Printed as "Cell Type LFP (LiFePO4)" in the GoodWe Lynx C Series datasheet (footer dated 2023-07-11, V2.1), Battery system table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe Lynx C Series datasheet, Technical Data, Battery system table, merged cell
Connect the PE cable first; customer-supplied single-core copper cable, 8 mm2
Printed as "Connect the PE cable first before electrical connection."; "The PE cable should be prepared by customers."; "The cross-sectional area of the PE cable conductor: 8mm2." in the GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22) (page 24, 6.2 Connecting PE Cable; Cable Requirements table).
Where: PDF page 24, 6.2 Connecting PE Cable; Cable Requirements table
Printed as "Weight (kg) 1120 1280 1480 1650" in the GoodWe Lynx C Series datasheet (footer dated 2023-07-11, V2.1), General data table, LX C138-10 column, captured on September 25, 2026.
Where: GoodWe Lynx C Series datasheet, Technical Data, General data table, LX C138-10 column
Printed as "Cycle Life*3 4000"; "Based on 2.5~3.65V voltage rang @25±2℃ of Cell"; "0.5C/0.5C test condition and 100%DOD 80% EOL." in the GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22) (page 35, 09 Parameters, Technical Data, Cycle Life row and footnote *3). Footnote *3 bases the figure on the cell, not the system.
Where: PDF page 35, 09 Parameters, Technical Data, Cycle Life row and footnote *3
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "PCU Quantity Battery Cabinet Quantity Battery Module Quantity LX C101-10 1 1 11 LX C120-10 1 1 13 LX C138-10 1 1 15 LX C156-10 1 1 17" in the GoodWe Lynx C User Manual (V1.3, 2025-07-22), 3 System Overview, captured September 27, 2026. Classified as "industrial-cabinet" to match the manual's own "Battery Cabinet" terminology for this floor-standing commercial enclosure.
Location: 3 System Overview, BS configuration table
Communications
CAN; RS485
Printed as "Communication CAN+RS485 Weight (Kg)" in the GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22) (page 35, 09 Parameters, Technical Data, Communication row).
Where: PDF page 35, 09 Parameters, Technical Data, Communication row
Printed as "Ingress Protection Rating IP21" in the GoodWe Lynx C Series datasheet (footer dated 2023-07-11, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe Lynx C Series datasheet, Technical Data, General data table, merged cell
1000 V PV cable: 35 mm2 for ETC/BTC series inverters, 25 mm2 for ET 40-50 kW inverters
Printed as "PV cable that meets 1000V standard."; "The cross-sectional area of the power cable is 35mm2"; "The cross-sectional area of the power cable is 25mm2" in the GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22) (pages 20, 27, 28, 06 Electrical Connection, Cable Requirements table; 6.6 and 6.7 notices). Section 6.6 covers ETC/BTC series inverters (35 mm2) and section 6.7 ET 40-50 kW inverters (25 mm2).
Where: PDF pages 20, 27, 28, 06 Electrical Connection, Cable Requirements table; 6.6 and 6.7 notices
Printed as "Usable Energy (kWh)* 1 138.24 156.67" in GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22), 09 Parameters, Technical Data, Usable Energy (kWh) row, LX C138-10 column. Revised on 1 October 2026: The user manual prints a usable energy of 138.24 kWh for this model.
Printed as "QF1 Main circuit breaker The main circuit breaker for the BS." in the GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22) (page 11, 3.3 PCU parts table).
Printed as "Cell Configuration 180S2P 204S2P" in the GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22) (page 35, 09 Parameters, Technical Data, Cell Configuration row). The LX C138-10 value is the first of the two columns of the Technical Data table on that page.
Not printed for this model. GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22), 09 Parameters, Technical Data, Usable Energy row, LX C138-10 column prints "Usable Energy (kWh)* 1 138.24 156.67". Revised on 1 October 2026: The documents print only usable energy for this battery system, not a nominal or rated energy.
COM: external COM port to the inverter; BMU COM: internal COM port to the battery modules
Printed as "COM External COM port To connect the inverter for communication."; "BMU COM Internal COM port To connect the battery module for communication." in the GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22) (page 11, 3.3 PCU parts table; 6.3 notice).
Where: PDF page 11, 3.3 PCU parts table; 6.3 notice
Printed as "Nominal Dis-/Charge Current (A)*2 100" in GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22), 09 Parameters, Technical Data, Nominal Dis-/Charge Current (A) row, one value for both models in the table. Revised on 1 October 2026: The user manual prints one nominal charge and discharge current of 100 A and warns not to exceed it.
Where: 09 Parameters, Technical Data, Nominal Dis-/Charge Current (A) row, one value for both models in the table
Charging range, printed as "Operating Temperature Range (°C) Charge: 0 ~ +45; Discharge: -20 ~ +50" in the GoodWe Lynx C Series datasheet (footer dated 2023-07-11, V2.1), captured on September 25, 2026.
