Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Victron Energy Quattro 48/10000/140-100/100 120V VE.Bus 50/60Hz, manufacturer product image titled "Quattro 48-10000-140 120V (front)" on the Victron Energy product pageVictron Energy Quattro 48/10000/140-100/100 120V VE.Bus 50/60Hz
Key specs
All specifications
No spec by that name.
Show all 30 specifications
Identity
SKU detail
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 58 kg / 130 lb converted | Published value for this exact SKU: "58 kg". Where: Victron public API technical data: weight | [2] |
| Peak output | 20000 W | Printed as "Peak power 6000 W 10000 W 20000 W" in the Victron Quattro 3kVA - 10kVA 120V datasheet, captured on September 25, 2026; the 48/10000/140-100/100 120V column reads "20000 W" (the table prints one value per power class: 3000, 5000 and 10000 VA). Where: Victron Quattro 3kVA - 10kVA 120V datasheet, specification table, "Peak power" row, 48/10000/140-100/100 120V column | [3] |
| Max charge | 140 A | Published value for this exact SKU: "140 A". Where: Victron public API technical data: maximumBatteryChargeCurrent | [2] |
| Dimensions | W 488 × H 572 × D 344 mm / W 19.2 × H 22.5 × D 13.5 in converted | Published enclosure dimensions for this exact SKU: height 572 mm, width 488 mm, depth 344 mm. Mounting clearances are separate. Where: Victron public API technical data: height, width, depth | [2] |
| Communications | VE.Bus | Published value for this exact SKU: "VE.Bus". Where: Victron public API technical data: communicationPort | [2] |
| Efficiency | 96 % | Published value for this exact SKU: "96 %". Where: Victron public API technical data: maxEfficiency | [2] |
| AC frequency | 60 Hz | Published value for this exact SKU: "60 Hz". Where: Victron public API technical data: aCOutputFrequency | [2] |
| AC configuration | 120 VAC | Printed as "Output when in inverter mode Output voltage: 120 VAC ± 2 %" in the Victron Quattro 3kVA - 10kVA 120V datasheet, captured on September 25, 2026; the 48/10000/140-100/100 120V column reads "120 VAC ± 2 %". Where: Victron Quattro 3kVA - 10kVA 120V datasheet, specification table, "Output voltage" row, 48/10000/140-100/100 120V column | [3] |
| Enclosure rating | IP21 | Published value for this exact SKU: "IP21". Where: Victron public API technical data: protectionCategory | [2] |
| Transfer time | 20 ms | Printed as "This happens so fast (less than 20 milliseconds) that computers and other ele ctronic equipment will continue to operate without disruption." Where: Quattro 3kVA - 10kVA 120V datasheet, Two AC Outputs section | [3] |
| Apparent power | 10,000 VA | Published value for this exact SKU: "10,000 VA". Where: Victron public API technical data: contPowerVA25 | [2] |
| Battery wire size | 2x 50 mm² (cables 0 to 5 m); 2x 95 mm² (5 to 10 m) | Printed as the "Recommended cross-section (mm2) per + and - connection terminal" row, 48/10000/140 column, in the Quattro 5k-10k 120V manual, captured on September 26, 2026. Read from the manual's 48/10000/140-100/100 120V column; the manual does not print this listing's SKU. Where: Battery connection table, 48/10000/140 column | [4] |
| Nominal voltage | 48 V | Published value for this exact SKU: "48 V". Where: Victron public API technical data: batteryVoltageNominal | [2] |
| Surge AC output | 20,000 W | Published value for this exact SKU: "20,000 W". Where: Victron public API technical data: peakPowerRating | [2] |
| AC input wire size | 2 AWG minimum (AC-in-1 and AC-in-2) | Printed as the "Minimum Wire Gauge" row (90˚C copper cable) in the Quattro 5k-10k 120V manual, captured on September 26, 2026. Read from the manual's 48/10000/140-100/100 120V column; the manual does not print this listing's SKU. Where: AC connection table | [4] |
