Read from Aptos Solar's published document at https://www.aptossolar.com/wp-content/uploads/2022/09/DNA-144-MF26-440W_Datasheet.pdf, from the column headed DNA-144-MF26-450W. Printed value: "10.88". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Read from the DNA-144-MF26-450W column (STC, front face: 1000 W/m², 25°C) of the Electrical Specifications table in the Aptos DNA-144-MF26-440W datasheet (2022), by position on the page; the Short Circuit Current (Isc) row prints "11.47" in that column. The text layer runs the table together, for example "41.0 10.74 11.40 41.2 10.81 11.47 41.4 10.88 Standard Test". Captured on September 25, 2026.
Where: Electrical Specifications table, DNA-144-MF26-450W column, Short Circuit Current (Isc) row
Read from Aptos Solar's published document at https://www.aptossolar.com/wp-content/uploads/2022/09/DNA-144-MF26-440W_Datasheet.pdf, from the column headed DNA-144-MF26-450W. Printed value: "41.4". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Read from Aptos Solar's published document at https://www.aptossolar.com/wp-content/uploads/2022/09/DNA-144-MF26-440W_Datasheet.pdf, from the column headed DNA-144-MF26-450W. Printed value: "50.3". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 2, "Open Circuit Voltage VVOC (V)" row
Printed in the Mechanical Properties rows of the Aptos DNA-144-MF26-440W datasheet (2022), whose text layer reads "Mechanical Properties Cell Type Glass Frame Junction Box Dimensions Output Cable Monocrystalline" (the Cell Type value is the first after the row labels), captured on September 25, 2026.
Grounding NEC, article 250 governs grounding method.; Use bolt, M4, cup washer, grounding wires, flat washer, tooth washer, screw nut, M4 and install as shown in the diagram below.; Torque specification is 2 to 3 Nm.
Printed as "Use bolt, M4, cup washer, grounding wires, flat washer, tooth washer, screw nut, M4 and install as shown in the diagram below." and "Torque specification is 2 to 3 Nm." in the Grounding section of Aptos Solar Technology's Aptos Solar Technology Installation Manual, High Efficiency Half-Cell Module (M6, Version: AS-IM-001), after "Grounding NEC, article 250 governs grounding method."
Printed in the Mechanical Properties rows of the Aptos DNA-144-MF26-440W datasheet (2022) as "Weight Cable Length Encapsulant 53.13lbs.(25.1kg)", one value for every model, captured on September 25, 2026. The kilogram figure is recorded as printed.
3.2mm, anti-reflection coating, high transmission, low iron, tempered glass
Printed as "Glass 3.2mm, anti-reflection coating, high transmission, low iron, tempered glass" in Aptos Solar's DNA-144-MF26-440W datasheet (2022), captured on September 28, 2026. The Mechanical Properties table's labels and values run in separate columns in the extracted text; confirmed by rendering page 2 and reading the image. No Backsheet or Rear Glass row is printed for this monofacial model, so rear_surface stays unknown.
Printed as "Bolt torque: 12.5 – 18 NM" for the clamp bolt ("bolt: M8 SS") in Aptos Solar Technology's Aptos Solar Technology Installation Manual, High Efficiency Half-Cell Module (M6, Version: AS-IM-001); the same page prints "Torque value is 12.5 Nm – 18 Nm." for the M8 bolt in the mounting holes.
Where: PDF page 3, Modules Installed with Clamping
W 1,039 × L 2,095 × T 35 mm / W 40.91 × L 82.48 × T 1.4 in converted
Printed in the Mechanical Properties rows of the Aptos DNA-144-MF26-440W datasheet (2022) as "IP68 2095 X 1039 X 35mm", one value for every model, captured on September 25, 2026. Length x width x frame thickness in millimeters as printed.
Printed in the Test Operating Conditions rows of the Aptos DNA-144-MF26-440W datasheet (2022) as "Maximum Series Fuse Maximum System Voltage Maximum Load Capacity (Tested to UL 1703) Fire Performance Class 20A 1,000 VDC (UL&IEC)", one value for every model of the family, captured on September 25, 2026.
