Printed as "Maximum Power Current (Imp) 13,37A 13,44A 13,51A 13,58A" in CW Enerji's Installation Manual (V.25.06.01), GROUP 27 CWT108TNFB10- TOPCON FULLBLACK table; the 450 Wp column (column 4 of 4) reads "13,58A". Printed as "All values measured at STC; 1000W/m2, 25°C, 1.5AM" under the tables.
Where: PDF page 32, section 9 Applicable Products, GROUP 27 CWT108TNFB10- TOPCON FULLBLACK table, "Maximum Power Current (Imp)" row, 450 Wp column
Printed as "Short Circuit Current (Isc) 14,17A 14,24A 14,30A 14,38A" in CW Enerji's Installation Manual (V.25.06.01), GROUP 27 CWT108TNFB10- TOPCON FULLBLACK table; the 450 Wp column (column 4 of 4) reads "14,38A". Printed as "All values measured at STC; 1000W/m2, 25°C, 1.5AM" under the tables. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Signature Solar (signaturesolar.com), which stays listed as an additional source.
Where: PDF page 32, section 9 Applicable Products, GROUP 27 CWT108TNFB10- TOPCON FULLBLACK table, "Short Circuit Current (Isc)" row, 450 Wp column
Printed as "Maximum Power Voltage (Vmp) 32,54V 32,74V 32,94V 33,14V" in CW Enerji's Installation Manual (V.25.06.01), GROUP 27 CWT108TNFB10- TOPCON FULLBLACK table; the 450 Wp column (column 4 of 4) reads "33,14V". Printed as "All values measured at STC; 1000W/m2, 25°C, 1.5AM" under the tables.
Where: PDF page 32, section 9 Applicable Products, GROUP 27 CWT108TNFB10- TOPCON FULLBLACK table, "Maximum Power Voltage (Vmp)" row, 450 Wp column
The maker's installation manual and a seller listing print different open circuit voltages. CW Enerji's Installation Manual (V.25.06.01) prints 39.11 V for the CWT108TNFB10 450 Wp class; the Signature Solar listing prints 39.31 V, the figure the same manual prints for the CWT108TN10 450 Wp class.
Printed as "Open Circuit Voltage (Voc) 38,51V 38,71V 38,91V 39,11V" in CW Enerji's Installation Manual (V.25.06.01), GROUP 27 CWT108TNFB10- TOPCON FULLBLACK table; the 450 Wp column (column 4 of 4) reads "39,11V". Printed as "All values measured at STC; 1000W/m2, 25°C, 1.5AM" under the tables. The CWT108TN10 group of the same manual prints 39.31V for its 450 Wp column. Revised on 1 October 2026: The maker's installation manual prints 39.11 V for the 450 Wp column of the CWT108TNFB10 group; the recorded 39.31 V came from a seller listing, so the manual's figure leads and the seller's stays beside it.
Where: PDF page 32, section 9 Applicable Products, GROUP 27 CWT108TNFB10- TOPCON FULLBLACK table, "Open Circuit Voltage (Voc)" row, 450 Wp column
Sources
39.31 V
Distributor specification; use the manufacturer model column for string design.
The frame rails have pre-drilled holes marked with a bonding sign. These holes should be used for bonding purposes and must not be used for mounting the Modules.; There is a bonding hole with 4.2 mm diameter on the edge side closer to the middle of the back frame of the Modules.; The recommended twist torque value is 2.3 N.m.; The recommended torque of locking the nut is 2.0 Nm-2.2 Nm.
Printed as "The frame rails have pre-drilled holes marked with a bonding sign. These holes should be used for bonding purposes and must not be used for mounting the Modules." and, under 7.1 Grounding by Using Grounded Clamp, "There is a bonding hole with 4.2 mm diameter on the edge side closer to the middle of the back frame of the Modules." and "The recommended twist torque value is 2.3 N.m." with "A copper core in size of 12 AWG can be used as bonding clamp."; under 7.2, "The existing Mounting holes which have not been used can be used for bonding." and "The recommended torque of locking the nut is 2.0 Nm-2.2 Nm." in CW Enerji's Installation Manual (V.25.06.01). Third-party bonding devices are allowed "so long as they are certified for bonding Modules".
Where: PDF pages 15 and 16, section 7 Grounding (7.1 grounded clamp, 7.2 unused mounting hole)
Printed as "108 PCS HALF-CUT CELL" in the group 27 (CWT108TNFB10) row of section 9 Applicable Products of CW Enerji's Installation Manual (V.25.06.01).
Where: PDF page 21, section 9 Applicable Products, group 27 row, HÜCRE SAYISI column
Printed as "B) Bolt torque requirement: 12-16 Nm" (spelled "Nm") in section 5.2.2 of CW Enerji's Installation Manual (V.25.06.01), for the M8 clamp bolt ("Bolt: M8."). It applies to every product group the manual lists.
