Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: GoodWe A-BP series front view, published by GoodWe on its North American A-BP series page; one photograph is published for the series.Inverter charger
GoodWe GW7000A-BP
Key specs
3 specs not documented yet: maximum grid charging, continuous output, standby consumptionHelp fill in ›
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 32 kg / 71 lb converted | Printed as "Weight 62.8lb (28.5kg) 62.8lb (28.5kg) 70.5lb (32kg) 70.5lb (32kg) 70.5lb (32kg) 70.5lb (32kg)" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), General data table, GW7000A-BP column, captured on September 25, 2026. Where: GoodWe A-BP Series datasheet, Technical Data, General data table, GW7000A-BP column | [1] |
| Peak output | 8,400 VA for 60 s (backup output) | Printed as "Max. Output Apparent Power (VA)*2 5000 (6000@60sec) 6000 (7200@60sec) 7000 (8400@60sec) 7600 (9120@60sec) 8600 (10320@60sec) 9600 (11520@60sec)" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), AC output (back-up) table, GW7000A-BP column, captured on September 25, 2026. The datasheet footnote says this can be reached only if battery power is enough; the figure is backup apparent power in VA, not W. Where: GoodWe A-BP Series datasheet, Technical Data, AC output (back-up) table, GW7000A-BP column | [1] |
| AC voltage | 240 V | Printed as "Nominal Output Voltage (V) 240" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), AC output table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe A-BP Series datasheet, Technical Data, AC output table, merged cell | [1] |
| Max charge | 50 A | Printed as "Max. Continuous Charging Current (A) 50" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe A-BP Series datasheet, Technical Data, Battery input table, merged cell | [1] |
| Dimensions | W 415 × H 790 × D 175 mm / W 16.3 × H 31.1 × D 6.89 in converted | Printed as "Dimension (W × H × D) 16.3 × 31.1 × 6.9 in (415 × 790 × 175 mm)" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe A-BP Series datasheet, Technical Data, General data table, merged cell | [1] |
| Communications | BMS: RS485/CAN; Meter: RS485; EMS: RS485 (insulated); Portal: WiFi, LAN (optional) | Printed as "Communication with BMS RS485; CAN Communication with Meter RS485 Communication with EMS RS485 (Insulated) Communication with Portal Wi-Fi; LAN (Optional)" in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026. Same for every model in the series. Where: A-BP User Manual, 3.4.1, General Data, Communication rows | [2] |
| Efficiency | 96.6 % | Printed as "Battery Charge/Discharge to AC Max Efficiency 96.6%" in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026. The A-BP is an AC-coupled retrofit inverter with no PV input; this battery-charge/discharge-to-AC figure is the only efficiency the manual publishes. Where: A-BP User Manual, 3.4.1, Efficiency table | [2] |
| AC frequency | 60 Hz | Printed as "Nominal AC Grid Frequency (Hz) 60" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), AC output table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe A-BP Series datasheet, Technical Data, AC output table, merged cell | [1] |
| Max discharge | 50 A | Printed as "Max. Continuous Discharging Current (A) 50" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe A-BP Series datasheet, Technical Data, Battery input table, merged cell | [1] |
| AC configuration | 240 V (L1-L2) | Printed as "Output Voltage Range (V) 211 to 264 @240"; "Nominal Output Voltage L1-L2/L- N(Vac) 240/120"; "The back-up function needs the addition of a GoodWe auto-transformer for 120V back-up loads." in GoodWe A-BP Series User Manual (EN, V1.4-2023-01-30) (PDF page 41; PDF page 21). The 120/240 V back-up output needs GoodWe's separate auto-transformer. Revised on 16 October 2026: GoodWe prints the A-BP/A-ES output as 240 V line to line; its manual says "The back-up function needs the addition of a GoodWe auto-transformer for 120V back-up loads." The earlier text "Split phase, 120/240 Vac" described the output with that separate add-on (PM ruling 2026-10-16: such units are not listed as 120/240 V). Where: PDF page 41; PDF page 21 | [2] |
| Enclosure rating | Type 4X | Printed as "Ingress Protection Rating Type 4X" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe A-BP Series datasheet, Technical Data, General data table, merged cell | [1] |
| Surge duration s | 60 s | Printed as "Peak Output Apparent Power@240V (VA) *2 6000, 60sec 7200, 60sec 8400, 60sec" in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026. Same 60 s duration for every model in the series. Where: A-BP User Manual, 3.4.1, AC Output Data (Back-up), Peak Output Apparent Power row | [2] |
| Apparent power | 7,000 VA | Printed as "Nominal Apparent Power Output to Utility Grid (VA) 5000 6000 7000 7600 8600 9600" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), AC Output (On-grid) table, GW7000A-BP column, captured on September 25, 2026. Apparent power in volt-amperes as printed; GoodWe prints no AC output rating in W for this model. Where: GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Technical Data, AC Output (On-grid) table, Nominal Apparent Power Output to Utility Grid (VA) row, GW7000A-BP column | [1] |
