Key specs

BrandMagnum Energy
ModelMSH3012M-L
Continuous output3 kW
Converted: 3000 W / 1000 = 3 kW
Apparent power3,000 VA
Surge output3,900 W
Battery operating voltage9 to 17 V
AC voltage120 V
Efficiency90 %
Weight24.9 kg / 54.9 lb converted
Product warranty3 years

All specifications

Show all 23 specifications

Identity

BrandMagnum Energy · Website
ModelMSH3012M-L
MarketUnknown
Manufacturer SKUMSH3012M-L
About brandMagnum Series inverters and inverter/chargers, including the MS, MS-PAE and MSH-RV Series, are published by DMX Power, LLC on dmx-power.com, where the catalog pages mark them Made in USA. DMX Power's Limited Warranty Policy names Magnum Series Inverters and Inverter Chargers among its products and says DMX Power makes power inverters for recreational vehicle, marine, fleet, renewable energy and off-grid systems.
SKU detail
locator: Page Models & Specifications tables
conditions: Model number as printed in the DMX Power MSH-M Series page tables; the owner's manual's table names the MSH3012M, not the -L code.
Sources: [1]
FieldValueConditionsSource
Weight24.9 kg / 54.9 lb converted
Unit weight, printed as "55 lb (24.9 kg)" in the Weight row, printed once for every model of the table; the kilogram figure is recorded. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Weight row
[2]
Peak output3900 W for 5 s; 3800 W for 30 s; 3200 W for 5 min; 3000 W for 30 min
The manual's surge rows print 3900 (5 sec), 3800 (30 sec), 3200 (5 min) and 3000 (30 min) for this model. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, 5 sec surge power (real watts) row
[2]
Voltage thd< 5%
Printed as < 5% in the Total Harmonic Distortion (THD) row, printed once for every model of the table. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Total Harmonic Distortion (THD) row
[2]
AC voltage120 V
Printed as "120 VAC ±3% (≤ continuous power)" in the AC output voltage accuracy row, printed once for every model of the table. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, AC output voltage accuracy row
[2]
Idle standby<7 W searching; 30 W inverting with no load (typical)
Printed as "<7 watts" in the Power consumption – searching row, printed once for every model of the table, and as "30 watts" in the MSH3012M column (column 1 of 2) of the Power consumption – inverting (no load) row. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Power consumption – searching row
[2]
Max charge125 A
Continuous charger output, printed as "125 ADC" in the MSH3012M column (column 1 of 2) of the Continuous charger output at 25°C row. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Continuous charger output at 25°C row
[2]
DimensionsW 321 × H 203 × L 349 mm / W 12.6 × H 7.99 × L 13.7 in converted
Printed as "34.9 cm x 32.1 cm x 20.3 cm" in the Unit dimensions (length x width x height) row, printed once for every model of the table, in the axis order the row names (length x width x height); the centimeter figures are recorded in millimeters. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Unit dimensions (length x width x height) row
Sources
Converted: 34.9 cm x 10 = 349 mm; 32.1 cm x 10 = 321 mm; 20.3 cm x 10 = 203 mm
[2]
Efficiency90 %
Peak inverter efficiency, printed as 90.0% in the MSH3012M column (column 1 of 2) of the Inverter efficiency (peak) row. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Inverter efficiency (peak) row
[2]
AC frequency60 Hz
Printed as "60 Hz ± 0.05 Hz" in the Output frequency and accuracy row, printed once for every model of the table. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Output frequency and accuracy row
[2]
Output waveformPure sine wave
Printed as "Output waveform Pure Sine Wave" once for every model of the table. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, waveform row
[2]
Transfer time16 ms
Printed as "<16 msec" in the AC relay transfer time (minimum) row, printed once for every model of the table. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, AC relay transfer time (minimum) row
[2]
Apparent power3,000 VA
Printed as "3000 VA" in the MSH3012M column (column 1 of 2) of the Continuous power output (at 25°C) row. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Continuous power output (at 25°C) row
[2]
Nominal voltage12 V
Printed as 12 VDC in the DMX Power page's Charging table row for the MSH3012M-L.
Where: Page Charging table, DC System column
[1]
Surge AC output3,900 W
Printed as 3900 in the MSH3012M column (column 1 of 2) of the 5 sec surge power (real watts) row, the five second surge power. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, 5 sec surge power (real watts) row
[2]
Continuous output3 kW
Converted: 3000 W / 1000 = 3 kW
Printed as 3000 W continuous on the DMX Power page row for the MSH3012M-L; the owner's manual prints 3000 VA in the MSH3012M column (column 1 of 2) of the Continuous power output (at 25°C) row. 3000 W expressed in kW. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: Page Power & Output table; PDF page 52, MSH-M Series Owner's Manual specifications table, Continuous power output (at 25°C) row
Sources
Converted: 3000 W / 1000 = 3 kW
[1] [2]
Battery compatibilityLithium (LFP)
Printed as battery type "Lithium (LFP)" in the DMX Power page row for the MSH3012M-L.
Where: Page Power & Output table, Battery column
[1]
Battery voltage range9 to 17 V
Printed as "9.0 to 17.0 VDC" in the MSH3012M column (column 1 of 2) of the Input battery voltage range row. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Input battery voltage range row
[2]
Operating temperature-20 to 60 °C / -4 to 140 °F converted
Operating temperature, printed as "-20°C to +60°C (-4°F to 140°F)" in the Operating temperature row, printed once for every model of the table. The DMX Power page links this manual as the manual for the MSH3012M-L; the manual does not print the -L suffix, so the figure is read from the MSH3012M column.
Where: PDF page 52, MSH-M Series Owner's Manual specifications table, Operating temperature row
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
3 kW
Battery voltage
9 to 17 V
Solar input
Not statedMPPT trackers Not stated
AC output
120 V
Warranty
3 years
Size
22.74 L* (Calculated from published dimensions)W: 321 × H: 203 × L: 349 mm / W: 12.6 × H: 7.99 × L: 13.7 inWeight 24.9 kg / 54.9 lb

Evidence score

4/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term3 years3.6 / 30.0

3 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "3 yr Warranty" in the headline figures of the DMX Power family page, for the family.

