Printed as "Inverter power systems must always be connected to a grounded wiring system" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 28).
Printed as "5 sec surge power 6750W 5 min surge power 5625W 30 min surge power 4950W" in the MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026.
Printed as "at least 3 inches (7.5 cm) of airspace clearance at the intake and exhaust vents" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 16).
Converted: Published centimetres × 10 = millimetres
Overall envelope uses the labeled installation drawing: 51.4 cm length × 22.9 cm width × 15.1 cm thickness, converted to mm by multiplying by 10. Mounting-hole spacings (21 cm and 41.9 cm) are not overall dimensions. The table rounds thickness to 6 inches; the drawing labels 5 15/16 inches.
Printed as "Inverter efficiency (max) 95%" in the MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026. Manufacturer rating; no test conditions are given.
Printed as "5 sec surge power 6750W 5 min surge power 5625W 30 min surge power 4950W" in the MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026.
Printed as "Inverter efficiency (max) 95%" in the MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026. Manufacturer rating; no test conditions are given.
Printed as "Internal 30-amp AC transfer switch; allowing the incoming AC power to continue powering the loads even if the inverter is off." in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 9).
Printed as "AC output voltage 120 VAC ±2%" in the MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026, with "Output frequency and accuracy 60 Hz ±0.1 Hz".
Printed as "Continuous 4500-watt, true sine-wave output power" in the Features list of the MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026. The specifications table states the same rating as "Continuous power output @ 25°C 4500VA".
Printed as "Output Power (Continuous @ 25°C) 4500W" in the Rev B (6-20-25) brochure, separately from the 5 second (6750W), 5 minute (5625W) and 30 minute (4950W) surge ratings. The owner manual already on the record gives the continuous output in VA (4500 VA).
Printed as "Inverter power systems must always be connected to a grounded wiring system" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 28).
Printed as "at least 3 inches (7.5 cm) of airspace clearance at the intake and exhaust vents" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 16).
Converted: Published centimetres × 10 = millimetres
Overall envelope uses the labeled installation drawing: 51.4 cm length × 22.9 cm width × 15.1 cm thickness, converted to mm by multiplying by 10. Mounting-hole spacings (21 cm and 41.9 cm) are not overall dimensions. The table rounds thickness to 6 inches; the drawing labels 5 15/16 inches.
Printed as "install a 30-amp continuous duty rated breaker at the AC input" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 28).
Printed as "DC Grounding Electrode Wire Size2 #6 AWG (13.3 mm²)" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 21). Note 2: per the NEC, the DC grounding electrode conductor can be a #6 AWG (13.3 mm²) conductor if that is the only connection to the grounding electrode and that grounding electrode is a pipe, rod, or plate electrode.
Printed as "Minimum DC Wire Size3 [90°C rating in conduit] #2 AWG (33.6 mm²) [130 amps]" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 21). The same table prints "Increased size for longer distance 1 to 10 ft (0.3 to 3.0 m) = #2 AWG (33.6 mm²) 10 to 15 ft (3.0 to 4.6 m) = #1 AWG (42.4 mm²)".
Printed as "DC Breaker Size4 125 amps with time delay" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 21). Section 2.3.2 (PDF page 22) says the device must be installed in the positive DC cable line, can be a fuse or a circuit breaker and must be DC rated.
Printed as "this requires a minimum cable size of #8 AWG (8.4 mm²)" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 28). Printed with "The output of the inverter can supply up to 55 amps AC".
Printed as "Battery Temperature Sensor Connection Port – a RJ11 port" and "CAN/Remote Connection Port – a RJ45 port that accepts optional CAN capable accessories" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 11).
Printed as "Optional remote available MNGP2 Mounting Shelf or wall" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 59). Figure 2-2 (PDF page 18) says that when the Little Rosie is mounted with the DC side facing down, the Little Rosie Breaker Box (PN: MNE125LR-120S) must be used.
Location: PDF page 59, Table 6-1 MNLR4548RE Specifications, Operating temperature row
Documented
Neutral / grounding (manual)
In residential installations, neutral conductors are interconnected and should always be connected to safety ground at the main AC panel, not at the inverter
Printed as "neutral conductors are interconnected and should always be connected to safety ground" and "at the main AC panel, not at the inverter" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 56). Section 2.4.1 (PDF page 26) adds that the AC NEUTRAL IN and AC NEUTRAL OUT terminals are electrically tied to each other.
UL 1741Manufacturer claim · equipment listingClaimedListed when checked
Printed as "UL1741" in the "UL listing Listed to UL1741, CSA C22.2 #107.1," row of Table 6-1 in MidNite's own MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026. A manufacturer claim: no certificate number or issuer is printed there and no issuer record was read.
