Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Manufacturer family illustration; exact model label/physical revision is not assertedHybrid inverter
GoodWe GW7600-ES-US20
Key specs
Converted: 7,600 W / 1000 = 7.6 kW
2 specs not documented yet: maximum grid charging, standby consumptionHelp fill in ›
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 34.79 kg / 76.7 lb converted | Printed as "Weight (lb) 72.3 72.3 76.7 84.9 84.9" in the GoodWe goodwe spec; the maker prints pounds only, converted to kilograms. Revised on 30 September 2026: The maker prints this weight in pounds only; the stored kilograms were an unlabeled conversion, now labeled with the printed pounds kept (Project Manager, September 30, 2026). Where: GoodWe ES-US Series datasheet, PDF page 3, General Data table, GW7600-ES-US20 (third) column SourcesConverted: 76.7 lb x 0.45359237 kg/lb, rounded to 0.01 kg | [1] |
| MPPT count | 4 | Printed as "Number of MPP Trackers 2 2 4 4 4" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), PV input table, GW7600-ES-US20 column, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, PV input table, GW7600-ES-US20 column | [1] |
| Peak output | 12,920 VA for 10 s (with grid) | Printed as "Max. Output Apparent Power with Grid (VA)*4 5000 (10000@10sec) 6000 (12000@10sec) 7600 (12920@10sec) 9600 (17280@10sec) 11400 (17280@10sec)" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), AC output (back-up) table, GW7600-ES-US20 column, captured on September 25, 2026. The datasheet footnote says this can be reached only if PV and battery power is enough; the row is the backup apparent power with grid, in VA, not W. Where: GoodWe ES-US Series datasheet, Technical Data, AC output (back-up) table, GW7600-ES-US20 column | [1] |
| AC voltage | 240 V (on-grid); 240/120 V (back-up) | Printed as "Nominal Output Voltage (V) 240/120 240/120 240/120 240/120 240/120"; "Nominal Output Voltage (V) 240 240 240 240 240" in GoodWe ES-US, SBP-US User Manual (EN, V1.3-2026-04-09) (PDF page 70; PDF page 69). Revised on 16 October 2026: PM ruling 2026-10-16 (AC voltage field): GoodWe prints the nominal output voltage as 240 V on-grid and 240/120 V on the back-up output; the earlier "240 V" gave only the on-grid line-to-line figure. Where: PDF page 70; PDF page 69 | [2] |
| Max charge | 50 A | Printed as "Max. Continuous Charging Current (A) 50" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, Battery input table, merged cell | [1] |
| Dimensions | W 485 × H 900 × D 191.5 mm / W 19.1 × H 35.4 × D 7.54 in converted | Printed as "Dimension (W × H × D) 19.1 × 35.4 × 7.5 in (485 × 900 × 191.5 mm)" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, General data table, merged cell | [1] |
| Communications | BMS: RS485/CAN; Meter: RS485; Portal: Bluetooth, WiFi, LAN, 4G (optional) | Printed as "Communication with BMS RS485, CAN RS485, CAN RS485, CAN RS485, CAN RS485, CAN Communication with Meter RS485 RS485 RS485 RS485 RS485 Communication with Portal Bluetooth, WiFi, LAN, 4G (Optional)" in the GoodWe ES-US, SBP-US User Manual (V1.3-2026-04-09), captured September 27, 2026. Same for every ES-US model. Where: ES-US User Manual, 10.1, General Data, Communication rows | [2] |
| Efficiency | 97.6 % | Printed as "Max. Efficiency 97.6%" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), Efficiency table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, Efficiency table, merged cell | [1] |
| MPPT voltage | 50 to 550 V | Printed as "MPPT Operating Voltage Range (V)*3 50 ~ 550" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), PV input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, PV input table, merged cell | [1] |
| Solar array | 11.4 kWConverted: 11,400 W / 1000 = 11.4 kW | Printed as "Max. Input Power (W) 7,500 9,000 11,400 14,400 17,100" in the GoodWe ES-US, SBP-US User Manual (V1.3-2026-04-09), captured September 27, 2026. Same figure already recorded under solar_input_kw for this product. Where: ES-US User Manual, 10.1, PV String Input Data, Max. Input Power row, GW7600-ES-US20 column SourcesConverted: 11,400 W / 1000 = 11.4 kW | [2] |
