Charged ReviewsSaved 0Compare 0Login
GoodWe GW8600A-BP
GoodWe
Inverter charger

GoodWe GW8600A-BP

Key specs

Weight32 kg / 71 lb converted
Nominal voltage360 V
Efficiency96.6 %
Max charge50 A
AC frequency60 Hz
Apparent power8,600 VA

3 specs not documented yet: maximum grid charging, continuous output, standby consumptionHelp fill in ›

All specifications

Identity

BrandGoodWe · Website
ModelGW8600A-BP
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
Weight32 kg / 71 lb converted
Printed as "Weight 62.8lb (28.5kg) 62.8lb (28.5kg) 70.5lb (32kg) 70.5lb (32kg) 70.5lb (32kg) 70.5lb (32kg)" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), General data table, GW8600A-BP column, captured on September 25, 2026.
Where: GoodWe A-BP Series datasheet, Technical Data, General data table, GW8600A-BP column
[1]
Peak output10,320 VA for 60 s (backup output)
Printed as "Max. Output Apparent Power (VA)*2 5000 (6000@60sec) 6000 (7200@60sec) 7000 (8400@60sec) 7600 (9120@60sec) 8600 (10320@60sec) 9600 (11520@60sec)" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), AC output (back-up) table, GW8600A-BP column, captured on September 25, 2026. The datasheet footnote says this can be reached only if battery power is enough; the figure is backup apparent power in VA, not W.
Where: GoodWe A-BP Series datasheet, Technical Data, AC output (back-up) table, GW8600A-BP column
[1]
AC voltage240 V
Printed as "Nominal Output Voltage (V) 240" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), AC output table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe A-BP Series datasheet, Technical Data, AC output table, merged cell
[1]
Max charge50 A
Printed as "Max. Continuous Charging Current (A) 50" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe A-BP Series datasheet, Technical Data, Battery input table, merged cell
[1]
DimensionsW 415 × H 790 × D 175 mm / W 16.3 × H 31.1 × D 6.89 in converted
Printed as "Dimension (W × H × D) 16.3 × 31.1 × 6.9 in (415 × 790 × 175 mm)" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe A-BP Series datasheet, Technical Data, General data table, merged cell
[1]
CommunicationsBMS: RS485/CAN; Meter: RS485; EMS: RS485 (insulated); Portal: WiFi, LAN (optional)
Printed as "Communication with BMS RS485; CAN Communication with Meter RS485 Communication with EMS RS485 (Insulated) Communication with Portal Wi-Fi; LAN (Optional)" in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026. Same for every model in the series.
Where: A-BP User Manual, 3.4.1, General Data, Communication rows
[2]
Efficiency96.6 %
Printed as "Battery Charge/Discharge to AC Max Efficiency 96.6%" in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026. The A-BP is an AC-coupled retrofit inverter with no PV input; this battery-charge/discharge-to-AC figure is the only efficiency the manual publishes.
Where: A-BP User Manual, 3.4.1, Efficiency table
[2]
AC frequency60 Hz
Printed as "Nominal AC Grid Frequency (Hz) 60" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), AC output table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe A-BP Series datasheet, Technical Data, AC output table, merged cell
[1]
Max discharge50 A
Printed as "Max. Continuous Discharging Current (A) 50" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe A-BP Series datasheet, Technical Data, Battery input table, merged cell
[1]
AC configuration240 V (L1-L2)
Printed as "Output Voltage Range (V) 211 to 264 @240"; "Nominal Output Voltage L1-L2/L- N(Vac) 240/120"; "The back-up function needs the addition of a GoodWe auto-transformer for 120V back-up loads." in GoodWe A-BP Series User Manual (EN, V1.4-2023-01-30) (PDF page 41; PDF page 21). The 120/240 V back-up output needs GoodWe's separate auto-transformer. Revised on 16 October 2026: GoodWe prints the A-BP/A-ES output as 240 V line to line; its manual says "The back-up function needs the addition of a GoodWe auto-transformer for 120V back-up loads." The earlier text "Split phase, 120/240 Vac" described the output with that separate add-on (PM ruling 2026-10-16: such units are not listed as 120/240 V).
Where: PDF page 41; PDF page 21
[2]
Enclosure ratingType 4X
Printed as "Ingress Protection Rating Type 4X" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe A-BP Series datasheet, Technical Data, General data table, merged cell
[1]
Surge duration s60 s
Printed as "Peak Output Apparent Power@240V (VA) *2 9120, 60sec 10320, 60sec 11520, 60sec" in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026. Same 60 s duration for every model in the series.
Where: A-BP User Manual, 3.4.1, AC Output Data (Back-up), Peak Output Apparent Power row
[2]
Apparent power8,600 VA
