Printed as "Nominal energy 1280Wh" in RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), RICH SOLAR ALPHA 1 PRO user manual, PDF page 14, Standard Parameters table, Nominal energy row. Revised on 1 October 2026: The ALPHA 1 PRO user manual prints a nominal energy of 1280 Wh, and the manual ranks above the datasheet and product page; 1.28 kWh is the same figure in kilowatt-hours.
Printed as "Standard discharge current 50A" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Data, Battery Technical Parameters (PDF page 14), captured on September 26, 2026.
Printed as "Maximum discharge current 100A" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Data, Battery Technical Parameters (PDF page 14), captured on September 26, 2026.
Printed as "Nominal energy 1280Wh" in RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), RICH SOLAR ALPHA 1 PRO user manual, PDF page 14, Standard Parameters table, Nominal energy row. Revised on 1 October 2026: The ALPHA 1 PRO user manual prints a nominal energy of 1280 Wh, and the manual ranks above the datasheet and product page; 1.28 kWh is the same figure in kilowatt-hours.
Printed as "Standard discharge current 50A" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Data, Battery Technical Parameters (PDF page 14), captured on September 26, 2026.
Printed as "Maximum discharge current 100A" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Data, Battery Technical Parameters (PDF page 14), captured on September 26, 2026.
The ALPHA 1 PRO User Manual (250611) prints "Nominal discharging cutoff voltage 11.2V"; the ALPHA 1 Series datasheet (20260826) prints "Discharging Cutoff Voltage 10.0V" for RS-B121SP.
Printed as "Nominal discharging cutoff voltage 11.2V" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Data, Battery Technical Parameters (PDF page 14), captured on September 26, 2026. Revised on 26 September 2026: The exact-model user manual is the primary source (owner ruling of September 26, 2026); the ALPHA 1 Series datasheet (20260826) prints 10.0V and is kept beside it.
10 V
Printed as "Discharging Cutoff Voltage 10.0V" in the ALPHA 1 Series datasheet (20260826), common to RS-B121, RS-B121S and RS-B121SP, captured on September 26, 2026.
The ALPHA 1 PRO User Manual (250611) prints "≥3200" cycles to 80% capacity retention with full cycles to 11.2V; the ALPHA 1 Series datasheet (20260826) prints "7,000+ (70% DoD)".
Read in RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), PDF page 15, TECHNICAL DATA, Cycle life (times)(77±3.6°F). Revised on 1 October 2026: The manual prints "≥3200" cycles with "capacity retention: ≥80%", matching the record, but the conditions carry editorial history that should not be public.
7,000 cycles
Minimum claim at 70% DoD; C-rate, temperature and capacity-retention endpoint not specified.
Read in RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), PDF page 14, TECHNICAL DATA, Weight. Revised on 1 October 2026: The manual prints "About 24.3lb/11.0kg" as the net battery weight, an approximate figure whose "About" should be kept.
10.89 kg / 24 lb
Date from filename, not separately printed issue date; 4 parallel maximum. Heater activates below 41F and stops above 50F on ALPHA1/PRO only.
9.22 L*Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 168 × H: 211 × L: 260 mmW: 6.61 × H: 8.31 × L: 10.2 in convertedOfficial user manualSources
Printed as "10.2x6.6x8.3in" in RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), RICH SOLAR ALPHA 1 PRO user manual, PDF page 15 (printed page 14), Standard Parameters table, Overall dimensions row. Revised on 1 October 2026: The ALPHA 1 PRO user manual prints the overall dimensions directly in millimeters, 260 x 168 x 211 mm, so the inch conversion is replaced by the printed metric figures.
Printed as "Communication mode Bluetooth" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Data (PDF page 15), read from the rendered page, captured on September 26, 2026.
RICH SOLAR prints "ALPHA 1 PRO | 12V 100Ah LiFePO4 Battery | Premium 12V Lithium Battery for Off-Grid, RVs, Boats" (Store feed, product title (SKU RS-B121SP)). The labels are the maker's own words: Marine from "Boats"; Off-grid from "Off-Grid"; RV and van from "RVs".
Printed as "A maximum of 4 batteries in parallel." in RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), PDF page 10, Configuration warnings. Revised on 1 October 2026: The ALPHA 1 PRO User Manual prints "A maximum of 4 batteries in parallel.", a higher-ranked source than the datasheet, and the limit is a printed maximum.