| Solar input | 11.4 kWConverted: 11,400 W / 1000 = 11.4 kW | Printed as "Max. Input Power (W) 7500 9000 11400 14400 17100" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), PV input table, GW7600-ES-US20 column, captured on September 25, 2026. Maximum PV input power; the datasheet footnotes limit how long it may be sustained. Where: GoodWe ES-US Series datasheet, Technical Data, PV input table, GW7600-ES-US20 column SourcesConverted: 11,400 W / 1000 = 11.4 kW | [1] |
| AC frequency | 50 / 60 Hz | Printed as "Nominal AC Grid Frequency (Hz) 50 / 60" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), AC output table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, AC output table, merged cell | [1] |
| Max discharge | 50 A | Printed as "Max. Continuous Discharging Current (A) 50" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, Battery input table, merged cell | [1] |
| AC configuration | Split phase, 120/240 Vac | Printed as "Type of Electrical Supply System Split phase" and "Nominal Output Voltage (V) 240/120 240/120 240/120 240/120 240/120" in the GoodWe ES-US, SBP-US User Manual (V1.3-2026-04-09), captured September 27, 2026. Same for every ES-US model. Where: ES-US User Manual, 10.1, General Data / AC Output Data (Back-up) | [2] |
| Enclosure rating | NEMA Type 4X | Printed as "Ingress Protection Rating NEMA Type 4X" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, General data table, merged cell | [1] |
| Max PV current | 16 A | Printed as "Max. Input Current per MPPT (A) 16 16 16 16 16" in the GoodWe ES-US, SBP-US User Manual (V1.3-2026-04-09), captured September 27, 2026. Same for every ES-US model. Where: ES-US User Manual, 10.1, PV String Input Data, Max. Input Current per MPPT row | [2] |
| Max PV voltage | 600 V | Printed as "Max. Input Voltage (V)*2 600" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), PV input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, PV input table, merged cell | [1] |
| Surge duration s | 60 s | Printed as "Max. Output Apparent Power (VA)*4 5,000 (6,000 @ 60sec) 6000 (7,200 @ 60sec) 7,600 (9,120 @ 60sec) 9,600 (11,520 @ 60sec) 11,400 (13,680 @ 60sec)" in the GoodWe ES-US, SBP-US User Manual (V1.3-2026-04-09), captured September 27, 2026. Same 60 s duration for every ES-US model. Where: ES-US User Manual, 10.1, AC Output Data (Back-up), Max. Output Apparent Power row | [2] |
| Battery output | 7.98 kWConverted: 7,980 W / 1000 = 7.98 kW | Printed as "Max. Discharging Power (W) 5250 6300 7980 10080 11970" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), Battery input table, GW7600-ES-US20 column, captured on September 25, 2026. Maximum battery discharging power as printed. Where: GoodWe ES-US Series datasheet, Technical Data, Battery input table, GW7600-ES-US20 column SourcesConverted: 7,980 W / 1000 = 7.98 kW | [1] |
| Battery wire size | #6 AWG copper, 90°C | Printed as "Battery cable port BAT INPUT • Connect with battery DC cable • The recommended cables are: copper wire, temperature 90℃(194°F), 6AWG" in the GoodWe ES-US, SBP-US User Manual (V1.3-2026-04-09), captured September 27, 2026. Same for every ES-US model. Where: ES-US User Manual, 6.2.2 Cable Specification, Battery cable port row | [2] |
| Nominal voltage | 300 V | Printed as "Nominal Battery Voltage (V) 300" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, Battery input table, merged cell | [1] |
| Grid passthrough | 31.7 A | Printed as "Max. AC Current From Utility Grid (A) 20.8 25.0 31.7 40.0 47.5" in the GoodWe ES-US, SBP-US User Manual (V1.3-2026-04-09), captured September 27, 2026. Where: ES-US User Manual, 10.1, AC Output Data (On-grid), Max. AC Current From Utility Grid row, GW7600-ES-US20 column | [2] |
| Max grid charge | Unknown | GoodWe prints the power the GW7600-ES-US20 draws from the grid only as apparent power ("Max. Apparent Power from Utility Grid (VA) 5,000 6,000 7,600 9,600 11,400" in the GoodWe ES-US, SBP-US User Manual, V1.3-2026-04-09), not as a battery charging power from the grid in W or kW, so this field stays unknown. Revised on 12 October 2026: this kilowatt field held the volt-ampere figure (unit VA); the VA figure is kept in this note. Where: 10.1 ES Inverter Parameters, AC Output Data (On-grid), Max. Apparent Power from Utility Grid (VA) row, GW7600-ES-US20 column | [2] |
