locator: Renogy product data (products.json, page 2), listing "REGO 3000W 12V Pure Sine Wave HF Inverter Charger Split-phase Design" (handle rego-3000w-12v-pure-sine-wave-hf-inverter-charger-split-phase-design), option "Default Title", "sku":"RIV1230RCH-SPS-US"
conditions: Renogy's own product data, captured 2026-10-27, prints SKU "RIV1230RCH-SPS-US" for option "Default Title" (variant 43178722394227) of listing "REGO 3000W 12V Pure Sine Wave HF Inverter Charger Split-phase Design".
Printed as "Weight | 22.7 lbs / 10.3 Kg" on page 54 of "Renogy REGO RIV1230RCH-SPS 12V 3000W HF inverter charger user manual" (P2RG-UM-RIV1230RCH, archived PDF sha256 35794417ce0a), row "Weight". Read by scripts/extract-specs-sep21.ts from the archived document attached to this product; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "Surge Power (100 ms) 9000VA" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), PDF pages 53 to 54, Technical Specifications, captured on September 26, 2026.
Where: PDF pages 53 to 54, Technical Specifications
Printed as "Nominal Output Voltage RMS 120V AC (±3%)" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), PDF pages 53 to 54, Technical Specifications, captured on September 26, 2026.
Where: PDF pages 53 to 54, Technical Specifications
Printed as "Output Current 150A @25°C, 5A to 150A adjustable, 5A intervals, default 150A" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), PDF pages 53 to 54, Technical Specifications, captured on September 26, 2026.
Where: PDF pages 53 to 54, Technical Specifications
Printed as "Nominal Efficiency > 91% peak" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), PDF pages 53 to 54, Technical Specifications, captured on September 26, 2026.
Where: PDF pages 53 to 54, Technical Specifications
Printed as "Transfer Time | 10 ms" on page 54 of "Renogy REGO RIV1230RCH-SPS 12V 3000W HF inverter charger user manual" (P2RG-UM-RIV1230RCH, archived PDF sha256 35794417ce0a), row "Transfer Time". Read by scripts/extract-specs-sep21.ts from the archived document attached to this product; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "*Anderson Adapter Cable (4/0 AWG)" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), PDF page 18, Components & Accessories, captured on September 26, 2026.
Printed as "Battery Voltage | 12 V" on page 39 of "Renogy REGO RIV1230RCH-SPS 12V 3000W HF inverter charger user manual" (P2RG-UM-RIV1230RCH, archived PDF sha256 35794417ce0a), row "Battery Voltage". Read by scripts/extract-specs-sep21.ts from the archived document attached to this product; a manufacturer figure as printed, not an independent test. No value was taken from another model.
6 AWG (0 to 10 ft); 4 to 6 AWG (11 to 20 ft); 4 AWG (21 to 30 ft)
Printed as "Recommended Cable Size Cable Length Cable Size 0 ft to 10 ft 6 AWG 11 ft to 20 ft 4 to 6 AWG 21 ft to 30 ft 4 AWG" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), AC wiring, Recommended Cable Size, captured on September 26, 2026.
Printed as "Transfer Relay Rating 50A Maximum Bypass @120V AC" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), PDF pages 53 to 54, Technical Specifications, captured on September 26, 2026.
Where: PDF pages 53 to 54, Technical Specifications
Printed as "No load power Consumption | < 20W (Normal)" on page 54 of "Renogy REGO RIV1230RCH-SPS 12V 3000W HF inverter charger user manual" (P2RG-UM-RIV1230RCH, archived PDF sha256 35794417ce0a), row "No load power Consumption". Printed with the qualifier "<" before the figure. Read by scripts/extract-specs-sep21.ts from the archived document attached to this product; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: instruction manual Renogy REGO RIV1230RCH-SPS 12V 3000W HF inverter charger user manual, page 54, row "No load power Consumption"
Printed as "Noise < 54dB" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), PDF pages 53 to 54, Technical Specifications, captured on September 26, 2026.
Where: PDF pages 53 to 54, Technical Specifications
Printed as "Rated Output Power | 3000W @113°F (45°C)" on page 53 of "Renogy REGO RIV1230RCH-SPS 12V 3000W HF inverter charger user manual" (P2RG-UM-RIV1230RCH, archived PDF sha256 35794417ce0a), row "Rated Output Power". Read by scripts/extract-specs-sep21.ts from the archived document attached to this product; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "Battery Types SLD, AGM, GEL, FLD, LI and USER" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), PDF pages 53 to 54, Technical Specifications, captured on September 26, 2026.
Where: PDF pages 53 to 54, Technical Specifications
Printed as "Storage Temperature -40°F to 158°F / -40°C to 70°C" in the Renogy REGO RIV1230RCH-SPS 12V 3000W HF inverter charger user manual (version A1, April 15, 2025), PDF page 54, captured on September 26, 2026.
Printed as "*NH2 Fuse (400A)" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), PDF pages 18 to 24, battery connection, captured on September 26, 2026.
Printed as "Input Voltage Range 9V to 17V DC (±0.3V) (Full load 11V to 15.8V DC)" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), PDF pages 53 to 54, Technical Specifications, captured on September 26, 2026.