CSA C22.2 #107.1Manufacturer claim · equipment listingClaimedListed when checked
Printed as "CSA C22.2 #107.1" in the "UL listing Listed to UL1741, CSA C22.2 #107.1," row of Table 6-1 in MidNite's own MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026. A manufacturer claim: no certificate number or issuer is printed there and no issuer record was read.
Printed part number and revision are 10-609-1, Rev A. The source URL includes an additional -W; it is retained unchanged. No revision date is inferred from the filename, copyright or PDF metadata. Manufacturer listing claims are not issuer verification.
Location: PDF page 2 (printed page i), Document Information: Part Number and Revision
Retrieved
Manufacturer document claims are not issuer verification. Applicable warranty and certification terms have not been fully reviewed.
Archived copy of a document published by MidNite Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
MidNite Solar MNLR4548RE manufacturer product pageOfficialMidNite SolarOfficial product page
Source details
Revision
Not stated
Revision date
Not stated
Revision date not established.
Location: Original source record
Retrieved
The exact MNLR4548RE page uses a shared Little Rosie family photo whose filename names MNLR3648M. The photograph does not independently verify the exact model label. Specifications in this proposal remain based on the exact-model manual.
Archived copy of the PDF obtained from MidNite Solar's own site on 2026-10-30, copied unchanged.
Location: Page 1, title "MNLR4548RE Inverter/Charger", Product Features and Product Specifications; footer Rev B 6-20-25
Retrieved
MidNite Solar's own one-page MNLR4548RE Inverter/Charger brochure with a Product Specifications table; it prints Rev B and 6-20-25 at the bottom right. It prints "Listings: UL1741 and CSA 22.2 (Pending)": a pending listing is not a certification and none is recorded from it. It prints "Output Power (Continuous @ 25°C) 4500W" separately from the 5 second, 5 minute and 30 minute surge ratings. Its 20.25 x 9 x 6 in and 15 lbs agree with the owner manual already on the record (the manual's drawing gives 5 15/16 in thickness). Obtained from MidNite Solar's own site on 2026-10-30T02:16:32Z (HTTP 200) and copied unchanged into this archive. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by MidNite Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A
Archived copy of a document published by MidNite Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
MidNite Solar MNLR4548RE Inverter/Charger brochure (Rev B, 6-20-25)
Archived copy of a document published by MidNite Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Printed as "At its option, MidNite Solar will repair or replace at no charge" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 64).
Printed as "the MNLR4548RE Inverter/Charger shall be free from defects in materials and workmanship" in the MidNite Solar MNLR4548RE owner manual, 10-609-1 Rev A (PDF page 64).
Printed as "MidNite Solar Inc. warrants to the original customer that the MNLR4548RE Inverter/Charger shall be free from defects in materials and workmanship. This warranty will be valid for a period of five (5) years." in the MNLR4548RE owner manual, captured on September 25, 2026. Proof of purchase is required and a defective unit must reach MidNite within two weeks after the warranty period ends.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "MidNite Solar Inc. warrants to the original customer that the MNLR4548RE Inverter/Charger shall be free from defects in materials and workmanship. This warranty will be valid for a period of five (5) years." in the MNLR4548RE owner manual, captured on September 25, 2026. Proof of purchase is required and a defective unit must reach MidNite within two weeks after the warranty period ends.
Research pending, 0 points: Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
UL 1741Product / system scope unresolvedClaimedListed when checked
Printed as "UL1741" in the "UL listing Listed to UL1741, CSA C22.2 #107.1," row of Table 6-1 in MidNite's own MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026. A manufacturer claim: no certificate number or issuer is printed there and no issuer record was read.
CSA C22.2 #107.1Product / system scope unresolvedClaimedListed when checked
Printed as "CSA C22.2 #107.1" in the "UL listing Listed to UL1741, CSA C22.2 #107.1," row of Table 6-1 in MidNite's own MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026. A manufacturer claim: no certificate number or issuer is printed there and no issuer record was read.
UL 1741Manufacturer claim · equipment listingClaimedListed when checked
Printed as "UL1741" in the "UL listing Listed to UL1741, CSA C22.2 #107.1," row of Table 6-1 in MidNite's own MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026. A manufacturer claim: no certificate number or issuer is printed there and no issuer record was read.
CSA C22.2 #107.1Manufacturer claim · equipment listingClaimedListed when checked
Printed as "CSA C22.2 #107.1" in the "UL listing Listed to UL1741, CSA C22.2 #107.1," row of Table 6-1 in MidNite's own MNLR4548RE owner manual 10-609-1 Rev A, captured on September 25, 2026. A manufacturer claim: no certificate number or issuer is printed there and no issuer record was read.