| Battery output | 7.35 kWConverted: 7,350 W / 1000 = 7.35 kW | Printed as "Max. Discharging Power (W) 5250 6300 7350 7980 9030 10080" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Battery input table, GW7000A-BP column, captured on September 25, 2026. Maximum battery discharging power as printed. Where: GoodWe A-BP Series datasheet, Technical Data, Battery input table, GW7000A-BP column SourcesConverted: 7,350 W / 1000 = 7.35 kW | [1] |
| Battery wire size | #6 AWG copper, 90°C (THHN, THWN-2, XHHW, or RHH) | Printed as "The maximum battery current is 50A; please use 90°C, #6 AWG copper building wire (e.g., THHN, THWN-2, XHHW, or RHH wire)." in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026. Same for every model in the series. Where: A-BP User Manual, Battery wiring connection process | [2] |
| Nominal voltage | 360 V | Printed as "Nominal Battery Voltage (V) 360" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe A-BP Series datasheet, Technical Data, Battery input table, merged cell | [1] |
| Grid passthrough | 35 A | Printed as "Max. AC Current From Utility Grid (A) 25 30 35" in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026. Where: A-BP User Manual, 3.4.1, AC Output Data (On-grid), Max. AC Current From Utility Grid row, GW7000A-BP column | [2] |
| Max grid charge | Unknown | GoodWe prints the power the GW7000A-BP draws from the grid only as apparent power ("Max. Apparent Power from Utility Grid (VA) 6000 7200 8400 9120 9600 9600"), not as a battery charging power from the grid in W or kW, so this field stays unknown. Revised on 12 October 2026: this kilowatt field held the volt-ampere figure (unit VA); the VA figure is kept in this note. Where: GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Technical Data, AC Output (On-grid) table, GW7000A-BP column | [1] |
| Night consumption | 20 W Printed as "<20"; the figure is an upper bound. | Printed as "Self-consumption at Night (W)*3 <20" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026. Its footnote *3 reads "No Back-up Output." Where: GoodWe A-BP Series datasheet, Technical Data, General data table, merged cell | [1] |
| Continuous output | Unknown | GoodWe prints the AC output of the GW7000A-BP only as apparent power ("Nominal Apparent Power Output to Utility Grid (VA) 5000 6000 7000 7600 8600 9600"), with no rating in W or kW, so the real power output stays unknown. Revised on 12 October 2026: this kilowatt field held the volt-ampere figure (unit VA); the VA figure is now recorded under apparent power. Where: GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Technical Data, AC Output (On-grid) table, GW7000A-BP column | [1] |
| Battery compatibility | Li-ion batteries compatible with the A-BP series, nominal voltage 80-495 V; the manufacturer's compatible-battery list is published in the SolarGo app, not in this manual. | Printed as "For A-BP series inverter, it could connect lithium batteries which have compatibility with A-BP series inverter with nominal voltage from 80V to 495V. For compatible lithium batteries please refer to battery list in SolarGo App." in the GoodWe A-BP Series User Manual (V1.4-2023-01-30), captured September 27, 2026. Where: A-BP User Manual, FAQ, About Battery Operation | [2] |
| Standby consumption | Unknown | GoodWe prints no standby consumption figure for this model in the GoodWe A-BP Series datasheet; its "Self-consumption at Night" row is recorded as night consumption. Revised on 30 September 2026: The 20 W figure is printed as consumption at night ("Self-consumption at Night"), not as standby consumption; it moves to night consumption and standby consumption is unknown. Where: GoodWe A-BP Series datasheet, Technical Data, General data table, merged cell | [1] |
| Battery efficiency | 96.6 % | Printed as "Max. Battery to AC Efficiency 96.6%" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Efficiency table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe A-BP Series datasheet, Technical Data, Efficiency table, merged cell | [1] |
| Battery voltage range | 80 to 495 V | Printed as "Battery Voltage Range (V)*1 80 ~ 495" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Battery input table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe A-BP Series datasheet, Technical Data, Battery input table, merged cell | [1] |
| Operating temperature | -35 to 60 °C / -31 to 140 °F converted | Printed as "Operating Temperature Range -31°F ~ +140°F (-35°C ~ +60°C)" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026. Where: GoodWe A-BP Series datasheet, Technical Data, General data table, merged cell | [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- AC output (VA)
- 7,000 VA
- Battery voltage
- 80 to 495 V
- Solar input
- Not statedMPPT trackers Not stated
- AC output
- 240 V (L1-L2)
- Warranty
- 10 years
- Size