| Idle consumption | 60 W | Published value for this exact SKU: "60 W". Where: Victron public API technical data: zeroLoadPower | [2] |
| Max parallel units | 6 count | Printed as "A maximum of 6 units connected in parallel" (identical devices with the same power ratings) in the Quattro 5k-10k 120V manual, captured on September 26, 2026. Read from the manual's 48/10000/140-100/100 120V column; the manual does not print this listing's SKU. Where: Connecting Quattros in parallel | [4] |
| Terminal torque | 14 N·m | Printed as "Maximum torque: 14 Nm" for the battery connection (AC terminals: maximum torque 7 Nm) in the Quattro 5k-10k 120V manual, captured on September 26, 2026. Read from the manual's 48/10000/140-100/100 120V column; the manual does not print this listing's SKU. Where: Battery connection procedure | [4] |
| AC output wire size | 1/0 AWG minimum (AC-out-1); 6 AWG minimum (AC-out-2) | Printed as the "Minimum Wire Gauge" row (90˚C copper cable) in the Quattro 5k-10k 120V manual, captured on September 26, 2026. Read from the manual's 48/10000/140-100/100 120V column; the manual does not print this listing's SKU. Where: AC connection table | [4] |
| Continuous output | 8 kWConverted: 8,000 W / 1000 = 8 kW | Printed as "Cont. output power at 25 °C / 77 °F 2400 W 4000 W 8000 W" in the Victron Quattro 3kVA - 10kVA 120V datasheet, captured on September 25, 2026; the 48/10000/140-100/100 120V column reads "8000 W" (the table prints one value per power class: 3000, 5000 and 10000 VA). Recorded in kW as a change of unit of that figure. Where: Victron Quattro 3kVA - 10kVA 120V datasheet, specification table, "Cont. output power at 25 °C / 77 °F" row, 48/10000/140-100/100 120V column SourcesConverted: 8,000 W / 1000 = 8 kW | [3] |
| Battery compatibility | Lithium Ion battery compatible | Printed as "Quattro Inverter/Charger 120 V 3 kVA – 10 kVA Lithium Ion battery compatible". Where: Quattro 3kVA - 10kVA 120V datasheet, product title | [3] |
| Standby consumption | 15 W | Printed as "Zero load power in Search mode" for the exact model column; the figure (15 W) applies to Quattro 48/10000/140-100/100 120V VE.Bus 50/60Hz. Where: Quattro 3kVA - 10kVA 120V datasheet, INVERTER table | [3] |
| Continuous AC output | 8,000 W | Published value for this exact SKU: "8,000 W". Where: Victron public API technical data: contPowerW25 | [2] |
| Recommended protection | DC fuse 400 A; AC-in-1 fuse or magnetic circuit breaker rated at 100 A or less; AC-out-2 fuse or circuit breaker rated at max. 50 A | Printed as "Recommended DC fuse" in the battery table and in the AC connection instructions of the Quattro 5k-10k 120V manual, captured on September 26, 2026. Read from the manual's 48/10000/140-100/100 120V column; the manual does not print this listing's SKU. Where: Battery connection table; AC connection | [4] |
| Battery voltage range | [38, 66] VDC V | Published value for this exact SKU: "[38, 66] VDC". Where: Victron public API technical data: dCInputVoltageRange | [2] |
| Operating temperature | [-40, 65] °C °C | Published value for this exact SKU: "[-40, 65] °C". Where: Victron public API technical data: operatingTempRange | [2] |
Owner reviews
No reviews. Be the first to review this product:
Write a review
Sellers
No listed sellers in this data.
Price history
No seller price history.
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
60 against 1 W, the lowest documented for an inverter in the 7 to 15 kW output band (printed by the maker): Fronius Primo 11.4-1 208-240. The bar is a printed bound: less than 1 W, as printed.
Published value for this exact SKU: "60 W".
