Runergy HY-DH132N10-715

By RunergySKU not documented

No owner reviews yet · Write the first

Key specs

Units
Rated output (STC)
715 W
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here. The power tolerance is printed as 0 ~ +5 W.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Maximum Power at STC (Pmax/W) row, 715 W column

Documented

Module efficiency
23 %
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Module Efficiency row, 715 W column

Documented

Voltage at max power (Vmp)
41.1 V
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Voltage (Vmp/V) row, 715 W column

Documented

Current at max power (Imp)
17.4 A
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Current (Imp/A) row, 715 W column

Documented

Open-circuit voltage (Voc)
49.2 V
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Open Circuit Voltage (Voc/V) row, 715 W column

Documented

Short-circuit current (Isc)
18.44 A
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Short Circuit Current (Isc/A) row, 715 W column

Documented

Power temperature coefficient
-0.29 %/°C
Official datasheet
Sources

Printed as "-0.29%/°C" in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4).

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Temperature characteristics, Temperature Coefficient of Pmax

Documented

Maximum system voltage
1,500 V
Official datasheet
Sources

Printed as "DC 1500V(IEC/UL)" in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4).

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Operating parameters, Max. System Voltage

Documented

All specs27
Rated output (STC)
715 W
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here. The power tolerance is printed as 0 ~ +5 W.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Maximum Power at STC (Pmax/W) row, 715 W column

Documented

Module efficiency
23 %
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Module Efficiency row, 715 W column

Documented

Voltage at max power (Vmp)
41.1 V
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Voltage (Vmp/V) row, 715 W column

Documented

Current at max power (Imp)
17.4 A
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Current (Imp/A) row, 715 W column

Documented

Open-circuit voltage (Voc)
49.2 V
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Open Circuit Voltage (Voc/V) row, 715 W column

Documented

Short-circuit current (Isc)
18.44 A
Official datasheet
Sources

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Short Circuit Current (Isc/A) row, 715 W column

Documented

Power temperature coefficient
-0.29 %/°C
Official datasheet
Sources

Printed as "-0.29%/°C" in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4).

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Temperature characteristics, Temperature Coefficient of Pmax

Documented

Maximum system voltage
1,500 V
Official datasheet
Sources

Printed as "DC 1500V(IEC/UL)" in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4).

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 2, Operating parameters, Max. System Voltage

Documented

Published claims and calculations, not independent test results.

Documents

1 on file
  • PDF
    HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4OfficialRunergyOfficial datasheet
    Certificate & compliance claims (6)
    IEC 61215Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
    IEC 61730Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
    UL 61730Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
    IEC 61701Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
    IEC 62716Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
    IEC 60068Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
    Source details
    Revision
    HY-DH132N10-Global-Ver25Q4
    Revision date
    Not stated

    Archived copy captured on 2026-10-30.

    Location: Pages 1 and 2

    Retrieved

    Runergy's two-page global datasheet for the HY-DH132N10 N-type bifacial dual glass module, 700 to 730 W (HY-DH132N10-Global-Ver25Q4, copyright 2025), on Runergy's own file host (runergy.com) and linked from Runergy's download page, captured October 30, 2026 (UTC). Page 1 prints "HY-DH132N10" and page 2 heads the tables "HY-DH132N10 700-730". The text layer runs several power class columns together, so each column was read on the rendered page 2. Manufacturer claims, not independently verified.

    Archived copies

    Archived copy of a document published by Runergy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 1.12 MB

    Archived copy, unaltered, kept as a record of what Runergy published. Original address: https://www.runergy.com/wp-content/uploads/download/25Q4/Global%20N10%20H10%2025Q4/HY-DH132N10-Global-Ver25Q4(700-730W).pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2
    Embedded creation date
    Dec 27, 2025
    Embedded modification date
    Jan 13, 2026

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 6b1f212d4f33c7bfa3af83f5e47218ef165fd2a312126ed7920fc40053fc6fd3

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4

Archived copy of a document published by Runergy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 1.12 MB

Archived copy, unaltered, kept as a record of what Runergy published. Original address: https://www.runergy.com/wp-content/uploads/download/25Q4/Global%20N10%20H10%2025Q4/HY-DH132N10-Global-Ver25Q4(700-730W).pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Dec 27, 2025
Embedded modification date
Jan 13, 2026

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 6b1f212d4f33c7bfa3af83f5e47218ef165fd2a312126ed7920fc40053fc6fd3

Submit a document

Warranty

Warranted final output
87.4 %
Official datasheet
Sources

The warranty chart prints 87.4% at year 30 (and 89.4% at year 25) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4).

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 1, Product performance warranty chart

Documented

Product warranty
12 years
Official datasheet
Sources

Printed as "12-year product warranty" in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4).

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

Annual degradation after year one
0.4 %
Official datasheet
Sources

Printed as "1st year degradation <1%, annual degradation <0.4%" in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); an upper bound.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

First-year degradation
1 %
Official datasheet
Sources

Printed as "1st year degradation <1%, annual degradation <0.4%" in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); an upper bound.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

Power warranty
30 years
Official datasheet
Sources

Printed as "30-year linear power warranty" in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4).

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Location: Page 1, Product performance warranty

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

80/100100% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Every scored input has a recorded source for this product.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency23 %23.5 / 26.0

23 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Read from the 715 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); the text layer runs this column together with its neighbors, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
First-year degradation1 %16.0 / 16.0

This is the lowest documented for a solar panel, printed by the maker. 368 solar panels share this value.

Printed as "1st year degradation <1%, annual degradation <0.4%" in the Runergy HY-DH132N10 700-730W datasheet (HY-DH132N10-Global-Ver25Q4); an upper bound.

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

6 on file12 claims on file · issuer check pending
IEC 61215Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
IEC 61730Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
UL 61730Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
IEC 61701Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
IEC 62716Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
IEC 60068Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH132N10 700-730

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
Datasheet & manual claims6
IEC 61215Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
IEC 61730Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
UL 61730Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
IEC 61701Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
IEC 62716Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document
IEC 60068Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH132N10-Global-Ver25Q4 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH132N10-715; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH132N10 700-730W bifacial datasheet, HY-DH132N10-Global-Ver25Q4 Rev HY-DH132N10-Global-Ver25Q4 · Checked · Earlier document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
HY-DH132N10-715

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.