Battery cabinet standing vertically on flat ground without risk of inclination
Printed as "Ensure that the ground is flat."; "Ensure that the battery cabinet is vertically standing on the ground without risk of inclination." in the GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22) (page 18, 5.5 Installing the BS, notice).
GoodWe ETC/BTC 50 kW and 100 kW inverters; GoodWe ET 40-50 kW inverters
Printed as "6.1.1 Connecting ETC/BTC 50kW Inverter"; "6.1.2 Connecting ETC/BTC 100kW Inverter"; "6.1.3 ET 40-50kW Inverters Connecting with one Battery System" in the GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22) (page 3, 6.1 Wiring Diagram section headings).
Where: PDF page 3, 6.1 Wiring Diagram section headings
Printed as "Nominal Dis-/Charge Current (A)*2 100" in GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22), 09 Parameters, Technical Data, Nominal Dis-/Charge Current (A) row, one value for both models in the table. Revised on 1 October 2026: The user manual prints one nominal charge and discharge current of 100 A and warns not to exceed it.
Where: 09 Parameters, Technical Data, Nominal Dis-/Charge Current (A) row, one value for both models in the table
Discharging range, printed as "Operating Temperature Range (°C) Charge: 0 ~ +45; Discharge: -20 ~ +50" in the GoodWe Lynx C Series datasheet (footer dated 2023-07-11, V2.1), captured on September 25, 2026.
Printed as "3 CAN2H CAN communication for inverters"; "7 RS485_A1 RS485 communication for inverters" in the GoodWe Lynx C User Manual (EN, V1.3, 2025-07-22) (page 26, 6.5 COMM port pin table).
1,741.1 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 1,155 × H: 2,065 × D: 730 mm / W: 45.47 × H: 81.3 × D: 28.7 in1,480 kg / 3,263 lb0.08 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
17/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
High voltage · Industrial cabinet · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Product warranty on the electronics and enclosure, printed as "1. 10 years of product warranty: GOODWE warrants that the hardware of electronics and enclosure" in the GOODWE Limited Warranty for Lynx Series LX C Battery System (Rev: 1.3 20240205), captured on September 25, 2026. The policy's Geographical Scope clause limits it to devices bought from authorized channels and installed in the international market it defines, which excludes the regions GoodWe covers with separate terms (the United States and Canada among them).
Research pending, 0 points: Certificates, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Retention
70 %
Performance warranty, printed as "GOODWE warrants that, for ten (10) years, the battery system retains either seventy percent (70%) of Usable Energy" in the GOODWE Limited Warranty for Lynx Series LX C Battery System (Rev: 1.3 20240205), captured on September 25, 2026: 70% of usable energy for ten years or until the minimum throughput, whichever comes first. The performance warranty term (10 years) differs from the product warranty term.
Global-market policy; not the United States or Canada
Product warranty on the electronics and enclosure, printed as "1. 10 years of product warranty: GOODWE warrants that the hardware of electronics and enclosure" in the GOODWE Limited Warranty for Lynx Series LX C Battery System (Rev: 1.3 20240205), captured on September 25, 2026. The policy's Geographical Scope clause limits it to devices bought from authorized channels and installed in the international market it defines, which excludes the regions GoodWe covers with separate terms (the United States and Canada among them).
Minimum Through Output Energy, printed as "LX C138-10 138.24 470.02" in the GOODWE Limited Warranty for Lynx Series LX C Battery System (Rev: 1.3 20240205), captured on September 25, 2026.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-27.
Location: 09 Parameters, Technical Data tables
Retrieved Sep 27, 2026
GoodWe's own installation and operation manual for the Lynx C battery cabinet series (LX C101-10, C120-10, C138-10, C156-10), captured from en.goodwe.com on September 27, 2026.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Technical Data table, one column per model
Retrieved Sep 24, 2026
GoodWe family datasheet (Lynx C Series), fetched from en.goodwe.com (the file the series page en.goodwe.com/lynx-c links as "Datasheet") and archived on September 25, 2026. Its Technical Data table sets the models side by side, one column per model, so each figure is read from the named model column and the whole row is quoted; a value printed once spans every column. It names models, not ordering SKUs. It is a manufacturer claim; no figure was tested independently.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Overview and Geographical Scope
Retrieved Sep 24, 2026
GoodWe limited warranty naming the Lynx battery systems LX C101-10, LX C120-10, LX C138-10 and LX C156-10 produced after 1st March 2024. Fetched from en.goodwe.com (linked from en.goodwe.com/warranty) and archived on September 25, 2026. The policy's Geographical Scope clause limits it to devices bought from authorized channels and installed in the international market it defines, which excludes the regions GoodWe covers with separate terms (the United States and Canada among them). It is the manufacturer's published policy, not a purchaser-specific contract.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
GoodWe Lynx C Series datasheet (GoodWe-Single page-20230711-EN-V2.1)
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
GOODWE Limited Warranty for Lynx Series LX C Battery System, Rev: 1.3 20240205
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].