Printed as "Nominal Apparent Power Output to Utility Grid (VA) 5000 6000 7000 7600 8600 9600" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), AC Output (On-grid) table, GW8600A-BP column, captured on September 25, 2026. Apparent power in volt-amperes as printed; GoodWe prints no AC output rating in W for this model.
Where: GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Technical Data, AC Output (On-grid) table, Nominal Apparent Power Output to Utility Grid (VA) row, GW8600A-BP column
[1]
Battery output9.03 kW
Converted: 9,030 W / 1000 = 9.03 kW
Printed as "Max. Discharging Power (W) 5250 6300 7350 7980 9030 10080" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Battery input table, GW8600A-BP column, captured on September 25, 2026. Maximum battery discharging power as printed.
Where: GoodWe A-BP Series datasheet, Technical Data, Battery input table, GW8600A-BP column
Sources
Converted: 9,030 W / 1000 = 9.03 kW
[1]
Battery wire size#6 AWG copper, 90°C (THHN, THWN-2, XHHW, or RHH)
Printed as "The maximum battery current is 50A; please use 90°C, #6 AWG copper building wire (e.g., THHN, THWN-2, XHHW, or RHH wire)." in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026. Same for every model in the series.
Where: A-BP User Manual, Battery wiring connection process
[2]
Nominal voltage360 V
Printed as "Nominal Battery Voltage (V) 360" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe A-BP Series datasheet, Technical Data, Battery input table, merged cell
[1]
Grid passthrough40 A
Printed as "Max. AC Current From Utility Grid (A) 38 40 40" in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026.
Where: A-BP User Manual, 3.4.1, AC Output Data (On-grid), Max. AC Current From Utility Grid row, GW8600A-BP column
[2]
Max grid chargeUnknown
GoodWe prints the power the GW8600A-BP draws from the grid only as apparent power ("Max. Apparent Power from Utility Grid (VA) 6000 7200 8400 9120 9600 9600"), not as a battery charging power from the grid in W or kW, so this field stays unknown. Revised on 12 October 2026: this kilowatt field held the volt-ampere figure (unit VA); the VA figure is kept in this note.
Where: GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Technical Data, AC Output (On-grid) table, GW8600A-BP column
[1]
Night consumption20 W
Printed as "<20"; the figure is an upper bound.
Printed as "Self-consumption at Night (W)*3 <20" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026. Its footnote *3 reads "No Back-up Output."
Where: GoodWe A-BP Series datasheet, Technical Data, General data table, merged cell
[1]
Continuous outputUnknown
GoodWe prints the AC output of the GW8600A-BP only as apparent power ("Nominal Apparent Power Output to Utility Grid (VA) 5000 6000 7000 7600 8600 9600"), with no rating in W or kW, so the real power output stays unknown. Revised on 12 October 2026: this kilowatt field held the volt-ampere figure (unit VA); the VA figure is now recorded under apparent power.
Where: GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Technical Data, AC Output (On-grid) table, GW8600A-BP column
[1]
Battery compatibilityLi-ion batteries compatible with the A-BP series, nominal voltage 80-495 V; the manufacturer's compatible-battery list is published in the SolarGo app, not in this manual.
Printed as "For A-BP series inverter, it could connect lithium batteries which have compatibility with A-BP series inverter with nominal voltage from 80V to 495V. For compatible lithium batteries please refer to battery list in SolarGo App." in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026.
Where: A-BP User Manual, FAQ, About Battery Operation
[2]
Standby consumptionUnknown
GoodWe prints no standby consumption figure for this model in the GoodWe A-BP Series datasheet; its "Self-consumption at Night" row is recorded as night consumption. Revised on 30 September 2026: The 20 W figure is printed as consumption at night ("Self-consumption at Night"), not as standby consumption; it moves to night consumption and standby consumption is unknown.
Where: GoodWe A-BP Series datasheet, Technical Data, General data table, merged cell
[1]
Battery efficiency96.6 %
Printed as "Max. Battery to AC Efficiency 96.6%" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Efficiency table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe A-BP Series datasheet, Technical Data, Efficiency table, merged cell
[1]
Battery voltage range80 to 495 V
Printed as "Battery Voltage Range (V)*1 80 ~ 495" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe A-BP Series datasheet, Technical Data, Battery input table, merged cell
[1]
Operating temperature-35 to 60 °C / -31 to 140 °F converted
Printed as "Operating Temperature Range -31°F ~ +140°F (-35°C ~ +60°C)" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe A-BP Series datasheet, Technical Data, General data table, merged cell
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

