conditions: EcoFlow's United Kingdom OCEAN 2 page, the user manual and the datasheet, captured on September 29, 2026, print the model number EF BD-8-S2 but no ordering SKU; none is recorded.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Chemistry
LiFePO₄
Printed as "Battery Cell Type LiFePO₄" in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2.
Where: English Technical Specifications table (EF BD-8-S2), Battery Cell Type
Printed as "Ground the junction box for cascading batteries." in the EcoFlow OCEAN 2 LFP Battery 8kWh User Manual V1.1, for installer and home owner, EU (issue date 2026-08-31) (page 6, Important safety instructions, electrical safety, grounding). English section. The manual is the EU edition and does not name a UK version; this UK record is filled from it as the same product sold in the UK.
Where: PDF page 6, Important safety instructions, electrical safety, grounding
Printed as "2 Click-on terminal Stacking terminal 3 Nameplate" in the EcoFlow OCEAN 2 LFP Battery 8kWh User Manual V1.1, for installer and home owner, EU (issue date 2026-08-31) (page 11, EcoFlow OCEAN 2 LFP Battery 8kWh appearance table, item 2). English section. The manual is the EU edition and does not name a UK version; this UK record is filled from it as the same product sold in the UK.
Printed as "Weight (kg) Approx. 67.5" in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2.
Where: English Technical Specifications table (EF BD-8-S2), Weight
Printed as "the built-in thermal control system starts to heat the battery to achieve better performance" in the EcoFlow OCEAN 2 LFP Battery 8kWh User Manual V1.1, for installer and home owner, EU (issue date 2026-08-31) (page 7, Important safety instructions, installation environment requirements). English section. The manual states heating uses rechargeable power and briefly reduces efficiency in cold weather. The manual is the EU edition and does not name a UK version; this UK record is filled from it as the same product sold in the UK.
Where: PDF page 7, Important safety instructions, installation environment requirements
Printed as "≥300 mm Minimum clearance between parallel battery stacks" in the EcoFlow OCEAN 2 LFP Battery 8kWh User Manual V1.1, for installer and home owner, EU (issue date 2026-08-31) (page 15, Installation Clearance Requirements). English section. The manual is the EU edition and does not name a UK version; this UK record is filled from it as the same product sold in the UK.
Where: PDF page 15, Installation Clearance Requirements
W 679.6 × H 378 × L 195.6 mm / W 26.76 × H 14.9 × L 7.7 in convertedCheck note
EcoFlow's own documents disagree. The OCEAN 2 LFP Battery 8kWh user manual V1.1 prints 679.6 x 195.6 x 378 mm (W x D x H) for EF BD-8-S2; EcoFlow's OCEAN 2 Three-Phase datasheet (EN) and its product page print 680 x 196 x 378 mm. The manual's figure is shown because the manual is the primary source; the datasheet's figure is kept beside it.
Printed as "Dimension (WxDxH) (mm) 679.6×195.6×378" in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2; width x depth x height.
Where: English Technical Specifications table (EF BD-8-S2), Dimension (WxDxH)
Sources
W 680 × H 378 × L 196 mm
Printed as "Dimension(W×D×H)(mm)680 × 196 × 279680 × 196 × 378" (the second set for EF BD-8-S2) in EcoFlow's OCEAN 2 Three-Phase datasheet (EN); the product page prints "Dimension (W×D×H) 680 × 196 × 378 mm".
Floor stand with up to 6 batteries per tower, or wall mounted with up to 3 batteries per tower (maximum 4 towers in parallel)
Printed as "Floor Stand: Up to 6 batteries per tower, maximum 4 towers in parallel"; "Wall Mounted: Up to 3 batteries per tower, maximum 4 towers in parallel" in the EcoFlow OCEAN 2 LFP Battery 8kWh User Manual V1.1, for installer and home owner, EU (issue date 2026-08-31) (page 12, Technical Specification (EF BD-8-S2), Installation row). English section. The wall-mounted battery base is sold separately. The manual is the EU edition and does not name a UK version; this UK record is filled from it as the same product sold in the UK.