Research pending, 0 points: Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it worksCertificates
EN-IEC 60335-1manufacturer claimunknown[2]
- Scope
- equipment listing
- Covered models
- QUA483100300
- Limitations
- Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU QUA483100300. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 18, 2026
- Source
- [2]
EN-IEC 60335-2-29manufacturer claimunknown[2]
- Scope
- equipment listing
- Covered models
- QUA483100300
- Limitations
- Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU QUA483100300. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 18, 2026
- Source
- [2]
EN-IEC 62109-1manufacturer claimunknown[2]
- Scope
- equipment listing
- Covered models
- QUA483100300
- Limitations
- Victron's public API records "EN-IEC 62109-1" in its safety field for exact SKU QUA483100300. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 18, 2026
- Source
- [2]
UL 1741manufacturer claimunknown[5] [2]
- Scope
- equipment listing
- Covered models
- QUA483100300
- Limitations
- Victron's public API records "UL 1741" in its safety field for exact SKU QUA483100300, and a manufacturer-hosted certificate document (Certificate Safety RETIE 40117 - All MultiPlus(-II) and Quattro(-II) 120V (Colombia)) lists this SKU. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 18, 2026
- Source
- [5] [2]
Warranty
| Field | Value | Conditions | Source |
|---|---|---|---|
| Remedy | Repair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretion | Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user. Where: Victron Energy Limited Warranty Policy, Warranty section | [6] |
| Conditions | Void after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres | Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user. Where: Victron Energy Limited Warranty Policy, Warranty section | [6] |
| Start basis | Date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date | Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user. Where: Victron Energy Limited Warranty Policy, Warranty section | [6] |
| Warranty term | 5 years Brand-wide Victron policy; names no model | Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase. Where: Victron Energy Limited Warranty Policy, "Warranty" section | [6] |
| Labor and shipping | Not included: the warranty does not perform or reimburse de-installation, transportation and re-installation | Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase. Where: Victron Energy Limited Warranty Policy, Warranty section | [6] |
| Extended warranty | 5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends | Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought. Where: Victron Energy Limited Warranty Policy, Warranty section | [6] |
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- Quattro 5k-10k 120V manual (firmware xxxx400 or higher)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: 4.2 Battery connection; 4.3 AC connection; 4.4.8 Parallel connection
Retrieved Sep 25, 2026
Victron Energy's own manual for the Quattro 12/5000/220-100/100, 24/5000/120-100/100, 48/5000/70-100/100 and 48/10000/140-100/100 120V, hosted on victronenergy.com and captured on September 26, 2026. Tables give values per model column; only the exact model's column is read. A manufacturer document, not an independent test.
Archived copies
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 2.80 MBArchived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Manual-Quattro-5k-10k-120V-%28firmware-xxxx4xx%29-EN-FR-ES.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 95defd211a0bbb2d7550cc02e3bca7cbf3f8118cb6ee0eaf984d5a195cb7bbac
Datasheets
- Quattro 3kVA - 10kVA 120VOpen
Source details
Victron document library entry 1200 (Datasheet).
Location: Datasheet-Quattro-3-10kVA-120V-EN-.pdf
Retrieved Sep 18, 2026
Original manufacturer-hosted PDF preserved byte for byte from the Victron document library, listed by the manufacturer for SKUs QUA125021100, QUA245023110, QUA483021100, QUA485021100, QUA483100100, QUA483100102, QUA482501102. The revision is whatever Victron published at this URL on the access date; no later revision or independent verification is claimed.
SHA-256: d265bddc77ddcf34c6a2c6c00e0735a36e42499cb842ff1407a19f61814addf1
Archived copies
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 1.02 MBArchived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Datasheet-Quattro-3-10kVA-120V-EN-.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: d265bddc77ddcf34c6a2c6c00e0735a36e42499cb842ff1407a19f61814addf1
Warranty
- Victron Energy victron warrantyOpen
Source details
Retrieved Sep 10, 2026
SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e
Archived copies
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 0.11 MBArchived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e
Other documents
- Victron Energy price list 2026-Q3 (EUR C, web edition)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-23.
Location: Rows by article number
Retrieved Sep 22, 2026
Victron Energy's public 2026-Q3 euro price list, archived on September 23, 2026. It is the one manufacturer document that prints each product name beside its article number in visible text, with an "H x W x D" size column in millimetres and a "kg" column, so every ordering code in this manifest is checked against it. It is read for identity and, where noted, for size; no price is recorded from it. Its size figures for the 1000 A and 2000 A SmartShunts differ from the datasheets, which are recorded instead.