AC output (VA)
8,600 VA
Battery voltage
80 to 495 V
Solar input
Not statedMPPT trackers Not stated
AC output
240 V (L1-L2)
Warranty
10 years
Size
57.37 L* (Calculated from published dimensions)W: 415 × H: 790 × D: 175 mm / W: 16.3 × H: 31.1 × D: 6.89 inWeight 32 kg / 71 lb

Evidence score

41/100Missing details90% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

CertificatesUL 1741 SB · UL1741 SA +11Claimed14.2 / 45.0

Manufacturer claim; issuer verification pending. Applies to the exact inverter.

[3]

Warranty term10 years12.0 / 30.0

10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "10 years *limited warranty for on-grid inverters including A-MS, MS G3 US, SMT-US, LV-SMT-US series, hybrid inverters including: A-ES, A-BP , ES US, SBP US series" in the GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930, captured on September 25, 2026. The policy names the A-BP series, not individual models; exclusions, claim steps and the start-date rule apply.

[4]

Battery conversion efficiency96.6 %14.8 / 15.0

96.6 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10

Printed as "Max. Battery to AC Efficiency 96.6%" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Efficiency table, one value printed for every model in the table, captured on September 25, 2026.

[1]

Research pending, 0 points: Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
California Rule 21manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Printed as "California Rule 21" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
CSA 22.2 No. 107-01manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Printed as "CSA 22.2 No. 107-01" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
FCC part15 CLASS Bmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Printed as "FCC part15 CLASS B" in the "Electromagnetic Compatibility" row of the Certification table ("Electromagnetic Compatibility FCC part15 CLASS B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
HECO Rule 14manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Printed as "HECO Rule 14" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEEE 1547manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Printed as "IEEE 1547" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEEE 1547.1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Printed as "IEEE 1547.1" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL1699Bmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Printed as "UL1699B" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Printed as "UL 1741" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL1741 SAmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Printed as "UL1741 SA" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1998manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Printed as "UL 1998" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL991manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Printed as "UL991" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1741 SAauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as GoodWe Technologies Co., Ltd. "GW8600A-BP {240V}": UL 1741 SA, certifying entity CSA Group, certificate date 2021-09-17, CEC listing date 2021-01-21. A state equipment list entry, not the certification body's own record.
Record detail
Issued: Not stated
Valid from: Sep 17, 2021
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[3]
UL 1741 SBauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as GoodWe Technologies Co., Ltd. "GW8600A-BP {240V}": UL 1741 SB, certifying entity CSA Group, certificate date 2021-11-30, CEC listing date 2021-01-21. A state equipment list entry, not the certification body's own record.
Record detail
Issued: Not stated
Valid from: Nov 30, 2021
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[3]
CECauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
GW8600A-BP
Limitations
Model GW8600A-BP listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under GoodWe Technologies Co., Ltd., as "GW8600A-BP {240V}", CEC listing date 2021-01-21. This is an equipment listing, not UL certification or complete-system approval.
Record detail
Issued: Not stated
Valid from: Jan 21, 2021
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[3]

Warranty

FieldValueConditionsSource
TerritoryUSA and Canada
Printed as "GOODWE Limited Warranty for Inverter System (for USA/CANADA market)" in the policy title, captured on September 25, 2026.
Where: Title
[4]
Start basisEarlier of first site commissioning, or 3 months after shipment from the GoodWe USA warehouse (6 months after shipment from the GoodWe China warehouse)
Printed as "starting from the earlier one of following two dates: 1. The date on which the product was first site commissioned. 2. 3 months after the date of product shipment from GOODWE USA warehouse (or 6 months after the date of product shipment from GOODWE China warehouse)." in the same policy, captured on September 25, 2026.
Where: Overview, start-date clause
[4]
Warranty term10 years
Printed as "10 years *limited warranty for on-grid inverters including A-MS, MS G3 US, SMT-US, LV-SMT-US series, hybrid inverters including: A-ES, A-BP , ES US, SBP US series" in the GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930, captured on September 25, 2026. The policy names the A-BP series, not individual models; exclusions, claim steps and the start-date rule apply.
Where: Overview, item 1
[4]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • GoodWe A-BP Series User Manual (EN, V1.4-2023-01-30)Official · GoodWe · Official instruction manual · January 30, 2023 · Web page
    Source details
    Revision
    V1.4
    Revision date
    January 30, 2023

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-27.