Where: PDF page 10, section 5.2.2 Modules Installed with clamp, item B
W 1,134 × H 1,722 × D 30 mm / W 44.65 × H 67.8 × D 1.2 in converted
Printed as "GROUP 27 CWT108TNFB10 TOPCON FULL BLACK 435W-450W 108 PCS HALF-CUT CELL 1722*1134*30 300-400 mm" in section 9 Applicable Products of CW Enerji's Installation Manual (V.25.06.01); the PANEL BOYUTU (mm) column reads "1722*1134*30" for group 27 (CWT108TNFB10). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to CW Energy (signaturesolar.imagerelay.com), which stays listed as an additional source.
Where: PDF page 21, section 9 Applicable Products, group 27 row, PANEL BOYUTU (mm) column
Printed as "Peak Power (Pmax) 435 Wp 440 Wp 445 Wp 450 Wp" in CW Enerji's Installation Manual (V.25.06.01), GROUP 27 CWT108TNFB10- TOPCON FULLBLACK table; the 450 Wp column (column 4 of 4) reads "450 Wp". Printed as "All values measured at STC; 1000W/m2, 25°C, 1.5AM" under the tables. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to CW Energy (signaturesolar.imagerelay.com), which stays listed as an additional source.
Where: PDF page 32, section 9 Applicable Products, GROUP 27 CWT108TNFB10- TOPCON FULLBLACK table, "Peak Power (Pmax)" row, 450 Wp column
Modules can be installed on the frame using mounting holes, clamps, or an insertion system.; Width: Clamp A no less than 38mm, Clamp B no less than 50mm; Bolt: M8; L2-L1: 300-400 mm; Figure 4 layouts: STATIC LOAD +2400Pa/-2400Pa, +5400Pa/-2400Pa, +3600Pa/-2400Pa, +2400Pa/-2400Pa
Printed as "Modules can be installed on the frame using mounting holes, clamps, or an insertion system." (section 5.2) and as "Width: Clamp A no less than 38mm, Clamp B no less than 50mm," with "Bolt: M8." (section 5.2.2) in CW Enerji's Installation Manual (V.25.06.01). The clamp mounting distance for this group is printed as "GROUP 27 CWT108TNFB10 TOPCON FULL BLACK 435W-450W 108 PCS HALF-CUT CELL 1722*1134*30 300-400 mm" in section 9, whose last column is headed MONTAJ MESAFESİ ARALIĞI (mm) with L2-L1 below it; the manual says "The L1 and L2 values in Figure 4, represent the mounting distance depending on the model type." The four layouts of Figure 4 and their static load labels were read from rendered page 12 (the labels are not in the text layer): clamps on the long sides at L1/L2, rails across the module at L1/L2, rails along the full long sides, and a fourth layout drawn apart from the others. In the text, the manual prints "the maximum static test load on the back of the Modules is 2400 Pa (i.e., wind load), and the maximum static test load on the front of the Modules is 2400 Pa (i.e., wind and snow load)" and "(Design load: 1600 Pa for wind load, 2400 Pa for snow load, safety factor γm = 1.5)"; because the figure prints different loads by layout, no single front or rear load is recorded.
Where: PDF pages 9 to 12, sections 5.2 Installation Method and 5.3 Description of the installation position (Figures 2 to 4), and PDF page 21, section 9 Applicable Products, group 27 row
One new unit at the listed price; shipping and tax are not included. The listing prints a minimum purchase of "10 units". · Store SKU 1400083Price readings (24)
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Power temperature coefficient needed; First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Location: Section 9 (Applicable Products), PDF pages 20 to 22, and the group tables on PDF pages 23 to 44
Retrieved Oct 1, 2026
The maker's own installation manual for its solar panels, captured 1 October 2026 from cw-enerji.com. Revision V.25.06.01 as printed on every page. Its section 9 (Applicable Products) lists 50 product groups by series code (for example CWT108TN10, CWT108TNB10, CWT132TN12R, CWT144TNFB10) with cell type, power range, cell count, panel size and clamp mounting distance, followed by an electrical table per group (Pmax, Vmp, Imp, Voc and Isc for each power class at STC). The rest of the manual (mounting, clamps, grounding, maintenance) applies to every listed group. It does not name a market edition. Manufacturer instructions and nominal ratings, not independent tests.
Archived copies
Archived copy of a document published by CW Enerji. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
CW Enerji Installation Manual (English edition, V.25.06.01)
Archived copy of a document published by CW Enerji. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product / system scope unresolved. Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Product / system scope unresolved. Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.