| PV start voltage | 60 V | Printed as "Start-up Voltage (V) 60" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), PV input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, PV input table, merged cell | [1] |
| Night consumption | 20 W Printed as "<20"; the figure is an upper bound. | Printed as "Self-consumption at Night (W)*5 <20" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026. Its footnote *5 reads "No Back-up Output." Where: GoodWe ES-US Series datasheet, Technical Data, General data table, merged cell | [1] |
| PV strings per MPPT | 1 | Printed as "Number of Strings per MPPT 1" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), PV input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, PV input table, merged cell | [1] |
| Continuous output | 7.6 kWConverted: 7,600 W / 1000 = 7.6 kW | Printed as "Nominal Output Power (W) 5000 6000 7600 9600 11400" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), AC output table, GW7600-ES-US20 column, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, AC output table, GW7600-ES-US20 column SourcesConverted: 7,600 W / 1000 = 7.6 kW | [1] |
| Battery compatibility | Li-ion batteries, nominal voltage range 80-495 V per the inverter's own Battery Input Data table; this manual prints no separate compatible-battery model list. | Printed as "Battery Voltage Range (V)*1 80~495 80~495 80~495 80~495 80~495" in the GoodWe ES-US, SBP-US User Manual (V1.3-2026-04-09), captured September 27, 2026. Where: ES-US User Manual, 10.1, Battery Input Data | [2] |
| Standby consumption | Unknown | GoodWe prints no standby consumption figure for this model in the GoodWe goodwe spec; its "Self-consumption at Night" row is recorded as night consumption. Revised on 30 September 2026: The 20 W figure is printed as consumption at night ("Self-consumption at Night"), not as standby consumption; it moves to night consumption and standby consumption is unknown. Where: GoodWe ES-US Series datasheet, Technical Data, General data table, merged cell | [1] |
| Max PV input current | 16 A | Max. Input Current per MPPT (A); exact model overview; manufacturer claim Where: Model GW7600-ES-US20 overview table; Max. Input Current per MPPT (A) | [3] |
| Max PV short circuit | 23.4 A | Printed as "Max. Short Circuit Current per MPPT (A) 23.4" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), PV input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, PV input table, merged cell | [1] |
| Battery voltage range | 80 to 495 V | Printed as "Battery Voltage Range (V)*1 80 ~ 495" in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe ES-US Series datasheet, Technical Data, Battery input table, merged cell | [1] |
| Operating temperature | -35 to 60 C / -31 to 140 °F converted | Printed as "Operating Temperature Range (℉) -31℉~+140℉ (-35℃~+60℃)" in the GoodWe ES-US, SBP-US User Manual (V1.3-2026-04-09), captured September 27, 2026. Same for every ES-US model. Where: ES-US User Manual, 10.1, General Data | [2] |
| Backup nominal apparent power | 7,600 VA | Manufacturer apparent power; not a continuous real-watt rating Where: Model GW7600-ES-US20 overview table; row Back-up Nominal Apparent Power (VA) | [3] |
| Maximum apparent AC output power | 7,600 VA | Manufacturer apparent power; not a continuous real-watt rating Where: Model GW7600-ES-US20 overview table; row Max. Apparent Power Output to Utility Grid (VA) | [3] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Continuous output
- 7.6 kWBattery only 7.98 kW
- Battery voltage
- 80 to 495 V
- Solar input
- 11.4 kWMPPT trackers 4MPPT range 50 to 550 V
- AC output
- Split phase, 120/240 Vac
- Warranty
- 10 years
- Size
- 83.59 L* (Calculated from published dimensions)W: 485 × H: 900 × D: 191.5 mm / W: 19.1 × H: 35.4 × D: 7.54 inWeight 34.79 kg / 76.7 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "10 years *limited warranty for on-grid inverters including A-MS, MS G3 US, SMT-US, LV-SMT-US series, hybrid inverters including: A-ES, A-BP , ES US, SBP US series" in the GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930, captured on September 25, 2026. The policy names the ES US series, not individual models; exclusions, claim steps and the start-date rule apply.