Where: Test Operating Conditions, Maximum Series Fuse
Mounting holes are 14mm by 9mm. M8 bolt and fasteners.; Rails can run perpendicular or parallel to panel length.; Clamping distance is quarter of the module length.; Test load is 5400Pa, safety factor is 1.5
Printed as "Mounting holes are 14mm by 9mm. M8 bolt and fasteners.", "Rails can run perpendicular or parallel to panel length." and "Clamping distance is quarter of the module length." (PDF page 3, Mounting Methods and Modules Installed with Clamping) in Aptos Solar Technology's Aptos Solar Technology Installation Manual, High Efficiency Half-Cell Module (M6, Version: AS-IM-001), which also says "Modules should be bolted with M8 and M6 to the support structures through mounting holes located in the frame in the back flanges." Page 4 is headed "High level loading condition"; its clamp range "(1/4L) < S ≤ (1/4L)" is printed "[For modules whose length is less than 1966mm]", which the recorded length of this model exceeds, so it is not listed here. The M6 model tables print "5400 Pa Snow Load / 6200 Pa Wind Load" for the power classes they list.
Where: PDF pages 3-4, Mounting Methods, Modules Installed with Mounting Holes, Modules Installed with Clamping and loading table
Printed as "maximum overcurrent protection rating of 20A" (Regulation Information, a statement for the panels the manual covers) and "Overcurrent protection devices should be employed. 20A current rating for series or parallel." in Aptos Solar Technology's Aptos Solar Technology Installation Manual, High Efficiency Half-Cell Module (M6, Version: AS-IM-001).
Where: PDF page 1, Regulation Information; PDF page 2, Module Wiring
The installation manual prints 1500 V; the data sheet prints 1000 V. Aptos Solar Technology's M6 installation manual (Version: AS-IM-001) prints "AST DNA panels have a maximum system voltage of 1500 VDC." and "1,500 VDC (UL&IEC)" in its DNA 144-MF26 table, while the DNA-144-MF26 data sheet recorded for this model prints 1000 V. Aptos's older Legacy Module Installation Guide also prints 1000 VDC for DNA-144-MF26 modules. Check the module label before designing a string.
Printed as "AST DNA panels have a maximum system voltage of 1500 VDC." in the Specifications paragraph of Aptos Solar Technology's Aptos Solar Technology Installation Manual, High Efficiency Half-Cell Module (M6, Version: AS-IM-001), a statement for all the panels the manual covers (its model tables print "1,500 VDC (UL&IEC)"). Revised on 1 October 2026: Aptos Solar Technology's M6 installation manual, which names this model in its DNA 144-MF26 table heading, prints a maximum system voltage of 1500 V for the DNA panels it covers, and the manual comes first in the source order; the recorded 1000 V from the 2022 data sheet is kept as an alternative.
Where: PDF page 2, Specifications paragraph
Sources
1,000 V
Printed in the Test Operating Conditions rows of the Aptos DNA-144-MF26-440W datasheet (2022) as "Maximum Series Fuse Maximum System Voltage Maximum Load Capacity (Tested to UL 1703) Fire Performance Class 20A 1,000 VDC (UL&IEC)", one value for every model of the family, captured on September 25, 2026. The rating is printed as applying to both UL and IEC.
Read from Aptos Solar's published document at https://www.aptossolar.com/wp-content/uploads/2022/09/DNA-144-MF26-440W_Datasheet.pdf, from the column headed DNA-144-MF26-450W. Printed value: "20.66%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Printed in the Temperature Coefficients rows of the Aptos DNA-144-MF26-440W datasheet (2022) as "Temperature Coefficients Pmmp Temperature Coefficients Isc Temperature Coefficients VOC Normal Operating Cell Temperature (NOCT) -0.38% +0.05%/°C -0.29%/°C" (Pmax), one value for every model of the family, captured on September 25, 2026. The Pmax figure is printed without the "/°C" unit; the row is a temperature coefficient.