Archived copies
Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backup2026-Q3 · 1.84 MBArchived copy, unaltered, kept as a record of what Victron Energy B.V. published. Original address: https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 8bdf35045bbe43e749f98c4c581834066a2882d1a6b0db045f82ff016974aa50
Archive and older revisions
Archive and older revisions0
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Victron Energy reference document
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 8bdf35045bbe43e749f98c4c581834066a2882d1a6b0db045f82ff016974aa50
Certificate Safety RETIE 40117 - All MultiPlus(-II) and Quattro(-II) 120V (Colombia)
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Certificate-Safety-RETIE-40117-All-MultiPlus(-II)-and-Quattro(-II)-120V-(Colombia).pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: cb642d7affe049dd745f8b9e210373941c108684c460471e21ea638d2aee965a
Quattro 3kVA - 10kVA 120V
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Datasheet-Quattro-3-10kVA-120V-EN-.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: d265bddc77ddcf34c6a2c6c00e0735a36e42499cb842ff1407a19f61814addf1
Victron Energy victron warranty
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e
Quattro 5k-10k 120V manual (firmware xxxx400 or higher)
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Manual-Quattro-5k-10k-120V-%28firmware-xxxx4xx%29-EN-FR-ES.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 95defd211a0bbb2d7550cc02e3bca7cbf3f8118cb6ee0eaf984d5a195cb7bbac
Matched on printed specifications
The manufacturer names it
- SunGoldPower PowerMax 314 OutdoorSunGoldPower
Its datasheet:
Pylon, SUNGOLDPOWER, Growatt, Victron, Goodwe, Solis, Luxpower, Sofar, KStar, SMA, MEGAREVO, Afore, Solark, Voltronic, Paceic
- OutBack EnergyCell 5 battery module EC-FE5148 (5 kWh, 51.2 V)OutBack Power
Its datasheet:
CAN: EG4, Growatt, Solark, Deye, Megarevo, Luxpower, Pylon, Victron, Solis, SMA; RS485: EG4, Growatt, Schneider, Voltronic
- Renon Xcellent Plus 16 kWh LiFePO4 battery (R-XC016161-US)Renon Power
Its datasheet:
Inverter dial switch codes for Renon, Schneider Gateway, Sol-Ark, Solis, Studer Xtender, Victron, SMA, Sermatec, Sofar, DEYE, Growatt SPF, Growatt SPH, Must, MEGAREVO, SAJ, Aiswei, Phocos, Voltronic Power, Afore, Lux Power and CHISAGE ESS
- Dyness Powerbox-US LFP battery (10.24 kWh, 51.2 V)Dyness
Its datasheet:
GOODWE, Solis, LUX, Sofar, DEYE (SUNSYNK), VICTRON, IMEON, Sungrow, SMA, RENAC, DELIOS, SAJ (CAN); Axpert/VMIII/MAX, Infinisolar, Growatt SPH (CAN), GMDE; Growatt SPF HVM-P/ES/WPV (RS485); Schneider Conext Series
Show all 12
- ECO-WORTHY Cubix100 48V 100Ah Server Rack Battery (ECO-LFP4810002)ECO-WORTHY
Its datasheet:
Default protocol PYLON; supported mainstream brands: SRNE, VICTRON, DEYE, LUXPOWER, GOODWE
- Renon Xcellent Plus 16 kWh LiFePO4 battery with heating (R-XC016161-H-US)Renon Power
Its datasheet:
Inverter dial switch codes for Renon, Schneider Gateway, Sol-Ark, Solis, Studer Xtender, Victron, SMA, Sermatec, Sofar, DEYE, Growatt SPF, Growatt SPH, Must, MEGAREVO, SAJ, Aiswei, Phocos, Voltronic Power, Afore, Lux Power and CHISAGE ESS
- ECO-WORTHY PowerMega 314ECO-WORTHY
Its datasheet:
CAN protocols: PYLON, Growatt, Victron, Schneider, Luxpowertek, Sorotec, SMA, GoodWe, STUDER, MUST, GINLONG, Senergy, TBB, MEGAREVO; RS485 protocols: PACE, PYLON, Growatt, Voltronic, Luxpowertek, WOW, Schneider
- ECO-WORTHY Cubix 100 48V 100Ah Server Rack Battery (AU, AU-L12L100ACUB100-1)ECO-WORTHY
Its datasheet:
Pre-integrated inverter protocols for Growatt, Deye, Pylon, Sofar, Victron, Goodwe, Luxpower and other energy storage PCS brands
- ECO-WORTHY Cubix 100 48V 100Ah Server Rack Battery (EU, DE-L12L100ACUB100-1)ECO-WORTHY
Its datasheet:
Default protocol PYLON; supported main brands: SRNE, VICTRON, DEYE, LUXPOWER, GOODWE
- ECO-WORTHY Cubix100 48V 100Ah Server Rack Battery (UK, UK-L12L100ACUB100-1)ECO-WORTHY
Its datasheet:
Default protocol PYLON; supported mainstream brands: SRNE, VICTRON, DEYE, LUXPOWER, GOODWE
- RICH SOLAR ALPHA 5 PRORICH SOLAR
Its datasheet:
RS485 and CAN: RICH SOLAR, PYLON, Growatt, Victron Energy, EG4 (Luxpower; RS485 as Luxpower V03), Schneider. RS485 only: PACE MODBUS. CAN only: SMA, GoodWe, SOLIS, MEGAREVO.
- Rubix Stack Series RS51100 battery (51.2 V, 100 Ah, 5.12 kWh)Rubix
Its datasheet:
Sol-Ark, Schneider Electric, Megarevo, MidNite Solar, Deye, EG4, Victron Energy, Outback Power, SRNE Solar, Magnum Energy (listed as compatible inverters; the manual says the list is not comprehensive or exclusive and does not denote closed-loop communication compatibility)
These are the manufacturers’ claims.