Location: PDF p2 exact model column and common specifications
Documented
Storage temperature
-30 to 55 °C-22 to 131 °F converted
Less than 1 month; -10 to 45 °C for more than 3 monthsOfficial user manualSources
Printed as "Storage temperature -22~131°F / -30~55℃, 90%RH Max, Less than 1 month" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Data (PDF page 15) read from the rendered page (the text layer uses an unreadable font encoding); for more than 3 months it prints "14~113°F / -10~45℃", captured on September 26, 2026.
Printed as "the heating function automatically turns on, but only when there is charging current present. The battery cannot use its own internal power to activate the heater." in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Description, Heating function (PDF page 7), captured on September 26, 2026.
Charging temperature row printed as bands with a charge current limit for each: 30A at "32~50°F / 0~10℃", 50A at "50~68°F / 10~20℃", 100A at "68~104°F / 20~40℃" and 30A at "104~131°F / 40~55℃" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Data (PDF page 15) read from the rendered page (the text layer uses an unreadable font encoding), captured on September 26, 2026.
Printed as "Discharge temperature -4~140°F /-20~60℃" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Data (PDF page 15) read from the rendered page (the text layer uses an unreadable font encoding), captured on September 26, 2026.
Printed as "Heating Power 100W" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Description, Heating function (PDF page 7) read from the rendered page (the text layer uses an unreadable font encoding), captured on September 26, 2026.
Printed as "Heat the Opening Temperature ≤41°F" with opening condition "Charge" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Description, Heating function (PDF page 7) read from the rendered page (the text layer uses an unreadable font encoding); temperature of the internal probe, not ambient, captured on September 26, 2026.
Printed as "Heating closing Conditions: Disconnect the charger or Temperature ≥50°F" in the RICH SOLAR ALPHA 1 PRO User Manual (file dated 250611), Technical Description, Heating function (PDF page 7) read from the rendered page (the text layer uses an unreadable font encoding), captured on September 26, 2026.
Rich Solar publishes gtin 774534855206 against SKU RS-B121SP in the structured product data on its own product page. Package, bundle and regional variants carry separate codes; no code is carried to another variant.
Not printed for this model in the documents on file. Revised on 1 October 2026: RICH SOLAR prints no lifetime energy figure; the stored value was computed from the nominal energy and the rated cycle count.
6.27 MWh
Our estimate from the ALPHA 1 Series datasheet (20260826), which prints "Nominal Energy 1,280Wh" and "Cycle Life 7,000+ (70% DoD)"; assumes nominal energy on every cycle and models no degradation.
Archived copy of a document published by RICH SOLAR. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Original manufacturer-hosted PDF preserved byte for byte, downloaded from the link published on Rich Solar's own product page for SKU RS-B121SP. The revision is whatever was served at this URL on the access date; no later revision was checked, no issuer or laboratory record was read against anything the document states, and no coverage is claimed beyond the SKU whose page linked it.
Archived copy of a document published by Rich Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
PDF
RICH SOLAR ALPHA 1 PRO specification sheet (file dated 20240428)OfficialRICH SOLAROfficial datasheet
Source details
Revision
Not stated
Revision date
Not stated
Archived copy captured on 2026-10-29.
Location: Page 1, product name
Retrieved
RICH SOLAR's own two-page ALPHA 1 PRO specification sheet (file dated 20240428), served from its store's file host; it prints the product name ALPHA 1 PRO (no RS- code). An earlier or alternate edition beside the documents already on this record; no issue date is printed beyond the file name. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by RICH SOLAR. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Original PDF preserved byte for byte, found linked from the Current Connected listing https://www.currentconnected.com/product/rich-solar-12v-100ah-lifepo4-battery/. The revision is whatever was published at this URL on the access date; exact variant coverage inside the document was not separately verified and no later revision was checked.
Archived copy of a document published by cdn.currentconnected.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Original PDF preserved byte for byte, found linked from the Current Connected listing https://www.currentconnected.com/product/rich-solar-12v-100ah-lifepo4-battery/. The revision is whatever was published at this URL on the access date; exact variant coverage inside the document was not separately verified and no later revision was checked.
Archived copy of a document published by cdn.currentconnected.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
RICH SOLAR Limited WarrantyOfficialRICH SOLAROfficial warranty
Source details
Revision
Not stated
Revision date
Not stated
Location: WARRANTY PERIOD, PRORATED WARRANTY, REMEDY and EXCLUSIONS AND LIMITATIONS
Retrieved
RICH SOLAR's own Limited Warranty page, captured on September 26, 2026. Its WARRANTY PERIOD list gives terms by product category or series, not by stock keeping unit, and marks prorated terms with an asterisk. The manufacturer's published policy, not a certificate.