Printed in the Temperature Coefficients rows of the Aptos DNA-144-MF26-440W datasheet (2022) as "Temperature Coefficients Pmmp Temperature Coefficients Isc Temperature Coefficients VOC Normal Operating Cell Temperature (NOCT) -0.38% +0.05%/°C -0.29%/°C" (Isc), one value for every model of the family, captured on September 25, 2026. The Pmax figure is printed without the "/°C" unit; the row is a temperature coefficient.
Printed in the Temperature Coefficients rows of the Aptos DNA-144-MF26-440W datasheet (2022) as "Temperature Coefficients Pmmp Temperature Coefficients Isc Temperature Coefficients VOC Normal Operating Cell Temperature (NOCT) -0.38% +0.05%/°C -0.29%/°C" (Voc), one value for every model of the family, captured on September 25, 2026. The Pmax figure is printed without the "/°C" unit; the row is a temperature coefficient.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Product warranty needed; Power warranty needed; First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from Aptos Solar's published document at https://www.aptossolar.com/wp-content/uploads/2022/09/DNA-144-MF26-440W_Datasheet.pdf, from the column headed DNA-144-MF26-450W. Printed value: "20.66%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
0.38 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed in the Temperature Coefficients rows of the Aptos DNA-144-MF26-440W datasheet (2022) as "Temperature Coefficients Pmmp Temperature Coefficients Isc Temperature Coefficients VOC Normal Operating Cell Temperature (NOCT) -0.38% +0.05%/°C -0.29%/°C" (Pmax), one value for every model of the family, captured on September 25, 2026. The Pmax figure is printed without the "/°C" unit; the row is a temperature coefficient.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 61730-1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
DNA-144-MF26-450W
Limitations
The Aptos DNA-144-MF26-440W datasheet (2022) prints "144TM DN UL61730-1, UL61730-2" under Certifications for the family, with no certificate number, issuer or date. Manufacturer claim; no issuer record was read.
UL 61730-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
DNA-144-MF26-450W
Limitations
The Aptos DNA-144-MF26-440W datasheet (2022) prints "144TM DN UL61730-1, UL61730-2" under Certifications for the family, with no certificate number, issuer or date. Manufacturer claim; no issuer record was read.
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
2 on file
Manuals
PDF
M6 Installation GuideOfficial · Aptos Solar Technology · Official instruction manual · PDFSource details
Revision
Not stated
Revision date
Not stated
Document group: manual.
Location: Linked from https://www.aptossolar.com/downloads/ with the link text "M6 Installation Guide"
Retrieved Sep 19, 2026
PDF downloaded from the manufacturer's own downloads library and preserved byte for byte. It establishes the document that link served on the access date. It is attached only to catalog models whose exact model designation appears in the document's text; a datasheet that covers several wattages is recorded as covering exactly those models and nothing else. No issuer verified the certifications it names and no revision history is established.
Archived copies
Archived copy of a document published by Aptos Solar Technology. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Aptos Solar datasheetOfficial · Aptos Solar · Official datasheet · PDFCertificate & compliance claims (2)
UL 61730-1Manufacturer claim · equipment listingClaimedListed when checked
The Aptos DNA-144-MF26-440W datasheet (2022) prints "144TM DN UL61730-1, UL61730-2" under Certifications for the family, with no certificate number, issuer or date. Manufacturer claim; no issuer record was read.
UL 61730-2Manufacturer claim · equipment listingClaimedListed when checked
The Aptos DNA-144-MF26-440W datasheet (2022) prints "144TM DN UL61730-1, UL61730-2" under Certifications for the family, with no certificate number, issuer or date. Manufacturer claim; no issuer record was read.
Archived copy of a document published by Aptos Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Aptos Solar datasheet
Archived copy of a document published by Aptos Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Aptos Solar Technology. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
DNA-144-MF26-450W
Observed Sep 25, 2026
UL 61730-1: claimed
Product / system scope unresolved. The Aptos DNA-144-MF26-440W datasheet (2022) prints "144TM DN UL61730-1, UL61730-2" under Certifications for the family, with no certificate number, issuer or date. Manufacturer claim; no issuer record was read.