[1]

Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
Warranty term3 years
Printed as "3 yr Warranty" in the headline figures of the DMX Power family page, for the family.
Where: Page headline figures
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • MSH-M Series Owner's Manual, 64-0058 Rev B, April 2023 (Sensata Technologies)Official · Sensata Technologies · Official instruction manual · April 2023 · PDF
    Source details
    Revision
    64-0058 Rev B
    Revision date
    April 2023

    Archived copy captured on 2026-10-09.

    Location: Appendix A, A-1 Inverter/Charger Specifications (printed page 43)

    Retrieved Oct 9, 2026

    The MagnaSine Hybrid Mobile Series (MSH-M) owner's manual, published in April 2023 by Sensata Technologies, which then made the Magnum products; DMX Power links it from the MSH3012M page. Figures are read from the MSH3012M column (the first of two) of its Appendix A specification table (printed page 43). Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by Sensata Technologies. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup64-0058 Rev B · 4.09 MB

    Archived copy, unaltered, kept as a record of what Sensata Technologies published. Original address: https://dmx-power.com/sites/default/files/product/manual/sensata-msh-m-series-inverter-charger-manual.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2023-04

    Embedded creation date
    Embedded modification date
    Pages
    64

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 6ac52997c09f85d938e2d3d2f782cd2f88ce4d12fc1e54a3afe98e136c848ba3

    Open
  • Other documents

  • DMX Power MSH Series inverter/charger page (November 2, 2026 capture)Official · DMX Power · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    DMX Power catalog page; captured Nov 1, 2026 (archived copy).

    Location: Models & Specifications tables

    Retrieved Nov 1, 2026

    DMX Power's catalog page for the MSH Series (MSH-M) inverter/chargers, fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 06:13:25.615 UTC). DMX Power bought the Magnum Energy line in April 2025. Manufacturer claims, not independent tests.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

MSH-M Series Owner's Manual, 64-0058 Rev B, April 2023 (Sensata Technologies)

Archived copy of a document published by Sensata Technologies. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup64-0058 Rev B · 4.09 MB

Archived copy, unaltered, kept as a record of what Sensata Technologies published. Original address: https://dmx-power.com/sites/default/files/product/manual/sensata-msh-m-series-inverter-charger-manual.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2023-04

Embedded creation date
Embedded modification date
Pages
64

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 6ac52997c09f85d938e2d3d2f782cd2f88ce4d12fc1e54a3afe98e136c848ba3

Submit a document

Matched on printed specifications

The maker names it

  • Rubix Stack Series RS51100 battery (51.2 V, 100 Ah, 5.12 kWh)Rubix

    Its datasheet: Sol-Ark, Schneider Electric, Megarevo, MidNite Solar, Deye, EG4, Victron Energy, Outback Power, SRNE Solar, Magnum Energy (listed as compatible inverters; the manual says the list is not comprehensive or exclusive and does not denote closed-loop communication compatibility)

  • Rubix R-Series RRS25560 battery (25.6 V, 560 Ah, 14.336 kWh)Rubix

    Its datasheet: Sol-Ark, Schneider Electric, Megarevo, MidNite Solar, Deye, EG4, Victron Energy, Outback Power, SRNE Solar, Magnum Energy (listed as compatible inverters; the manual says the list is not comprehensive or exclusive and does not denote closed-loop communication compatibility)

  • Rubix R-Series RRS51280 battery (51.2 V, 280 Ah, 14.336 kWh)Rubix

    Its datasheet: Sol-Ark, Schneider Electric, Megarevo, MidNite Solar, Deye, EG4, Victron Energy, Outback Power, SRNE Solar, Magnum Energy (listed as compatible inverters; the manual says the list is not comprehensive or exclusive and does not denote closed-loop communication compatibility)

  • Rubix Stack Series RS25200 battery (25.6 V, 200 Ah, 5.12 kWh)Rubix

    Its datasheet: Sol-Ark, Schneider Electric, Megarevo, MidNite Solar, Deye, EG4, Victron Energy, Outback Power, SRNE Solar, Magnum Energy (listed as compatible inverters; the manual says the list is not comprehensive or exclusive and does not denote closed-loop communication compatibility)

These are the makers’ claims.

Nominal voltage in range

Show all 12
View all 1,503 batteries in this range

Order: products a maker names first, then by Evidence score at default weights.

Matched on printed specifications only: each maker's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a maker does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
MSH3012M-L

Manufacturer SKU MSH3012M-L

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 30
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 3
unit: Unknown
shown: 3 years
shown detail: Unknown
state: documented
points: 3.6
ceiling: 30
weight: 30
share: 12
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. DMX Power MSH Series inverter/charger page (November 2, 2026 capture) (DMX Power · manufacturer · observed Nov 1, 2026)
  2. MSH-M Series Owner's Manual, 64-0058 Rev B, April 2023 (Sensata Technologies) (Sensata Technologies · manufacturer · 64-0058 Rev B · observed Oct 9, 2026)

Sign in to report an error on this page

Similar products

All with a price

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

* Missing details