Runergy HY-WH120P8-445

By RunergySKU not documented

Key specs

Units
Rated output (STC)
445 W
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here. The power tolerance is printed as 0 ~ +5 W.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Maximum Power at STC (Pmax/W) row, 445 W column

Documented

Module efficiency
20.6 %
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Module Efficiency row, 445 W column

Documented

Voltage at max power (Vmp)
34.57 V
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Optimum Operating Voltage (Vmp/V) row, 445 W column

Documented

Current at max power (Imp)
12.87 A
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Optimum Operating Current (Imp/A) row, 445 W column

Documented

Open-circuit voltage (Voc)
41.04 V
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Open Circuit Voltage (Voc/V) row, 445 W column

Documented

Short-circuit current (Isc)
13.79 A
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Short Circuit Current (Isc/A) row, 445 W column

Documented

Power temperature coefficient
-0.35 %/°C
Official datasheet
Sources

Printed as "-0.35%/°C" in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0).

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Temperature Characteristics, Temperature Coefficient of Pmax

Documented

Maximum system voltage
1,500 V
Official datasheet
Sources

Printed as "DC 1500V(IEC/UL)" in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0).

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Operating Parameters, Max. System Voltage

Documented

All specs26
Rated output (STC)
445 W
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here. The power tolerance is printed as 0 ~ +5 W.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Maximum Power at STC (Pmax/W) row, 445 W column

Documented

Module efficiency
20.6 %
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Module Efficiency row, 445 W column

Documented

Voltage at max power (Vmp)
34.57 V
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Optimum Operating Voltage (Vmp/V) row, 445 W column

Documented

Current at max power (Imp)
12.87 A
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Optimum Operating Current (Imp/A) row, 445 W column

Documented

Open-circuit voltage (Voc)
41.04 V
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Open Circuit Voltage (Voc/V) row, 445 W column

Documented

Short-circuit current (Isc)
13.79 A
Official datasheet
Sources

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Electrical Characteristics - STC, Short Circuit Current (Isc/A) row, 445 W column

Documented

Power temperature coefficient
-0.35 %/°C
Official datasheet
Sources

Printed as "-0.35%/°C" in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0).

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Temperature Characteristics, Temperature Coefficient of Pmax

Documented

Maximum system voltage
1,500 V
Official datasheet
Sources

Printed as "DC 1500V(IEC/UL)" in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0).

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 2, Operating Parameters, Max. System Voltage

Documented

Published claims and calculations, not independent test results.

Documents

1 on file
  • PDF
    HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0OfficialRunergyOfficial datasheet
    Certificate & compliance claims (6)
    IEC 61215Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
    IEC 61730Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
    UL 61730Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
    IEC 61701Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
    IEC 62716Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
    IEC 60068Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
    Source details
    Revision
    HY-WH120P8-Global-Ver3.0
    Revision date
    Not stated

    Archived copy captured on 2026-10-30.

    Location: Pages 1 and 2

    Retrieved

    Runergy's two-page global datasheet for the HY-WH120P8 P-type (PERC) single glass module, 445 to 465 W (HY-WH120P8-Global-Ver3.0, copyright 2023), on Runergy's own file host (runergy.com) and linked from Runergy's P-type module product page, captured October 30, 2026 (UTC) for batch 7. Page 1 prints "HY-WH120P8", "445-465W" and "P-Type" over "Single Glass"; page 2 heads the tables "HY-WH120P8-445/465". Runergy's P-type product page links this file under "Single Glass WH120P8 440-460Wp"; the datasheet itself prints 445 to 465 W, recorded here. Electrical figures are read from each power class column of Electrical Characteristics - STC on the rendered page 2. Manufacturer claims, not independently verified.

    Archived copies

    Archived copy of a document published by Runergy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.17 MB

    Archived copy, unaltered, kept as a record of what Runergy published. Original address: https://www.runergy.com/wp-content/uploads/download/WH120P8.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: c9abbffca230ed02a03a5b8744bf5636f20f650e7a05807076c6f8e1b693fe01

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0

Archived copy of a document published by Runergy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.17 MB

Archived copy, unaltered, kept as a record of what Runergy published. Original address: https://www.runergy.com/wp-content/uploads/download/WH120P8.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: c9abbffca230ed02a03a5b8744bf5636f20f650e7a05807076c6f8e1b693fe01

Submit a document

Warranty

Warranted final output
84.8 %
Official datasheet
Sources

The warranty chart prints 84.8% at year 25 (and 98% at year 1) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0).

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 1, Product performance warranty chart

Documented

Product warranty
15 years
Official datasheet
Sources

Printed as "15 Years warranty for materials and workmanship" on page 1 of the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); page 2 prints "Product Workmanship Warranty 15 Years".

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

Annual degradation after year one
0.55 %
Official datasheet
Sources

Printed as "1st year <2%, annual degradation <0.55%" in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); an upper bound.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

First-year degradation
2 %
Official datasheet
Sources

Printed as "1st year <2%, annual degradation <0.55%" in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); an upper bound.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

Power warranty
25 years
Official datasheet
Sources

Printed as "25 Years warranty for extra linear power output" on page 1 of the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); page 2 prints "Linear Power Output Warranty 25 Years".

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

67/100100% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Every scored input has a recorded source for this product.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency20.6 %21.0 / 26.0

20.6 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. NMOT figures are not recorded here.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
Product warranty15 years10.5 / 21.0

15 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module

Printed as "15 Years warranty for materials and workmanship" on page 1 of the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); page 2 prints "Product Workmanship Warranty 15 Years".

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
Power warranty25 years13.3 / 16.0

25 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A460-MCE54Db 460W Dual-Glass Module

Printed as "25 Years warranty for extra linear power output" on page 1 of the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); page 2 prints "Linear Power Output Warranty 25 Years".

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
First-year degradation2 %8.0 / 16.0

2 against 1 %, the lowest documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A460-MCE54Db 460W Dual-Glass Module

Printed as "1st year <2%, annual degradation <0.55%" in the Runergy HY-WH120P8 445-465W datasheet (file WH120P8.pdf, printed HY-WH120P8-Global-Ver3.0); an upper bound.

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

6 on file12 claims on file · issuer check pending
IEC 61215Product / system scope unresolvedClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-WH120P8-445/465

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
IEC 61730Product / system scope unresolvedClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-WH120P8-445/465

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
UL 61730Product / system scope unresolvedClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-WH120P8-445/465

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
IEC 61701Product / system scope unresolvedClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-WH120P8-445/465

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
IEC 62716Product / system scope unresolvedClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-WH120P8-445/465

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
IEC 60068Product / system scope unresolvedClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-WH120P8-445/465

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
Datasheet & manual claims6
IEC 61215Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
IEC 61730Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
UL 61730Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
IEC 61701Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
IEC 62716Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document
IEC 60068Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-WH120P8-Global-Ver3.0 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001/ ISO45001" on page 1 for the series, which includes HY-WH120P8-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-WH120P8 445-465W single glass datasheet, HY-WH120P8-Global-Ver3.0 Rev HY-WH120P8-Global-Ver3.0 · Checked · Earlier document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
HY-WH120P8-445

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.