Key specs

Continuous output4 kW
Converted: 4000 W / 1000 W/kW
Weight15.7 kg / 34.6 lb converted

All specifications

Identity

BrandEcoFlow · Website
ModelEF-PK-H05-1
MarketUnknown
Manufacturer SKUPOWERHUB-5KVA
SKU detail
locator: Title; product data: variant "Power Hub 5kVA", SKU
conditions: EcoFlow's US store page titled "Power Hub 5kVA with Cable Pack" prints one variant, "Power Hub 5kVA", SKU POWERHUB-5KVA; EcoFlow sells the hub with its cable pack under this one code.
Sources: [1]
FieldValueConditionsSource
PV inputsAlternator Input 1 / PV Input 1: 13-60V⎓100A, 4000W Max; Alternator Input 2/3 / PV Input 2/3: 13-60V⎓30A, 1600W Max per port
The input rows as printed; each port takes an alternator or a PV input.
Where: Technical Specifications, Input
[2]
Weight15.7 kg / 34.6 lb convertedPrinted as "Approx. 15.7 kg (34.6 lb)".
Where: Technical Specifications, General
[2]
DC outputs12V/24V: 13.6V⎓100A, 1360W Max / 26.4V⎓60A, 1584W Max; 48V: 40-57.6V⎓55A, 3168W Max; USB-A 5V⎓2.4A Max
The DC output rows as printed; the table also prints "Total Output Power 8752W Max (AC 4000W + DC (12V/24V) 1584W + DC (48V) 3168W)".
Where: Technical Specifications, Output
[2]
Peak output7500VA for 380 ms; 10000VA Max
Printed as "(surge 7500VA 380ms, 10000VA Max)" for both voltage versions.
Where: Technical Specifications, Output
[2]
Max charge270 A
Printed as "40-57.6V⎓100A Max per port, total 270A Max" (Charge); discharge is printed as "total 181A Max".
Where: Technical Specifications, Battery Port (x3)
[2]
DimensionsW 480 × H 300 × D 151 mm / W 18.9 × H 11.8 × D 5.94 in converted
Printed as "Dimensions (W×D×H) 480x151x300 mm (18.9x5.9x11.8 in.)".
Where: Technical Specifications, General
[2]
CommunicationsWi-Fi (2.4G, 5G), BluetoothAs printed in the Communication Method row.
Where: Technical Specifications, Communication
[2]
Enclosure ratingIP20Printed as "IP Rating IP20".
Where: Technical Specifications, Other
[2]
Apparent power5,000 VA
Printed as "5000VA Max" for the AC output of both voltage versions.
Where: Technical Specifications, Output
[2]
Certification claimsUL1012, UL1778, UL458, CSA C22.2 NO. 107.1, CSA C22.2 NO. 107.3, IEC/EN 62368-1, IEC/EN 62040-1, IEC/EN 60335-1, IEC/EN 60335-2-29, AS/NZS 60335.1, AS/NZS 60335.2.29, AS/NZS 62040.1
The Safety row, as printed; manufacturer claims, no issuer directory was checked.
Where: Technical Specifications, Compliance, Safety
[2]
Continuous output4 kW
Converted: 4000 W / 1000 W/kW
Printed as "4000W Max, 5000VA Max" for the AC output (discharge only) of both the Low Voltage Power Hub ("120V~4000W Max, 5000VA Max, 60Hz, continuous output 33.3A") and the High Voltage Power Hub ("continuous output 18.18A").
Where: Technical Specifications, Output
Sources
Converted: 4000 W / 1000 W/kW
[2]
Battery voltage range40 to 57.6 V
Printed as "40-57.6V⎓100A Max per port" for charge and discharge on each of the three battery ports.
Where: Technical Specifications, Battery Port (x3)
[2]
Operating temperature-25 to 60 °C / -13 to 140 °F converted
Printed as "–25℃ to 60℃ (–13°F to 140°F), derating>40°C (104°F)" for both charging and discharging temperature.
Where: Technical Specifications, Environment
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
4 kW
Battery voltage
40 to 57.6 V
Solar input
Not statedMPPT trackers Not stated
AC output
Not stated
Warranty
Not stated
Size
21.74 L* (Calculated from published dimensions)W: 480 × H: 300 × D: 151 mm / W: 18.9 × H: 11.8 × D: 5.94 inWeight 15.7 kg / 34.6 lb

Evidence score

Research pending0% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • EcoFlow Power Hub 5kVA User Manual (online) (November 3, 2026 capture)Official · EcoFlow · Official user manual · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured Nov 3, 2026 (private archived copy).

    Location: Overview; Technical Specifications

    Retrieved Nov 3, 2026

    EcoFlow's Power Hub 5kVA user manual, with its Technical Specifications table (Model EF-PK-H05-1), which prints a Low Voltage and a High Voltage Power Hub in the AC rows. EcoFlow's online user manual on manuals.ecoflow.com, which carries the whole manual in the page data; read from that data. Its address is the one EcoFlow's public support download list gives for this product. Fetched directly on November 3, 2026 (robots.txt checked first; request logged 20:20:51.645 UTC). Kept as a private copy only. Manufacturer claims, not independent tests.

    Open
  • Other documents

  • EcoFlow US store page: Power Hub 5kVA with Cable Pack (November 3, 2026 capture)Official · EcoFlow · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured Nov 3, 2026 (private archived copy).

    Location: Product data: variant name and SKU

    Retrieved Nov 3, 2026

    EcoFlow's own US store page titled "Power Hub 5kVA with Cable Pack", whose product data prints variant "Power Hub 5kVA" with SKU POWERHUB-5KVA. Fetched directly from us.ecoflow.com with the paced research fetcher on November 3, 2026 (robots.txt checked first; request ended 19:55:29.834 UTC). Read for the product title and the variant name and SKU only; no price or stock state is recorded. Kept as a private copy only. Manufacturer claims, not independent tests.

    Open

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
EF-PK-H05-1

Manufacturer SKU POWERHUB-5KVA

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 0
basis: Unknown
missing:
Certificate evidence needed
Warranty term needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. EcoFlow US store page: Power Hub 5kVA with Cable Pack (November 3, 2026 capture) (EcoFlow · manufacturer · observed Nov 3, 2026)
  2. EcoFlow Power Hub 5kVA User Manual (online) (November 3, 2026 capture) (EcoFlow · manufacturer · observed Nov 3, 2026)