    Location: 3.4.1 Inverter Specification (Technical Data tables); Battery wiring connection process

    Retrieved Sep 26, 2026

    GoodWe's own installation and operation manual for the A-BP series AC-coupled retrofit inverter (GW5000A-BP through GW9600A-BP), captured from us.goodwe.com on September 27, 2026. Covers US split-phase models only.

    Archived copies

    Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupV1.4 · 6.09 MB

    Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Skippower/downloadFileF?id=563&mid=60. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2023-01-30

    Embedded creation date
    Embedded modification date
    Pages
    52

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: b7841c3671db300224cd65a5b8a30e3924112c0e81a9c8e4bba8b79ef2fb0210

    Open
  • Datasheets

  • GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)Official · GoodWe · Official datasheet · PDF
    Certificate & compliance claims (11)
    UL1741 SAManufacturer claim · equipment listingClaimedListed when checked

    Printed as "UL1741 SA" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.

    Manufacturer document

    Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
    California Rule 21Manufacturer claim · equipment listingClaimedListed when checked

    Printed as "California Rule 21" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.

    Manufacturer document

    Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
    HECO Rule 14Manufacturer claim · equipment listingClaimedListed when checked

    Printed as "HECO Rule 14" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.

    Manufacturer document

    Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
    IEEE 1547Manufacturer claim · equipment listingClaimedListed when checked

    Printed as "IEEE 1547" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.

    Manufacturer document

    Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
    IEEE 1547.1Manufacturer claim · equipment listingClaimedListed when checked

    Printed as "IEEE 1547.1" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.

    Manufacturer document

    Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
    UL 1741Manufacturer claim · equipment listingClaimedListed when checked

    Printed as "UL 1741" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.

    Manufacturer document

    Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
    CSA 22.2 No. 107-01Manufacturer claim · equipment listingClaimedListed when checked

    Printed as "CSA 22.2 No. 107-01" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.

    Manufacturer document

    Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
    UL 1998Manufacturer claim · equipment listingClaimedListed when checked

    Printed as "UL 1998" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.

    Manufacturer document

    Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
    UL991Manufacturer claim · equipment listingClaimedListed when checked

    Printed as "UL991" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.

    Manufacturer document

    Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
    UL1699BManufacturer claim · equipment listingClaimedListed when checked

    Printed as "UL1699B" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.

    Manufacturer document

    Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
    FCC part15 CLASS BManufacturer claim · equipment listingClaimedListed when checked

    Printed as "FCC part15 CLASS B" in the "Electromagnetic Compatibility" row of the Certification table ("Electromagnetic Compatibility FCC part15 CLASS B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.

    Manufacturer document

    Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
    Source details
    Revision
    GoodWe-Single page-20250205-US-EN-V2.1
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Technical Data table, one column per model

    Retrieved Sep 24, 2026

    GoodWe family datasheet (A-BP Series), fetched from us.goodwe.com (the file the series page us.goodwe.com/a-bp-series-ac-coupled-retrofit-inverter-for-north-america links as "Datasheet") and archived on September 25, 2026. Its Technical Data table sets the models side by side, one column per model, so each figure is read from the named model column and the whole row is quoted; a value printed once spans every column. It names models, not ordering SKUs. It is a manufacturer claim; no figure was tested independently.

    Archived copies

    Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupGoodWe-Single page-20250205-US-EN-V2.1 · 0.52 MB

    Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Ftp/EN/Downloads/Datasheet/GW_A-BP_Datasheet-EN.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: cf2f1b853dc0767c5fe419304828a3fe5996642d6194e3f5d76569b1f7c9ef3a

    Open
  • Warranty

  • GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930Official · GoodWe · Official warranty · September 30, 2025 · PDF
    Source details
    Revision
    Rev 2.0 20250930
    Revision date
    September 30, 2025

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Overview, item 1, and the start-date clause

    Retrieved Sep 24, 2026

    GoodWe limited warranty for inverters sold in the USA and Canada, fetched from us.goodwe.com (linked from us.goodwe.com/warranty as "USA & Canada Warranty") and archived on September 25, 2026. It names series, not models: 10 years for on-grid inverters of the A-MS, MS G3 US, SMT-US and LV-SMT-US series and hybrid inverters of the A-ES, A-BP, ES US and SBP US series. Coverage terms, exclusions and claim steps apply; it is the manufacturer's published policy, not a purchaser-specific contract.