Research pending, 0 points: Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it worksCertificates
California Rule 21manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Printed as "California Rule 21" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SB, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
CSA 22.2 No. 107.1manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Printed as "CSA 22.2 No. 107.1" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107.1, UL 1998, UL1699B") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
FCC part15 CLASS Bmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Printed as "FCC part15 CLASS B" in the "Electromagnetic Compatibility" row of the Certification table ("Electromagnetic Compatibility FCC part15 CLASS B") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
HECO Rule 14manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Printed as "HECO Rule 14" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SB, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
IEEE 1547manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Printed as "IEEE 1547" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SB, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
IEEE 1547.1manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Printed as "IEEE 1547.1" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SB, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL1699Bmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Printed as "UL1699B" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107.1, UL 1998, UL1699B") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Printed as "UL 1741" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107.1, UL 1998, UL1699B") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL1741 SBmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Printed as "UL1741 SB" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SB, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1998manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Printed as "UL 1998" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107.1, UL 1998, UL1699B") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741 SBauthority listing reportedlisted as of snapshot[5]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as GoodWe Technologies Co., Ltd. "GW7600-ES-US20 {240V}": UL 1741 SB, certifying entity CSA Group, certificate date 2022-07-19, CEC listing date 2023-01-23. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Jul 19, 2022Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [5]
CECauthority listing reportedlisted as of snapshot[5]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Model GW7600-ES-US20 listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under GoodWe Technologies Co., Ltd., as "GW7600-ES-US20 {240V}", CEC listing date 2023-01-23. This is an equipment listing, not UL certification or complete-system approval.
- Record detail
- Issued: Not statedValid from: Jan 23, 2023Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [5]
CECauthority listing reportedlisted as of snapshot[5]
- Scope
- equipment listing
- Covered models
- GW7600-ES-US20
- Limitations
- Model GW7600-ES-US20 listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under GoodWe Technologies Co., Ltd., as "GW7600-ES-US20 {240V}", CEC listing date 2023-01-23. This is an equipment listing, not UL certification or complete-system approval.
- Record detail
- Issued: Not statedValid from: Jan 23, 2023Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [5]
Warranty
| Field | Value | Conditions | Source |
|---|---|---|---|
| Territory | USA and Canada | Printed as "GOODWE Limited Warranty for Inverter System (for USA/CANADA market)" in the policy title, captured on September 25, 2026. Where: Title | [4] |
| Start basis | Earlier of first site commissioning, or 3 months after shipment from the GoodWe USA warehouse (6 months after shipment from the GoodWe China warehouse) | Printed as "starting from the earlier one of following two dates: 1. The date on which the product was first site commissioned. 2. 3 months after the date of product shipment from GOODWE USA warehouse (or 6 months after the date of product shipment from GOODWE China warehouse)." in the same policy, captured on September 25, 2026. Where: Overview, start-date clause | [4] |
| Warranty term | 10 years | Printed as "10 years *limited warranty for on-grid inverters including A-MS, MS G3 US, SMT-US, LV-SMT-US series, hybrid inverters including: A-ES, A-BP , ES US, SBP US series" in the GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930, captured on September 25, 2026. The policy names the ES US series, not individual models; exclusions, claim steps and the start-date rule apply. Where: Overview, item 1 | [4] |
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- GoodWe ES-US, SBP-US User Manual (EN, V1.3-2026-04-09)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-27.