Where: PDF page 12, Technical Specification (EF BD-8-S2), Installation row
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "Installation Floor Stand: A stack of up to 6 batteries Wall Mounted: A stack of up to 3 batteries". Classified as Stackable from the maker's own words for this model; the maker also prints wall or floor mounting, quoted here (PM decision, October 13, 2026: a unit printing both wall or floor mounting and a stackable design is Stackable).
Printed as "Communication Method CAN" in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2.
Where: English Technical Specifications table (EF BD-8-S2), Communication Method
Battery power cable 6 to 10 mm², rated 1000 V DC or higher; ground cable 10 mm²
Printed as "Battery power cable 6-10 mm² with a rated voltage greater than or equal to 1000V"; "1 Ground cable 10 mm²" in the EcoFlow OCEAN 2 LFP Battery 8kWh User Manual V1.1, for installer and home owner, EU (issue date 2026-08-31) (page 19, Electrical Connection, legend). English section. Cables between the battery junction box and the inverter. The manual is the EU edition and does not name a UK version; this UK record is filled from it as the same product sold in the UK.
The exact model's technical table prints Nominal Voltage (V) "400 / 800" and Operating Voltage Range (V) "360-520 / 720-960". Both literal choices remain; no voltage option is selected and no combined range is invented.
Where: 8 kWh manual V1.1, PDF pages 9 and 12 / printed pages 5 and 8
Printed as "Battery Usable Capacity1 (kWh) 7.76" in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2. Footnote 1: tested at 25°C; "the battery undergoes 0.2C charge/ discharge cycling at 100% depth of discharge (DoD) during beginning of life (BOL)".
Where: English Technical Specifications table (EF BD-8-S2), Battery Usable Capacity
Battery junction box: built-in DC 1500 Vd.c./32A replaceable fuse
Printed as "The Battery junction box has a built-in DC 1500 Vd.c./32A replaceable fuse." in EcoFlow's ECOFLOW OCEAN 2 LFP BAT TERY 8kWh USER MANUAL V1.1 Issue Date: 2026-08-31 For the latest documents, please scan the QR code. EN DE FR IT ES (PDF page 24). The manual applies to this model: User Manual V1.1 "EcoFlow OCEAN 2 LFP Battery 8kWh" for installer and home owner, EU (EN DE FR IT ES NL SV); applied to the EU and UK records.
Printed as "Battery Nominal Capacity (kWh) 8.03" in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2. The United Kingdom page prints the same figure.
Where: English Technical Specifications table (EF BD-8-S2), Battery Nominal Capacity
Printed as "Communication Method CAN" in EcoFlow's ECOFLOW OCEAN 2 LFP BAT TERY 8kWh USER MANUAL V1.1 Issue Date: 2026-08-31 For the latest documents, please scan the QR code. EN DE FR IT ES (PDF page 12). The manual applies to this model: User Manual V1.1 "EcoFlow OCEAN 2 LFP Battery 8kWh" for installer and home owner, EU (EN DE FR IT ES NL SV); applied to the EU and UK records.
Printed as "Nominal discharging Power (W) 4100" in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2; recorded in kW. Printed as a nominal figure.
Where: English Technical Specifications table (EF BD-8-S2), Nominal discharging Power
Move and install the battery in an upright position
Printed as "Move and install the battery in an upright position." in the EcoFlow OCEAN 2 LFP Battery 8kWh User Manual V1.1, for installer and home owner, EU (issue date 2026-08-31) (page 7, Important safety instructions, battery safety). English section. The manual is the EU edition and does not name a UK version; this UK record is filled from it as the same product sold in the UK.
Where: PDF page 7, Important safety instructions, battery safety
Printed as "1. INTEGRATED STACKABLE DESIGNS: BATTERY JUNCTION BOX NOT REQUIRED"; "2. MODULAR SEPARATED DESIGNS: BATTERY JUNCTION BOX REQUIRED"; "EcoFlow PowerOcean Plus Three-Phase Hybrid Inverter" in the EcoFlow OCEAN 2 LFP Battery 8kWh User Manual V1.1, for installer and home owner, EU (issue date 2026-08-31) (page 9, Product Introduction, Networking Application). English section. The manual is the EU edition and does not name a UK version; this UK record is filled from it as the same product sold in the UK.