    Archived copies

    Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRev 2.0 20250930 · 0.47 MB

    Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Ftp/Downloads/Warranty/GOODWE%20Limited%20Warranty%20for%20Inverter%20System-US&CA.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2025-09-30

    Embedded creation date
    Embedded modification date
    Pages
    3

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 99433bc9d7f3562a66ab25d1afbfef3e8fe0119b722be112a7bd41b7281b31b7

    Open
  • Other documents

  • GoodWe GW5000A-BP product identityOfficial · GoodWe · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Revision date not established.

    Location: Original source record

    Retrieved Sep 15, 2026

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • GoodWe USA: A-BP Series AC-coupled retrofit inverter for North AmericaOfficial · GoodWe · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Product image (page share image)

    Retrieved Sep 24, 2026

    GoodWe USA series page for the A-BP inverters, captured on September 25, 2026 for its product image; one photograph is published for the whole series (GW5000A-BP to GW9600A-BP), so it does not show a specific power rating.

    Open

Archived documents

GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)

Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupGoodWe-Single page-20250205-US-EN-V2.1 · 0.52 MB

Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Ftp/EN/Downloads/Datasheet/GW_A-BP_Datasheet-EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: cf2f1b853dc0767c5fe419304828a3fe5996642d6194e3f5d76569b1f7c9ef3a

GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930

Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRev 2.0 20250930 · 0.47 MB

Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Ftp/Downloads/Warranty/GOODWE%20Limited%20Warranty%20for%20Inverter%20System-US&CA.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2025-09-30

Embedded creation date
Embedded modification date
Pages
3

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 99433bc9d7f3562a66ab25d1afbfef3e8fe0119b722be112a7bd41b7281b31b7

GoodWe A-BP Series User Manual (EN, V1.4-2023-01-30)

Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupV1.4 · 6.09 MB

Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Skippower/downloadFileF?id=563&mid=60. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2023-01-30

Embedded creation date
Embedded modification date
Pages
52

Embedded dates are file metadata, not independent proof of publication.

SHA-256: b7841c3671db300224cd65a5b8a30e3924112c0e81a9c8e4bba8b79ef2fb0210

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
GW8600A-BP
  1. Observed Oct 11, 2026

    UL 1741 SA: claimed

    Product / system scope unresolved. Listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as GoodWe Technologies Co., Ltd. "GW8600A-BP {240V}": UL 1741 SA, certifying entity CSA Group, certificate date 2021-09-17, CEC listing date 2021-01-21. A state equipment list entry, not the certification body's own record.

    [3]

  2. Observed Oct 11, 2026

    UL 1741 SB: claimed

    Product / system scope unresolved. Listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as GoodWe Technologies Co., Ltd. "GW8600A-BP {240V}": UL 1741 SB, certifying entity CSA Group, certificate date 2021-11-30, CEC listing date 2021-01-21. A state equipment list entry, not the certification body's own record.

    [3]

  3. Observed Oct 11, 2026

    CEC: claimed

    Product / system scope unresolved. Model GW8600A-BP listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under GoodWe Technologies Co., Ltd., as "GW8600A-BP {240V}", CEC listing date 2021-01-21. This is an equipment listing, not UL certification or complete-system approval.

    [3]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 90
basis: Unknown
missing:
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 31.5
unit: Unknown
shown: UL 1741 SB · UL1741 SA +11
shown detail: Claimed
state: claimed
points: 14.2
ceiling: 45
weight: 45
share: 31.5
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Manufacturer claim; issuer verification pending. Applies to the exact inverter.
display note: Unknown
Sources: [3]
key: warranty
label: Warranty term
value: 10
unit: Unknown
shown: 10 years
shown detail: Unknown
state: documented
points: 12
ceiling: 30
weight: 30
share: 40
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [4]
key: efficiency
label: Battery conversion efficiency
value: 96.6
unit: Unknown
shown: 96.6 %
shown detail: Unknown
state: documented
points: 14.8
ceiling: 15
weight: 15
share: 98.4
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1) (GoodWe · manufacturer · GoodWe-Single page-20250205-US-EN-V2.1 · observed Sep 24, 2026)
  2. GoodWe A-BP Series User Manual (EN, V1.4-2023-01-30) (GoodWe · manufacturer · V1.4 · observed Sep 26, 2026)
  3. CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
  4. GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930 (GoodWe · manufacturer · Rev 2.0 20250930 · observed Sep 24, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details