Location: 10.1 ES Inverter Parameters (Technical Data tables); 6.2.2 Cable Specification
Retrieved Sep 26, 2026
GoodWe's own installation and operation manual for the ES-US hybrid inverter series (GW5000-ES-US20, GW6000-ES-US20, GW7600-ES-US20, GW9600-ES-US20, GW11K4-ES-US20) and the SBP-US AC-coupled series, captured from us.goodwe.com on September 27, 2026. Only the ES-US section (10.1 ES Inverter Parameters) is used here.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupV1.3 · 14.96 MBArchived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Skippower/downloadFileF?id=1219&mid=60. Copyright and takedown
File details
Original sourcePrinted revision date: 2026-04-09
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 4f64a2524403d9909a883bb9d37a3ec18cff2bda1322a3be901dd5c7140cde06
Datasheets
- GoodWe goodwe specOpen
Certificate & compliance claims (10)
UL1741 SBManufacturer claim · equipment listingClaimedListed when checked
Printed as "UL1741 SB" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SB, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe goodwe specCalifornia Rule 21Manufacturer claim · equipment listingClaimedListed when checked
Printed as "California Rule 21" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SB, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe goodwe specHECO Rule 14Manufacturer claim · equipment listingClaimedListed when checked
Printed as "HECO Rule 14" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SB, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe goodwe specIEEE 1547Manufacturer claim · equipment listingClaimedListed when checked
Printed as "IEEE 1547" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SB, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe goodwe specIEEE 1547.1Manufacturer claim · equipment listingClaimedListed when checked
Printed as "IEEE 1547.1" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SB, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe goodwe specUL 1741Manufacturer claim · equipment listingClaimedListed when checked
Printed as "UL 1741" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107.1, UL 1998, UL1699B") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe goodwe specCSA 22.2 No. 107.1Manufacturer claim · equipment listingClaimedListed when checked
Printed as "CSA 22.2 No. 107.1" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107.1, UL 1998, UL1699B") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe goodwe specUL 1998Manufacturer claim · equipment listingClaimedListed when checked
Printed as "UL 1998" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107.1, UL 1998, UL1699B") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe goodwe specUL1699BManufacturer claim · equipment listingClaimedListed when checked
Printed as "UL1699B" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107.1, UL 1998, UL1699B") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe goodwe specFCC part15 CLASS BManufacturer claim · equipment listingClaimedListed when checked
Printed as "FCC part15 CLASS B" in the "Electromagnetic Compatibility" row of the Certification table ("Electromagnetic Compatibility FCC part15 CLASS B") in the GoodWe ES-US Series datasheet (footer dated 2026-09-01, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe goodwe specSource details
Retrieved Sep 10, 2026
SHA-256: ee560496c45cd2a49490560d5eec3d1e02b056e25971f3e789b7473b152e96fa
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupUS-EN-V1.1 · 0.59 MBArchived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Skippower/downloadFileF?id=1207&mid=60. Copyright and takedown
File details
Original sourcePrinted revision date: 2025-09-01
Embedded dates are file metadata, not independent proof of publication.
