share: 21
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: 19 kg / 325 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.
display note: Unknown
Sources: [1] [2]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Panasonic General Installation Manual Photovoltaic Module HIT VBHNxxxSA series VBHNxxxKA series (Ver.2.4, IMA001-1219-2.4; Internet Archive copy captured 15 June 2024) (Panasonic · archive · Ver.2.4 · observed Oct 1, 2026)
  2. Panasonic N330/N325 HIT datasheet (VBHN330SA17, VBHN325SA17) (Internet Archive copy, May 13, 2024) (Panasonic · manufacturer · RS20079DS · observed Sep 24, 2026)
  3. Panasonic N325 Photovoltaic Module HIT®, 40mm product page (Internet Archive copy, March 2, 2021) (Panasonic · manufacturer · observed Sep 24, 2026)