- 57.37 L* (Calculated from published dimensions)W: 415 × H: 790 × D: 175 mm / W: 16.3 × H: 31.1 × D: 6.89 inWeight 32 kg / 71 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "10 years *limited warranty for on-grid inverters including A-MS, MS G3 US, SMT-US, LV-SMT-US series, hybrid inverters including: A-ES, A-BP , ES US, SBP US series" in the GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930, captured on September 25, 2026. The policy names the A-BP series, not individual models; exclusions, claim steps and the start-date rule apply.
96.6 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10
Printed as "Max. Battery to AC Efficiency 96.6%" in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), Efficiency table, one value printed for every model in the table, captured on September 25, 2026.
Research pending, 0 points: Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
How it worksCertificates
California Rule 21manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Printed as "California Rule 21" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
CSA 22.2 No. 107-01manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Printed as "CSA 22.2 No. 107-01" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
FCC part15 CLASS Bmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Printed as "FCC part15 CLASS B" in the "Electromagnetic Compatibility" row of the Certification table ("Electromagnetic Compatibility FCC part15 CLASS B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
HECO Rule 14manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Printed as "HECO Rule 14" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
IEEE 1547manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Printed as "IEEE 1547" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
IEEE 1547.1manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Printed as "IEEE 1547.1" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL1699Bmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Printed as "UL1699B" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Printed as "UL 1741" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL1741 SAmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Printed as "UL1741 SA" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1998manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Printed as "UL 1998" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL991manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Printed as "UL991" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741 SAauthority listing reportedlisted as of snapshot[3]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as GoodWe Technologies Co., Ltd. "GW7000A-BP {240V}": UL 1741 SA, certifying entity CSA Group, certificate date 2021-09-17, CEC listing date 2021-01-21. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Sep 17, 2021Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [3]
UL 1741 SBauthority listing reportedlisted as of snapshot[3]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as GoodWe Technologies Co., Ltd. "GW7000A-BP {240V}": UL 1741 SB, certifying entity CSA Group, certificate date 2021-11-30, CEC listing date 2021-01-21. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Nov 30, 2021Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [3]
CECauthority listing reportedlisted as of snapshot[3]
- Scope
- equipment listing
- Covered models
- GW7000A-BP
- Limitations
- Model GW7000A-BP listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under GoodWe Technologies Co., Ltd., as "GW7000A-BP {240V}", CEC listing date 2021-01-21. This is an equipment listing, not UL certification or complete-system approval.
- Record detail
- Issued: Not statedValid from: Jan 21, 2021Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [3]
Warranty
| Field | Value | Conditions | Source |
|---|---|---|---|
| Territory | USA and Canada | Printed as "GOODWE Limited Warranty for Inverter System (for USA/CANADA market)" in the policy title, captured on September 25, 2026. Where: Title | [4] |
| Start basis | Earlier of first site commissioning, or 3 months after shipment from the GoodWe USA warehouse (6 months after shipment from the GoodWe China warehouse) | Printed as "starting from the earlier one of following two dates: 1. The date on which the product was first site commissioned. 2. 3 months after the date of product shipment from GOODWE USA warehouse (or 6 months after the date of product shipment from GOODWE China warehouse)." in the same policy, captured on September 25, 2026. Where: Overview, start-date clause | [4] |
| Warranty term | 10 years | Printed as "10 years *limited warranty for on-grid inverters including A-MS, MS G3 US, SMT-US, LV-SMT-US series, hybrid inverters including: A-ES, A-BP , ES US, SBP US series" in the GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930, captured on September 25, 2026. The policy names the A-BP series, not individual models; exclusions, claim steps and the start-date rule apply. Where: Overview, item 1 | [4] |
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- GoodWe A-BP Series User Manual (EN, V1.4-2023-01-30)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-27.