Nominal voltage in range
- SunGoldPower PowerMax 314 OutdoorSunGoldPower
Nominal voltage in range 51.2 V; printed range 38 to 66 V
- OutBack EnergyCell 5 battery module EC-FE5148 (5 kWh, 51.2 V)OutBack Power
Nominal voltage in range 51.2 V; printed range 38 to 66 V
- Renon Xcellent Plus 16 kWh LiFePO4 battery (R-XC016161-US)Renon Power
Nominal voltage in range 51.2 V; printed range 38 to 66 V
- Dyness Powerbox-US LFP battery (10.24 kWh, 51.2 V)Dyness
Nominal voltage in range 51.2 V; printed range 38 to 66 V
Show all 12
- ECO-WORTHY Cubix100 48V 100Ah Server Rack Battery (ECO-LFP4810002)ECO-WORTHY
Nominal voltage in range 51.2 V; printed range 38 to 66 V
- Renon Xcellent Plus 16 kWh LiFePO4 battery with heating (R-XC016161-H-US)Renon Power
Nominal voltage in range 51.2 V; printed range 38 to 66 V
- Rubix Stack Series RS51100 battery (51.2 V, 100 Ah, 5.12 kWh)Rubix
Nominal voltage in range 51.2 V; printed range 38 to 66 V
- DAH Solar DHN-LVWES15-G2 Low Voltage BatteryDAH Solar
Nominal voltage in range 51.2 V; printed range 38 to 66 V
- Rubix R-Series RRS51280 battery (51.2 V, 280 Ah, 14.336 kWh)Rubix
Nominal voltage in range 51.2 V; printed range 38 to 66 V
Order: products a manufacturer names first, then by Evidence score at default weights.
Matched on printed specifications only: each manufacturer's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a manufacturer does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- Quattro 48/10000/140-100/100 120V VE.Bus 50/60Hz
Manufacturer SKU QUA483100300
Observed Sep 18, 2026
EN-IEC 60335-1: claimed
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU QUA483100300. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Observed Sep 18, 2026
EN-IEC 60335-2-29: claimed
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU QUA483100300. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Observed Sep 18, 2026
EN-IEC 62109-1: claimed
Product / system scope unresolved. Victron's public API records "EN-IEC 62109-1" in its safety field for exact SKU QUA483100300. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Observed Sep 18, 2026
UL 1741: claimed
Product / system scope unresolved. Victron's public API records "UL 1741" in its safety field for exact SKU QUA483100300, and a manufacturer-hosted certificate document (Certificate Safety RETIE 40117 - All MultiPlus(-II) and Quattro(-II) 120V (Colombia)) lists this SKU. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 85 basis: Unknown missing: Battery conversion efficiency needed criteria: key: certificates label: Certificates value: 22.75 unit: Unknown shown: UL 1741 · EN-IEC 60335-1 +2 shown detail: Claimed state: claimed points: 10.2 ceiling: 45 weight: 45 share: 22.8 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown key: warranty label: Warranty term value: 5 unit: Unknown shown: 5 years shown detail: Unknown state: documented points: 6 ceiling: 30 weight: 30 share: 20 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [6] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: 60 unit: Unknown shown: 60 W shown detail: Unknown state: documented points: 0.2 ceiling: 10 weight: 10 share: 1.7 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [2] | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- Victron Energy price list 2026-Q3 (EUR C, web edition) (Victron Energy B.V. · manufacturer · 2026-Q3 · observed Sep 22, 2026)
- Victron Energy public API record for SKU QUA483100300 (Quattro) (Victron Energy · manufacturer · Victron record modified 2026-09-04 19:09:18 · observed Sep 18, 2026)
- Quattro 3kVA - 10kVA 120V (Victron Energy · manufacturer · observed Sep 18, 2026)
- Quattro 5k-10k 120V manual (firmware xxxx400 or higher) (Victron Energy · manufacturer · observed Sep 25, 2026)
- Certificate Safety RETIE 40117 - All MultiPlus(-II) and Quattro(-II) 120V (Colombia) (Victron Energy · manufacturer · observed Sep 18, 2026)
- Victron Energy victron warranty (Victron Energy · manufacturer · observed Sep 10, 2026)
Sign in to report an error on this page
Similar products
All with a priceOutBack Power Radian GS8048A 8 kVA inverter/charger
Victron Energy MultiPlus-II 48/10000/140-100
Victron Energy Quattro 48/10000/140-100/100 120V
Victron Quattro 48/10000 120V
* Missing details