SHA-256: ee560496c45cd2a49490560d5eec3d1e02b056e25971f3e789b7473b152e96fa
Warranty
- GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Overview, item 1, and the start-date clause
Retrieved Sep 24, 2026
GoodWe limited warranty for inverters sold in the USA and Canada, fetched from us.goodwe.com (linked from us.goodwe.com/warranty as "USA & Canada Warranty") and archived on September 25, 2026. It names series, not models: 10 years for on-grid inverters of the A-MS, MS G3 US, SMT-US and LV-SMT-US series and hybrid inverters of the A-ES, A-BP, ES US and SBP US series. Coverage terms, exclusions and claim steps apply; it is the manufacturer's published policy, not a purchaser-specific contract.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRev 2.0 20250930 · 0.47 MBArchived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Ftp/Downloads/Warranty/GOODWE%20Limited%20Warranty%20for%20Inverter%20System-US&CA.pdf. Copyright and takedown
File details
Original sourcePrinted revision date: 2025-09-30
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 99433bc9d7f3562a66ab25d1afbfef3e8fe0119b722be112a7bd41b7281b31b7
Other documents
- GoodWe GW9600-ES-US20 product identityOpen
Source details
Revision date not established.
Location: Original source record
Retrieved Sep 15, 2026
Archive and older revisions
Archive and older revisions0
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
GoodWe goodwe spec
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Skippower/downloadFileF?id=1207&mid=60. Copyright and takedown
File details
Original sourcePrinted revision date: 2025-09-01
Embedded dates are file metadata, not independent proof of publication.
SHA-256: ee560496c45cd2a49490560d5eec3d1e02b056e25971f3e789b7473b152e96fa
GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Ftp/Downloads/Warranty/GOODWE%20Limited%20Warranty%20for%20Inverter%20System-US&CA.pdf. Copyright and takedown
File details
Original sourcePrinted revision date: 2025-09-30
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 99433bc9d7f3562a66ab25d1afbfef3e8fe0119b722be112a7bd41b7281b31b7
GoodWe ES-US, SBP-US User Manual (EN, V1.3-2026-04-09)
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Skippower/downloadFileF?id=1219&mid=60. Copyright and takedown
File details
Original sourcePrinted revision date: 2026-04-09
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 4f64a2524403d9909a883bb9d37a3ec18cff2bda1322a3be901dd5c7140cde06
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- GW7600-ES-US20
Observed Oct 11, 2026
UL 1741 SB: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as GoodWe Technologies Co., Ltd. "GW7600-ES-US20 {240V}": UL 1741 SB, certifying entity CSA Group, certificate date 2022-07-19, CEC listing date 2023-01-23. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model GW7600-ES-US20 listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under GoodWe Technologies Co., Ltd., as "GW7600-ES-US20 {240V}", CEC listing date 2023-01-23. This is an equipment listing, not UL certification or complete-system approval.
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model GW7600-ES-US20 listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under GoodWe Technologies Co., Ltd., as "GW7600-ES-US20 {240V}", CEC listing date 2023-01-23. This is an equipment listing, not UL certification or complete-system approval.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 75 basis: Unknown missing: Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 31.5 unit: Unknown shown: UL1741 SB · California Rule 21 +9 shown detail: Claimed state: claimed points: 14.2 ceiling: 45 weight: 45 share: 31.5 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown Sources: [1] key: warranty label: Warranty term value: 10 unit: Unknown shown: 10 years shown detail: Unknown state: documented points: 12 ceiling: 30 weight: 30 share: 40 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [4] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- GoodWe goodwe spec (GoodWe · manufacturer · US-EN-V1.1 · observed Sep 10, 2026)
- GoodWe ES-US, SBP-US User Manual (EN, V1.3-2026-04-09) (GoodWe · manufacturer · V1.3 · observed Sep 26, 2026)
- GoodWe GW9600-ES-US20 product identity (GoodWe · manufacturer · observed Sep 15, 2026)
- GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930 (GoodWe · manufacturer · Rev 2.0 20250930 · observed Sep 24, 2026)
- CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
Sign in to report an error on this page
Similar products
All with a priceGoodWe GW11K4-ES-US20
GoodWe GEH7.6-1U-US10 Hybrid Inverter
GoodWe GEH7.0-1U-US10 Hybrid Inverter
GoodWe GEH8.6-1U-US10 Hybrid Inverter
* Missing details