Location: 3.4.1 Inverter Specification (Technical Data tables); Battery wiring connection process
Retrieved Sep 26, 2026
GoodWe's own installation and operation manual for the A-BP series AC-coupled retrofit inverter (GW5000A-BP through GW9600A-BP), captured from us.goodwe.com on September 27, 2026. Covers US split-phase models only.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupV1.4 · 6.09 MBArchived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Skippower/downloadFileF?id=563&mid=60. Copyright and takedown
File details
Original sourcePrinted revision date: 2023-01-30
Embedded dates are file metadata, not independent proof of publication.
SHA-256: b7841c3671db300224cd65a5b8a30e3924112c0e81a9c8e4bba8b79ef2fb0210
Datasheets
- GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)Open
Certificate & compliance claims (11)
UL1741 SAManufacturer claim · equipment listingClaimedListed when checked
Printed as "UL1741 SA" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)California Rule 21Manufacturer claim · equipment listingClaimedListed when checked
Printed as "California Rule 21" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)HECO Rule 14Manufacturer claim · equipment listingClaimedListed when checked
Printed as "HECO Rule 14" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)IEEE 1547Manufacturer claim · equipment listingClaimedListed when checked
Printed as "IEEE 1547" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)IEEE 1547.1Manufacturer claim · equipment listingClaimedListed when checked
Printed as "IEEE 1547.1" in the "Grid Interconnection" row of the Certification table ("Grid Interconnection UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)UL 1741Manufacturer claim · equipment listingClaimedListed when checked
Printed as "UL 1741" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)CSA 22.2 No. 107-01Manufacturer claim · equipment listingClaimedListed when checked
Printed as "CSA 22.2 No. 107-01" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)UL 1998Manufacturer claim · equipment listingClaimedListed when checked
Printed as "UL 1998" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)UL991Manufacturer claim · equipment listingClaimedListed when checked
Printed as "UL991" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)UL1699BManufacturer claim · equipment listingClaimedListed when checked
Printed as "UL1699B" in the "Safety Regulations" row of the Certification table ("Safety Regulations UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)FCC part15 CLASS BManufacturer claim · equipment listingClaimedListed when checked
Printed as "FCC part15 CLASS B" in the "Electromagnetic Compatibility" row of the Certification table ("Electromagnetic Compatibility FCC part15 CLASS B") in the GoodWe A-BP Series datasheet (footer dated 2025-02-05, V2.1), captured on September 25, 2026. The datasheet lists the standard for the whole series and prints no file number, issuer or certificate; it is a manufacturer claim, and no issuer directory was read.
Manufacturer document
Official datasheet: GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Technical Data table, one column per model
Retrieved Sep 24, 2026
GoodWe family datasheet (A-BP Series), fetched from us.goodwe.com (the file the series page us.goodwe.com/a-bp-series-ac-coupled-retrofit-inverter-for-north-america links as "Datasheet") and archived on September 25, 2026. Its Technical Data table sets the models side by side, one column per model, so each figure is read from the named model column and the whole row is quoted; a value printed once spans every column. It names models, not ordering SKUs. It is a manufacturer claim; no figure was tested independently.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupGoodWe-Single page-20250205-US-EN-V2.1 · 0.52 MBArchived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Ftp/EN/Downloads/Datasheet/GW_A-BP_Datasheet-EN.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: cf2f1b853dc0767c5fe419304828a3fe5996642d6194e3f5d76569b1f7c9ef3a
Warranty
- GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Overview, item 1, and the start-date clause
Retrieved Sep 24, 2026
GoodWe limited warranty for inverters sold in the USA and Canada, fetched from us.goodwe.com (linked from us.goodwe.com/warranty as "USA & Canada Warranty") and archived on September 25, 2026. It names series, not models: 10 years for on-grid inverters of the A-MS, MS G3 US, SMT-US and LV-SMT-US series and hybrid inverters of the A-ES, A-BP, ES US and SBP US series. Coverage terms, exclusions and claim steps apply; it is the manufacturer's published policy, not a purchaser-specific contract.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRev 2.0 20250930 · 0.47 MBArchived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Ftp/Downloads/Warranty/GOODWE%20Limited%20Warranty%20for%20Inverter%20System-US&CA.pdf. Copyright and takedown
File details
Original sourcePrinted revision date: 2025-09-30
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 99433bc9d7f3562a66ab25d1afbfef3e8fe0119b722be112a7bd41b7281b31b7
Other documents
- GoodWe GW5000A-BP product identityOpen
Source details
Revision date not established.