Where: PDF page 9, Product Introduction, Networking Application
Printed as "Storage Temperature (°C) -25 to 60" in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2.
Where: English Technical Specifications table (EF BD-8-S2), Storage Temperature
Printed as "Maximum discharging Power2 (W) 6400" in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2; recorded in kW. Footnote 2: "At 25°C ambient and device temperature under laboratory conditions, the discharge duration at the specified power is limited to a maximum of 30 minutes."
Where: English Technical Specifications table (EF BD-8-S2), Maximum discharging Power
Printed as "Operating Temperature3 (°C) -20 to 55" in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2. Footnote 3: "Power may be derated when the temperature exceeds 40°C."
Where: English Technical Specifications table (EF BD-8-S2), Operating Temperature
IEC/EN 62619, IEC/EN 62040-1, IEC/EN 62477-1, ISO 13849-1, VDE-AR-E 2510-50, SA TS 5398; UN38.3; EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4
Printed in the Compliance rows in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2 as safety standard, delivery standard and EMC standards. Recorded as manufacturer claims; no certificate or issuer record was read.
Where: English Technical Specifications table (EF BD-8-S2), Compliance
Printed as "Nominal Charging Power (W) 4100" in the English Technical Specifications table of EcoFlow's OCEAN 2 LFP Battery 8kWh user manual (V1.1), model EF BD-8-S2; recorded in kW. Printed as a nominal figure.
Where: English Technical Specifications table (EF BD-8-S2), Nominal Charging Power
50.25 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)! Value needs confirmation: EcoFlow's own documents disagreeW: 679.6 × H: 378 × L: 195.6 mm / W: 26.76 × H: 14.9 × L: 7.7 in67.5 kg / 149 lb0.16 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
13/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
High-voltage stacked batteries · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Printed as "Warranty 10 + 5 Years" with the footnote "*10-Year compulsory warranty and a 5-year optional extended warranty for the OCEAN2 8kWh LFP Battery." on EcoFlow's United Kingdom OCEAN 2 page, captured on September 29, 2026. The 10-year base term is recorded; the optional 5-year extension is kept in this note. Coverage terms were not read.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
10 years
Printed as "Warranty 10 + 5 Years" with the footnote "*10-Year compulsory warranty and a 5-year optional extended warranty for the OCEAN2 8kWh LFP Battery." on EcoFlow's United Kingdom OCEAN 2 page, captured on September 29, 2026. The 10-year base term is recorded; the optional 5-year extension is kept in this note. Coverage terms were not read.
EcoFlow's own manual, captured October 15, 2026 with the paced research fetcher (robots.txt read first). Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
EcoFlow's own English datasheet for the OCEAN 2 Three-Phase system, listed on EcoFlow's UK and Europe documentation pages and captured on September 29, 2026. Its "EcoFlow OCEAN 2 LFP Battery" table prints columns for EF BD-5-S2 and EF BD-8-S2. No revision date is printed. EcoFlow claims, not independent tests.
Archived copies
Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Specs section; footnotes
Retrieved Sep 28, 2026
EcoFlow's own United Kingdom home battery page for the OCEAN 2 Three-Phase, captured on September 29, 2026. Its Specs section prints tables for the OCEAN 2 LFP Battery 8kWh and 5 kWh packs. EcoFlow claims, not independent tests.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Document links
Retrieved Sep 28, 2026
EcoFlow's own United Kingdom documentation page on energy.ecoflow.com, captured on September 29, 2026. Cited to show that the documents listed below are the ones EcoFlow publishes for this region; it prints no specification.
EcoFlow OCEAN 2 LFP Battery 8kWh User Manual V1.1, for installer and home owner, EU (issue date 2026-08-31)
Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.