Runergy HY-DH132N10-Plus-720

By RunergySKU not documented

No owner reviews yet · Write the first

Key specs

Units
Rated output (STC)
720 W
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here. The power tolerance is printed as 0 ~ +5 W.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Maximum Power at STC (Pmax/W) row, 720 W column

Documented

Module efficiency
23.2 %
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Module Efficiency row, 720 W column

Documented

Voltage at max power (Vmp)
41.29 V
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Voltage (Vmp/V) row, 720 W column

Documented

Current at max power (Imp)
17.44 A
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Current (Imp/A) row, 720 W column

Documented

Open-circuit voltage (Voc)
49.39 V
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Open Circuit Voltage (Voc/V) row, 720 W column

Documented

Short-circuit current (Isc)
18.49 A
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Short Circuit Current (Isc/A) row, 720 W column

Documented

Power temperature coefficient
-0.29 %/°C
Official datasheet
Sources

Printed as "-0.29%/°C" in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4).

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Temperature characteristics, Temperature Coefficient of Pmax

Documented

Maximum system voltage
1,500 V
Official datasheet
Sources

Printed as "DC 1500V(IEC/UL)" in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4).

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Operating parameters, Max. System Voltage

Documented

All specs27
Rated output (STC)
720 W
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here. The power tolerance is printed as 0 ~ +5 W.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Maximum Power at STC (Pmax/W) row, 720 W column

Documented

Module efficiency
23.2 %
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Module Efficiency row, 720 W column

Documented

Voltage at max power (Vmp)
41.29 V
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Voltage (Vmp/V) row, 720 W column

Documented

Current at max power (Imp)
17.44 A
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Current (Imp/A) row, 720 W column

Documented

Open-circuit voltage (Voc)
49.39 V
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Open Circuit Voltage (Voc/V) row, 720 W column

Documented

Short-circuit current (Isc)
18.49 A
Official datasheet
Sources

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Short Circuit Current (Isc/A) row, 720 W column

Documented

Power temperature coefficient
-0.29 %/°C
Official datasheet
Sources

Printed as "-0.29%/°C" in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4).

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Temperature characteristics, Temperature Coefficient of Pmax

Documented

Maximum system voltage
1,500 V
Official datasheet
Sources

Printed as "DC 1500V(IEC/UL)" in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4).

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Operating parameters, Max. System Voltage

Documented

Published claims and calculations, not independent test results.

Documents

1 on file
  • PDF
    HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4OfficialRunergyOfficial datasheet
    Certificate & compliance claims (6)
    IEC 61215Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
    IEC 61730Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
    UL 61730Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
    IEC 61701Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
    IEC 62716Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
    IEC 60068Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
    Source details
    Revision
    HY-DH132N10-Plus-Global-Ver25Q4
    Revision date
    Not stated

    Archived copy captured on 2026-10-30.

    Location: Pages 1 and 2

    Retrieved

    Runergy's two-page global datasheet for the HY-DH132N10 Plus N-type bifacial dual glass module, 700 to 730 W (HY-DH132N10-Plus-Global-Ver25Q4, copyright 2025), on Runergy's own file host (runergy.com) and linked from Runergy's download page, captured October 30, 2026 (UTC). Page 1 prints "HY-DH132N10" with a "Plus" mark and page 2 heads the tables "HY-DH132N10 700-730"; the Plus name is printed in the version line. The text layer runs several power class columns together, so each column was read on the rendered page 2. Manufacturer claims, not independently verified.

    Archived copies

    Archived copy of a document published by Runergy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 1.12 MB

    Archived copy, unaltered, kept as a record of what Runergy published. Original address: https://www.runergy.com/wp-content/uploads/download/25Q4/Global%20N10%20H10%2025Q4/HY-DH132N10-Plus-Global-Ver25Q4(700-730W).pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2
    Embedded creation date
    Dec 27, 2025
    Embedded modification date
    Jan 13, 2026

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 8cf9f8167dd7971b9b629cc53cd45e3a715ea80c87a79af6daefc100aaa16572

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4

Archived copy of a document published by Runergy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 1.12 MB

Archived copy, unaltered, kept as a record of what Runergy published. Original address: https://www.runergy.com/wp-content/uploads/download/25Q4/Global%20N10%20H10%2025Q4/HY-DH132N10-Plus-Global-Ver25Q4(700-730W).pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Dec 27, 2025
Embedded modification date
Jan 13, 2026

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 8cf9f8167dd7971b9b629cc53cd45e3a715ea80c87a79af6daefc100aaa16572

Submit a document

Warranty

Warranted final output
87.4 %
Official datasheet
Sources

The warranty chart prints 87.4% at year 30 (and 89.4% at year 25) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4).

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 1, Product performance warranty chart

Documented

Product warranty
12 years
Official datasheet
Sources

Printed as "12-year product warranty" in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4).

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

Annual degradation after year one
0.4 %
Official datasheet
Sources

Printed as "1st year degradation <1%, annual degradation <0.4%" in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); an upper bound.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

First-year degradation
1 %
Official datasheet
Sources

Printed as "1st year degradation <1%, annual degradation <0.4%" in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); an upper bound.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

Power warranty
30 years
Official datasheet
Sources

Printed as "30-year linear power warranty" in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4).

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

80/100100% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Every scored input has a recorded source for this product.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency23.2 %23.7 / 26.0

23.2 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Read from the 720 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 Plus 700-730W datasheet (HY-DH132N10-Plus-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

6 on file12 claims on file · issuer check pending
IEC 61215Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
IEC 61730Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
UL 61730Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
IEC 61701Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
IEC 62716Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
IEC 60068Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
Datasheet & manual claims6
IEC 61215Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
IEC 61730Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
UL 61730Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
IEC 61701Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
IEC 62716Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document
IEC 60068Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Plus-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-Plus-720; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4 Rev HY-DH132N10-Plus-Global-Ver25Q4 · Checked · Earlier document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
HY-DH132N10-Plus-720

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.