Location: Original source record
Retrieved Sep 15, 2026
Archive and older revisions
Archive and older revisions1
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
- GoodWe USA: A-BP Series AC-coupled retrofit inverter for North AmericaOpen
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Product image (page share image)
Retrieved Sep 24, 2026
GoodWe USA series page for the A-BP inverters, captured on September 25, 2026 for its product image; one photograph is published for the whole series (GW5000A-BP to GW9600A-BP), so it does not show a specific power rating.
Archived documents
GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1)
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Ftp/EN/Downloads/Datasheet/GW_A-BP_Datasheet-EN.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: cf2f1b853dc0767c5fe419304828a3fe5996642d6194e3f5d76569b1f7c9ef3a
GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Ftp/Downloads/Warranty/GOODWE%20Limited%20Warranty%20for%20Inverter%20System-US&CA.pdf. Copyright and takedown
File details
Original sourcePrinted revision date: 2025-09-30
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 99433bc9d7f3562a66ab25d1afbfef3e8fe0119b722be112a7bd41b7281b31b7
GoodWe A-BP Series User Manual (EN, V1.4-2023-01-30)
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what GoodWe published. Original address: https://us.goodwe.com/Skippower/downloadFileF?id=563&mid=60. Copyright and takedown
File details
Original sourcePrinted revision date: 2023-01-30
Embedded dates are file metadata, not independent proof of publication.
SHA-256: b7841c3671db300224cd65a5b8a30e3924112c0e81a9c8e4bba8b79ef2fb0210
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- GW7000A-BP
Observed Oct 11, 2026
UL 1741 SA: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as GoodWe Technologies Co., Ltd. "GW7000A-BP {240V}": UL 1741 SA, certifying entity CSA Group, certificate date 2021-09-17, CEC listing date 2021-01-21. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
UL 1741 SB: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as GoodWe Technologies Co., Ltd. "GW7000A-BP {240V}": UL 1741 SB, certifying entity CSA Group, certificate date 2021-11-30, CEC listing date 2021-01-21. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model GW7000A-BP listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under GoodWe Technologies Co., Ltd., as "GW7000A-BP {240V}", CEC listing date 2021-01-21. This is an equipment listing, not UL certification or complete-system approval.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 90 basis: Unknown missing: Idle consumption needed criteria: key: certificates label: Certificates value: 31.5 unit: Unknown shown: UL 1741 SB · UL1741 SA +11 shown detail: Claimed state: claimed points: 14.2 ceiling: 45 weight: 45 share: 31.5 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown Sources: [3] key: warranty label: Warranty term value: 10 unit: Unknown shown: 10 years shown detail: Unknown state: documented points: 12 ceiling: 30 weight: 30 share: 40 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [4] key: efficiency label: Battery conversion efficiency value: 96.6 unit: Unknown shown: 96.6 % shown detail: Unknown state: documented points: 14.8 ceiling: 15 weight: 15 share: 98.4 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- GoodWe A-BP Series datasheet (GoodWe-Single page-20250205-US-EN-V2.1) (GoodWe · manufacturer · GoodWe-Single page-20250205-US-EN-V2.1 · observed Sep 24, 2026)
- GoodWe A-BP Series User Manual (EN, V1.4-2023-01-30) (GoodWe · manufacturer · V1.4 · observed Sep 26, 2026)
- CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
- GOODWE Limited Warranty for Inverter System (for USA/CANADA market), Rev 2.0 20250930 (GoodWe · manufacturer · Rev 2.0 20250930 · observed Sep 24, 2026)
Sign in to report an error on this page
Similar products
All with a priceGoodWe GW5000A-BP
GoodWe GW6000A-BP
GoodWe GW7600A-BP
GoodWe GW8600A-BP
* Missing details