Manufacturer-operated store product page captured byte for byte and matched to this catalog row on an exact manufacturer SKU match against the published variant SKU RS-B121SP. It establishes what Rich Solar published on that page on the access date: the specification rows printed there, the SKU and barcode in the page's own structured data, the documents linked from it and the photo it shows. Marketing copy, certification wording and stock state on the page remain manufacturer claims that no issuer or laboratory record was read against, and nothing here is carried to another variant.
Archived copy of a document published by RICH SOLAR. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by RICH SOLAR. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Rich Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by cdn.currentconnected.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by cdn.currentconnected.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
RICH SOLAR ALPHA 1 PRO specification sheet (file dated 20240428)
Archived copy of a document published by RICH SOLAR. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
RICH SOLAR will, at its option, (1) repair the product at no charge, using new or refurbished replacement parts, or (2) exchange the product with a product that is new or which has been manufactured from new or serviceable used parts and is at least functionally equivalent to the original product.
Printed on RICH SOLAR's Limited Warranty page, captured on September 26, 2026, which adds that a replacement "assumes the remaining warranty of the original product or ninety (90) days" from replacement or repair, whichever is longer. Revised on 26 September 2026: The earlier value summarized the prorated replacement schedule, now recorded under Proration exactly as printed; the page's REMEDY paragraph is recorded here as printed.
Location: Limited Warranty page, LIMITED TO ORIGINAL CONSUMER BUYER
Documented
Proration
10-Year Prorated Warranty Rates Years 1-3: Full replacement (100% coverage) Year 4: 85% coverage (customer pays 15% of replacement cost) Year 5: 70% coverage (customer pays 30% of replacement cost) Year 6: 55% coverage (customer pays 45% of replacement cost) Year 7: 40% coverage (customer pays 60% of replacement cost) Year 8: 25% coverage (customer pays 75% of replacement cost) Year 9: 10% coverage (customer pays 90% of replacement cost) Year 10: 5% coverage (customer pays 95% of replacement cost)
Printed on RICH SOLAR's Limited Warranty page, captured on September 26, 2026. The page marks the ALPHA PRO Series term with "*" ("*Prorated Warranty") and prints this 10-year table; it does not name the table per row.
This warranty does not apply to (i) damage caused by accident, abuse, misuse, misapplication, or non-RICH SOLAR products; (ii) damage caused by service performed by anyone other than RICH SOLAR; (iii) a product or a part that has been modified without the written permission of RICH SOLAR; (iv) a product where any RICH SOLAR serial number has been removed or defaced, or (v) any product purchased through an online auction house. This limited warranty does not apply to any battery cell or product containing a battery cell unless the battery cell has been fully charged by you within seven (7) days after your purchase of the product and at least once every 6 months thereafter. Please note that failure to properly install or operate the battery will void the Limited Warranty.
Location: Limited Warranty page, EXCLUSIONS AND LIMITATIONS and PRORATED WARRANTY
Documented
Coverage starts
A sales receipt from the original consumer purchase, or other reasonable documentary proof, is required in order to establish the start of the warranty period.
Printed on RICH SOLAR's Limited Warranty page, captured on September 26, 2026; the page adds that completing the online Product Registration Form "within thirty (30) days after purchasing your product, that registration can also establish the start date of the warranty period".
Printed as "*10-Year Warranty" under ALPHA PRO Series on RICH SOLAR's Limited Warranty page, captured on September 26, 2026; the row names the category, not a model. The asterisk is explained as "*Prorated Warranty". Revised on 26 September 2026: Re-read against the current warranty page; the earlier record was an earlier capture of the same page with a shorter note.
Location: Limited Warranty page, WARRANTY PERIOD, ALPHA PRO Series
Documented
Labor and shipping
You must then send the product by mail or courier, with shipping costs paid by you ... We will process your return and send your repaired or replacement product to you at our expense for the product being shipped to locations in North America.
Printed on RICH SOLAR's Limited Warranty page, captured on September 26, 2026. Return shipping at RICH SOLAR's expense is stated only for North America.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
12 V · Case battery · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
CertificatesUL 1973 · UN 38.3 +2Manufacturer certificate29.25 / 45
65 evidence points · 45% weight
UL 1973: strongest qualifying evidence, counted once. Manufacturer-hosted certificate; independent issuer check remains open. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.
Printed as "*10-Year Warranty" under ALPHA PRO Series on RICH SOLAR's Limited Warranty page, captured on September 26, 2026; the row names the category, not a model. The asterisk is explained as "*Prorated Warranty". Revised on 26 September 2026: Re-read against the current warranty page; the earlier record was an earlier capture of the same page with a shorter note.
Not documented, 0 points: Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.