Printed as "BLUETOOTH MONITORING Customized EG4 App" in the EG4 LL 12V / 24V user manual v2.0.9 (PDF pages 4, 2.1 EG4 LL 12V 400Ah specifications, general specifications). The row appears only in the 12V 400Ah table.
Where: PDF pages 4, 2.1 EG4 LL 12V 400Ah specifications, general specifications
Printed as "These batteries use lithium iron phosphate cells" in EG4 LL 12V / 24V user manual v2.0.9, Manual, product description. Revised on 1 October 2026: The LL 12V and 24V manual states the batteries use lithium iron phosphate cells; the spec sheet does not state the chemistry.
Grounding screw on the chassis; a grounding wire can run from the rack or cabinet to an equipment grounding conductor terminated at a grounding electrode. Do not ground the rack, cabinet or door to the negative or positive bus bars.
Printed as "8 Ground Screw Grounding point for chassis"; "You can attach a grounding wire from the rack/cabinet to an equipment grounding conductor"; "WARNING: Do not ground rack/cabinet or door to negative or positive bus bars!" in the EG4 LL 12V / 24V user manual v2.0.9 (PDF pages 13, 16, sections 6.2.4 and 6.3.1).
W 482 × H 155 × D 513 mm / W 19 × H 6.1 × D 20.2 in converted
Printed as "DIMENSION (H×W×D) 6.1 in×19 in×20.2 in (15.5 cm×48.2 cm×51.3 cm)" in EG4 LL 12V / 24V user manual v2.0.9, EG4 LL 12V / 24V user manual v2.0.9, section 2.1 EG4 LL 12V 400Ah specifications, DIMENSION row. Revised on 1 October 2026: The LL 12V / 24V user manual prints these dimensions for the 12V 400Ah in centimeters and ranks above the specification sheet; the stored millimeters are the same figures.
Rack mounted: installs in a standard 19-inch cabinet or an EG4 battery rack (rack mount ears)
Printed as "It can be installed in a standard 19-inch cabinet"; "2 Rack mount ear For rack mounting" in the EG4 LL 12V / 24V user manual v2.0.9 (PDF pages 15, 16, Overview of System Components; battery diagram table).
Where: PDF pages 15, 16, Overview of System Components; battery diagram table
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "The EG4 12V & 24V-LL rack-mounted lithium batteries" in the EG4 LL 12V / 24V user manual v2.0.9 (PDF page 10, section 5, brief introduction). The site's classification of the printed wording "rack-mounted" as the rack battery format; a catalog grouping, not a manufacturer term.
Set a DIP switch ID on each battery; the host battery (the one that connects to the inverter) is ID 1, the ID code range is 1 to 16, and all DIP switch settings must be different.
Printed as "The ID code range is 1‒16"; "all DIP switch settings must be different from each other" in the EG4 LL 12V / 24V user manual v2.0.9 (PDF page 17, section 7.1.2, DIP switch ID table).
Where: PDF page 17, section 7.1.2, DIP switch ID table
Printed as "2.1 EG4 LL 12V 400AH SPECIFICATIONS MODULE OPERATING PARAMETERS" in the EG4 LL 12V / 24V user manual v2.0.9 (PDF page 4, section 2.1 heading). Marketed class in the model name; the nominal voltage is printed separately as 12.8 V.
2/0 AWG (min.) up to 10 ft; 4/0 AWG up to 18 ft; 600 V insulation
Printed as "2/0 AWG (min.) 600V 60 in-lbs. (7 Nm) 10 ft. 4/0 AWG 600V 60 in-lbs. (7 Nm) 18 ft." in the EG4 LL 12V/24V User Manual, section 6.2.3, captured on September 26, 2026.
Printed as "12V modules only display 4 cells due to 4 packs being in parallel (4s4p config.)" in the EG4 LL 12V / 24V user manual v2.0.9 (PDF page 18, section 7.2.3, cell information). Applies to the 12V module only.
Where: PDF page 18, section 7.2.3, cell information
Printed as "2/0 AWG (min.) 600V 60 in-lbs. (7 Nm) 10 ft." in the EG4 LL 12V/24V User Manual, section 6.2.3, installation, captured on September 26, 2026.
