About brandMagnum Series inverters and inverter/chargers, including the MS, MS-PAE and MSH-RV Series, are published by DMX Power, LLC on dmx-power.com, where the catalog pages mark them Made in USA. DMX Power's Limited Warranty Policy names Magnum Series Inverters and Inverter Chargers among its products and says DMX Power makes power inverters for recreational vehicle, marine, fleet, renewable energy and off-grid systems.
conditions: Model number as printed in the DMX Power ME Series page tables and in the installation section of the ME Series Owner's Manual (64-0002 Rev D, April 2017), whose specifications table heads the column ME2012 (-15B, -20B).
Unit weight, printed as "37 lb (16.8 kg)" in the ME2012 column (column 1 of 3) of the Unit Weight row; the kilogram figure is recorded. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, Unit Weight row
3700 W for 5 s; 3450 W for 30 s; 3100 W for 5 min; 2400 W for 30 min
The manual's surge rows print 3700 (5 sec), 3450 (30 sec), 3100 (5 min) and 2400 (30 min) for this model (the ME2012 column). The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, 5 sec Surge Power (real watts) row
Printed as "120 VAC ±5% (≤ continuous power)" in the AC Output Voltage Accuracy row, printed once for every model of the table. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, AC Output Voltage Accuracy row
5 W search mode (typical); 20 W inverting with no load (typical)
Printed as "5 watts" in the Search Mode (typical) row, printed once for every model of the table, and as "20 watts" in the ME2012 column (column 1 of 3) of the No Load (120 VAC output, typical) row. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, Search Mode (typical) row
Continuous charger output, printed as "100 ADC" in the ME2012 column (column 1 of 3) of the Continuous Output at 45°C row. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, Continuous Output at 45°C row
W 321 × H 349 × D 203 mm / W 12.6 × H 13.7 × D 7.99 in converted
Printed as "34.9 cm x 32.1 cm x 20.3 cm" in the Unit Dimensions (h x w x d) row, printed once for every model of the table, in the axis order the row names (height x width x depth); the centimeter figures are recorded in millimeters. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, Unit Dimensions (h x w x d) row
Sources
Converted: 34.9 cm x 10 = 349 mm; 32.1 cm x 10 = 321 mm; 20.3 cm x 10 = 203 mm
Peak inverter efficiency, printed as 95% in the ME2012 column (column 1 of 3) of the Inverter Efficiency (peak) row. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, Inverter Efficiency (peak) row
Printed as "60 Hz ± 0.1 Hz" in the Output Frequency and Accuracy row, printed once for every model of the table. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, Output Frequency and Accuracy row
Printed as "Waveform Modified Sine Wave" once for every model of the table. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, waveform row
60 A breaker (single pole), maximum at the inverter AC input
The ME Series Owner's Manual (64-0002 Rev D, April 2017) says "ME2012-15B: 45-amp breaker (single pole); ME2012-20B: 60-amp breaker (single pole)." for the maximum breaker size required at the inverter AC input; these breaker sizes allow full charging and full pass-thru.
Where: PDF page 32, Figure 2-11, AC Wiring for Single In – Dual Out Configurations
Printed as "16 msecs" in the Transfer Time row, printed once for every model of the table. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, Transfer Time row
Printed as "2000 VA" in the ME2012 column (column 1 of 3) of the Continuous Power Output (@ 45°C) row. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, Continuous Power Output (@ 45°C) row
Printed as 3700 in the ME2012 column (column 1 of 3) of the 5 sec Surge Power (real watts) row, the five second surge power. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, 5 sec Surge Power (real watts) row
The Safety Listings row as printed under the column headed ME2012 (-15B, -20B), which names this code. Manufacturer claims; no issuer directory was checked. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, Safety Listings row
Printed as 2000 W continuous on the DMX Power page row for the ME2012-20B; the owner's manual prints 2000 VA in the ME2012 column (column 1 of 3) of the Continuous Power Output (@ 45°C) row. 2000 W expressed in kW. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: Page Power & Output table; PDF page 51, ME Series Owner's Manual specifications table, Continuous Power Output (@ 45°C) row
Printed as "9 to 16 VDC" in the ME2012 column (column 1 of 3) of the Input Battery Voltage Range row. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, Input Battery Voltage Range row
Operating temperature, printed as "-20°C to +60°C (-4°F to 140°F)" in the Operating Temperature row, printed once for every model of the table. The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, ME Series Owner's Manual specifications table, Operating Temperature row
22.74 L* (Calculated from published dimensions)W: 321 × H: 349 × D: 203 mm / W: 12.6 × H: 13.7 × D: 7.99 inWeight16.8 kg / 37 lb
Evidence score
4/100Missing details30% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term3 years3.6 / 30.0
3 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 3 years parts and labor" once for every model of the table in the ME Series Owner's Manual (64-0002 Rev D, April 2017). The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
3 years
Printed as "Warranty 3 years parts and labor" once for every model of the table in the ME Series Owner's Manual (64-0002 Rev D, April 2017). The manual heads this column ME2012 (-15B, -20B) and prints the ME2012-20B itself in its installation section.
Where: PDF page 51, specifications table, Warranty row
Linked from DMX Power's ME Series family page and its Models & Specifications table; captured Nov 1, 2026 (archived copy).
Location: PDF page 22, Table 2-1; PDF page 51, Appendix A, A-1 Inverter/Charger Specifications
Retrieved Nov 1, 2026
The ME Series Owner's Manual (64-0002 Rev D, April 2017), the owner's and installation manual of the ME2012, ME2512 and ME3112, linked from DMX Power's ME Series family page and its Models & Specifications table and fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 06:33:19.555 UTC). DMX Power bought the Magnum Energy line in April 2025. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
DMX Power catalog page; captured Nov 1, 2026 (archived copy).
Location: Models & Specifications tables
Retrieved Nov 1, 2026
DMX Power's catalog page for the ME Series inverter/chargers, fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 06:11:25.599 UTC). DMX Power bought the Magnum Energy line in April 2025. Manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
ME Series Owner's Manual (64-0002 Rev D, April 2017) (November 2, 2026 capture)
Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
* Missing details
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.