Where: PDF pages 53 to 54, Technical Specifications
Printed as "Operating Temperature Range Full load: -4°F to 113°F / -20°C to 45°C" in the Renogy REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), PDF pages 53 to 54, Technical Specifications, captured on September 26, 2026. Derated ("Down load") from 45°C to 60°C.
Where: PDF pages 53 to 54, Technical Specifications
22.12 L* (Calculated from published dimensions)W: 333 × H: 135 × L: 492 mm / W: 13.1 × H: 5.31 × L: 19.4 inWeight10.3 kg / 22.7 lb
Evidence score
10/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term5 years6.0 / 30.0
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty ⏎ 5 Years" on page 54 of "Renogy REGO RIV1230RCH-SPS 12V 3000W HF inverter charger user manual" (P2RG-UM-RIV1230RCH, archived PDF sha256 35794417ce0a), row "Warranty". Read by scripts/extract-specs-sep21.ts from the archived document attached to this product; a manufacturer figure as printed, not an independent test. No value was taken from another model.
20 against 8 W, the lowest documented for an inverter in the 1.5 to 3.5 kW output band (printed by the maker): Victron Energy Inverter 12/2000 Smart
Printed as "No load power Consumption | < 20W (Normal)" on page 54 of "Renogy REGO RIV1230RCH-SPS 12V 3000W HF inverter charger user manual" (P2RG-UM-RIV1230RCH, archived PDF sha256 35794417ce0a), row "No load power Consumption". Printed with the qualifier "<" before the figure. Read by scripts/extract-specs-sep21.ts from the archived document attached to this product; a manufacturer figure as printed, not an independent test. No value was taken from another model. Printed as a bound: less than 20 W, as printed.
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL-485 and CSA-C22.2 No 107.1manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
RIV1230RCH-SPS
Limitations
Printed by Renogy as "Safety UL-485 and CSA-C22.2 No 107.1" in the Certifications rows of the Technical Specifications (PDF page 54) of the REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), captured on September 26, 2026. Recorded exactly as printed; it was not checked against an issuer directory, and the manual names no certificate number or issuer.
Repair, or replacement with a new or refurbished product, at Renogy's option; refund if it cannot repair or replace
Printed as "Renogy will, at its option, either repair the defective product or replace it with a new or refurbished product of equal or greater performance and reliability." in the Renogy Limited Warranty (RNG-4-243, rev. A7), Page 1, Limited Warranty for All, captured on September 26, 2026.
Original purchaser only; if gifted or resold, the claim goes through the original purchaser
Printed as "This warranty extends only to the original Purchaser. If gifted or resold the customer must go through the original Purchaser in order to claim warranty." in the Renogy Limited Warranty (RNG-4-243, rev. A7), General Conditions for Warranty Claims, captured on September 26, 2026.
Excludes normal wear and tear, improper installation, operation and storage, unauthorized repair or modification, misuse, surges and force majeure; the invoice and a written claim within the term are required
Printed as "The warranty does not cover failures and damages that result from normal wear and tear, improper installation, operation, and storage" in the Renogy Limited Warranty (RNG-4-243, rev. A7), Exclusions and Limitations, captured on September 26, 2026.
Printed as "The warranty is in effect from the date of purchase by the user" in the Renogy Limited Warranty (RNG-4-243, rev. A7), Page 1, Limited Warranty for All, captured on September 26, 2026.
Printed as "Warranty ⏎ 5 Years" on page 54 of "Renogy REGO RIV1230RCH-SPS 12V 3000W HF inverter charger user manual" (P2RG-UM-RIV1230RCH, archived PDF sha256 35794417ce0a), row "Warranty". Read by scripts/extract-specs-sep21.ts from the archived document attached to this product; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Labor not covered; returns for valid warranty service ship at the warrantor's expense and risk
Printed as "This warranty does not cover labor." in the Renogy Limited Warranty (RNG-4-243, rev. A7), General Conditions for Warranty Claims and Exclusions and Limitations, captured on September 26, 2026.
Where: General Conditions for Warranty Claims and Exclusions and Limitations
UL-485 and CSA-C22.2 No 107.1Manufacturer claim · equipment listingClaimedListed when checked
Printed by Renogy as "Safety UL-485 and CSA-C22.2 No 107.1" in the Certifications rows of the Technical Specifications (PDF page 54) of the REGO 12V 3000W HF Inverter Charger RIV1230RCH-SPS user manual (version A1, April 15, 2025), captured on September 26, 2026. Recorded exactly as printed; it was not checked against an issuer directory, and the manual names no certificate number or issuer.
Location: Manual PDF linked from the Renogy product page Downloads list
Retrieved Sep 18, 2026
Renogy user manual published on the matching product page; it documents installation, operation and safety and is attached here as a document rather than as the source of any specification value.
Archived copies
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Renogy company-wide limited warranty schedule covering all product families; it does not state electrical or mechanical specifications for any individual SKU.
Archived copies
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Identity block and Specs tab
Retrieved Sep 24, 2026
Renogy's own product page on renogy.com (its Shopify store), captured on September 25, 2026. The page's identity block prints the stock keeping unit RIV1230RCH-SPS-US and its Specs tab prints the manufacturer's specification table. A manufacturer claim; it does not establish independent test results.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Renogy REGO RIV1230RCH-SPS 12V 3000W HF inverter charger user manual
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].