CAN port (CAN bus communication); RS485 port (RS485 communication); Battery-Comm ports (parallel battery communication)
Printed as "10 CAN port CAN bus port for communication"; "14 RS485 port RS485 communication port"; "16 Battery-Comm ports Parallel battery communication port" in the EG4 LL 12V / 24V user manual v2.0.9 (PDF page 16, section 6.3.1, battery diagram table).
Where: PDF page 16, section 6.3.1, battery diagram table
Never position the battery upside down or face down
Printed as "IMPORTANT: Never position the battery upside down or face down!" in the EG4 LL 12V / 24V user manual v2.0.9 (PDF page 11, section 6.2.2, requirements for installation).
Where: PDF page 11, section 6.2.2, requirements for installation
Printed as "STORAGE RANGE -4°F – 122°F (-20°C – 50°C)" in the EG4 LL 12V/24V User Manual, section 2.1 (LL 12V 400Ah), environmental parameters, captured on September 26, 2026.
Printed as "MODULE VOLTAGE PROTECTION 15.0V 1s 13.8V" in the EG4 LL 12V/24V User Manual, section 2.1 (LL 12V 400Ah), BMS parameters (charge), captured on September 26, 2026. Module over-voltage protection trip, 1 s delay, with its recovery voltage.
Printed as "You must connect the CAN/RS485 port of the host battery" in the EG4 LL 12V / 24V user manual v2.0.9 (PDF page 19, section 7.3.1, protocol selection). The host battery connects to the inverter or communication device. The manual adds that the only supported 12V CAN protocol at this time is for 12V Victron systems.
Where: PDF page 19, section 7.3.1, protocol selection
Printed as "BLUETOOTH MONITORING Customized EG4 App" in the EG4 LL 12V / 24V user manual v2.0.9 (PDF pages 4, 2.1 EG4 LL 12V 400Ah specifications, general specifications). The row appears only in the 12V 400Ah table.
Where: PDF pages 4, 2.1 EG4 LL 12V 400Ah specifications, general specifications
Printed as "MODULE VOLTAGE PROTECTION 9.6V 1s 12.0V" in the EG4 LL 12V/24V User Manual, section 2.1 (LL 12V 400Ah), BMS parameters (discharge), captured on September 26, 2026. Module under-voltage protection trip, with its recovery voltage.
Printed as "CHARGING VOLTAGE (BULK/ABSORB) 14.0V (+/-0.2V) FLOAT 13.5V" in the EG4 LL 12V/24V User Manual, section 2.1 (LL 12V 400Ah), module operating parameters, captured on September 26, 2026.
Not printed for this model in the documents on file. Revised on 1 October 2026: The spec sheet prints more than 7,000 deep charge and discharge cycles but no lifetime energy figure.
Two units totaling 800ah. Initial startup, one unit seems okay. Second unit faults. Won’t start. BMS states under voltage protection. Supplier can’t resolve or replace and provides store credit. I disassemble, check cell voltage. All reasonable. I find partially seated fire protection system wire and correct. Unit turns on without fault. 73% charged. Replace cover and install. Over time, with minimal cycling unit eventuality reads ( and acts) 100% charged. Currently using Victron DVCC to allow for BMS managed charging on both batteries. No load testing as yet.
Will post more as experience grows.
38.33 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 482 × H: 155 × D: 513 mm / W: 19 × H: 6.1 × D: 20.2 in44.5 kg / 98.1 lb0.13 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
17/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
12 V · Server rack · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-22.
Location: Identity block "SKU: EG4LP12V400AV3"; description; Features & Benefits; Documentation list
Retrieved Sep 21, 2026
EG4's own product page for the LL 12V 400Ah rack battery, captured byte for byte on September 22, 2026. It establishes the description (12.8 V, 5.12 kWh, 200 A internal BMS, sixteen UL listed prismatic 3.2 V cells, 7000 cycles to 80 % depth of discharge, 99 % efficiency, LCD screen, selectable closed-loop inverter communications including Victron and EG4, supplied RS485 and parallel cables) and the two product photographs the page carries. The identity block prints the stock keeping unit EG4LP12V400AV3 -- a LifePower4 prefix on a Lifetime Lithium product page -- which disagrees with the model SR-12|400-LL-00 the catalog records from the preserved specification sheet; the disagreement is recorded in the product identity note, not resolved. The page prints no price, no warranty term and no temperature range.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
EG4 LL 12V 400Ah specification sheet v2.0.4
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
SR-12|400-LL-00
Manufacturer SKU SR-12|400-LL-00 · US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 40
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.